HomeMy WebLinkAbout#141 Remington Distribution Center Remington distribution Center HAMANN
Sign Program COMPANIES
REMINGTON DISTRIBUTION CENTER
MASTER SIGN CRITERIA
42006 Remington Avenue ,
Project Location:
Temecula CA 92590 42006 Remington Avenue,
Temecula, CA 92590
Project No.: 1 61 1 1 5-05
PROPERTY OWNER:
Cactus Road Salesman: AC
OWNER'S ADDRESS: Designer:
Oscar Lopez
1000 Pioneer Way, Date: June 21,2017
El Cajon, CA 92020
LEGAL DESCRIPTION: Revision:
APN#: 909-370-013 A
IN PAR Z�
• PM 190/095 _
PM 24085-3
CITY OF TEMECULA, CA A
+ APPRO ZONE: LIGHT INDUSTRIAL
I SUBJECT TO BUILDING DE PT.APPROVAL LOT SIZE: 3.72 ACRES Q
CITY OF TEMECUI-A PLANNING DEPT.
PROJECT rzr=ETS ZONING a TANDARDS Customer Approval: Date:
Table of Contents Landlord Approval: — Date: —
Cover Page 1 Printed Landlord's Name:
Site Plan 2 Landlord's Phone Number:
Master Criteria 2
Sign Location/Building Elevation 3 Integrat-ed
Planning Application#: Approval Date: Amended By: SIGNS
Tenant ID Sign 4 1160 Pioneer Way,Suite M,El Cajon,California 92020-1944
T:619.579.2229 1 F:619.579,7651 1 isasign.com I info•:4isasign.com
— - Door Vinyl ID Sign 5 ORIGINAL CONCEPT
This design is the exclusive property of Integiated Signs and cannot he reproduced
- - - in whole or part without their prior written consent.
Shipping & Receiving Sign 6
Scale: Sheet No.:
As Noted
3 1 A
Remington Distribution Center HAMANN
Master Sign Criteria COMPANIES
The purpose of this Master Sign Criteria for the 42006 Remington Ave,is to establish the minimum sign standards REMINGTON DISTRIBUTION
necessary to ensure coordinated proportional exposure for all tenants. CENTER
General Notes MASTER SIGN CRITERIA
A) This Master Sign Criteria shall be strictly enforced and any non-conforming signs installed by Lessee shall be
removed by the Lessee or its contractor at Lessee's sole cost and expense within ten(10)days of Lessee's receipt Project Location:
of written notice from Lessor. 42006 Remington Avenue,
B) All Lessee signage shall be consistent with ordinances and sign criteria promulgated by the City of Temecula.
Temecula,CA 92590
SIGN ID: SIGN TYPE: ILLUMINATION: DIRECTION: MAX.SZ.: SQ.FT.MAX. TENANT OR C) Each Lessee shall submit to the Lessor and City of Temecula,for approval,three(3)copies of the detailed shop
BLDG.SIGNAGE: drawingof Lessee's proposed sin in conformance with this Master Sign Criteria.Such submittal shall include, ProjectNo.:
tuf,N°'"'""°" p p sign, 161115-05
but not be limited to,pertinent dimensions,details and color call-outs.
A WALL ID NON- NORTH ELEV. 24"H 1 SQ.FT PER LINEAL TENANT
SIGN ILLUMINATED FRONTAGE D) The Lessee,at Lessee'sole cost and expense,shall pay for the fabrication,installation and maintenance of all Salesman:
signs,Broken,peeling,or missing letters and any other repairs to the Lessee's sign must be repaired within ten AC
DOOR NOW NORTH ELEV. 6"H 20%OF GLASS TENANT (10)days of Lessee's receipt of written notice from Lessor.If Lessee fails to effect the aforesaid repairs within the
VINYL ILLUMINATED LETTER AREA ten(10)days period,Lessor,at its sole and absolute discretion,but without obligation,may hire a contractor to Designer:
make the repairs and invoice the cost of these repairs to the Lessee,who will pay the cost of these repairs within Oscar L6pez
S&R NON SOUTH ELEV. 12"H 1 SQ-FT TENANT tislrty(3D) days of receipt of the Lessor's invoice.Upon the expiration of the Lease or any extension thereto,
"JJ PANEL ILLUMINATED PANEL Lessee,at tessee sale cast and expense,w vi n ill be responsible for(1)remong all an any signs installed by Lessee Date:
(2)repairing and patching any holes created by the removal of the Lessee's signs,and(3)painting the fascia or June 21,2017
other areas of the building where the sign,or signs were located to match the color of the existing paint.
Scale:
E) The Lessee shall submit to Lessor,for Lessor's review and approval,all drawings and descriptions relating to As Noted
Lessee's signs.Lessee at Lessee's sole cost and expense,shall submit all plans to all govemmental authorities for
approval and permitting prior to sign installation.
Revision:
F) Lessee's sign contractor must:(1)must have a current,in-force license from the State of California to fabricate z3 OL-revised criteria 8.24.17
signs,12)must carry current,in-force general liability insurance of not less than S1 million and(3)most carry
current,in-force workman's compensation insurance.Lessor Is to be named as additional insured for both general OL revised criteria 9.7.17
- - liability and workman's compensation insurance.All work shall be of excellent quality.Lessor reserves the right to
reject any work determined to be of inferior quality by Lessor or the project architect,in their sole and absolute
REMINGTON AVER-- �-f-�
determination.
Y G) All signs and their installation must comply with all local building and electrical codes and any government
- authority which has jurisdiction over signs.Lessee and Lessee's contractor shall independently investigate all local
B�2 A 3 A or City of Temecula sign ordinances.Lessor,nor the City shall not be liable to Lessee for any requirements not
} covered In this Master Sign CrAvia.
t - + } III
- - _ 3 } H) Lessee shall be allowed to place on the front entry door to the premises:decals,or stick-on lettering or graphics
Q Z indicating Lessee's hours of business,telephone number for emergency contact and Lessee's name
r • v 4 (See Sheet 5 for specifications). -
' '1 1) Lessee shall identify a service door for delivery and emergency purposes only.Signs shall not exceed 144 square ❑
inches.Sign to be installed by a permanent attachment(studs,silicone,etc.).
L� !
v J) Lessor,in its sole and absolute discretion,reserves the right to disapprove any sign that may conflict with the Q
! overall appearance of the Business Park.
I -"'-• Prohibited Signs --
A) Amenity signs.
Remington Distribution Center _� B) Animated or moving signs.
—+ C) Box signs.
r
D) Bunting signs.
tip
t E) Cabinet or can signs. L
l
F) Illuminated signs.
[ - G) Flashing signs. j`
0
......... - ... ... ... .._
1 C 9�4&4
H) Monument signs, Integrated SIGNS
`— � I) Blade signs.
—} J) All temporary signs are prohibited unless they are approved and permitted in accordance with Section 17.28 of
2 - �1.3-1 4 the Temecula Municipal Code or respective specific plan. Qn^. " +!_!i!_= • . =;n
i�LJ] I�LJI 7 NOTES:
J 1160 Pioneer Way,Suite M
ALL TEMPORARY SIGNS ARE PROHIBITED UNLESS THEY ARE APPROVED AND PERMITTED IN ACCORDANCE El Cajon,California 92020-1944
—� WITH SECTION 17.28 OF TEMECULA MUNICIPAL CODE.
o THE PLANING DIRECTOR SHALL HAVE THE FINAL AUTHORITY ON INTERPRETATIONS ON FONTS,COLORS, T: 619.579.2229 1 r: 619.579.7651
t 1 I I I AND LANGUAGE IN THE SIGN PROGRAM. isasign.com I info @isasign-com
ORIGINAL CONCEPT
l I I I This design is the exclusive property
of Integrated Signs and cannot be
reproduced in whole or part
SITE PLAN without their prior written consent.
SCALE: NTS
Sheet No_, "'�
. L. �6
1
GENERAL TENANT ID SIGN �HAMANN
1 ) No illuminated,animated,flashing or audible signs are COMPANIES
permitted.
2) No exposed tubing or lamps are permitted. REMINGTON DISTRIBUTION
3) Sign contractor shall provide necessary fastening and CENTER
bracing to securely install sign(for wind loads,etc.)to MASTER SIGN CRITERIA
conform to all applicable building codes and City of o _ o s
U U Project Location:
Temecula Ordinances. W = W= 42006 Remington Avenue,
4) Maximum of one(1)sign per tenant,per frontage.
z v z Temecula,CA 92590
I- V) I- V)
LQL L
A .3 TENANT ID SIGN Project No:
SIGN MUST NOT EXCEED z o z SIGN MUST NOT EXCEED (SEE SHT. 4) 161115-05
36'-6" 75%OF FASCIA AREA i'„ -O, r- 75%OF FASCIA AREA
Salesman: AC
.-TEKANT-N-AME TENANT NAME• ., Designer:
- - - - --- — k Oscar Lopez
- -
f Date: June 21,2017
j( r I Scale: As Noted
Revision:
Y ❑3 OL-revised criteria 8.24.17
® OL-revised criteria 9.7.17
4-F
'_ ❑i 1r _
Il ❑ _
SIGN AREA= ONE(1)SQ. FT. FOR EVERY ONE(1)LINEAR FT. OF FRONTAGE. _ DOOR VINYL GRAPHICS
B .4 DOOR VINYL GRAPHICS A .4 TENANT ID SIGN - - _
(SEE SHT. 5) (SEE SHT.4) (SEE SHT. 5) ❑
of c�
U l7
xW uL ❑
� _ LU
oa_
z U
A .2 TENANT ID SIGN Z —d ly )A TENANT ID SIGN
G a SIGN MUST NOT EXCEED a ��
LL (SEE SHT.4) _ SIGN MUST NOT EXCEED (SEE SHT.4) 0
2 0 75%OF FASCIA AREA 0 75%OF FASCIA AREA
zo zo
LD Ln ,,, - -
'� r- 37' 0"
LL
TENANT NAME _ 'TENANT-NAME?i
_ � J
Integrated SIGNS
IL 1160 Pioneer Way,Suite M
ELMO El Cajon,California 92020-1944
T
Y - - - T:619.579.2229 I F:619.579.7651
I I `-�, ^i t isasign.com I info @isasign.com
ORIGINAL CONCEPT
[T.2 DOOR VINYL GRAPHICSSIGN AREA= ONE(1)SQ. FT. FOR EVERY ONE(1) LINEAR FT. OF FRONTAGE. This design is the exclusive property
(SEE SHT. 5) B .� (00 SHT.
VINYL GRAPHICS of Integrated Signs and cannot be
reproduced in whole or part
without their prior written consent.
NORTH ELEVATION
Sheet No.:
SCALE: 1/16" = 1'-0"
3
/6
..HAMANN
WALL SIGN (TENANT,TYPICAL) COMPANIES
EXTERIOR WALL 4 — EXTERIOR WALL REMINGTON DISTRIBUTION
WALL SIGN: TENANTS ARE TO HAVE NON ILLUMINATED LOGO/LETTERS FOR CENTER
BUSINESS FRONTAGE WALL SIGNS. MASTER SIGN CRITERIA
112"THK.FC.O.ACRYLIC Project Location:
LETTERS/LOGO CONSTRUCTION
1" DP.HUD SIGN FOAM MATERIAL: OPTION "A" 42006 Remington Avenue,
LETTERS/LOGO W/PAINTED 1/2"THK.FCO ACRYLIC LETTTER/LOGO W/PAINTED FINISH. Temecula,CA 92590
FINISH OPTION "B"
1" DP.H.U.D.FCO SIGN FOAM LETTTER/LOGO W/PAINTED :Project No-
IMBEDDED NUTSERTS FINISH. 161115-05
-00 (TYPICAL)
ILLUMINATION: NON-ILLUMINATED. Salesmen: AC
SILICONE ADHESIVE AS
NON-CORROSIVE REQUIRED LETTERS/LOGO Designer:
THREADED STUDS �.. DESIGN: THE "COPY"(LETTER TYPE),LOGOS AND THEIR RESPECTIVE Oscar Lopez
COLORS SHALL BE SUBMITTED TO THE OWNER FOR WRITTEN Date:
MOUNTING HOLES I' APPROVAL PRIOR TO FABRICATION.IN ADDITION TO THE COLORS June 21,2017
DRILLED&FILLED WIl. LISTED BELOW,COLOR SCHEMES FOR REGIONALAND NATIONAL scale:
SILICONE ADHESIVE ' TENANTS AND TRADEMARKED LOGOS SHALL BE PERMITTED As Noted
I. (SUBJECT TO PRIOR LESSOR'S APPROVAL).
1 FONT: TENANT WITH NO CUSTOM LOGO&LETTERS MAY USE ONLY Revision:
THE APPROVED FONT (HELVETICA BOLD),CAPITAL LETTERS Q OL-added foam option 7.7.17
ONLY. ® OL-revised criteria 9.7.17
COLORS: RED(PMS 485C),BLUE(PMS 281C),GREEN(PMS 349C),
NON-ILLUMINATED FCO LETTERS - DETAIL A NON-ILLUMINATED HUD FOAM LETTERS - DETAIL A YELLOW(PMS 109C),PMS BLACK, A
SCALE:NTS SCALE:NTS A
INSTALL: SURFACE MOUNTED TO EXTERIOR WALL W/STUDS&SILICONE 0
ADHESIVE AS PER SECTION DETAIL.
NO MORE THAN ONE ROW OF LETTERS SHALL BE PERMITTED.
OPTION "All OPTION "B" NOTES: 0
ALL TEMPORARY SIGNS ARE PROHIBITED UNLESS THEY ARE APPROVED AND
PERMITTED IN ACCORDANCE WITH SECTION 17.28 OF TEMECULA MUNICIPAL
CODE OR SPECIFIC PLAN. Q
THE PLANING DIRECTOR SHALL HAVE THE FINAL AUTHORITY ON INTERPRETATIONS
ON FONTS,COLORS,AND LANGUAGE IN THE SIGN PROGRAM.
0
A 0 -
I A
-- -- -------- ------- -----T -----
Q
0
MEMO Integrated SIGNS
- -
I
PMS BLACK C RED(PMS 485C) BLUE(PMS 281 C) GREEN(PMS 349C) YELLOW(PMS 109C)
1160 Pioneer Way,Suite M
El Cajon,California 92020-1944
APPROVED COLORS T:619.579.2229 1 F:619.579.7651
TENANT SIGNAGE: isasign.com I info @isasign.com
MAXIMUM LOGO HEIGHT=24" HEIGHT
MAXIMUM LETTER HEIGHT=24' HEIGHT
ORIGINAL CONCEPT
This design is the exclusive property
of Integrated Signs and cannot be
reproduced in whole or part
TENANT ID SIGN - NON-ILLUMINATED FCO LETTERS/LOGO) without their prior written consent-
SCALE: 3/8" = V-0" SheetNo.:
4 /6
QH�II�ANN.
SIGN TYPES: COMPANIES
LETTERSTYLE:ALL LOGOSTYLES ARE ACCEPTABLE. REMINGTON DISTRIBUTION
UPPER OR LOWER CASE COPY IS PERMITTED. CENTER
ALLTRADEMARKED LOGOS WILL BE PERMITTED TO MASTER SIGN CRITERIA
USE THEIR REGISTERED LOGO.
ANY COLOR COMBINATION IS PERMITTED. Project Location:
42006 Remington Avenue,
SIZE RESTRICTIONS: Temecula,CA 92590
LETTERING ON THE DOORANDWINDOWS NOTTO
EXCEED 20%OF INDIVIDUAL GLAZED AREA. Project No:
LETTERING NOT TO EXCEED SIX(6)INCHES IN LETTER 161115-05
HEIGHT.
Salesman AC
L OF DOOR NOTES:
ALLTEMPORARY SIGNS ARE PROHIBITED UNLESSTHEY Designer:
ARE APPROVED AND PERMITTED IN ACCORDANCE WITH Oscar Lopez
SECTION 17.28 OFTEMECULA MUNICIPAL CODE OR Date June 21,2017
SPECIFIC PLAN.
THE PLANING DIRECTOR SHALL HAVE THE FINAL Scale:
AUTHORITY ON INTERPRETATIONS ON FONTS, As Noted
COLORS,AND LANGUAGE IN THE SIGN PROGRAM.
Revision:
--—————————
I
! Q
5'-0"AFF TrNANT NAME !
---- i,mrTO EXCEED 20°la
of GLAZED AREA)
I � Q
——r ,+ —
Q
2' 8"AFF —
0
Q —
Integrated SIGNS
DREANN IT- BUILD IT- SIGN IT
1160 Pioneer Way,Suite M
El Cajon,California 92020-1944
T:619.579.2229 1 F:619.579,7651
isasign.com I info @isasign.com
ORIGINAL CONCEPT
This design is the exclusive property
TYPICAL DOOR VINYL GRAPHICS of Integrated Signs and cannot be
reproduced in whole or part
SCALE: 3/4" = 1 '-0" without their prior written consent.
SheetNo.:
5 /6
HAMANN
SIGN TYPES: COMPANIES
LETTERSTYLE:ALL LOGOSTYLES ARE ACCEPTABLE. REMINGTON DISTRIBUTION
UPPER OR LOWER CASE COPY IS PERMITTED. CENTER
ALLTRADEMARKED LOGOS WILL BE PERMITTED TO MASTER SIGN CRITERIA
USE THEIR REGISTERED LOGO.
ANY COLOR COMBINATION IS PERMITTED. Project Location:
42006 Remington Avenue,
SERVICE DOOR ENTRANCE CAN BE LABELED WITH AN Temecula,CA 92590
.090"THK.ALUMINUM PANEL,PAINTED WHITE,WITH
BLACK LETTERING
161115-05
SIZE RESTRICTIONS:
SERVICE DOOR ENTRANCE NO TO EXCEED 144 INCHES. Salesman: AC
NOTES: Oscar Lopez
ALLTEMPORARY SIGNS ARE PROHIBITED UNLESS THEY
ARE APPROVED AND PERMITTED IN ACCORDANCE WITH Date:
June 21,2017
SECTION 17.28 OF TEMECULA MUNICIPAL CODE OR
SPECIFIC PLAN. Scale: AS Noted
THE PLANING DIRECTOR SHALL HAVE THE FINAL
1*On AUTHORITY ON INTERPRETATIONS ON FONTS, Revision:
COLORS,AND LANGUAGE IN THE SIGN PROGRAM.
0
0
ZL
Q
TENANT NAME E . EQ. Z
�1 °
0
o _ _
4
HIPPIN 5' 6"AFF -
�,s.a
RECEIVING
Integrated SIGNS
1160 Pioneer Way,Suite M
El Cajon,California 92020-1944
T:619.579.2229 1 F:619.579.7651
isasign.com I info @isasign.com
ORIGINAL CONCEPT
This design is the exclusive property
JF ALUMINUM "SHIPPING & RECEIVING" PANEL of Integrated Signs and cannot be
reproduced in whole or part
SCALE: 3" = 1 '-0" without their prior written consent.
Sheet No.:
6 /6