November 15, 2018
ORANGE COUNTY
CuneumcrE Bimm'R
299217.Ln Pn1mn MTGL Project No.: 116SA16
AYem., Parkway C&A, LP MTGL Log No.: 18-3653
Suite A
AIIn6eim.CA 92806 1000 Civic Circle MTGL Branch: Riverside
'lei: 714.612.2999 Lewisville, Texas 75067 Permit No.: B18-3494
Fax: 714.632.2974
Attention: Mr. Sawyer Herndon
S.\N BIEGO
IMPERIAL COl iC1'Y
6295 Feld,Squmr Subject: SOILS COMPACTION REPORT
Snile C
Snll Diego,cn 92121 Raising Cane's 4366— Building Pad
lei: 858.537.3999 40390 Margarita Road
I'az: 838.537.3990
Temecula, Riverside County, California
INIANII I AII'1114:
14467 Meridian Reference: Terracon Consultants, Inc., 2017, "Geotechnical Engineering
llwk •u5 Report, Raising Cane's Restaurant) — Temecula, Northern
Building 2A
Iciva„ilk.CA 9251e Corner of Margarita Road and Verdes Lane, Temecula,
Tel: 951.653.4999 Riverside County, California", Terracon Project No. 60175202,
FRY: 951,653.4666
dated October 18, 2017
OULAANLANu
I.AII'I111:BISPA•C11 1. INTRODUCTION
300.491.2990
SANBILcoffism1'1:11 a. The purpose of this report is to present the results of geotechnical
389.944.5060 observation and testing services provided by MTGL, Inc. during
rough grading of the building pad for proposed Raising Cane's H366
in Temecula, California. The project site is located at
II II11•n11g1in{:CIIII 40390 Margarita Road, in the City of Temecula, Riverside County,
California.
b. This report covers testing services performed from
November 13, 2018 through November 15, 2018.
Page 1 of 8
1 -
Raising Cane's H366 MTG1,Project No. 1165A36
Temecula, Riverside County, California MTGi Los No. 18-3653
2. PROJECT DESCRIPTION
a. The project consisted of preparing the rough graded building pad for a new
approximate 3,935 square foot single-story restaurant building. Estimated
maximum structural loads for the proposed structure are 1 to 2 kips per
linear foot for continuous footings and 40 to 80 kips for isolated pad
footings. The structure is to have a slab-on-grade floor.
b. MTGL, Inc. provided geotechnical observation and testing services during
the current site grading operation for the proposed building pad. Reports
detailing grading operations for project pavement areas and infrastructure
construction operations will be provided under separate cover.
3. GRADING AND EARTHWORK
a. Prior to the performance of site grading, existing improvements,
including an existing restaurant building, pavements, slabs, utility lines,
vegetation, and other debris were removed from the proposed building
site. An 'approximate eight foot (8') deep grease interceptor associated
with the previous on-site restaurant was removed from the southeastern
portion of the proposed building pad. This excavation was backfilled to
the bottom the building pad remedial excavation (see ,below) with
compacted engineered fill.
b. In accordance with the recommendations of the referenced geotechnical
report, the soils beneath the proposed building pad, including a minimum .
distance of at least five beyond the edge of the proposed building, were
over-excavated to a minimum depth of 5 feet below existing ground
elevation. The depth of excavation was sufficient to remove all
undocumented fill within the proposed building pad area and to provide
a minimum of one foot (1') of compacted fill beneath the bottoms of all
foundations.
C. The bottoms of the Initial remedial excavations were observed to be in
competent native materials in accordance with the recommendations of
the referenced geotechnical report. Following review and approval of the
remedial excavations, the soils at the base of the remedial excavations
Page 2 of 8
Raising Cane's#366 MTGL Project No. 1165A16
Temecula. Riverside County.California MTGL Loa No. 18-3653
were then scarified (ripped) a minimum of 10 inches. The scarified soils
were then moisture conditioned and compacted utilizing conventional
grading equipment. Compaction tests performed indicated dry densities
of at least 90 percent of maximum dry density at the test locations.
d. On-site soils used to backfill. the remedial excavations and to bring the
building pad to rough pad grade elevation were placed in in relatively
level thin lifts, approximately 8 inches in thickness. During placement the
soils were moisture-conditioned to near optimum moisture content and
compacted using conventional grading equipment. Compaction tests
performed.on the soils used In the site grading operations indicated dry
densities of at least 90 percent of maximum dry density at the test
locations.
e. Where compaction tests indicated non-conformance with project
requirements, the affected soils were reworked, with the adjustment of
moisture content as required, and recompacted Compaction tests were
then conducted to confirm compaction in accordance with project
requirements.
f. Soils utilized in,the project grading and construction operations consisted
of on-site dark brown, silty sand with.clay (SM/SC soil type based upon
the Unified Soils Classification System)., These sols are similar to the soils
encountered in the referenced �Geotechnical Investigation dated
October 18, 2017.
g. The laboratory maximum density/optimum moisture contents of the soils
utilized in the project grading and construction operations were
determined in accordance with ASTM D 1557 (Method A) test
procedures. Test results are reported in attached Table 1.
c,
Page 3 of 8
Raising Cane's 11366 MTGL Project No. 1165A16
Temecula, Riverside County, California MTG1 Loa No. 18-3653
4. TESTS
4.1 Field Procedures
a. The compacted soils utilized in the project grading and construction
operations were tested by the Soil Technicians as required by the
recommendations of the referenced Geotechnical Report. Results of the
field density testing are presented in attached Table 2.
b. Soils considered representative of those utilized in the project grading
operations were obtained for laboratory testing. Testing consisted of
Maximum Density-Optimum Moisture (ASTM D 1557) for soils.
C. The Expansion Index of soils considered representative of those utilized in
the project grading operations. was determined in accordance with
ASTM D 4829 test procedures. Test results yielded a value of 20, following
into the "Very Low' classification.
4.2 Methods of Tests
Field soil density (compaction) testing was performed by the direct transmission
nuclear method (ASTM D 6938). The maximum density—optimum moisture
relationship of the soils used was established in the laboratory by ASTM D 1557
(Method A)test procedures.
4.3 Records•
A Field Daily Report was prepared by MTG1, Inc.'s Technician for each day of
testing. The reports were generally reviewed by MTG, Inc.'s Engineer, and are
complementary to this report.
Page 4 of 8
Raising Cane's#366 MTGL Project No. 1165A16
Temecula Riverside County, California MTGL Log No. 18-3653
5. CONCLUSIONS
Based on the above described observations and tests, it is considered that the
geotechnical engineering aspects of the building pad grading and construction was
performed in substantial conformance with the approved geotechnical reports and
approved grading plans. The constructed building pad is deemed suitable for the
support of the proposed structure.
6. RECOMMENDATIONS
The.soils encountered during grading are essentially the same materials as those
described in the referenced Geotechnical 'Investigation dated October 18, 2017
prepared by Terracon Consultants, Inc. Project, improvements can be designed and
constructed.in accordance with the soil bearing values and recommended geotechnical
design 'parameters contained within the referenced Geotechnical Investigation and all
applicable. reviews and a Idendums. The building pad soils were tested to have a
"Very Low" Expansion Index (ASTM D 4829) classification. Any additional site grading,
pavement construction or utility installation should.be performed in accordance with
the recommendations of the referenced Geotechnical Investigation dated
October 18, 2017.
7. LIMITATIONS
This report ,contains a statement of professional opinion based on MTGu Inc.'s field
observations during rough grading, the results of tests performed during rough grading,
a review of the referenced geotechnical engineering reports, and a geotechnical
evaluation of the compiled data. MTGL, Inc.'s tests and observations were made in
accordance with commonly accepted procedures consistent with applicable standards
of practice. This report does not constitute a guarantee or warranty of any type and
none should be inferred.
Page 5 of 8
Raising Cane's#366 MTGL Project No. 1165A16
Temecula Riverside County.California MTGy Log No. 18-3653
8. CLOSURE
MTGL, Inc. appreciates this opportunity to be of continued service to you. Should you have any
questions regarding the Information contained herein, please contact us at your earliest
convenience.
Respectfully Submitted,
MTGL, Inc. Qp SPHICIrCi���
y �GEOZE��� �
Bruce A. Hick; P.E., G.E. * STATE
Vice President I Engineering Manager
Attachments: Table 1—Laboratory Compaction Test Results
.Table 2—Field Density Test Results
Page 6 of 8
Raising Cane's#366 MTGt Project No. 1165A16
Temecula Riverside County,California MTGL Log No. 18-3653
TABLE 1
Maximum Density—Optimum Moisture Content*
Lab Material. Max Density Opt Moist
No. Descri tion c
734 Dark Brown Silty Sand with Clay and Trace Gravel (SM/AC) 127.0 11.0
*Test Method: ASTM D1557-Maximum Density Optimum Moisture Relationships
Page 7 of 8
Raising Cane's 4366 MTGL Project No. 1165A16
Temecula-Riverside County.California MTGL Log No. 18-13653
TABLE 2
Field Density Test Results
— Test Elev Moat Dry Rel Req'd
Test ,or Depth. Content Density Max Comp Comp Test
No. Date Location k) (% (pcF) No. m (% ' Type Remarks
1 1 11/14/18 Isoutheast Corner of Pad(Previous Grease Interceptor Backfill) 82.50' 10.71 116.91 734 92 90 1 NU
2 1 11/14/18 ISoutheast Corner of Pad 85.50' 10.41 116.21 734 91 90 NU
3 1 11/14/18 lApproximate Center of Pad 85.S0' 12.01 114.41 734 90 90 NU
4 11/14/18 Northwest Comer of Pad 95.50' 11.9 114.7 734 90 90 NU
S 11/14/18 Northeast Comer of Pad 87.00' 10.0 120.5 734 95 90 NU
6 11/14/18 Southwest Corner of Pad 87.00' 10.9 1233 734 97 90 NU
7 11/15/18 Southeast Corner of Pad 89.0D' 10.5 119.1 734 94 90 NU
8 11/15/18 West-Center of Pad 89.00, 10.9 117.9 734 93 90 NU
9 11/15/18 North-Center of Pad(Pad Grade 89.33' 9.7 117.0 734 92 90 NU
10 11/15/18 Southwest Comer of Pad(Pad Grade) 89.33' 10.6 119.2 734 94 90 NU
NU-Nuclear Gauge Test(ASTM D6938/D2950) SG-Subgrade AB-Aggregate Base Grade
SC-Sand Cone Test(ASTM 1556) FG-Finished Grade AC-Asphalt Concrete
Page 8 of 8