Loading...
HomeMy WebLinkAboutLD23-1123Permit Number: LD23-1123 LD - Utilities/ Excavation - Parallel Issued: 07/05/2023 Expired: 01/16/2024 Job Address: 42050 Dlr Dr Legal Description: City of Temecula - Land Development Division 41000 Main Street - Temecula, CA 92590 Mailing Address: P.O. Box 9033 Temecula, CA 92589-9033 Phone: (951) 308-6395 Fax: (951) 694-6475 Charter Spectrum (Utility Billing) (951) 547-3816 Applicant: Hhs Construction, Llc 2042 S Grove Avenue Ontario, CA 91761 (909) 393-3322 Contractor: Utility Work Order Number: 3864454 Description: Charter 3864454 WORK HOURS SHALL BE MONDAY – FRIDAY, NO HOLIDAYS, 8:30am - 3:30pm Location: DLR and Ynez Rd Proposed work: Bore to place new 3'' conduit and catv vault as shown on Charter Spectrum plan "CONSTRUCTION DESIGN 42050 DLR DR, LD23-1123" All facilities shall be installed in accordance with City Standard Drawing 117. Traffic Control shall be in accordance with approved Traffic Control Plan LD23-1123 Permittee shall comply with all applicable Traffic Control General Notes. Safe pedestrian/bicycle traffic and driveway access shall be maintained at all times. Concrete repair shall be in accordance with City Standards and the Greenbook. Trench repair shall be in accordance with City Standard Drawing 407. Final compaction test results shall be provided by a soils engineer. Concrete curbs, walks, gutters, cross gutters and driveway approaches damaged during construction shall be removed from joint to joint and reconstructed in accordance with City Standards and the Greenbook. All disturbed landscaping and other improvements shall be removed/repaired and replaced to the satisfaction of Public Works Inspector. Permittee shall contact LDInspections@temeculaca.gov a minimum of two (2) business days prior to any work. Page 1 of 3*****See Page 2 of this Permit for Permittee Responsibilities***** Permit Number: LD23-1123 LD - Utilities/ Excavation - Parallel Permittee must also request a final inspection, via LDInspections@temeculaca.gov, to verify completion of project. Permittee Responsibilities This Permittee agrees to indemnify, defend and save the City, its authorized agents, officers, representatives and employees, harmless from and against any and all penalties, liabilities or loss resulting from claims or court action and arising out of any accident, loss or damage to persons or property happening or occurring as a proximate result of any work undertaken under the permit granted pursuant to this application. Trench repair shall be pursuant to City of Temecula Standard Drawing No. 407. 3.Traffic control devices shall be utilized to protect and control pedestrian and vehicular traffic in the construction area in accordance with the latest revision of the “Manual of Uniform Traffic Control Devices for Streets and Highways” (MUTCD). The contractor shall submit a specific traffic control plan for review and approval by the City in accordance with City “Traffic Control Plan Guidelines” for all work within Major Circulation Element streets. 2.BEFORE YOU DIG - CALL (TOLL FREE) 800-422-4133 A pre-construction meeting is required two (2) business days prior to any scheduled work. Permittee shall contact LDInspections@TemeculaCA.gov to schedule a meeting. 1. 4. Water Quality: Contractor shall remain in compliance with the City Water Pollution Control Ordinance. Contractor is required to provide protection of the City storm drain system. 5. Work hours shall be limited between 7:30 AM and 4:30 PM, Monday through Friday, unless otherwise noted. No work shall be allowed during City-recognized holidays." 6. THIS PERMIT IS ISSUED AND ACCEPTED SUBJECT TO THE FOLLOWING CONDITIONS AND ANY ATTACHED PROVISIONS: All U.S.A. mark outs shall be removed prior to completion of project.7. 8.All contractors and subcontractors shall have a valid City of Temecula business license and valid Certificate of Liability prior to start of work. 9.Should there be any claim against the City and the property owner with the encroachment being the proximate cause, the property owner shall be notified in writing to remove the encroachment within 30 days or the City will remove and bill the owner. 10.Permission is hereby requested to encroach into public right of way to perform work as set forth above. It is understood that this permit is limited to the work described herein and that all work is to be done in compliance with the provisions attached to this permit and with all other applicable rules. Permittee shall be responsible for said compliance, for acceptability of the work, for repair or replacement thereof if defective, and for repair or replacement of any existing improvement damaged by the doing of the work I hereby certify and agree on behalf of the Permittee that all laws, regulations and ordinances of the City of Temecula and the State of California and the terms and conditions of the Permit shall be complied with whether herein stated or not. 11. 12.I hereby warrant and represent to the City that I am authorized to execute this Permit Application on behalf of the Permittee and bind the Permittee to the agreements contained herein and any conditions of the Permit. ******Contractor and all subcontractors shall be present at the pre-construction meeting; otherwise, the meeting will be rescheduled to a later date****** Any work commencing within the City right-of-way before permit issuance or a pre-construction meeting shall be subject to a 72-Hour suspension of said work and an assessment of double permit fees.13. Permitee Date Page 2 of 3 Permit Number: LD23-1123 LD - Utilities/ Excavation - Parallel City Engineer or Authorized Representative Date 07/05/2023 Page 3 of 3 CONSTRUCTION TOTALS (TOTAL AMOUNTS OF ENTIRE ROUTE) PRISM#: 3864454 JOB NOTES: 1.The existence and location of any underground utility pipes or structures was obtained by a search of the available records and field conditions. Additional underground facilities may exist, or the location of the facilities may differ from the locations shown on these plans. The contractor shall, at his own expense, determine the exact location of all such underground facilities prior to commencement of any work or any action which may damage such facilities or interfere with their continuous and proper operation. 2.All plans must be checked and approved by the governmental agency, or agencies, having jurisdiction over the roadways shown on this plan being put into effect. All plans are intended to conform to the Manual on Uniform Traffic Control Devices. The customer/contractor is responsible for ascertaining addition agency requirements for work hours allowed, noise abatement, and other rules and regulations. 3.The temporary traffic controls must be installed per the agency approved plan to be effective. Field changes, other than minor adjustment, must be authorized in writing be a representative of the governmental agency, or agencies, having jurisdiction over the roadway. 4.Plan implementation and device placement should be performed by experienced and trained personnel. 5.Temporary traffic control must be monitored and maintained by the customer/contractor to remain effective. Monitoring and maintenance frequency is dictated by field conditions, but not less than daily. 6.Optimum Inc. has no control over, or responsibility for traffic control plan implementation and inspections performed by others. Users agree to indemnify Optimum Inc. for claims made regarding failure to install, maintain or remove controls per approved traffic control plans. VICINITY MAP PTIMUM, INC. GENERAL ENGINEERING CONTRACTORS OFFICE: (909) 990-0767 CSLB#: 817291 | CLASS: C-7 A C31 17890 VALLEY BLVD BLOOMINGTON CA CONST. COVER SHEET 1 OF 2 7337 CENTRAL AVE RIVERSIDE CA.92504 OFFICE: (833) 267-6097 42050 DIR DR TEMECULA - JESUS SAMANIEGO HHS 09-19-2022 PENDING JUAN HERNANDEZ CITY OF TEMECULA PO#: PRISM#: CHARTER PUBLIC WORKS DEPARTMENT TP TELEPHONE PEDESTAL T TELEPHONE VAULT EV ELECTRIC VAULT CATV VAULT IV IRRIGATION VAULT UTILITY POLE FIRE HYDRANT UNDERGROUND VALVE MAN HOLE F M SL STREET LIGHT VAULT TS TRAFFIC SIGNAL VAULT WV WATER VAULT CATV PEDESTALABOVE GROUND VALVE GV GAS VAULT FO FIBER OPTIC VAULT CV COMMUNICATIONS VAULT ELECTRIC LINEE GAS LINEG TELEPHONE LINET WATER LINEW CATV LINETV TRAFFIC SIGNAL LINETS SEWER LINES STORM DRAIN LINESD FIBER OPTIC LINEFO PETROLUEM LINEP STREET LIGHTSSL INDUSTRIAL WASTEIW OIL LINEO FUEL LINEF RECLAIMED WATERRC T PROPOSED CONSTRUCTION PROPOSED HDD BORE / CONDUIT INSTALLATION PROPOSED TRENCH / CONDUIT INSTALLATION PROPOSED POTHOLE (2'x2') PROPOSED EXIT / MISSILE BORE PIT (2'x4') PROPOSED BORE PIT (3'x6') CATV PROPOSED NEW CATV VAULT (2'x3') UTILITY / LINE LEGENDEXISTING OBJECTS CF EOP EDGE OF PAVEMENT CURB FACE RIGHT OF WAY (CITY) CENTERLINE (C/L) N DESIGN ORIENTATIONREVISIONS REV#DATE DESCRIPTION 36" L E N G T H 24" W I D T H 18 " H E I G H T 3" CONDUIT 36 " T Y P . CO N D U I T D E P T H 18 " D E P T H EXISTING GRADE OR SURFACE OF CONCRETE MOUNT FLUSH WITH GRADE 6" ROCK BASE (3/4" GRAVEL) 36" L E N G T H 18 " W I D T H 20 " H E I G H T CO V E R 18 " H E I G H T BA S E 21 " A B O V E GR A D E COVER 3" CONDUIT 36 " T Y P . CO N D U I T D E P T H EXISTING GRADE OR SURFACE OF CONCRETE 17 " D E P T H BASE 6" ROCK BASE (3/4" GRAVEL) Ø 2. 8 6 4 " Ø 3.164" 0. 3 0 0 " TYPICAL CATV 2'x3' VAULT DETAIL TYPICAL CATV PEDESTAL DETAIL CONDUIT DETAIL 6' 3'2' 4' 3" HDPE MIN. 36" EXIST. GRADESEND BORE PIT RECEIVE BORE PIT 3" CONDUIT FIBER OPTIC CABLE TRACER WIRE 3" HDPE FIBER OPTIC CABLE 3/8" TRACER WIRE 3" CONDUIT 3" CONDUIT TYPICAL DIRECTIONAL BORE DETAIL TRACER WIRE DETAIL INTERDUCT DETAIL EXISTING GRADE HORIZONTAL SCALE: 1" = 40' VERTICAL SCALE: 1" = 4' 36" - 48" COVER C/ L O F S T R E E T 12" CLEARANCE PLACE 1-3" CONDUIT AT 36" - 48" DEPTH EXISTING UTILITIES (NOTE: DEPTH MAY VARY FOR DIFFERENT UTILITIES) TYPICAL UTILITY CLEARANCE (PROTECT IN PLACE AT ALL EX. UTILITY CROSSINGS) N.T.S. WORK DURATION: ·2 DAYS FOR EXCAVATION / BORE / TRENCH WORK ·2 DAY FOR RESTORATION ·1 DAY TO PULL CABLE ·5 DAYS OF TRAFFIC CONTROL SET UP ·TOTAL # OF WORK DAYS: 5 SCOPE OF WORK: ·BORE / TRENCH TO INSTALL CONDUITS FOR CHARTER SPECTRUM (314'). ·SET NEW CHARTER VAULTS (1). ·POTHOLE TO EXPOSE EXISTING UTILITIES (4). ·REMOVE & REPLACE CONCRETE SIDEWALK PANEL (~ 80 sq.ft). S/W D/W PH R/W EX C/L EOP CF ABBREVIATIONS V PED · · · · · · 6" MIN.PIPE O.D.6" MIN. 6" VARIES 42" MIN. COVER OVER PIPE 8" DIA. OR SMALLER SAWCUT T+1 1'-0"1'-0" 5'-0" 12" MAX.12" MAX. 48" MIN COVER OVER PIPE 12" DIA. OR LARGER NOTE: "T" IS THE THICKNESS OF EXISTING A.C. PAVEMENT. CONSTRUCT A.C.(AR4000-C-2) 12" MIN. CLASS 2 AGG BASE MATCH EXISTING. COMPACT TO 95% FINISHED GRADE 0.15 COLDMILL AND OVERLAY WITH AC (AR4000-C-2) SAWCUT BALANCE OF TRENCH TO BE BACKFILLED WITH MATERIALS FROM EXCAVATION FREE OF ROCKS LARGER THAN 6", IN LAYERS NOT EXCEEDING 2' IN DEPTH OR AS SPECIFIED. COMPACT TO 90% APPROVED GRANULAR BACKFILL TO 12" OVER TOP OF PIPE WITH SELECTED GRANULAR MATERIAL WITH A SAN EQUIVALENT OF 30 PER SPECIFICATION. 12" 3' TYPICAL TRENCH RESTORATION ASPHALT BACKFILLED WITH NATIVE SOIL TO 90% COMPACTION PIPE O.D. 36" MIN. COVER FINISHED GRADE 6" 6" MIN. 4' TOTAL TRENCH DEPTH 12" MAX. 6" MIN. 12" MAX. 2"-3" SCH 40 PVC TYPICAL TRENCH RESTORATION DIRT / PARKWAY 4501319683 3864454 STANDARD NO 117: – ➢ ➢ ➢ ➢ ➢ ➢ ➢ ➢ UTILITY PLAN GENERAL NOTES: WORK HOURS SUNDA<  THURSDA< NO HOLIDA<S :00SP  :00DP EXCAVATION AREA 314' CLEARED BY CITY OF TEMECULA PUBLIC WORKS tricia.ortega 05/15/2023 05/15/2023 05/15/2023 05/15/20 ELECTRIC LINEE GAS LINEG TELEPHONE LINET WATER LINEW CATV LINETV TRAFFIC SIGNAL LINETS SEWER LINES STORM DRAIN LINESD FIBER OPTIC LINEFO PETROLUEM LINEP STREET LIGHTSSL INDUSTRIAL WASTEIW OIL LINEO FUEL LINEF RECLAIMED WATERRC PROPOSED CONSTRUCTION PROPOSED HDD BORE / CONDUIT INSTALLATION PROPOSED TRENCH / CONDUIT INSTALLATION PROPOSED POTHOLE (2'x2') PROPOSED EXIT / MISSILE BORE PIT (2'x4') PROPOSED BORE PIT (3'x6') CATV PROPOSED NEW CATV VAULT (2'x3') UTILITY / LINE LEGEND CF EOP EDGE OF PAVEMENT CURB FACE RIGHT OF WAY (CITY) CENTERLINE (C/L) N DESIGN ORIENTATIONREVISIONS REV#DATE DESCRIPTION 00 40'80' #-C #-A #-D _____ IN CONCRETE _____ IN ASPHALT _____ IN DIRT/GREENBELT CALLOUT ABBREVIATIONS TREN (TRENCH TO INSTALL 3" UG CONDUIT) BORE (BORE TO INSTALL 3" UG CONDUIT) BP (BORE PIT 3'x6') MBP (MISSILE BORE PIT 2'x4') PH (POTHOLE 2'x2') V (CATV VAULT) | P (CATV PEDESTAL) R&R (REMOVE & REPLACE) ##' ##- CALLOUT DETAILS XX-X ##' CONSTRUCTION TOTALS (TOTAL AMOUNTS FOR PAGE 2 OF 2) CONSTRUCTION SHEET 2 OF 2 JOB NOTES: 1.The existence and location of any underground utility pipes or structures was obtained by a search of the available records and field conditions. Additional underground facilities may exist, or the location of the facilities may differ from the locations shown on these plans. The contractor shall, at his own expense, determine the exact location of all such underground facilities prior to commencement of any work or any action which may damage such facilities or interfere with their continuous and proper operation. 2.All plans must be checked and approved by the governmental agency, or agencies, having jurisdiction over the roadways shown on this plan being put into effect. All plans are intended to conform to the Manual on Uniform Traffic Control Devices. The customer/contractor is responsible for ascertaining addition agency requirements for work hours allowed, noise abatement, and other rules and regulations. 3.The temporary traffic controls must be installed per the agency approved plan to be effective. Field changes, other than minor adjustment, must be authorized in writing be a representative of the governmental agency, or agencies, having jurisdiction over the roadway. 4.Plan implementation and device placement should be performed by experienced and trained personnel. 5.Temporary traffic control must be monitored and maintained by the customer/contractor to remain effective. Monitoring and maintenance frequency is dictated by field conditions, but not less than daily. 6.Optimum Inc. has no control over, or responsibility for traffic control plan implementation and inspections performed by others. Users agree to indemnify Optimum Inc. for claims made regarding failure to install, maintain or remove controls per approved traffic control plans. TP TELEPHONE PEDESTAL T TELEPHONE VAULT EV ELECTRIC VAULT CATV VAULT IV IRRIGATION VAULT UTILITY POLE FIRE HYDRANT UNDERGROUND VALVE MAN HOLE F M SL STREET LIGHT VAULT TS TRAFFIC SIGNAL VAULT WV WATER VAULT CATV PEDESTALABOVE GROUND VALVE GV GAS VAULT FO FIBER OPTIC VAULT CV COMMUNICATIONS VAULT T EXISTING OBJECTS S/W D/W PH R/W EX C/L EOP CF ABBREVIATIONS V PED · · · · · · 56' CF CF CF CF CF CF CF CF CF EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP CF CF CF CF CF CF CF CF CF EOP EOP EOP EOP EOP EOP EOP EOP EOP C F C F C F C F C F E O P E O P CF EOP EO P E O P C F E O P E O P E O P E O P E O P E O P E O P E O P 110' 78' 11' 11' 134' 12' 12' Y N E Z R D DIR D R V V E E E E E E E W W W W W W W W W E SCE T T T T T T T T SL E E E F 3'x6' BP-D 3'x6' BP-C 3'x6' BP-C 2'x2' PH-D 2'x3' V2-D- 30 sq.ft R&R-C 30 sq.ft R&R-C EX.CATV VAULT1 | 3" 10' BORE 1 | 3" 250' BORE 1 | 3" 40' BORE 1 | 3" 14' BORE W W W 2'x2' PH-D 2'x2' PH-C 20 sq.ft R&R-C 10 sq.ft R&R-C 1+0 0 0 + 0 0 2+00 3+00 4+00 1 + 0 0 1 + 0 0 PRISM#: 3864454 PTIMUM, INC. GENERAL ENGINEERING CONTRACTORS OFFICE: (909) 990-0767 CSLB#: 817291 | CLASS: C-7 A C31 17890 VALLEY BLVD BLOOMINGTON CA 7337 CENTRAL AVE RIVERSIDE CA.92504 OFFICE: (833) 267-6097 42050 DIR DR TEMECULA - JESUS SAMANIEGO HHS 09-19-2022 PENDING JUAN HERNANDEZ CITY OF TEMECULA PO#: PRISM#: CHARTER PUBLIC WORKS DEPARTMENT 4501319683 3864454 GRE E N B E L T SIDEW A L K SIDEW A L K SIDE W A L K GREE N B E L T GREE N B E L T SIDEW A L K SIDE W A L K G R E E N B E L T S I D E W A L K S I D E W A L K WORK HOURS SU1'$<  7HURS'$< 1O HO/,'$<S SP  DP VICINITY MAP EXCAVATION AREA 314' BEHIND SIDEWALK LD23-1123 CLEARED BY CITY OF TEMECULA PUBLIC WORKS tricia.ortega 03/13/2023 03/13/2023 03/13/2023 03/13/20 N DESIGN ORIENTATION PRISM#: 3864454 42050 DIR DR TEMECULA - JESUS SAMANIEGO HHS 03-29-2023 PENDING JUAN HERNANDEZ CITY OF TEMECULA PO#: PRISM#: PUBLIC WORKS DEPARTMENT 4501319683 3864454 EXCAVATION AREA 314' PUBLIC WORKS - TRAFFIC ENGINEERING DIVISION CITY OF TEMECULAENGINEER'S INFORMATIONENGINEER'S SEAL FOR TRAFFIC CONTROL PLANS MAZDA OF TEMECULA CABLE INSTALLATION DIR DR CONTRACTOR: RECOMMENDED BY:DATE: ACCEPTED BY:DATE: R.T.E. NO. NICOLAS M. MINICILLI TRAFFIC ENGINEER USGaWHG TUaIILF CRQWURl NRWHV WR UHY -AJP AJP 12612 TRAFFIC CONTROL GENERAL NOTES (REV'D. 08/26/20): 1.ALL TRAFFIC CONTROL DEVICES SHALL CONFORM TO THE LATEST EDITION OF THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (CALIFORNIA MUTCD) AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION. 2.THE CITY ENGINEER OR HIS REPRESENTATIVE HAS THE AUTHORITY TO INITIATE FIELD CHANGES TO ASSURE PUBLIC SAFETY. 3.ALL TRAFFIC CONTROL DEVICES SHALL BE REMOVED FROM VIEW WHEN NOT IN USE. 4.WORK HOURS SHALL BE RESTRICTED TO THE PERIOD BETWEEN 8:30 A.M. AND 3:30 P.M., MONDAY THROUGH FRIDAY, UNLESS APPROVED OTHERWISE. WHEN NIGHT WORK IS REQUIRED, WORK HOURS SHALL BE 9 P.M. TO 5 A.M., SUNDAY THROUGH THURSDAY. 5.TRENCHES MUST BE BACK FILLED OR PLATED DURING NON-WORKING HOURS. STEEL PLATES SHALL HAVE ASPHALTIC CONCRETE BERM ON ALL EDGES. ALL DIRT, DUST, AND DEBRIS SHALL BE REMOVED FROM STREET AT END OF EACH DAY AND AT THE END OF THE JOB. THE STREET SHALL BE IN DRIVABLE CONDITION AT ALL TIMES. 6.PEDESTRIAN CONTROLS SHALL BE PROVIDED AS SHOWN ON THE PLANS. 7.TEMPORARY "NO PARKING" SIGNS WILL BE POSTED 24 HOURS PRIOR TO COMMENCING WORK. 8.ACCESS TO DRIVEWAYS WILL BE MAINTAINED AT ALL TIMES UNLESS OTHER ARRANGEMENTS ARE MADE. 9.THE CONTRACTOR SHALL REPLACE WITHIN 72 HOURS, ALL TRAFFIC SIGNAL LOOP DETECTORS DAMAGED DURING CONSTRUCTION. 10.THE CONTRACTOR SHALL REPLACE WITHIN 24 HOURS, ALL STRIPING REMOVED OR DAMAGED BY CONSTRUCTION WORK. (STRIPING MAY BE REPLACED TEMPORARILY WITH TAPE.) 11.ALL WORKERS SHALL BE EQUIPPED WITH AN ORANGE VEST (OR A REFLECTIVE VEST AT NIGHT). ALL FLAGGERS SHALL ALSO BE EQUIPPED WITH A HARD HAT, C28 "STOP/SLOW" PADDLE AND SHALL BE TRAINED IN THE PROPER FUNDAMENTALS OF FLAGGING TRAFFIC. 12.ANY WORK THAT DISTURBS NORMAL TRAFFIC SIGNAL OPERATIONS SHALL BE COORDINATED WITH THE CITY OF TEMECULA'S TRAFFIC DIVISION, 48 HOURS PRIOR TO BEGINNING CONSTRUCTION. CONTACT THE CITY'S TRAFFIC DIVISION AT (951) 694 -6411. 13.THE CONTRACTOR SHALL MAINTAIN ALL TRAFFIC CONTROL DEVICES 24 HOURS PER DAY AND 7 DAYS PER WEEK. 14.A MINIMUM OF TWELVE (12) FOOT TRAVEL LANES MUST BE MAINTAINED UNLESS OTHERWISE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS. 15.ALL NIGHT WORK WILL REQUIRE WRITTEN APPROVAL FROM THE DEPARTMENT OF PUBLIC WORKS. LANE CLOSURES, ROAD DETOURS, ROAD CLOSURES, AND TRAFFIC SIGNAL MODIFICATIONS ASSOCIATED WITH OVERNIGHT CONSTRUCTION ACTIVITIES WILL REQUIRE WARNING SIGNS BE PLACED AT LEAST ONE WEEK IN ADVANCE OF STARTING CONSTRUCTION. 16.A SOLAR POWERED FLASHING ARROW BOARD SHALL BE REQUIRED ON ALL ARTERIAL STREET LANE CLOSURES. 17. IF THE PERMIT APPLICANT DETERMINES THAT CONDUIT INSTALLATION WILL BE BY THE BORING MACHINE METHOD, THE TRENCH PATCH FOR THE UTILITY OBSERVATION EXCAVATION WILL BE THE SAME AS FOR OPEN TRENCH EXCAVATION METHOD. THIS WILL PROVIDE A SINGLE CONTINUOUS SURFACE RESTORATION ELIMINATING THE MULTIPLE PENETRATION INTO THE PUBLIC ROADWAY TO ALL REQUIREMENTS IN CITY STANDARD DRAWING # 407 (SHEET 1 AND 2) FOR TRENCH PATCH. 18. ANY WORK THAT CREATES AN UNDUE SAFETY RISK OR CREATES SEVERE CONGESTION MAY BE SHUT DOWN BY CITY TRAFFIC ENGINEERS, CITY FIELD INSPECTION, OR THE POLICE DEPARTMENT. 19. CONES AND DELINEATORS SHALL HAVE REFLECTORIZED SLEEVES FOR NIGHT WORK. 20. IF PARKING IS ALLOWED IN ADVANCE WARNING AREA, ADVANCE WARNING SIGNS SHALL BE MOUNTED ON HIGH LEVEL DEVICES. APPLICANT IS RESPONSIBLE FOR FULL AND COMPLETE REPRESENTATION OF THE ACTUAL ROAD CONDITIONS SHOWN ON THIS PLAN INCLUDING, BUT NOT LIMITED TO EXISTING STRIPING, SIGNING, SIDEWALKS, AND BIKE LANES. 7337 CENTRAL AVE RIVERSIDE CA.92504 OFFICE: (833) 267-6097 CHARTER PTIMUM, INC. GENERAL ENGINEERING CONTRACTORS OFFICE: (909) 990-0767 CSLB#: 817291 | CLASS: C-7 A C31 17890 VALLEY BLVD BLOOMINGTON CA 1 3 HHS OFFICE: (909) 721-3785 CSLB#: 818906 | CLASS: A C31 C10 B C-7 2042 S. GROVE AVE, ONTARIO CA 91761 UTILITY COMPANY: PROPOSED SIGNS: TCP-1 NO TURN ON RED R10-11 AHEAD W20-5 CLOSED RIGHT OR CENTER OR C20B(CA) NO. OF LANES LEFT LANE INTERCHANGEABLE WITH C20(CA) W4-2R RIGHT LANE MUST TURN RIGHT END ROAD WORK G20-2 ROAD AHEAD W20-1 WORK LANE CLOSED C30(CA) R3-7 4 1 1 1 1 1 1 W11-1 SHARE THE ROAD W16-1 1 1 BIKE 1 PROPOSED SIGNS: TCP-2 ROAD AHEAD W20-1 WORK 4 SHOULDER CLOSED C30A(CA) 2 END ROAD WORK G20-2 4 EXISTING NO TURN LANE TRAFFIC CONE FLASHING ARROW SIGN (FAS) EXISTING TURN ONLY LANE BARRICADE WORK ZONE TRAFFIC SIGNAL HIGH LEVEL WARNING DEVICE (WITH CALTRANS MUTCD CODE) SIGN (WITH CALTRANS CODE) TRAFFIC FLOW DIRECTION FLAGGER S DETAIL SHEET LEGEND CONE SPACING - 25' MAXIMUM AT LEAST TWO DAYS UG SERVICE ALERT OF SOUTHERN CALIFORNIA BEFORE YOU DIG DIGALERT Call: TOLL FREE 1-800-227-2600 FLASHING ARROW SIGN TRAILER (TYP.) (FAS) MISCELLANEOUS DEVICES WORK HOURS SU1'$<  7HURS'$< 1O HO/,'$<S SP  DP AREA MAP: 2647 NARROW ROAD W5-1 NARROW LANE C12(CA) W11-1 SHARE THE ROAD W16-1 1 1 BIKE LANE CLOSED C30(BIKE) 1 R3-4 2 6/16/2023 awa7537 6/21/23 06/21/23 N DESIGN ORIENTATION PROPOSED TCP PRISM#: 3864454 42050 DIR DR TEMECULA - JESUS SAMANIEGO HHS 03-29-2023 PENDING JUAN HERNANDEZ CITY OF TEMECULA PO#: PRISM#: PUBLIC WORKS DEPARTMENT 4501319683 3864454 PROPOSED SIGNS NO TURN ON RED R10-11 AHEAD W20-5 CLOSED RIGHT OR CENTER OR C20B(CA) NO. OF LANES LEFT LANE INTERCHANGEABLE WITH C20(CA) W4-2R RIGHT LANE MUST TURN RIGHT END ROAD WORK G20-2 ROAD AHEAD W20-1 WORK LANE CLOSED C30(CA) R3-7 1 1 0 1 1 1 1 W11-1 SHARE THE ROAD W16-1P 1 1 1 PUBLIC WORKS - TRAFFIC ENGINEERING DIVISION CITY OF TEMECULAENGINEER'S INFORMATIONENGINEER'S SEAL FOR TRAFFIC CONTROL PLANS MAZDA OF TEMECULA CABLE INSTALLATION DIR DR CONTRACTOR: RECOMMENDED BY:DATE: ACCEPTED BY:DATE: R.T.E. NO. NICOLAS M. MINICILLI TRAFFIC ENGINEER USGaWHG TUaIILF CRQWURl NRWHV WR UHY -AJP AJP 1/26/12 7337 CENTRAL AVE RIVERSIDE CA.92504 OFFICE: (833) 267-6097 CHARTER PTIMUM, INC. GENERAL ENGINEERING CONTRACTORS OFFICE: (909) 990-0767 CSLB#: 817291 | CLASS: C-7 A C31 17890 VALLEY BLVD BLOOMINGTON CA 2 3 HHS OFFICE: (909) 721-3785 CSLB#: 818906 | CLASS: A C31 C10 B C-7 2042 S. GROVE AVE, ONTARIO CA 91761 UTILITY COMPANY: 350' SIGN SPACING 350' SIGN SPACING 350' SIGN SPACING 100' MIN. GAP 100' TURN POCKET 30' WORK AREA 540' MERGING TAPER C U R B O R E . P . C U R B O R E . P . DOWN STREAM 50' MIN./ 100'. MAX 350' SIGN SPACING 110' 55' 55' 22' 10' Y N E Z R D 4 5 M P H Y N E Z R D 4 5 M P H N.T.S. AT LEAST TWO DAYS UG SERVICE ALERT OF SOUTHERN CALIFORNIA BEFORE YOU DIG DIGALERT Call: TOLL FREE 1-800-227-2600 AREA MAP: EXCAVATION AREA 20' E N D R O A D W O R K G 2 0 - 2 R O A D A H E A D W 2 0 - 1 W O R K END ROA D W O R K G20- 2 R O A D A H E A D W 2 0 - 1 W O R K E N D R O A D W O R K G 2 0 - 2 R O A D A H E A D W 2 0 - 1 W O R K S H A R E T H E R O A D W 1 6 - 1 P W 4 - 2 R W 1 1 - 1 R I G H T L A N E M U S T T U R N R I G H T R 3 - 7 E N D R O A D W O R K G 2 0 - 2 R O A D A H E A D W 2 0 - 1 W O R K WORK HOURS SU1D$<  THURSD$< 1O HO/,D$<S SP  DP 2647 350' SIGN SPACING 180' BIKE TAPER A H E A D C L O S E D L A N E A H E A D C L O S E D L A N E 1 B I K E C 2 0 ( B I K E ) 350' SIGN SPACING BIKE LANE CLOSED C30(BIKE) 1 B I K E L A N E C L O S E D C 3 0 ( B I K E ) A H E A D C L O S E D L A N E 1 A H E A D C L O S E D L A N E 1 R I G H T C 2 0 ( R T ) BIKE R3-4 2 R 3 - 4 R 3 - 4 6/16/2023 awa7557 6/21/23 06/21/23 N DESIGN ORIENTATION PROPOSED TCP PRISM#: 3864454 42050 DIR DR TEMECULA - JESUS SAMANIEGO HHS 03-29-2023 PENDING JUAN HERNANDEZ CITY OF TEMECULA PO#: PRISM#: PUBLIC WORKS DEPARTMENT 4501319683 3864454 PUBLIC WORKS - TRAFFIC ENGINEERING DIVISION CITY OF TEMECULAENGINEER'S INFORMATIONENGINEER'S SEAL FOR TRAFFIC CONTROL PLANS MAZDA OF TEMECULA CABLE INSTALLATION DIR DR CONTRACTOR: RECOMMENDED BY:DATE: ACCEPTED BY:DATE: R.T.E. NO. NICOLAS M. MINICILLI TRAFFIC ENGINEER USGaWHG TUaIILF CRQWURl NRWHV WR UHY -AJP AJP 1/26/12 7337 CENTRAL AVE RIVERSIDE CA.92504 OFFICE: (833) 267-6097 CHARTER PTIMUM, INC. GENERAL ENGINEERING CONTRACTORS OFFICE: (909) 990-0767 CSLB#: 817291 | CLASS: C-7 A C31 17890 VALLEY BLVD BLOOMINGTON CA 3 3 HHS OFFICE: (909) 721-3785 CSLB#: 818906 | CLASS: A C31 C10 B C-7 2042 S. GROVE AVE, ONTARIO CA 91761 UTILITY COMPANY: EXCAVATION AREA 294' N.T.S. PROPOSED SIGNS ROAD AHEAD W20-1 WORK END ROAD WORK G20-2 SHOULDER CLOSED C30A(CA) 4 2 4 110' 55' 55' Y N E Z R D 4 5 M P H Y N E Z R D 4 5 M P H 22' 12' 22' 10'DOWN STREAM TAPER 50' MIN./ 100' MAX 250' WORK AREA 200' BUFFER 60' SHOULDER TAPER 250' SIGN SPACING 12' SHOULDER C30A(CA) CLOSED E N D R O A D W O R K G 2 0 - 2 E N D R O A D W O R K G 2 0 - 2 END ROA D W O R K G20- 2 END ROAD WORK G20-2 ROAD AHEAD W20-1 WORK R O A D A H E A D W 2 0 - 1 W O R K R O A D A H E A D W 2 0 - 1 W O R K R O A D A H E A D W 2 0 - 1 W O R K AT LEAST TWO DAYS UG SERVICE ALERT OF SOUTHERN CALIFORNIA BEFORE YOU DIG DIGALERT Call: TOLL FREE 1-800-227-2600 AREA MAP: WORK HOURS SU1D$<  THURSD$< 1O HO/,D$<S SP  DP 50' MIN. 250' SIGN SPACING 250' SIGN SPACING NARROW LANE C12(CA) NARROW ROAD W5-1 NARROW C12(CA) LANE W5-1 NARROW ROAD W11-1 SHARE THE ROAD W16-1P 1 1 SHARE THE ROAD W16-1P W11-1 26476/16/2023 awa7537 6/21/23 06/21/23