HomeMy WebLinkAboutLot 116-122 Precise Grading GRADING NOTES IAD 1 . ALL GRADING SHALL CONFORM TO THE 1998 CALIFORNIA BUILDING Tract No . 23143 9 CODE, APPENDIX CHAPTER 33, AS AMENDED BY ORDINANCE 99-23. 2. MINIMUM BUILDING PAD AND DRA I NAGE SWALE SLOPE SHALL BE = 1% DRA I NAGECROWN H1 , PROJECT SWALES SHALL BE A MINIMUM OF 0.2' DEEP AND BE CONSTRUCTED A MINIMUM ' OF 2' FROM THE TOP OF CUT OR FILL SLOPES. P"`�'" .. SITE 3. IMAX I MUM CUT OR FILL SLOPES = 2: 1 . � �-r r1 S� GrdingPrecise h 4. PROVIDE 5' WIDE BY 1 ' HIGH BERM OR EQU I VALENT ALONG THE TOP OF ALL ROAD F I LL SLOPES OVER 5 H I GH. ,,,�, 5. ALL GRADING SHALL BE DONE UNDER THE SUPERVISION OF A COMPETENT LEGEND L122ots i SOILS ENGINEER WHO SHALL CERTIFY THAT ALL FILL HAS BEEN PROPERLY TOP OF CURB 0000.00 PLACED AND WHO SHALL SUBMIT A FINAL COMPACTION REPORT FOR ALL FILLS TC �. Q P R 0V E 1 ' DEEP. �lif In City of Temecul St te of Ca FLOW LINE � 7 6. A REGISTERED CIVIL ENGINEER SHALL SUBMIT TO THE CITY OF TEMECULA - -� 22 J ►�►�'` ENGINEERING DEPARTMENT WRITTEN CERTIFICATION OF COMPLETION OF ROUGH HIGH POINT HP ;� ��=:: '� ( 16 19 25 28 I �l " 79 GRADING IN ACCORDANCE WITH THE APPROVED GRADING PLAN PRIOR TO s=-'" .� r `' ,,, 13 ,�' w /1� M SM DIEM ISSUANCE OF THE BUILDING PERMIT. CERTIFICATION SHALL BE TO LINE, F I N I SHED GRADE FG � - �. --- ,,, ', �' GRADE, ELEVATION AND LOCATION OF CUT / FILL SLOPES. Rpy� CRESS _ 23 2a '~ 17 18 F I N I SHED SURFACE FS m 12 , 29 7. PROVIDE BROW DITCH, DESIGNED TO HANDLE 100 YR. Q STORM FLOWS, ALONG # � _ VICINITY MAP TOP OF CUT SLOPES. GRADE BREAK GBS �- NOT TO SCALE 133 � 3'7r�l1V",R't�Z"I - 8. FINAL COMPACTION REPORT WILL BE REQUIRED FOR ALL FILLS GREATER THAN ONE FOOT. GARAGE FLOOR GF 0000.0 TRACT 23143- 10 3 _ 9. ALL GRADING SHALL BE DONE IN CONFORMANCE WITH RECOMMENDATIONS OF PAD ELEVATION PE 0000.0 •, 10 9 8 7 6 5 a 2 I' THE PRELIMINARY SOILS INVESTIGATION BY: RIBA DATED JUNE 4. 2001 , F I N I SI-ED FLOOR FF 0000.0 74 - - !', 8 TWO SETS OF THE FINAL COMPACTION REPORT SHALL BE SUBMITTED TO THE ENGINEERING DEPARTMENT WHICH SHALL INCLUDE FOUNDATION DESIGN RECOM- 73 „ MENDATIONS AND CERTIFICATION THAT GRADING HAS BEEN DONE IN CONFORM- 75 SERVICE - -�W ;J 134 75 ANCE WITH THE RECOMMENDATIONS OF THE PRELIMINARY SOILS REPORT. 72 �- SEWER SERV I CE 10. THE CONTRACTOR SHALL NOTIFY THE CITY OF TEMECULA ENGINEERING 7d71118 1t9 '� 45 DEPARTMENT, TELEPHONE (909) 694-6411 AT LEAST 24 HOURS IN ADVANCE DRIVEWAY 99 �' . REQUESTING FINISH LOT GRADE AND DRAINAGE INSPECTION. THIS INSPEC- 70 77 - 104 TION MUST BE APPROVED PRIOR TO BUILDING PERMIT FINAL INSPECTION FOR I to 98 _�. 117 120 r l 60 EACH LOT. SLOPE 105 61 5 _,....._ ,.._.� 69 I 78 "'' 121 I �I 97 I 116 11 . CUT SLOPES EQUAL TO OR GREATER THAN 5 IN VERTICAL HEIGHT AND FILL LOT NUMBER 12 ,� / SLOPES EQUAL TO OR GREATER THAN 5' IN VERTICAL HEIGHT SHALL 68 I 96 100 101 102 103 106 115 122 /,�� 62 BE PLANTED WITH GRASS OR GROUND COVER TO PROTECT THE SLOPE UNIT TYPE/ELEVATION \2A/ / FROM EROSION AND INSTABILITY IN ACCORDANCE WITH CITY DEVELOPMENT 63 s5 I _ 107 114 / , / 123 �_ HIGH POINT CODE SECTION 17.06 PRIOR TO THE APPROVAL OF F I NAL INSPECTION. INVERT ELEVATION IE 67 95 ` - / 63 5 P 81 / AD ELEV. -0. fr1I N. 12. NO FILL SHALL BE PLACED ON EXISTING GROUND UNTIL THE GROUND HAS �� --- _ 94 I 108 113 /� �� ^ A BEEN CLEARED OF WEEDS, DEBRIS, TOPSOIL, AND OTHER DELETERIOUS BACKWATER VALVES ��,� �AD 82 124 / 64 J f 56 F* MATERIAL. 109 /// /// �/ z ENHANCED BLDG. ELEVAT I ONS 83 93 91 90 89 112 125 / z 13. IF STEEP SLOPING TERRAIN OCCURS UPON WHICH FILL IS TO BE PLACED, THE TERRAIN 59 92 / �/ 65 55 I MUST BE CLEARED KEYED OR FULL SUPPORT. RIGHT SIDE OF LOT ESR AND BENCHED INTO FIRM NATURAL SOIL F fi1 so 111 110 126 I co� ,, � - � / I � 10,_Tr. I PREPARATION SHALL BE APPROVED BY A REGISTERED ENGINEER PRIOR TO PLACEMENT OF LEFT SIDE OF LOT ESL s2 84 •• -_ _ / 5a • FILL MATERIAL. REAR EB f - ----�_ 127 / 66 ( I �' 57 85 • _ - - °� , I 5' B 5' 5- B C 5' C I 14. DURING ROUGH GRADING OPERATIONS AND PRIOR TO CONSTRUCTION OF INDICATES EXTRA V1 45 46 5s \ = 53 I MIN MIN MIN MI PERMANENT DRAINAGE STRUCTURES, TEMPORARY DRAINAGE CONTROL DEPTH FOOTING x a 8620 _ M) N I r - I 67 I I SHOULD BE PROV I DED TO PREVENT PONDING WATER AND DAMAGE TO 44 55 87 24 23 22 21 1 - - _-_ I PAD PAD I ADJACENT PROPERTIES. 25 54 19 52 Z FF z z FF z 15. DUST SHALL BE CONTROLLED BY WATERING2s _- 5 .. OR OTHER METHODS AS APPROVED � � 2 - ��-_ I ' � � BY THE D I RECTOR OF PUBLIC WORKS. 43 27 24 t8 �' ,` I 16 16 I t� 52 3 16. ALL EXISTING DRAINAGE COURSES ON THE PROJECT SITE MUST CONTINUE47 TO FUNCTION, ESPECIALLY DURING STORM CONDITIONS. PROTECTIVE 42 47 51 28 25 23 ,f I ' I z z MEASURES AND TEMPORARY DRA I NAGE PROVISIONS MUST BE USED TO I _ I o O M o I PROTECT ADJOINING PROPERTIES DURING GRADING OPERAT I ONS. 4 t 48 49 22 t 6 I I TRACT 23143 ,ozLN 04 � 15 5- � � �' p j123 I 17. STABILITY CALCULATIONS WITH A FACTOR OF AT LEASE ONE AND FIVE-TENTHS (1 .5) 40 1 30 26 � SHALL BE SUBMITTED BY SOILS ENGINEER TO THE ENGINEERING DEPARTMENT FOR CUT 21 8 al R W AND FILL SLOPES OVER 30' IN VERTICAL HEIGHT. 39 _ _ 1 31 27 14 20 18. A REG I STEREO CIVIL ENGINEER SHALL SUBMIT CERTIFICATION of BUILDING 32 2$ 13 SIDEr TYPICAL YARD DRAINAGE PAD TION (WITHIRESPECTETO MEANIFIC SEA LEVEL) SHALLARE BEREQUIRED, IVEN. IFTHE AN ELEVA- 37 36 35 34 ' 19 12 8 � , ;r1 DISTANCE FROM FRONT PROPERTY CORNER TO THE GARAGE TION WITH RESPECT TO ADJACENT GROUND SURFACE IS REQUIRED THE ACTUAL 33 29 1 f ��- CORNER MEASURED PERPENDICULAR TO THE PROPERTY LINE. DISTANCE ABOVE THE ADJACENT GROUND SHALL BE GIVEN. ' 1s tt 9 ` " a3 19. EROSION CONTROL: ALL GRADED SLOPES SHALL BE PLANTED WITH ROSEA ICE 40' 50' A43 30 32 � � 28 R PLANT AT 12' ON CENTERS OR ANOTHER APPROVED GROUND COVER. SLOPES Ar� 44 6" MIN. 6 MIN.` 17 10 33 ` 29 5' MIN. 5' MIN. 6 MIN. OVER 15 IN VERTICAL HEIGHT, IN ADDITION TO GROUND COVER SHALL BE �AC a5 34 30 27 ' � a7 a6 1 MUDSILL 3 MIN. 1 1 3 MIN. PLANTED WITH APPROVED TREES, SHRUBS, OR COMBINATION THEREOF. SHRUBS 48 41 3 16 35 IN GARAGE AREAS MUDSILL MIN. MIN. I / MUDSILL SHALL BE PLANTED AT 10 ON CENTERS; TREES, 20 ON CENTER; COMB I NAT I ONS, Plan 1 Plan 1 ___ - 32 / 25 2fi „ 15' ON CENTERS. SLOPES OVER 4' IN VERTICAL HEIGHT SHALL HAVE PERMANENT - cv 3-Car \ 40 15 /36 GARAGE FLOOR SILL IS 6 MIN FG FG I RR I GAT I ON SYSTEMS WITH BACKFLOW PREVENTION DEV I CES PER U.P.C. , CHAPTER U-) NC CORETE o, �T_ ?4 - :- . T ABOVE GARAGE - STOOP (TYP.) FLOOR SLAB 20 FINILESSSTHAN 1/4" PERGRADE LFOOT FOR PADM I N I MUMAWAY ROF 3 FEETEXTERIOR WALLS AT NOT SCALE: 1 " - 150 GARAGE DETAIL 12" MIN. 12" MIN. . 21 . NO OBSTRUCTION OF FLOOD PLAINS OR NATURAL WATER COURSES SHALL BE PERMITTED. m r 2X MIN. 6" TYP. 2� MIN. a I LOTS INCLUDED 2: 1 MAX. o ►�s tl�'` 22. ALL PROPERTY CORNERS SHALL BE CLEARLY DELINEATED IN THE FIELD PRIOR j 21 X MAX. MIN. 21% MAX. TO COMMENCEMENT OF ANY CONSTRUCT I ON/GRADING. 501_i37' 4012" MIN. ABOVE PAD ELEV. SECTION INDEX MAP B- B 23. APPROVAL OF THESE PLANS BY THE CITY OR ITS AGENTS DOES NOT RELIEVE ROUND OFF TOP o THE APPLICANT AND HIS ENGINEER FROM THE RESPONSIBILITY FOR THE COR- P/L RECTION OF ERRORS OR OMISSIONS DISCOVERED DURING CONSTRUCTION. UPON REQUEST, THE APPROPRIATE PLAN REV I S I ONS SHALL BE PROMPTLY SUBMITTED Plan 2 Plan 2 w Plan 3 � Plan 4 5' a TO THE CITY ENG I NEER FOR REVIEW AND APPROVAL. �-) 10 3-Car ,n 5' MIN. P/L 00 24. THE ISSUANCE OF THIS PERMIT BY THE CITY OF TEMECULA DOES NOT IMPLY OR � L PAD ELEV 3' MIN. 1 ' PROVIDE ANY CLEARANCES FROM STATE OR FEDERAL WILDLIFE AGENCIES REGULATING PER PLAN MUDSILL MIN. o THE PROVISIONS OF THE CALIFORNIA OR NATIONAL ENDANGERED SPECIES ACTS. 6" MIN. co THE CONTRACTOR/OWNER/DEVELOPER IS RESPONSIBLE FOR OBTAINING THE APPROPRIATEOQ�' CLEARANCES FROM THESE AGENCIES PRIOR TO ANY SITE DISTURBANCES OR GRADING. N SECTION A- A EXTRA DEPTH 7 a �- FOR REAR YARD SLOPES GREATER FOOTING 00 TYPICAL FOOTPRINT PAD ELEV THAN 5 IN VERTICAL HEIGHT PER PLAN =FG-PAD ELEV FL 2: 1 MAX. V) N.T.S. WHERE NECESSARY = 12" MIN. 6" MIN. w UME RG ROUND SERVICE BENCH MARK SOURCE QE TOPOGRAEHY OWNER DEVELOPER IS OF BEARING NOTE2% MIN. O PLANNIND ■ DE®ION ■ CONSTRUCTION ALERT COUNTY OF RIVERSIDE B.M. NO. T-27-81 EL=1230.562 ADJ. DATE 9- 13-82 ANALYTICAL PHOTOGRAIrNMETRIC SURVEYS, INC. KB HOME 21X MAX. 2 1/2 BRASS DISC I N CONC. CYLINDER STAMPED T-27-81 THE BEARINGS FOR THIS SURVEY ARE BASED ON A PORTION SECTION C- C, FROM THE INTERSECTION OF FRONT ST. AND RANCHO CALIF. RD. , 3.4 MILES 647 MAIN STREET, SUITE 1A 12235 EL CAMINO REAL OF THE EASTERLY LINE OF PARCEL MAP NO. 22429 AS SHOWN0 CALL TOLL F� 27;555�z Rona,sum 4aa ' RIVERSIDE,VERS I DE CA 92501 z ■ ■ ■ NORTHEAST ON RANCHO CALIF. RD. 44 NORTHWEST OF RANCHO CALIF. RD. SUITE 100 P.M.B. 147/14-19, RECORDS OF RIVERSIDE COUNTY, CALIFORNIA, a 1-800-422-4133 ���''o'er 9�-�� 13' SOUTH OF A 4' 2 BOARD RAIL FENCE, 2' WEST OF POWER POLE #1751130E. (909) 686--5103 SAN DIEGO, CA. 92130-2647 CONSULTING 0.676.8042 • PAX 9.67&7240 • www.ReF.camBEING N6 7 52 50 W. � SET FIBERGLASS WITNESS POST 1 NORTHWEST OF MONUMENT. DATE FLOWN: SEPTEMBER 30, 1999 (858) 259-6000 0 TWO WORKING DAYS BEFORE YOU DIG ATTN: BOB FALLON LD03-22 9 G R z CONSTRUCT I ON RECORD DATE BY REV I S I ONS DATE ACC'D BENCHMARK � DES I G ED BY DRAWN BY CCEBY SCALE ��� �N Drawing No. o A. JIMENEZ A. JIMENEZ J. TANNER RECOMMENDED BY: DATE. CITY OF T DEPARTMENT OF PUBLIC WORKS Contractor HORIZONTAL Ilk, rr Pians Prepared Under The Supervision Of 1" = 20' w ' No,x0132 ACCEPTED BY: DATE: �� t L -3 T CROWNE HILL o Inspector SEE ABOVE Exp. ����� Date: /o .S D 3 DEPUTY DIRECTOR OF PUBLIC WORKS JOHN D. TANNER, III RONALD J. PARKS - -�=i. TRACT 23143-9 VERTICAL sf C 1 y 1 �� d LOTS 11 -- 122 Date Comp f e�ted �1F OF A`1F�� R.C.E. No. 60132 Expires 6-30-04 R.C.E. No. 19744 Expires 9-30-05 r - a N/A • PREC I SE GRAD I NG PLANS PHASE XV I I I SHEET 1 of 2 106 105 PE=1289.2 PE=1288.9 � / - 1.29aE 4-� 1318. 1295 h �S 13C�?. 1,316 3 �S 2: 1 SLOPE 131`,1 13Q5 • 1 1 "a 1310 8 g1' 131A 1 1 w �5 cr 12.7 47.64 I 0 TS 1312.7 TS 1 44 1312.8 1 1 I 1.0x MIN• f� N 131 ,"1 �0•t r 05~ ~rk 1 1 r1 1311.5 1312.4 N 1•, 1615.3 rL 1313.1 '� 1.0% MIN. 1313.1 I 1315.3 1 1 5' G 311.3 FG FIG F 1311.2 0 ? Q 118 .�P -JD r C-4 1311.7 7.8 w 0 _a 11;t 1311.7 FG 1 v I�5 FF:1316 FG 5' 117 a131g•3 I 116 t� I Q N I C-4 Z �o FF=1313.8 1 ? 131`'•3 115 Ir1312.4PE-1313.1 r: FG 5 3 7' I PE-1310.1N pE:1311.7 - 1 8 i� 1 r ro 171315• 1 2 r� 131 A. I 1311.714.28'14.28' 1314'2 CP .• =1311 .7 7.5 0 1313.0 I 0 FG 5' I 1310.9 1312.fi v' "^ A a, 1 1311.7 M I FG 1312.0 j w 1 5 FG �e GF=1313.1 fE-GB �'st `'� %' �.► I o "" 5 w 1310.7 1311.8 ��► .P 6"FH I (TYP.) GB -_ 1N S r ago (`I B W 12.4 W S 3r Z� �s.3 7 9 0 o FG • 14. 8• �' BW to(n M� �� S ��•�� 09.2 r►� 10.9 li W FGA W S 56.24'7-r GEM dmFfi. ,.. 26 11.43 III0V- �� `- 134 Ci 11 N 1 I OPEN SPACE S ' r' r' 1"AV/AR `1 o WATER" (TYP.) , f AL LA 3�0 3L -IL 4� -1 �7 0 LA r• C r- 1 -� 1-1, coDRE NON OURT 9 - _ 19+ .97 1313.63 3 3" CVP�OUTLET . x� tC MOC 1311.03 IE. W ST.LIGHTSE i (TYP.) .1301.66 RIM�RIM J� \ > > cc 00 �� ELEC.LINE LEC. AD ^� ' • m (TYP. �(TYP. �' ,� `� N N I.r , / co CL 09.2 w S 55.01 J W S 26 20 _ H FG o cp 10.9 18 I r)yep. 0 N P\: w o �I- 43.5 i j o LA IV 04, 1310.5 Al416 Sdop E--f r- 0 1312.2 °� ~l` °D +� `�' o, w S o ,1 � � � 1312.5 '�- "7�' � 13.3 m W N \ m 6' 1311.5 1, 311.9 �_� P FG "� a� cn FG FS N ao = V. • 1313. GF=1313.3 0 ►� �ya I M 25X I FG1313.3 er civ r• .= FG 1314.2 g U� I 00 00101 1314.0 I 1311 1 I 1 INSTALL 65 LF 1313.3 E-GB GF=1315.3 LA- 3 PVC 0 0.57X 1313.2 4 1314.6 1314,8 I oo 1314.3 13 FG FG 1 w 1 Z I G .0 6.4 2 1312.1 TG - FG 1� 1 _ 1311.4 IE 5 GF-1314.3 �� o o PE 1310.3 1314.0 ? ' C; Q o I =� r- • r'o 122 � 121 � � FG �: o •a� 5 1R z 2� ►oe /120\ I _ "o 0 /1-19 F615.2 ` �_ \LAJ FF=1314.0 M z IC14 i oo FF=1312.7 6, �o 0o I 00 1 PE-1312.0 PE 1313.3 FF-1315.0 +t FF=1316.0 E8 ® PE-1314.3 `1 ,� PE-1315.3 E 13133 1311.5 ---"�. 1313.3 o ® a ESL - EB �e t1 I M 7' FG FG o I 1312.0 1312.0 8 6' FG 1312.8U Li 1314.3 1314.3 -j \ I 9' Rik _ 1312.5 50 FG FG 5' �'-' I \ o 1311. o z N 1313.6 H1313.8 0 1315.3 1315.3 I - I z It • "- 1.OX MIN. - • '" I _ r 1.oX MIN. 1313.0 N FG FIG 1314.6 I LJ Li I 1 o z 1314.8 u� C,; * -�.� Ox MIN. ;� LL LO n 1311.7 1 1 I N ' M a �, 3 4.o .- C N TRUC T/ N N TE N �•" I L I Q% rr 3 I l 1315 o Q 3 PVC DRAIN PIPE o 2 6" ROUND AREA DRAIN (NDS 50 OR EQUIVALENT) i i o 00 1313.o ____ - rsQTS 14.3 1315 3 �3 I NSTALL CURB CORE PERIL 1313.0 1314.3 1315.3 I 1316.3 1316.3 CITY OF TEMECULA STD. NO.303 Ts .� rs tS TS / Ts TS T3'i5 00 LU � 2: 1 c•i SLOPE N N 1310 r 1 �ZD• UNDERGROUND SERVICE 2: 1 SLOPE sem' O ALERT PLANNING ■ DE>Ii10N ■ CON>iTRUCTIDN 55.09• ' W OC 55.09' 1305 f i CALL TOLL FREE 27555 YW-Z ROAD,WIFE 400 55.09• 20 0 20 40 60 0 1-800-422-4133 �u�,Com ,925M-4679 j� 128 p i CONSULTING 9UA.678AM ■ FAX9M67&7240 • IwarABF.can �• OPEN SPACE GRAPHIC SCALE TWO woRK I NG DAYS BEFORE YOU DIG - LD03-22 9 G R CONSTRUCT I ON RECORD DATE BY REV I S I ONS DATE ACC'D BENCHMARK ��� S S foN DESIGNED BY DRAWN BY CHECKED BY Drawing No. SCALE ,y "�� A. J I MENEZ A. J I MENEZ J. TANNER RECOMMENDED BY: DATE: /� � CITY OF TEMECULA ANDEPARTMENT OF PUBLIC WORKS a Contractor HORIZONTAL ,�`� ��� F� `yam Plans Prepared Under The Supervision Of ACCEPTED BY: DATE: to zz �3 T CROWNS HILL 0 0 No.60132 Date: .- Inspector SEE SHEET No. 1 1 20 � ExP �/�/� � ?S:!!: - a �s o DEPUTY DIRECTOR OF PUBLIC WORKS � _ - 2 i JOHN D. TANNER, III RONALD J. PARKS �� -- r_iii TRACT 23143 9 VERTICAL sf1 c, l �� LOTS 116 - 122 Q Date Camp I eted fF OF A`lE�� R.C.E. No. 60132 Expires 6-30-04 R.C.E. No. 19744 Expires 9-30-05 f�+mm.. a N/A C PRECISE GRADING PLANS PHASE XVIII SHEET 2 of 2