HomeMy WebLinkAboutTract Map 3752 Temecula Medical Center Geotechnical Investigation_ PROFESSIONAL ENGINEERS CONSULTING, Inc. GEOTECHNICAL ENVIRONMENTAL TESTING INSPFCTION 25422 Trnhuco Rd. 4105 Luke Forest, C4 92630 Phone 949-768-3693 info a'pes'niLann 27636 Yne:Road.k L7 Temecula, CA 92591 Phone 951-698-4598 wIvw.pesoiLeom GEOTECHNICAL INVESTIGATIONS SITE: Pacific Media Properties„ 31775 De Portola Road Temecula, CA 92592 DATE: April 19, 2014 Project Number: PM0414 PREPARED FOR: Pacific Media Properties Mr. Warren Owens PO Box 2248 Orange, CA 92859 PROFESSIONAL ENGINEERS CONSULTING, Inc. GEOTECHNICAL ENVIRONMENTAL TESTING INSPECTION 25421 Trabuco Rd. #105 Lake Forest. CA 92630 Phone 949-768-3693 injoCa'pesoiLeom 27636 Ynez Road, H L7 Temecula, CA 92591 Phone 951-698-4598 uvIrir.pesoiLcom April 19. 2014 Mr. Warren Owens Pacific Media Properties PO Box 2248 Orange, CA 92859 Dear Mr. Owens: Professional Engineers Consulting, Inc. is pleased to present you this soil report for your project located at 31775.De Portola Road, Temecula. CA 92592. Based on the actual site condition, laboratory analyses, and our field observations, we are providing you a summary of geotechnical studies. It is our opinion that the enclosed conclusions and recommendations can be used for the design and construction of this project. This opportunity to be of professional service is greatly appreciated. Should you have any questions or require additional information, please do not hesitate to contact our office at 949-768-3693. Respectfully Submitted, PROFESSIONAL ENGINEERS CONSULTING, Inc. / QpOFESS/O p W No.51711 m r Exp. 6I33014 zo `P'l CIVIL FOF CA1.IF� Saeed Shahidi Registered Civil Engineer PROFESSIONAL ENGINEERS CONSULTING, Inc. TABLE OF CONTENTS INTRODUCTION I SCOPE OF WORK I SITE LOCATION&DESCRIPTION I PROPOSED DEVELOPMENT 2 LIQUEFACTION CONDITIONS 2 SEISMICITY&FAULTING 3 GEOTECHNICAL INVESTIGATION 4 FIELD STUDY 4 LABORATORY TESTING 4 ATTERBERG LIMITS 4 SOIL CLASSIFICATION 5 PARTICLE SIZE ANALYSES 5 R-VALUE 6 FIELD OBSERVATION 6 CONCLUSIONS AND RECOMMENDATIONS 6 FOUNDATION DESIGN RECOMMENDATIONS 7 ALOWABLE FOUNDATION PRESSURE 8 LATERAL RESISTANCE 9 SETTLEMENT 9 EARTHWORK AND GROUND PREPARATION 9 IMPORTED SOIL 10- FILL PLACEMENT&TESTING I I EFFECT OF GRADINFG ON ADJOINING PROPERTIES I I POST-GRADING CONSIDERATION 12 PAD DRAINAGE 12 UTILITY TRENCH BACKFILL 12 SITE CLEARING 13 FOOTING OBSERVATION 13 SOLUBALE SULFATE;CONCRETE TYPE 13 MASONARY GARDEN WALLS 13 EXTERIOR CONCRETE FLATWORK 14 REINFORCEMENT 14 SUBGRADE PREPARATION 14 EDGE BEAMS 15 FUTUREIMPROVEMENT 15 CONCRETE AND ASPHALT PAVEMENTS 16 PRELIMINARY ASPHALTIC CONCRETE PAVEMENT DESIGN 16 STRUCTURAL PAVEMENT SECTION 17 4 f' PROFESSIONAL ENGINEERS CONSULTING, Inc. TABLE OF CONTENTS (Continued..........) GEOTECHNICAL OBSERVATION AND TESTING 18 LIMITATIONS 19 APPENDIX A FIGURES I. SITE LOCATION 2. SITE MAP-SAMPLING LOCATIONS, 3. SEISMIC HAZARD MAP 4. GEOLOGIC MAP APPENDIX B TRENCH LOGS APPENDIX C SUMMARY OF LABORATORY ANALYSIS PROFESSIONAL ENGINEERS CONSULTING, Inc. Soil Report PadAc Media Properties 31775 De Portola Road, Temecula, CA 92592 Project Number:PM0414 Page I of 19 INTRODUCTION This report was prepared by Professional Engineers Consulting, Inc. to provide geotechnical investigation for the construction of a,medical building facility within the lot located at 31775 be Portola Road, Temecula, CA 92592. See figures 1 & 2. The scope of this study is designed to determine and evaluate the surface and subsurface conditions on the subject site and to present preliminary recommendations for the foundation systems, structural design, and grading requirements for the building and the parking area. SCOPE OF WORK • Placing four exploratory trenches, logging, soil sampling and preparation for the purpose of laboratory testing, engineering design recommendations, and analyses. • Laboratory testing of selected soil and/or bedrock samples, including visual classification • Preparation of a report presenting our findings, conclusions, and geotechnical recommendations for the type of foundation, structural design, seismic design, parking lot section, and grading procedures. • Providing seismic design values and recommendations SITE,LOCAT/ON& DESCRIPTION The subject lot is within the City of Temecula at approximately two miles east of 15 Freeway. The area in general is developed with residential and commercial structures. Currently, the site is vacant L 5 PROFESSIONAL ENGINEERS CONSULTING, Inc. Sol/Report PadAc Media Propert/es 31775 De Portola Road, Temecula, CA 92592 Project Number. PM0414 Page 1 of 19 PROPOSED DEVELOPMENT The lot is going to be used for the construction a medical center. Structures are to be supported on -continuous and isolated pad footing type foundations. Loads on the foundations are unknown but are not anticipated to exceed 50 kips per linear foot for column loads. The proposed floors could consist of continuous concrete slabs placed on finish grade and supported by footings. Finished floor elevations will be anticipated to have approximately- + 2 % gradient from the street level and also in accordance with the city of Temecula design standards. Surface drainage will be controlled by sloped concrete flatwork earth swales and area drains will be designed to carry surface water to drain outside the property. Currently architectural and engineering plans are not finalized. Therefore, our conclusions are preliminary and subject to modification. - Should details involved in final design vary from those outlined above, this firm should be notified for review and possible revision of our recommendations. Otherwise we cannot take any responsibility. LIQUEFACTION CONDITIONS Liquefaction can occur when saturated loose and fine granular soils are subjected to excessive ground vibrations or exposure to groundwater. Per "Public Safety Element" publication issued by the city of Temecula, the site is within the area with liquefaction potential as shown on Figure 3. The subsurface mainly consists of sandy silty soil material with some thin layers of clay. Groundwater was not encountered during our investigations. Additional liquefaction study may be needed based on the city of Temecula standards. PROFESSIONAL ENGINEERS CONSULTING, Inc. Soil Report Paddle Media Properties 31775 De Portola Road, Temecula, CA 92592 Project Number:PM0414 Page 3 of 19 SEISMICITY and FAULTING PER 48 States, 2005 ASCE 7 Standard for Latitude = 33.4, Longitude = -117.1 Spectral Response Accelerations Sr and Sl Ss and SI = Mapped Spectral Acceleration Values Site Class D - Fa .= 1.0 ,Fv = 1.0 Data are based on.a 0.01 deg grid spacing, Period Sa (sec) (g) 0.2 1.765, (Ss, Site Class D) I.0 0:632 (SI, Site Class Dj Spectral Response ACcelerationS.3Ms and SMI ;SMs = Fa x Ss and SMI = Fv x S1 Site Class D - Fa = 1.0 ,Fv = 1.5 Period Sa (sec) (g) 0.2 1.765 (SMs, Site Class D) 1.6 0:948 (SMI, Site Class D) Design Spectra/Response Accelerations SDs and SDl SDs'= 2/3 x SMs and SDI = 2/3 x SMI Site Class D - Fa = 1.0 ,Fv = 1.5 Period Sa (sec) (g) 0.2 1.176 (SDs, Site Class D) 1.0 0.632 (SDI, Site Class D) PROFESSIONAL ENGINEERS CONSULTING, Inc. Soil Report Pacific Media Properties 31775 De Portole Road, Temecula, CA 92592 Project Number:PM0414 Page 4 of 19 GEOTECHN/CAL INVEST/CATIONS FIELD STUDY Geotechnical, field studies consisting of site observations and subsurface exploration were started on April 8, 2014, by placing total of four trenches to depths of 10 feet to verify the subsurface conditions. . Our Registered Civil - Engineer the encountered formations. The trench logs are included in Appendix 'B'. Approximate locations of Trenches are shown on Figure 2. Undisturbed samples of the soils were obtained at selected intervals. Undisturbed samples were obtained by driving a thin walled steel sampler with successive drops of a 25-pound weight having a free fall of 18 inches. Undisturbed soils were retained in close fitting moisture proof containers and transported to our,laboratory. Grab samples were also taken to perform geotechnicaI laboratory tests. The exploratory trenches used for subsurface exploration were backfilled with the native soil and with reasonable effort to restore the area to its original condition. LABORATORY TESTING Laboratory analyses were performed per ASTM Standards. ATTERSERC LIMITS(ASTM D 4318) The sample is processed to remove any material retained on a 425-um (No. 40) sieve. The Liquid Limit is determined by performing trials in which a portion of the sample is spread in a brass cup, divided in two by a grooving tool, and then allowed to Flow together from the shocks caused by repeatedly dropping the cup in a standard mechanical device. The multipoint liquid limit, Method A, requires three or more trials PROFESSIONAL ENGINEERS CONSULTING, Inc. Soil Report Pad&Medla Properties 31775 De Portola Road, Temecula, CA 92592 Project Number:PM0414 Page 5 of 19 over a range of water contents to be performed and the data from the trial plotted or calculated to make a relationship from which the liquid limit is determined. The one-point liquid limit, method B, uses the data from two trials at one water content multiplied by a correction factor to determine the liquid limit. The Plastic Limit is determined by alternatively pressing together and rolling into a 3.2 mm diameter thread a small portion of the plastic soil until its water content is reduced to a point at which the thread is crumbles and can no longer be pressed together and rolled. The water content of the soil at this point is reported as Plastic Limit. Plasticity Index is the difference between Liquid and Plastic Limit. 5O1L CLASSIFICAT/ON The field classification of the soils was verified in the laboratory in general accordance with the Unified Soil Classification System. The final classification is shown on the trench logs. PARTICLE SIZE ANAL Y51S The procedure is repeated for a sufficient number of water contents to establish a relationship between the dry unit weight and the water content of the soil. This data, when plotted, presents a curvilinear relationship known as the compaction curve. The values of optimum water content and modified maximum dry unit weight are determined from the compaction curve. A specimen of the soil is washed over a 75-um (No. 200) sieve. Clay and other particles that are dispersed by the wash water, as well as water-soluble materials, are removed from the soil during the test. The loss is mass resulting from the wash treatment is calculated as mass percent of the original sample and is reported as the percentage of material finer than a 75-um (No. 200) sieve by washing. PROFESSIONAL ENGINEERS CONSULTING, Inc. Sol/Report Padfic Media Properties 31775 De Portola Road, Temecula, CA 92592 Project Number:PM0414 Page 6 of 19 R-VALUE This test method covers the procedure for testing both treated and untreated laboratory compacted soils or aggregates with the stabilometer and expansion pressure devices to obtain .results indicative of performance when placed in the base, subbase, or subgrade of a road subjected to traffic. It is used to determine the structural section of asphalt concrete pavement. FIELD OBSERVATION Based on field observations from the samples obtained from the four 10 feet deep trenches, we can present the following: The subsurface consisted of partially disturbed soil within the top 2.5 feet, mainly from demolishing the old structures. Some random debris of rubbles were observed within this depth. This layer was underlain by dense sandy silty soil, becoming very dense at 5 feet. This unit consists of fine-grained floodplain deposits, mainly sands, silts, and some clay. These sediments are unconsolidated on the upper few feet. they are typically dense at lower depths. Generally, the subsurface of the site consists of young alluvium (map symbol: Qya). Groundwater was not encountered in our trenches. CONCLUSIONS AND RECOMMENDATIONS It is our opinion that subject property can be developed by using conventional and deepened footings with grade beams and slab-on-grade floors, provided that our enclosed conclusions and recommendations are implemented into the design criteria and project specifications. 1 PROFESSIONAL ENGINEERS CONSULTING, Inc. Soil Report Pad&Media Properties 31775 De Portola Road, Temecula, CA 92592 Project Number: PM0414 Page 7 of 19 However, our conclusions at this time are preliminary and are subject to review and modification after reviewing the final plans and design specifications. FOUNDATION DESIGN RECOMMENDATIONS • All exterior-building footings should be founded at a minimum depth of 24 inches below the lowest adjacent final grade. Interior footings may be founded at a minimum depth of 24 inches below the lowest adjacent final grade. This value is applicable for a 2 story building. Extra 12 inches of,depth"will be required for each additional story. • Continuous footings should be reinforced with 4 No. 4 bars, 2 at every one foot. • Exterior isolated pad footings intended for support of roof overhangs such as patio covers should be a-minimum of 24 inches square, and founded at a minimum depth of 48 inches below the lowest adjacent final grade. The pad footings should be reinforced with No. 4 bars spaced 18 inches on centers, both ways, near the bottoms of the footings. • Living area concrete Floor slabs should be a full 5 inches thick an underlain with 3 inches of clean sand or gravel. All slabs should be reinforced with No. 3 bars spaced 18 inches on centers, both ways. All slab reinforcement should be supported on concrete chairs or bricks to ensure the desired placement near mid depth. Rebars should be No. 3 and spaced 18 inches • Living area Floor slabs should be underlain with a moisture vapor barrier consisting of a polyvinyl chloride membrane such as 6 mil Visqueen, or equivalent, placed on top of the 2-inch sand. At least 2 inch of clean sand should be placed over the membrane to promote uniform curing of the concrete. PROFESSIONAL ENGINEERS CONSULTING, Inc. Soil Report Red&Media Properties 31775 De Portola Road. Temecula, CA 92592 Project Number: PM0414 Page 8 of 19 • Garage floor slabs should be a full 5 inches thick and underlain with 4 inches of clean sand or gravel. Garage and parking slabs should be reinforced in a similar manner as living area slabs and poured separately from adjacent wall footings with a positive separation maintained with 3/8-inch minimum felt expansion joint materials, and then quartered with weakened plane joints. A 12-inch wide by 24- inch deep grade beam should also be provided across garage entrances. The grade beam should be reinforced with four No. 4 bars, two top and two at every one foot. • Prior.to placing concrete, the subgrade below all living area and garage slabs should be presoaked to achieve a moisture content that is 30 percent_ or greater above optimum moisture content.. This moisture content should penetrate to a minimum depth of 12 inches into the subgrade ALLOWABLE FOUNDAT/ON PRESSURE The allowable foundation pressure value is 1,500 psf for footings having a minimum width and depth of 12 inches. An increase of twenty percent shall be allowed for each additional foot of width of depth to a maximum value of three times the designated value. Additionally, an increase of one third shall be permitted when considering load combinations including wind or earthquake loads. The above values are based on footings placed directly against compacted fill. In the case where footing sides are formed, all backfill against footings should be compacted to at least 90 percent of maximum dry density.. PROFESSIONAL ENGINEERS CONSULTING, Inc. Sol/Report Pacific Media Properties 31775 De Porto/a Road, Temecula, CA 92592 Project Number:PM0414 Page 9 of 19 LATERAL RESISTANCE A passive earth pressure of 150 pounds per square foot per foot of depth may be used to determine lateral bearing resistance for footings. Lateral sliding resistance coefficient should'be 0.25. The above values are based on footings placed directly against bedrock or compacted fill. In the case where footing sides are formed, all backfill against footings should be compacted to at least 90 percent of maximum dry density. SETTLEMENT The majority of total and differential settlements are expected to occur during construction or shortly thereafter as building loads are applied. However, should there be any ground shaking, some small seismically induced settlements may occur. Due to the fact that the site is within an area with the potential for liquefaction, we recommend a conservative approach by the structural engineer and performing liquefaction study to determine proper value for the settlement. EARTHWORK AND GROUND PREPARATION All earthwork and grading should be performed in accordance with all applicable requirements of the grading code of the city of Temecula, California, and the recommendations provided below: • .For any area used for structure, surface must be over-excavated for a minimum of 4 feet below the existing grade and recompacted for 90% of laboratory maximum density. The overexcavation must be extended to a minimum of 5 feet beyond the boundaries. e PROFESSIONAL ENGINEERS CONSULTING, Inc. Soll Report Pad&Medla Properties 31775 De Portola Road, Temecula, CA 92592 Project Number:PM0414 Page 10 of 19 • For any area used for parking, surface must be over-excavated for a minimum of 2.5 feet below the existing grade and recompacted for 90% of laboratory maximum density. The overexcavation must be extended to a minimum of 5 feet beyond the boundaries. • Prior to placing fill, all areas to receive fill should first be scarified, watered or air dried as necessary to achieve near optimum moisture conditions, and then recompacted in-place for 90%. • For proposed driveway and parking subgrade areas, all base material shall be compacted for 95% of laboratory maximum density. • The soil must be moisture conditioned to achieve no more than 3% higher than optimum moisture content. • Fill soils shall be, placed in 8-inch lifts; moisture conditioned and compacted to the required level of compaction. • All significant weeds or rootlets should be stripped and removed offsite. • All cobbles and gravels over 8" diameter must be removed from the pad or any backfilling area. • Stockpile soil materials that are to be used as fill should be cleared of any unsuitable materials prior to placement as properly compacted fill. IMPORTED SOILS Imported soils should consist of clean materials void of trash, organic and similar deleterious materials, and rock exceeding a maximum dimension of 8 inches. PROFESSIONAL ENGINEERS CONSULTING, Inc. Aoll Report PadAc Media Propertler 31775 De Portola Road, Temecula, CA 92592 Project Number:PM0414 Page 11 of 19 The imported soil should also exhibit an expansion potential of low expansion, as determined in accordance with UBC Standard Test No. 29-2. A representative of this firm should approve prospective import soils before transporting to, the site. The grading contractor should accommodate sufficient time for performing the above tests, prior to importing soil materials. FILL PACEMENTAND TESTINC All fills should be placed in 8-inch-thick maximum lifts, watered or air-dried as necessary to achieve near optimum moisture conditions, and then compacted in-place to a minimum relative compaction of 90% for the pads and 95% for the base material for driveway and parking areas. The laboratory maximum dry density and optimum moisture. content for each change in soil type should be determined in accordance with Test Method ASTM D 1557-91. A representative of this firm should be present onsite during grading operations to verify proper placement and adequate compaction of all fills, as well as to verify compliance with the other geotechnical recommendations presented herein. EFFECTS OF GRADING ON ADJOINING PROPERTIES Based on our site observation, the proposed grading and construction will not adversely affect the geotechnical stability of adjoining properties provided that grading and construction are performed in accordance with the recommendations presented herein. PROFESSIONAL ENGINEERS CONSULTING, Inc. Soll Report Pad&Media Properties 31775 De Portola Road, Temecula, CA 92592 Project Number: PM0414 Page 12 of 19 Should there be any anticipation regarding this issue, it will be the responsibility of the grading contractor to contact our firm and the owner before starting the job or during the construction. Otherwise we can not take any responsibility. POST-GRAD/NC CONSIDERATIONS PAD DRAINAGE Positive drainage devices consisting of sloped concrete flatwork, area drains, and graded earth swales have been designed for the site. The purpose of these devices is to reduce water infiltration into the subgrade, and to, direct surface waters .away from building foundations, walls and sloped areas. The homeowner is advised that all drainage devices should be properly maintained throughout the lifetime of the development. UTILITY TRENCH BACKFILL All utility trench backfill should be compacted to a minimum relative compaction of 90 percent. Trench backfill materials should be placed in lifts no greater than 8 inches in thickness, watered or air dried as necessary to achieve a moisture content that is 2 to 3 points over optimum moisture content,.and then mechanically compacted in place to a minimum relative compaction of 90 percent. Where exterior and/or interior utility trenches are proposed parallel to any building footing, the bottoms of these trenches should not extend below a 1:1 plane projected downward from the bottom edge of the adjacent footing. Where this condition occurs, the adjacent footing should be deepened or the utility constructed and backfilled prior to constructing the footing. A representative of this firm should be notified 48 hours in advance to verify adequate compaction of the backfill. PROFESSIONAL ENGINEERS CONSULTING, Inc. Sol/Report PadAc Media Properties 31775 De Portola Road, Temecula, CA 92592 Project Number: PM0414 Page 13 of 19 SITE CLEARING All soil, vegetation, and rock debris excavated from stripping and foundation trenches are to be disposed offsite in a proper manner. This also includes refuses such as bushes, organic material, stumps and construction debris. No debris or reject materials from the excavations are to be placed on the slope behind the retaining walls or used as backfill. FOOTING OBSERVAT/ONS All footing trenches should be observed by a representative of this firm to verify that they have been excavated into competent bearing materials. These observations should be performed prior to the placement of forms, reinforcement, or concrete. The excavations should be trimmed neat, level.and square. All loose, sloughed or moisture- softened soils and/or construction debris should be removed prior to the placement of concrete. Excavated soils derived from footing and utility trenches should not be placed in slab-on-grade areas unless they are compacted to at least 90 percent of maximum dry density. SOLUBLE SULFA TE A NA L YSES Per UBC standards, type V cement with 2,500 psi and 0.5 water content ratio is recommended. MASONRY GARDEN WALLS Footings for masonry garden walls on level ground should be embedded at a minimum depth of 12 inches below the lowest competent soil material. All footings should also be reinforced with a minimum of four No. 4 bars, two top and two bottom. In order to mitigate the potential for unsightly cracking related to the possible effects of differential settlement and/or expansion, construction joints should also be provided in the garden walls at each corner and at horizontal intervals of at. PROFESSIONAL ENGINEERS CONSULTING, Inc. Soil Report Pad&Media Properties 31775 De Portola Road, Temecula, CA 92592 Project Number:PM0414 Page 14 of 19 least 20 feet. The separation should be provided in the blocks and not extend through the footings. The footings should be poured monolithically with continuous rebars to serve as effective "grade beams" below the walls. EXTERIOR CONCRETE FLA TWORK To reduce the potential of unsightly cracking related to the effects of soils, concrete sidewalks and patio-type slabs should be at least 4 inches thick and provided with saw cuts or expansion joint every 6 feet or less. Concrete driveway slabs should be at least 6 inches thick and provided with saw cuts or expansion joints every 10 feet or less. REINFORCEMENT Consideration should be given to reinforcing all concrete patio-type-slabs, driveways and sidewalks greater than 5 feet in width with No. 3 bars spaced 18 inches on centers, both ways. The reinforcement should be positioned near the middle of the slabs by means of concrete chairs or brick. All cold joints should be provide with dowels consisting of No. 3 bars, 24 inches in length, and spaced 18 inches on center. SURCRADE PREPARATION As a further measure to mitigate cracking and/or shifting of concrete flatwork, the subgrade soils below concrete flatwork should be thoroughly moistened prior to placing concrete. The moisture content of the soils should be about 130 percent of optimum moisture content and penetrate to a depth of approximately 12 inches below the bottom of the slabs. PROFESSIONAL ENGINEERS CONSULTING, Inc. Soil Report Pad&Medla Properties 31775 De Portola Road, Temecula, CA 92592 Project Number:PM0414 Page 15 of 19 EDGE BEAMS Where the outer edges of concrete flatwork such as patios and driveways are to be bordered by landscaping, consideration should be given to the use of edge beams (thickened edges) to mitigate infiltration of water under the slabs. Edge beams should be 6 to 8 inches wide, extend 12 inches below the tops of the finish slab surfaces, and be reinforced with a minimum of two No. 4 bars, one top and one bottom. FUTURE IMPROVEMENTS Should any new structures or improvements be proposed at any time in the future other than those shown on the enclosed site plan and discussed herein, our firm should be notified 'so that we may provide design recommendations to maintain the integrity of the new improvement. Potential problems can develop when drainage on the pad is altered in any way (i.e., excavations or placement of fills associated with construction of new walkways, patios, garden walls and planters). Therefore, it is recommended that we be engaged to review the final design drawings, specifications and grading plan prior to any new constructions. If we are not given the opportunity to review these documents with respect to the geotechnical aspects of new construction and grading, we can take no responsibility for misinterpretation of our recommendations presented herein. PROFESSIONAL ENGINEERS CONSULTING, Inc. Soil Report Fad&Media Properties 31775 De Portola Road Temecula, CA 92592 Project Number:PM0414 Page 16 of 19 CONCRETE AND ASPHALT PAVEMENTS PRELIMINAR YASPHAL TIC CONCRETE PAVEMENTDESIGN Following Asphaltic concrete pavement sections have been computed in accordance with the State of California design procedures.. Subgrade soil immediately below the aggregate base (base) should be compacted to a minimum of 90 percent relative compaction based on ASTM Test Method D1557 to a minimum depth of 24 inches. Final subgrade compaction should be performed prior to placing base or Asphaltic concrete and after all utility trench backfills have been compacted and tested. Base materials should consist of Class.2 aggregate base ( not miscellaneous) conforming to Section 26-1.02B of the St California Standard Specifications or crushed aggregate base . conforming to Section 200-2 of Standard Specifications for Public Works Construction (Greenbook). Base materials should be compacted to a minimum of 95 percent relative compaction based on ASTM Test Method 0157. The base materials should be at or slightly below optimum moisture content when compacted. Asphaltic concrete materials and construction should conform to Section 203 of the Greenbook. PROFESSIONAL ENGINEERS CONSULTING, Inc. foll Report Pad&Media Properties 31775 De Portola Road, Temecula, CA 92592 Project Number:PM0414 Page 17 of 19 STRUCTURAL PAVEMENT SECTION TI = 5 R-Value 62 AC.thickness: 4 inches minimum Road Base Thickness: 6 inches minimum R value and additional verification for the TI The following are our recommendation for the structural pavement sections: Based on the onsite soil condition, 2.500 psi and Type V cement and 0.45 water cement ratio shall be used in concrete. All joints (longitudinal, construction and expansion) should be in accordance with current specifications. Currently due to changeability of the onsite soil during the grading and also possibility of importing soil, the R- Value and sulfate tests on the soil for the pads, driveways, and parking areas will be subject to some modification. In order to obtain a proper concrete type and pavement design, we recommend performing confirmatory R- Value and sulfate test during grading the pads and parking area, followed by TI and pavement section design. PROFESSIONAL ENGINEERS CONSULTING, Inc. Soll Report Padflc Media Properties 31775 De PorMle Road, Temecula, CA 92592 Project Number: PM0414 Page 18 of 19 GEomcw/CAL OBSERVAT/ON 6 TEST/NG Several observations, site inspections, meetings, and testing will be required throughout the construction, followings are the typical items: o Pre-construction meeting. o Bottom inspection of all overexcavations. o During the compaction of overexcavated area and the precise grade. o Footing excavations, prior to the pouring of concrete. o After presoaking the slabs upgrade and prior to pouring concrete slabs: o During the construction of area drain and utility trenches. o During the placement of subgrade for parking and driveways. o During the placement of the base material for the parking and driveway. o When any unusual conditions are encountered during any construction operation subsequent to this report. All inspections are subject to a minimum of prior 24 hours notice (within working day period). Pre-grade meeting is subject to a minimum of two working days notice. To avoid any possible delays or misinterpretations, a representative of our firm must be notified to attend the pre-construction meeting with the grading contractor and city inspector to review the grading plans and the soil report and site condition and discuss potential changes prior to proceeding grading. We cannot take any responsibility for changes if we are not given the opportunity to attend the pregrade meeting and also review the grading plans and foundation plans prior to the construction. PROFESSIONAL ENGINEERS CONSULTING, Inc. Soil Report Pad&Medla Properties 31775 De Portola Road, Temecula, CA 92592 Project Number: PM0414 Page 19 of 19 LIMITATIONS The geotechnical assessment activities presented in this report have been conducted in accordance with current practice and the standard of care exercised, by geotechnical consultants performing similar tasks in this area. No warranty, expressed or implied, is made regarding the conclusions, professional opinions, and recommendations expressed in this report. The conclusions. are based solely upon an analysis of the conditions as observed by our personnel and as reported to use by regulatory agencies and other named sources are and also based on surface and subsurface conditions present and our present state of geotechnical knowledge. They are not meant to imply a control of nature. If actual conditions differ from those described in this report, our office should be notified. The usage of this report in any independent form cannot be approved unless specific, written verification of the applicability of the recommendations is obtained from our firm. The services provided in this report are only to provide geotechnical characteristics of the subsurface, based on our field data and observations only and also following the ASTM standards. By accepting this report, the client will agree that we are not responsible for reviewing any private investigation that may have been performed at the site or surroundings and not released to public agencies, particularly by the Homeowner Association or leading property management company. We take no responsibility for any matter that is not disclosed to us prior or during our studies. PROFESSIONAL ENGINEERS CONSULTING, Inc. APPENDIX "A" FIGURES & MAPS Class— f7) P.J FlEwnlirl ichwl 000(04 Rd 1775 Je Portela Rd GTal(I p g Fi�d jq Hawk ra*ft'ly Val iart 6<e�wr poll Q 014, 4 1(d 141hk 501 t i h i,mck Im SITE LOCATION A 31775 De Portola Road, Temecula, CA 92592 PROFESSIONAL ENGINEERS CONSULTING, Inc. N Project No.: PM0414 Figure: 1 I o 0 o L r— —r --- — ---------- --------J e 1 I ,: - T 6 T 3 wL od T2A. L . . i o I > O ..,; . ( L T 4 T .'. . .. . .'. .'.'.'. . .'.' . . . . . _.�•r . T r T r.=T =. Try. i :r.. hI A h 7 I <"s' - ' lFL, `.I!r�i 1. I i RLL fs•• .y , :'s -a: lei v -,j ¢• '�dr-�- ��- I �;4j�I.�,y��.-@�. /� ;yy1\ �j�•j - '.- - i,�h .\ .g �♦ '. �,:a.�'r - �'�'. P.A.---i--a— Y'r.r--1-•-1--i-:_�--!^-I"- ' y SITE MAP - SAMPLING LOCATIONS 31775 De Portola Road, Temecula, CA 92592 PROFESSIONAL ENGINEERS CON5ULTING, Inc. Project No.: PM0414 Figure: 2 Figure PS-1 Seismic Hazards C1111 OE TEMECUTA GENERAL PLAN Legend Liquefaction Hazard Zones -^•�•••• Estimated Fault Locations y meTa r Cour"a 1Mum 1 W�elsioe •� Temecula City Boundary Y ����• Sphere of Influence Boundary r r (Manning Area Boundary 31 Sm e.To u,*GIs YM CoaorvSr qg A.,, e — CA \ i r i \ \ \ o a, ♦ �f s i - Y i T « _ CITY OF TEMECULA SEISNIIC HAZARD MAP PROFESSIONAL ENGINEERS CONSULTING, Inc. Project No.: PM0414 Figure: 3 'o�Qvoa - slrE 70 5� p 4 2 5 �r I Qp , � 35 15� �Tta 3 �• �'� QY v a - Q pf MZU so �. sn Qvoa Kgb 50 _ `. 3 ao cps 5 QYC Qis? 5 30Qya 2 40 Qj/C0 T 60 � ' !� �' A 2 Qyc /�0 �q1� Qw,"k-� m T ' . o in GEOLOGIC MAP A 31775 De Portola Road, Temecula, CA 92592 PROFE55IONAL ENGINEERS CONSULTING, Inc. N Project No.: PM0414 Figure: 4 PROFESSIONAL ENGINEERS CONSULTING, Inc. APPENDIX "B" TRENCH LOGS PROFESSIONAL ENGINEERS CONSULTING, Inc. TRENCH LOG Surface Elevation:NA Logged By.SS Trench Orientation:E W Date:04-8-14 T 1 Trench Dimensions:2x I Ox 10 Equipment: Backhoe Groundwater Depth:NA This log is a representation of subsurface conditions at the time&place of excavation. SAMPLE = ENGINEERING Y o o a w CLASSIFICATION AND DESCRIPTION m f— m ii a6 m O F 0—2.5• sm _ Brown sandy silt, loose artificial fill,dry X — 2.5'—C5' ml —5'0 Brown sandy silt,medium dense,damp 4.5'—1 0.0' sm _ Brown sandy silt with some thin layers of clay,dense, moist 10.0 Cemented at 5 feet Heavily cemented at 6.5 feet and below 15.0 c c Loose Soil Ground surface 5.0 Trench profile Native Soil 10.0 15.0 Location& Situation: Surface Gradient:NA 31775 Die Portola Road, Temecula, CA 92592 Scale:- 0./1 nch Project No.: 1„=5.0' PM0414 PROFESSIONAL ENGINEERS CONSULTING, Inc. TRENCH LOG Surface Elevation:NA Logged By.SS Trench Orientation:EW Date:04-8-14 T2 Trench Dimensions:2s10r10 Equipment: Backhce Groundwater Depth:NA This log is a representation of subsurface conditions at the time&place ofescaavtion. SAMPLE F = U ENGINEERING o O o orrs d a CLASSIFICATION AND DESCRIPTION sm 0—3.5' Brown sandy silt,loose artificial fill,some rubbles,dry X _ sm —50 3.5'-5.0' Brown sandy silt,medium dense,damp sm — 5.0'—1 0.0' . _ Brown-sandy silt with some thin layers of clay,dense, moist, 10.0 Cemented _ Heavily cemented at 7.5 feet and below 15.0 It r Loose Soil Ground surface 5.0 Trench profile Native Soil 10.0 15.0 Location & Situation: Surface Gradient:NA 31775 Die Porlola Road, Temewle, CA 92592 Scale:— ft./Inch PrcJmt No.: ,=5.01 PM0414 PROFESSIONAL ENGINEERS CONSULTING, Inc. TRENCH LOG Surface Elevation:NA Logged By:SS Trench Orientation:EW Date:04-8-14 T3 Trench Dimensions:2xl0x10 Equipment: Backhoe Groundwater Depth:NA This log is a representation of subsurface conditions at the time&place of excavation. SAMPLE Lx'p " ENGINEERING Y 3 9 a o a w CLASSIFICATION AND DESCRIPTION o }} F- sm _ 0-1.5' Brown sandy silt,loose to medium dense,dry X sm L5'—2.5' _5.0 Brown sandy silt,medium dense,damp sm - 2.5'-10.0' _ Brown sandy silt with some thin layers of clay,dense, moist 10.0 Cemented .Heavily cemented at 6.0 feet and below 15.0 t t Loose Soil Ground surface 5.0 Trench profile Native Soil 10.0 15.0 Location& Situation: Surface Gradient:NA 31775 De Porro/a Road Temecula, CA 92592 Scale:- fl./l nch PrciKt No 1„=5.0' PM0414 PROFESSIONAL ENGINEERS CONSULTING, Inc. TRENCH LOG Surface Elevation:NA Logged By:SS Trench Orientation:EW Date:04-8-14 T4 Trench Dimensions:2xl0x10 Equipment: Backhce Groundwater Depth:NA This log is a representation of subsurface conditions at the time&olace ofevcavation. SAMPLE F ENGINEERING Y g 9 o 'u a CLASSIFICATION AND DESCRIPTION 0 r yH sm _ 0- 1.5' Brown sandy sill, loose to medium dense,dry X — ml 5.0 1.5'—2.5' Brown sandy silt, medium dense,damp sm — 2.5'—10.0' _ Brown sandy silt with some"thin layers of clay,dense, moist" 10.0 - Cemented _ Heavily cemented at 6.0 feet and below 15.0 i t Loose Soil - Ground surface 5.0 Trench profile Native Soil 10.0 15.0 Location&Situation: Surface Gradient:NA 31775 De Porro/a Road, Temecula, CA 92592 scale:- ft./Inch Pr^iKt No I,,=5.01 PM0414 PROFESSIONAL ENGINEERS CONSULTING, Inc. TRENCH LOG Surface Elevation:NA Logged By. SS _ Trench Orientation:EW Date:04-8-14 TS Trench Dimensions: WWI[) Equipment: Backhoe Groundwater Depth:NA This log is a mpresentation of subsurface conditions at the time&place ofexca%ation. SAMPLE ENGINEERING Y o g r U a CLASSIFICATION AND DESCRIPTION 0 i14 c °�' ml _ 0-2.5' Brown sandy silt, loose to medium dense,dry X — sm 5.0 — 2.5'-10.0' — Brown sandy silt with some thin layers of clay,dense,moist sm — Cemented - 10.0 Heavily cemented at 7.0 feet and below 15.0 c Loose Soil Ground surface 5.0 Trench profile Native Soil 10.0 15.0 Location& Situation: Surface Gradient:NA 37775 De Porto%Road, remeada. CA 92592 scale:— ft./Inch Project No.: I"=5.0' PM0414 PROFESSIONAL ENGINEERS CONSULTING, Inc. TRENCH LOG Surface Elevation:NA Logged By:SS Trench Orientation:EW Date:04.8.14 T6 Trench Dimensions:2x I0x10 Equipment Backhoe Groundwater Depth:NA This log is a representation of subsurface conditions at the time&place of excavation. SAMPLE x ENGINEERING Y 3 9 r o CLASSIFICATION AND DESCRIPTION p p a a m F m LL ai a C O r�- sm _ 0-2.5' Brown sandy silt, loose to medium dense,some rootlets within top X — 12 inches,dry — 5.0 sm — 2.5'—10.0' — Brown sand-silt mix with some thin layers of clay,dense,moist Cemented ml 10.0 Heavily cemented at 7.0 feet and below . . 15.0 i Loose Soil Ground surface 5.0 Trench profile Native Soil 10.0 15.0 Location&Situation: Surface Gradient:NA 31775 Die Porto%Road, rememla, CA 91591 Scale:- ft./Inch Project No.: 1•'=5.0' PM0414 PROFESSIONAL ENGINEERS CONSULTING, Inc. APPENDIX `B" LABORATORY RESULTS AND ANALYSES PROFESSIONAL ENGINEERS CONSULTING Inc. PW T/C/TY TEST 31775 De Portola Road Temecula, CA 92592 ATTERBERG LIMITS Particles passed # 200 sample Liquid Limit Plastic Limit Plasticity Index Tl @ 1.0 to 5.0' 48 36 12 Soil Classification: SILT (ML) ROOM Char! M SO 6 w fW • �\ O 40 - 2 >e �� G\\ 30 20 0. MH « OH Io7 MLcL L 0 0 10 16 20 30 40 SO 60 70 EO 90 100 110 LIQUID LIMIT (LL) PROFESSIONAL ENGINEERS CONSULTING Inc. PLASTIC/TY TEST 31775 De Portola Road Temecula, CA 92592 ATTERBERG LIMITS Particles passed # 200 Sample Liquid Limit Plastic Limit Plasticity Index B2 @ 1.0 to 5.0' 40 35 5 Soil Classification: SILT (ML) 60 Plertici Curl M 30 x mow` y�e o 40 . z 49 U1 A(), .; 20 0. MH on OH 107 ML OL I 00 10 1620 30 40 50 60 70 6o 90 100 110 LIOUIO LIMIT ILL) PROFESSIONAL ENGINEERS CONSULTING Inc. PLASTICITY TEST 31775 De Portola Road Temecula, CA 92592 ATTERBERG LIMITS Particles passed N 200 Sample Liquid Limit Plastic Limit Plasticity Index B4 @ 0.0 to 5.0' 50 35 15 Soil Classification: SILT (ML) 60 P/8d/fCl 00, Cl/er! o50 . 00 0 00 Z 1- 30 r, Q 20 a. �� Goa MH on OH Io 7 — MLoLOL 1 00 10 16 20 w 40 SO w 70 w 90 100 IIO LIQUID LIMIT (LL)_ PROFESSIONAL ENGINEERS CONSULTING Inc. PLASTICITY TEST 31775 De Portola Road Temecula, CA 92592 ATTERBERG LIMITS Particles passed # 200 sample Liquid Limit Plastic Limit Plasticity Index T6 @ 1.0 to 5.0' 35 25 10 Soil Classification: SILT(ML) 80 AWN H SO , O ` Wx 'W O CO 2 r /r 30 / u_ Q 20 a. /; Gva MH w OH 10 - M «+OL I 00 10 16 20 30 40 SO 60 70 60 90 too 110 LIQUID LIMIT (LL) PROFESSIONAL ENGINEERS CONSULTING, Inc. PAR TICL SIZE ANALYSIS PROJECT NUMBER: PM0414 SITE: 31775 De Portola Road, Temecula, CA 92592 SAMPLE: T-I DEPTH: 1.0 -6.6 ft. SIEVE ANALYSIS HYDROMETER ANALYSIS I CLEAR SIEVE I U.S STANDARD SIEVE NUMBERS I OPENINGS r s • 12• f 10 io ao 90 1 100 o 90 i 1 10 �+ 90 �� 1 zc 70 30 00 40 C � Z IN- W 60 , 50 ^< - - — so [.. Z 90 ' 70 z WV U W zo eo W 0. 0. 10 - , 90 0 100 100 10 1.0 0.1 0.01 0.001 PAR'17CLE DIAMETER IN MM CnBBIM mtA%M SAND SHS AND CLAY PAACIION m® Om ®' mEh® flm PROFESSIONAL ENGINEERS CONSULTING, Inc. PARTICL SIZE ANALYSIS PROJECT NUMBER: PM0414 SITE: 31775 De Portola Road, Temecula, CA 92592 SAMPLE: T-2 DEPTH: 1.0 -6.0 ft. ICLEAR SIEVE I U.S.STANDARD SIEVE NUMBERS I oPExwcS. . • r .s • 11r 4 %o 40 4o so 1 fo foo 100 0 00 1 10 I cc 00 40 04 .Z. a s0 �f 1 so W F 04 F F V 30 70 W U W 20 eo W ar o. eo o 100 wo 10 1.0 0.1 0.01 0.001 PAR7ICI.E DIAMETER IN MN mtAVM SAND COWL ES SRT AND CLAY PMC7TON m® 0m m® and 0m q}• 1 u PROFESSIONAL ENGINEERS CONSULTING, Inc. PARTICL SIZE ANALYSIS PROJECT NUMBER: PM0414 SITE: 31775 De Portola Road, Temecula, CA 92592 SAMPLE: T-3 DEPTH: 1.0 -6.0 ft I CLEAR SIEVE I U.S.STANDARD SIEVE NUMBERS OPENINGS 2' .S' 1W 4 10 40 40: 60 1 00 100 0 [� 00 Z - 10 .F 90 20 , 70 _ _ 1 _ _ 90 � 3 p0 SO 40 Q _ _ W Z FG SO , 1 50 40 Q4 60 94 [. x Z 30 70 Z W 20 i 90 04 i 4 10 - 90 p 1 100 100 10 1.0 0.1 0.01 0.001 PARTICLE DIAMETER IN MM mtAV= SAND COBBLES SILT AND CLAY FRACTION m® 0m m --"- Om PROFESSIONAL ENGINEERS CONSULTING, Inc. PARTICL SIZE ANALYSIS PROJECT NUMBER: PM0414 SITE: 31775 De Portola Road, Temecula, CA 92592 SAMPLE: T-4 DEPTH: 1.0 -6.0 ft. CLEAR smw I U.S.STANDARD SIEVE NUMBERS OPENINGS 2' .5' 1/2' q 0q0 30 00 7 0. 00 100 p till ILI 10 IN BO i I 20 30 I. '+ 50 I 40 W 07 —} Z W 50 I 50 -- [s7 40 I � 80 F F U 30 I 70 W U W 20 so W ar I iL 10 — - — B0 0 loo 100 10 1.0 0.1 0.01 0.001 PARTICLE DIAMETER IN MM mIA%*M SAT1D "^^'^"` SILT AND CLAY PRAMON � em a� mom rm