Loading...
HomeMy WebLinkAboutLD23-1497Permit Number: LD23-1497 LD - Utilities/ Excavation - Parallel Issued: 07/28/2023 Expired: 01/24/2024 Job Address: 32105 De Portola Rd Legal Description: City of Temecula - Land Development Division 41000 Main Street - Temecula, CA 92590 Mailing Address: P.O. Box 9033 Temecula, CA 92589-9033 Phone: (951) 308-6395 Fax: (951) 694-6475 Michelle Guerra 325 W. Hospitality Lane Suite 206 Suite 206, Suite 206 San Bernardino, CA 92408 Applicant: Contractor: Utility Work Order Number: Description: Crown Castle; HBLTCX46 WORK HOURS SHALL BE SUNDAY - THURSDAY: 9PM - 5AM Location: 32105 De Portola Crown Castle to place 25' of (1)- 2" duct, Place 44' of (2)- 1 1/4" duct, (1)- 2" duct and (1)- 1 1/2" 7 way future path 7 way microduct approx. 69' along De Portola Rd. All facilities shall be installed in accordance with City Standard Drawing 117. Traffic Control shall be in accordance with approved Traffic Control Plan LD23-1497 Permittee shall comply with all applicable Traffic Control General Notes. Safe pedestrian/bicycle traffic and driveway access shall be maintained at all times. Concrete repair shall be in accordance with City Standards and the Greenbook. Trench repair shall be in accordance with City Standard Drawing 407. Final compaction test results shall be provided by a soils engineer. Concrete curbs, walks, gutters, cross gutters, and driveway approaches damaged during construction shall be removed from joint to joint and reconstructed in accordance with City Standards and the Greenbook. All disturbed landscaping and other improvements shall be removed or repaired and replaced to the satisfaction of Public Works Inspector. Permittee shall contact LDInspections@temeculaca.gov a minimum of two (2) business days prior to any work. Permittee must also request a final inspection, via LDInspections@temeculaca.gov, to verify completion of project. Page 1 of 2*****See Page 2 of this Permit for Permittee Responsibilities***** Permit Number: LD23-1497 LD - Utilities/ Excavation - Parallel Permittee Responsibilities This Permittee agrees to indemnify, defend and save the City, its authorized agents, officers, representatives and employees, harmless from and against any and all penalties, liabilities or loss resulting from claims or court action and arising out of any accident, loss or damage to persons or property happening or occurring as a proximate result of any work undertaken under the permit granted pursuant to this application. Trench repair shall be pursuant to City of Temecula Standard Drawing No. 407. 3.Traffic control devices shall be utilized to protect and control pedestrian and vehicular traffic in the construction area in accordance with the latest revision of the “Manual of Uniform Traffic Control Devices for Streets and Highways” (MUTCD). The contractor shall submit a specific traffic control plan for review and approval by the City in accordance with City “Traffic Control Plan Guidelines” for all work within Major Circulation Element streets. 2.BEFORE YOU DIG - CALL (TOLL FREE) 800-422-4133 A pre-construction meeting is required two (2) business days prior to any scheduled work. Permittee shall contact LDInspections@TemeculaCA.gov to schedule a meeting. 1. 4. Water Quality: Contractor shall remain in compliance with the City Water Pollution Control Ordinance. Contractor is required to provide protection of the City storm drain system. 5. Work hours shall be limited between 7:30 AM and 4:30 PM, Monday through Friday, unless otherwise noted. No work shall be allowed during City-recognized holidays." 6. THIS PERMIT IS ISSUED AND ACCEPTED SUBJECT TO THE FOLLOWING CONDITIONS AND ANY ATTACHED PROVISIONS: All U.S.A. mark outs shall be removed prior to completion of project.7. 8.All contractors and subcontractors shall have a valid City of Temecula business license and valid Certificate of Liability prior to start of work. 9.Should there be any claim against the City and the property owner with the encroachment being the proximate cause, the property owner shall be notified in writing to remove the encroachment within 30 days or the City will remove and bill the owner. 10.Permission is hereby requested to encroach into public right of way to perform work as set forth above. It is understood that this permit is limited to the work described herein and that all work is to be done in compliance with the provisions attached to this permit and with all other applicable rules. Permittee shall be responsible for said compliance, for acceptability of the work, for repair or replacement thereof if defective, and for repair or replacement of any existing improvement damaged by the doing of the work I hereby certify and agree on behalf of the Permittee that all laws, regulations and ordinances of the City of Temecula and the State of California and the terms and conditions of the Permit shall be complied with whether herein stated or not. 11. 12.I hereby warrant and represent to the City that I am authorized to execute this Permit Application on behalf of the Permittee and bind the Permittee to the agreements contained herein and any conditions of the Permit. ******Contractor and all subcontractors shall be present at the pre-construction meeting; otherwise, the meeting will be rescheduled to a later date****** Any work commencing within the City right-of-way before permit issuance or a pre-construction meeting shall be subject to a 72-Hour suspension of said work and an assessment of double permit fees.13. Permitee Date City Engineer or Authorized Representative Date 07/28/2023 Page 2 of 2 0"40' 40'20' 24"x36" SCALE: 1" = 40'-0" FLASHING ARROW BOARD DELINEATOR CONE WITH SIGN TEMPORARY SIGN WORK VEHICLE DIRECTION OF TRAVEL TYPE II BARRICADE TYPE III BARRICADE TYPE III BARRICADE WITH SIGN WORK AREA LEGEND: HIGH-LEVEL WARNING DEVICE SIGNALIZED INTERSECTIONS TYPE II BARRICADE WITH SIGN DIRECTIONAL BORE MACHINE STEEL PLATES NE N E SE SW W NW S W SE NW WORK HOURS: APPROX. DURATION OF WORK: TYPE OF WORK: NOTE: INSTALL TEMPORARY TANSAT 72 HOURS PRIOR TO WORK IF NEEDED 9:00 PM TO 5:00 AM SUNDAY - THURSDAY 3 DAYS TRENCH AND PLACE NOTES W20-1 ROAD WORK AHEAD (BIKE) BIKE LANE CLOSED AHEAD W20-5 W11-1 W16-1 SHARE THE ROAD W20-5R CLOSEDLANE AHEAD RIGHT W4-2R RAISED M E D I A N C30-BIKE BIKE LANE CLOSED DE P O R T O L A R O A D (45 M P H ) 180'BIKE L A N E T A P E R 350' 350' 350' 175' C30-BIKE BIKE LANE CLOSED DRIVE W A Y G20-2 END ROAD WORK BIKE L A N E BIKE L A N E BIKE L A N E 12 ' STO P STO P STO P DE PORT O L A R O A D (45 MPH) CAMPANULA WAY (30 MPH) VIA TAMARITE (25 MPH) HH 30' BUFFER G20-2 END ROAD WORK CURB 540' MERGING T A P E R RAISED M E D I A N RAISED M E D I A N RAISED M E D I A N C30-BIKE BIKE LANE CLOSED C30-BIKE BIKE LANE CLOSED C30 (CA) LANE CLOSED 25 0 ' W20-1 ROAD WORK AHEAD 10 0 ' W20-1 ROAD WORK AHEAD 350' CURB G20-2 END ROAD WORK G20-2 END ROAD WORK RA I S E D M E D I A N 4 ' SIDEW A L K PROVIDE FLAGGER TO MAINTAIN PEDESTRIAN ACCESS (PRIVAT E D R I V E W A Y ) BIKE LANE BIKE LAN E BIKE LANE BIKE LANE BIKE LAN E BIKE LAN E 1 2 ' 1 2 ' 12 ' BIKE LANE BIKE LAN E 12 ' CUR B CUR B R3-4 R3-4 TRAFFIC CONTROL PLAN GENERAL NOTES 1. ALL TRAFFIC CONTROL DEVICES SHALL CONFORM THE LATEST EDITION OF THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (2019 CALIFORNIA MUTCD) AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION. 2. THE CITY TRAFFIC ENGINEER OR HIS REPRESENTATIVE HAS THE AUTHORITY TO INITIATE FIELD CHANGES TO ASSURE PUBLIC SAFETY. 3. ALL TRAFFIC CONTROL DEVICES SHALL BE REMOVED FROM VIEW WHEN NOT IN USE. 4. WORK HOURS SHALL BE RESTRICTED TO THE PERIOD BETWEEN 9:00 A.M. TO 3:30 P.M., MONDAY TO FRIDAY AND 8:00 A.M. TO 6:00 P.M., SATURDAY UNLESS APPROVED OTHERWISE. WORK IS NOT PERMITTED ON CITY HOLIDAYS. 5. TRENCHES MUST BE BACK FILLED OR PLATED DURING NON-WORKING HOURS. 6. PEDESTRIAN CONTROLS SHALL BE PROVIDED AS SHOWN ON THE PLANS. 7. TEMPORARY "T.A.N.S.A.T." SIGNS SHALL BE POSTED BY THE CONTRACTOR 72 HOURS PRIOR TO COMMENCING WORK. 8. ACCESS TO DRIVEWAYS WILL BE MAINTAINED AT ALL TIMES UNLESS OTHER ARRANGEMENTS ARE MADE. 9. THE CONTRACTOR SHALL REPLACE WITHIN 72 HOURS ALL TRAFFIC SIGNAL LOOP DETECTORS DAMAGED DURING CONSTRUCTION. 10. THE CONTRACTOR SHALL REPLACE WITHIN 24 HOURS, ALL STRIPING, REMOVED OR DAMAGED BY CONSTRUCTION WORK. (STRIPING MAY BE REPLACED TEMPORARILY WITH TAPE.) 11. ALL WORKERS SHALL BE EQUIPPED WITH AN ORANGE VEST (OR A REFLECTIVE VEST AT NIGHT). ALL FLAGGERS SHALL ALSO BE EQUIPPED WITH A HARD HAT, C28 "STOP/SLOW" PADDLE AND SHALL BE TRAINED IN THE PROPER FUNDAMENTALS OF FLAGGING TRAFFIC. 12. ANY WORK THAT DISTURBS NORMAL TRAFFIC SIGNAL OPERATIONS SHALL BE COORDINATED WITH THE CITY OF TEMECULA 48 HOURS PRIOR TO BEGINNING CONSTRUCTION. 13. THE CONTRACTOR SHALL MAINTAIN ALL TRAFFIC CONTROL DEVICES 24 HOUR PER DAY AND 7 DAYS PER WEEK. 14. A MINIMUM OF TWELVE (12) FOOT TRAVEL LANES MUST BE MAINTAINED UNLESS OTHERWISE APPROVED BY THE CITY OF TEMECULA. 15. ALL NIGHT WORK WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF TEMECULA. LANE CLOSURES, ROAD DETOURS, ROAD CLOSURES, AND TRAFFIC SIGNAL MODIFICATIONS ASSOCIATED WITH OVERNIGHT CONSTRUCTION. ACTIVITIES WILL REQUIRE WARNING SIGNS BE PLACED AT LEAST ONE WEEK IN ADVANCE OF STARTING CONSTRUCTION. 16. A SOLAR POWERED FLASHING ARROW BOARD SHALL BE REQUIRED ON ALL ARTERIAL STREET LANE CLOSURES. 17. IF THE PERMIT APPLICANT DETERMINES THAT CONDUIT INSTALLATION WILL BE BY THE BORING MACHINE METHOD, THE TRENCH PATCH FOR THE UTILITY OBSERVATION EXCAVATION WILL BE THE SAME AS FOR OPEN TRENCH EXCAVATION METHOD. THIS WILL PROVIDE A SINGLE CONTINUOUS SURFACE RESTORATION ELIMINATING THE MULTIPLE PENETRATION INTO THE THE PUBLIC ROADWAY TO ALL REQUIREMENTS IN CITY STANDARD DRAWING # 407 (SHEET 1 AND 2 ) FOR TRENCH PATCH. 18. ANY WORK THAT CREATES AN UNDUE SAFETY RISK OR CREATES SEVERE CONGESTION MAY BE SHUT DOWN BY CITY TRAFFIC ENGINEERS, CITY FIELD ISPECTION, OR THE POLICE DEPARTMENT. 19. CONES AND DELINEATORS SHALL HAVE REFLECTORIZED SLEEVES FOR NIGHT WORK. 20. IF PARKING IS ALLOWED IN ADVANCE WARNING AREA, ADVANCE WARNING SIGNS SHALL BE MOUTED ON HIGH LEVEL DEVICES. APPLICANT IS RESPONSIBLE FOR FULL AND COMPLETE REPRESENTATION OF THE ACTUAL ROAD CONDITIONS SHOWN ON THIS PLAN INCLUDING, BUT NOT LIMITED TO EXISTING STRIPING, SIGNING, SIDEWALKS, AND BIKE LANES. VICINITY MAP N DE PORTO L A R D .WORK AREA ME A D O W S P K W Y . M A R G A R I T A R D . M A R G A R I T A R D . DE PORT O L A R D . ME A D O W S P K W Y . DRIV E W A Y SE E M A T C H L I N E A PUBLIC WORKS - TRAFFIC ENGINEERING DIVISION CITY OF TEMECULAENGINEER'S INFORMATIONENGINEER'S SEAL FOR TRAFFIC CONTROL PLANS DHS108009CA-HBLTCX46-TEM PERMIT NO. LD23-1497 CONTRACTOR: RECOMMENDED BY: DATE: ACCEPTED BY: DATE: R.T.E. NO. NICOLAS M. MINICILLI TRAFFIC ENGINEER 2647 AT LEAST TWO DAYS UG SERVICE ALERT OF SOUTHERN CALIFORNIA BEFORE YOU DIG DIGALERT Call: TOLL FREE1-800-227-2600 32105 DE PORTOLA RD., TEMECULA, CA 92592 DANIEL EKO INSPECTOR: DATE COMPLETED: BRASH ENGINEERING SERVICES PRESIDENT (714) 446-0635 1 SE E M A T C H L I N E A 1 6/29/2023 06/30/23 07/05/23 Land Development Encroachment Permit 41000 Main Street Temecula, Ca 92590 Phone: 951-694-6444 www.temeculaca.gov R:\LAND DEVELOPMENT DIVISION\Forms\Permit Applications\Word\Encroachment Permit App.docx Page 1 of 2 Revised: 06/16/2020 APPLICATION INFORMATION PERMIT NO.: Type of Encroachment: Street/Storm Drain Sewer/Water Utility Trenching Signing & Striping Traffic Signal Miscellaneous (SPECIFY BELOW) The undersigned hereby applies to excavate, construct and otherwise encroach on City street right-of-way, as follows: Name(s) of street(s) and/or street address: Utility Work Order #: Start Date: End Date: In consideration of granting this application, all applicants including utility companies hereby agree to: 1.If applicable, submit a set of Construction Drawings, Traffic Control Plans, proof of City Business License for all parties involved with this application at the time of submittal. See the Traffic Control Plan Checklist for details. 2. Indemnify, defend and save the City, its authorized agents, officers, representatives and employees, harmless from and against any and all penalties, liabilities or loss resulting from claims or court action and arising out of any accident, loss or damage to persons or property happening or occurring as a proximate result of any work undertaken under the permit granted pursuant to this application. (See below for specific liability insurance requirements.) 3. Remove/relocate any encroachment installed/maintained under this permit, upon written notice from the City Engineer. 4. Notify the Land Development Inspection Division via email at LDInspections@temeculaca.gov at least two (2) working days prior to commencing construction. Hold a pre-construction meeting prior to the start of construction. The developer/general contractor must be present for the timely request of inspections. 5. Comply with the Standard Specifications, most current Improvement Standard Drawings for Public Works Construction, City of Temecula Municipal Code Chapters 13.04 and 18.12, terms and conditions of the permit and all applicable rules and regulations for the City of Temecula and other public agencies having jurisdiction. LIABILITY INSURANCE REQUIREMENTS PROVIDE PROOF OF INSURANCE COVERAGE MEETING THE REQURIEMENTS STATED BELOW OR A CITY ATTORNEY APPROVED EQUIVALENT WITH THE CITY NAMED AS ADDITIONAL INSURED. IN THE EVENT THAT THE INSURANCE IS PROVIDED BY THE CONTRACTOR, THE CITY AND THE OWNER/DEVELOPER MUST BE NAMED AS ADDITIONAL INSURED. THIS REQUREMENT SHALL BE MET BY EITHER THE APPLICANT (DEVELOPER, OWNER, PUBLIC UTILITY AGENCY OR FRANCHISE) OR BY THE CONTRACTOR PERFORMING THE SUBJECT WORK, PRIOR TO BEGININNG ANY WORK PROPOSED UNDER THE SUBJECT ENCROACHMENT PERMIT. Land Development Encroachment Permit 41000 Main Street Temecula, Ca 92590 Phone: 951-694-6444 www.temeculaca.gov R:\LAND DEVELOPMENT DIVISION\Forms\Permit Applications\Word\Encroachment Permit App.docx Page 2 of 2 Revised: 06/16/2020 Proof of coverage shall be by certificate (Accord or equivalent) naming the City of Temecula as certificate holder and the minimum limits of insurance coverage shall be as follows: a.General Liability: One million dollars ($1,000,000) per occurrence for bodily injury, personal injury and property damage. If Commercial General Liability Insurance or other form with a general aggregate limit is used, either the general aggregate limit shall apply separately to this project/location or the general aggregate limit shall be twice the required occurrence limit. b.Automobile Liability: One million dollars ($1,000,000) per accident for bodily injury and property damage. c.One million dollars ($1,000,000) per accident for bodily injury or disease. d.Course of Construction:Completed value of the project. h located in the public right-of-way, may use their homeowners insurance with public liability and property damage coverage in at least the following minimum limits and which will name the City of Temecula as an additional insured for the duration of the encroachment permit: BODILY INJURY $250,000.00 EACH PERSON $500,000.00 EACH OCCURANCE $500,000.00 AGGREGATE PRODUCTS AND COMPLETED OPERATIONS PROPERTY DAMAGE $100,000.00 EACH OCCURANCE $250,000.00 AGGREGATE PRODUCTS AND COMPLETED OPERATIONS A $1,000,000.00 will be considered equivalent to the required minimum limits. Homeowners: a copy of the required homeowners insurance and a Certificate of Insurance showing the City named as an additional insured shall be attached to the application. The undersigned applicant and/or contractor states that they have read and agrees to meet all the conditions on this application, including provisions of required liability insurance or a City Attorney approved equivalent, and acknowledges that this application will be made a part of the encroachment permit. (THIS SECTION MUST BE COMPLETED) Company Name: Mailing Address: Contact: Phone #: E-mail: I hereby warrant and represent to the City that I am authorized to execute this permit application on behalf of the permittee and bind the permittee to the agreements contained herein and any conditions of the permit. Authorized Signature: Date Applied: Company Name: Mailing Address: Contact: Phone #: 24-HR Emergency #: Class: City Business License #: CROWN CASTLE FIBER LLC DHS108009CA-HBLUGX46-TEM 32105 DE PORTOLA RD., TEMECULA, CA 92592 NE N E SESW W NW S T-1200 SPECTRUM CENTER DR. SUITE 1800 IRVINE, CA 92618 SITE NO.: SITE NAME & ADDRESS: HBLUFX46-TEM 32105 DE PORTOLA RD., TEMECULA, CA 92592 ENGINEERING GROUP Strive for Perfection, Settle for Excellence SM 325 W Hospitality Ln Suite 206 San Bernardino, CA 92408 (909) 532-1497 Phone (909) 435-0392 Fax www.maxeng1.com Copyright 2007 by Maximize Communication Group, Inc.c DHS108009CA-HBLUFX46-TEM 37.NO WORK IN ROW AFTER 4PM ON THURSDAYS. 25. NEW PAVEMENT THICKNESS SHALL BE PER CITY STANDARDS. 31. SEE ADDITIONAL NOTES ON THE EXCAVATION PERMIT. 1.ALL WORK SHALL CONFORM TO LATEST EDITION OF THE "STANDARD SPECIFICATION FOR PUBLIC WORKS CONSTRUCTION," ADOPTED BY THE CITY AS MODIFIED BY STANDARD PLANS AND ADDENDUM. 2.THE EXISTENCE AND LOCATION OF UTILITY LINES SHOWN HEREON ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. OTHER UTILITY LINES MAY EXIST; CONTRACTOR SHALL VERIFY PRIOR TO START OF CONSTRUCTION AND SHALL USE EXTREME CARE AND PROTECTIVE MEASURES TO PREVENT DAMAGE TO THE SAME. HE IS RESPONSIBLE FOR THE PROTECTION OF ALL UTILITY LINES, VALVES, METERS, TRAFFIC SIGNAL CONDUIT & DETECTOR LOOPS, ETC.; WITHIN LIMITS OF WORK WHETHER THEY ARE SHOWN ON THESE PLANS OR NOT. 3.AT LEAST TWO WORKING DAYS PRIOR TO STARTING WORK NOTIFY UNDERGROUND SERVICE ALERT (1-800-422-4133). 4.INDEMNIFICATION CLAUSE- CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTIONS OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. 5.ALL WORK AREA AND STREET TRAFFIC CONTROL SHALL BE PER "MUTCD": (MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES), CITY STANDARDS, AND APPROVED BY CITY TRANSPORTATION DEPT. 6.ALL PAVEMENTS, CURBS, GUTTERS, SIDEWALKS, DRIVEWAYS AND OTHER EXISTING IMPROVEMENTS TO BE RECONSTRUCTED SHALL BE RECONSTRUCTED PER THE CITY OF TEMECULA IMPROVEMENTS STANDARD. 7.PRIOR TO THE BEGINNING OF ANY EXCAVATION AND THROUGHOUT THE COURSE OF CONSTRUCTION WORK THE CONTRACTOR SHALL FULLY COMPLY WITH THE CALIFORNIA OCCUPATIONAL SAFETY AND HEALTH ACT OF 1973 INCLUDING ALL REVISIONS AND AMENDMENTS THERETO. 8.THE CONTRACTOR SHALL HAVE COPIES OF THE PLANS ON THE PROJECT SITE AND BE FAMILIAR WITH ALL APPLICABLE STANDARDS AND SPECIFICATIONS. 9.THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO EXISTING ABOVE OR BELOW GROUND IMPROVEMENTS, AS A RESULT OF HIS OPERATIONS, AND SHALL BE RESPONSIBLE FOR REPAIR OR REPLACEMENT OF SAME TO THE SATISFACTION OF THE CITY. 10.ALL BACKHOE EXCAVATION SHALL BE SAW CUT TO FACILITATE REMOVAL BY THE USE OF A POWER DRIVEN SAW. THE DEPTH OF CUT SHALL BE DEEP ENOUGH TO PRODUCE A CLEAN STRAIGHT BREAK. 11.TUNNEL ALL CURBS AND GUTTERS AND BORE ALL DRIVEWAYS AND WALKWAYS. TUNNELED AREAS MAY REQUIRE 1-SACK SLURRY BACKFILL. 12.EXISTING PORTLAND CEMENT CONCRETE SHALL BE SAW CUT TO FACILITATE REMOVAL BY THE USE OF A POWER DRIVEN SAW. THE DEPTH OF CUT SHALL BE DEEP ENOUGH TO PRODUCE A CLEAN, STRAIGHT BREAK WITHOUT CRACKING, CHIPPING OR LOOSENING ADJOINING PCC. THE EXISTING PCC SHALL BE CUT BEYOND THE CONFIGURATION OF THE TRENCH OR EXCAVATION AREA AS MAY BE REQUIRED BY THE PUBLIC WORKS INSPECTOR TO ELIMINATE SMALL "FLOATING" PIECES OF CONCRETE, SUCH AS WHERE THE EXISTING PCC IS DAMAGED OR CRACKED. IN GENERAL, THE REPLACEMENT SHALL BE TO THE EXTENT THAT THERE ARE NO FLOATING PIECES OF PCC LEFT REMAINING WHICH ARE SMALLER THAN 9 SQUARE FEET IN AREA. IN ADDITION, THE SAW CUT LIMITS SHALL BE LOCATED NO CLOSER THAN 3 FEET FROM A SCORE LINE OR COLD JOINT. MIN. PCC REMOVAL IS 25 SQUARE FEET, SCORE LINE TO SCORE LINE. 13.UNLESS OTHERWISE NOTED: 3" CONDUIT BENDS SHALL HAVE A RADIUS OF 3', 2" CONDUIT BENDS SHALL HAVE A RADIUS OF 2'. PLACE 1 SACK SLURRY MIX AROUND ALL CONDUIT BENDS HAVING A RADIUS OF LESS THAN 50'. 14.ALL CONDUIT SHALL BE DB 120, UNLESS OTHERWISE SPECIFIED. ALL SWEEPS TO POLES SHALL BE SCHEDULE 80. 15.REMOVE AND REPLACE CURB AND GUTTER ABOVE SWEEPS TO VAULTS IN THE SIDEWALK, OR BORE UNDER CURB AND GUTTER. JETTING IS NOT ALLOWED. 16.THE CONTRACTOR SHALL NOTIFY THE APPLICABLE DEPARTMENTS OF THE CITY AT LEAST TWO DAYS BEFORE START OF WORK. DURING THE COURSE OF WORK, THE CONTRACTOR SHALL CALL FOR INSPECTION OF ALL APPLICABLE WORK. SCHEDULE A PRE-CON BEFORE START OF WORK. 17.ALL SHRUBS, PLANTS, OR TREES THAT HAVE BEEN DAMAGED OR DISTURBED DURING THE COURSE OF THE WORK SHALL BE REPLANTED OR REPLACED SO AS TO RESTORE THE WORK SITE TO ITS ORIGINAL CONDITION. 18.DURING THE COURSE OF THE WORK, PEDESTRIAN AND VEHICULAR ACCESS MUST BE MAINTAINED AT ALL TIMES. 19.NON-SKID CALTRANS APPROVED STEEL PLATES SHALL BE RECESSED IN TRENCH CROSSING MAJOR STREETS (AREA DESIGNATED BY CITY ENGINEER) AND INSTALLED PER CALTRANS SPECS. PAVEMENT SHALL BE COLD PLANED TO A DEPTH EQUAL TO THE THICKNESS OF THE PLATE AND TO A WIDTH AND LENGTH EQUAL TO THE DIMENSIONS OF THE PLATES. 20.STEEL PLATES USED FOR BRIDGING MUST EXTEND A MINIMUM OF 12" BEYOND EDGES OF TRENCH. 21.TEMPORARY PAVING WITH COLD MIX SHALL BE USED TO FEATHER THE EDGES OF THE PLATES TO MINIMIZE WHEEL IMPACT. CONTRACTOR MAY BE REQUIRED TO WELD PLATES TOGETHER TO MINIMIZE RATTLING. CONTRACTOR MAY BE REQUIRED TO SWEEP UP LOOSE GRAVEL SEVERAL TIMES PER DAY AS DEEMED NECESSARY BY CITY ENGINEER. 22.BRIDGING SHALL BE SECURED AGAINST DISPLACEMENT USING ADJUSTABLE CLEATS, SHIMS OR OTHER DEVICES. 23.RESTORE ALL LANDSCAPING, INCLUDING IRRIGATION SYSTEM AROUND VAULTS. 24.VAULT SHALL BE INSTALLED WITHIN THE RIGHT-OF WAY / SIDEWALK. 26.TACK COAT SHALL BE APPLIED OVER ROADWAY SURFACE PRIOR TO PAVEMENT INSTALLATION. TACK COAT SHALL BE AR-4000 HOT TACK EMULSIFIED ASPHALT PER "CAL TRANS" REQUIREMENTS. 27.3/4 SACK CEMENT/SAND SLURRY BACKFILL. ALL SLURRY BACKFILL WILL REQUIRE 72 HOURS OF CURE TIME. ALL EXCAVATION AND TRENCHES WILL BE SECURED WITH STEEL PLATES. 28.PERMANENT PAVING SHALL BE COMPLETED WITHIN TWO WEEKS AFTER EXCAVATION. TEMPORARY PAVING USING COLD MIX A.C. IS ACCEPTABLE AFTER ALLOWING 72 HOURS OF CURE TIME ON SLURRY MIX BACKFILL. 29.REPLACE ANY EXISTING STRIPING, MARKINGS AND SURVEY MONUMENTS THAT MAY HAVE BEEN REMOVED OR DAMAGED. 30.ACCESS SHALL BE PROVIDED TO ALL FIRE HYDRANTS, VALVES, VAULTS, METERS, AND PULL BOXES AT ALL TIMES. TRAFFIC SIGNALS, PEDESTRIAN SIGNALS AND STOP SIGNS SHALL REMAIN UNOBSTRUCTED AT ALL TIMES. 32.HANDHOLES, VAULT OR SUBSURFACE EQUIPMENT ENCLOSURES SHALL BE MARKED AS TO OWNERSHIP TO FACILITATE IDENTIFICATION BY PERSONS AUTHORIZED BY TO WORK THEREIN AND BY OTHER PERSONS PERFORMING WORK IN THEIR VICINITY. 33.MANHOLES AND HANDHOLES, WHILE NOT BEING WORKED IN SHALL BE SECURELY CLOSED BY COVERS OF SUFFICIENT STRENGTH TO SUSTAIN SUCH LOADS AS MAY REASONABLY BE IMPOSED UPON THEM, AND ARRANGEMENT SHALL BE SUCH THAT A TOOL OR APPLIANCE SHALL BE REQUIRED FOR THEIR OPENING AND COVER REMOVAL. 37.NO WORK IN ROW AFTER 4PM ON THURSDAYS. 36.NO PLATES ALLOWED AFTER 4PM ON THURSDAYS DUE TO FARMER'S MARKET. MUST BACKFILL + PLACE COLD MIX ASPHALT. 35.MAINTAIN 12" CLEARANCE BETWEEN NEW CONDUIT AND ALL OTHER UTILITES. 34.ALL VAULT AND MANHOLES SHALL CONFORM TO APPLICABLE AMERICAN ASSOCIATION OF STATE HIGHWAY OFFICIALS (A.A.S.H.O.) STANDARD SPECIFICATIONS H20-S16-44 FOR HIGHWAY BRIDGES, LATEST REVISION, RELATING TO DEAD LOADS LIVE LOADS, AND IMPACT LOADS. ADDITIONALLY, LOADS DUE TO A GROUND WATER TABLE OF THREE (3) FEET FROM FINISHED GRADE AND A SURCHARGE OF (2) FEET SHALL BE APPLIED IN CALCULATING DESIGN LOADS. / VT PL BP PH P M T F/H MH SL TS MTR SYMBOL/LINETYPE ABBRV. DESCRIPTION CONCRETE RESURFACE ASPHALT RESURFACE PROPOSED TRENCH PROPOSED BORE DIRECT BURIED FIBER POTHOLE ASPHALT BORE PIT DIRT / ASPHALT EU EXPOSE UTILITY VT R&R SYMBOL POLE PROPOSED VAULT PLACE (INSTALL NEW) REMOVE & REPLACE CONC. ABBRV. DESCRIPTION UTILITY POLE MANHOLE HH HH VLV PED M HAND HOLE FIRE HYDRANT PEDESTAL VALVE TRAFFIC SIGNAL STREET LIGHT VENT METER TREE EX I S T I N G S T R U C T U R E S PR O P O S E D W O R K LEGEND E T G LINETYPE SLC DESCRIPTION STREET LIGHT CONDUIT ELECTRIC TELEPHONE/COMM GAS SD SS W TV FO CL STORM DRAIN SANITARY SEWER WATER CATV FIBER OPTIC CENTER LINE LI N E T Y P E S THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THE PLANS WERE MADE BY SEARCHING AVAILABLE EXISTING RECORDS. HOWEVER, NO GUARANTEE IS MADE THAT SUBSTRUCTURES OR THEIR LOCATIONS ARE EXACT. THE CONTRACTOR SHALL TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ALL UTILITY LINES INCLUDING THOSE NOT SHOWN OR NOT ON RECORD BY CALLING DIG ALERT 48 HOURS BEFORE EXCAVATING. CONTRACTOR SHALL EXPOSE AND POT HOLE (HAND DIG) ALL EXISTING UTILITIES WITHIN CONSTRUCTION ZONE. CONSTRUCTION WARNING: Know what's below. Call before you dig. SI5& 2. ASPHALT TRENCH NOTES: EXCAVATION DATA: 1. - CONCRETE STREET/SIDEWALK/ALLEY - ASPHALT STREET/ALLEY - DIRT PARKWAY RESURFACING DATA (LIMITS OF T CUT) - CONCRETE AREA - ASPHALT AREA 1. TRENCH WIDTH AND DEPTH (I.E. TRENCH WIDTH = 12" AND DEPTH TO SUBGRADE = 3'-6"). 2. TRENCH BACKFILL AND A/C PAVEMENT RESURFACING SHALL FOLLOW THE LATEST VERSION OF LA CITY STANDARD PLAN S-477.2 TRENCH WIDTH AND LENGTH FOR THE FOLLOWING: TRENCHING NOTES: 1.TRENCHING , PAVING AND BACKFILL IN ASPHALT PAVEMENT TO BE PERFORMED PER STANDARD PLAN S-477.2 2.CONTRACTORS IS TO IDENTIFY ANY UNDERGROUND UTILITIES WITHIN THE VICINITY BEFORE CONSTRUCTION BEGINS. 3.SEE SUBSTRUCTURE MAP: DISCLAIMER NOTE: MAXIMIZE COMMUNICATION GROUP HAS GENERATED A SITE PLAN WITHOUT USING A TOPOGRAPHIC SURVEY. PROPERTY LINES, POWER/TELCO UTILITY POINT OF CONNECTIONS/ROUTES AND EASEMENT SHOWN ON THESE PLANS ARE ESTIMATED. DE PO R T O L A R D . M A R G A R I T A R D . C A M P A N U L A W A Y DE P O R T O L A R D . PERMIT NO.: LD23-1497 SSSSSSSSSSSSSSSS SD SD SD SD SD SD SD SD SD SD SD SD SD WWWWWWWW GGGGGGGG SS SSSSSSSSSSSS PHHHHHHHH TTT T T MM TT HH M T T TT HH HH HH HH HH HH M TTTTTT M HH M 05 + 0 0 06 + 0 0 07 + 0 0 HH 20'10'0"20' 24"x36" SCALE: 1" = 20'-0" 11"x17" SCALE: 1" = 40'-0" NE N ESE SW W NW S 200 SPECTRUM CENTER DR. SUITE 1800 IRVINE, CA 92618 SITE NO.: SITE NAME & ADDRESS: HBLUFX46-TEM 32105 DE PORTOLA RD., TEMECULA, CA 92592 ENGINEERING GROUP Strive for Perfection, Settle for Excellence SM 325 W Hospitality Ln Suite 206 San Bernardino, CA 92408 (909) 532-1497 Phone (909) 435-0392 Fax www.maxeng1.com Copyright 2007 by Maximize Communication Group, Inc.c DHS108009CA-HBLUFX46-TEM C-1 CITY OF TEMECULA DEPARTMENT OF PUBLIC WORKS BUREAU OF ENGINEERING 1-800-422-4133 AT LEAST TWO (2) DAYS BEFORE YOU DIG UNDERGROUND ALERT OF SOUTHERN CALIFORNIA TICKET #________________ TOTAL LINEAR FOOTAGE: 69' 1 2 PL. 25' (1)-2" DUCT PL. 44' (2)-1 1/4" DUCT AND (1)-2" DUCT AND (1)- 1 1/2" 7 WAY FUTURE PATH 7- WAY MICRODUCT DISCLAIMER: DRAWINGS WERE CREATED WITHOUT MEET-ME-POINT (MMP) DOCUMENT PERMIT NO.: LD23-1497 D-1200 SPECTRUM CENTER DR. SUITE 1800 IRVINE, CA 92618 SITE NO.: SITE NAME & ADDRESS: HBLUFX46-TEM 32105 DE PORTOLA RD., TEMECULA, CA 92592 ENGINEERING GROUP Strive for Perfection, Settle for Excellence SM 325 W Hospitality Ln Suite 206 San Bernardino, CA 92408 (909) 532-1497 Phone (909) 435-0392 Fax www.maxeng1.com Copyright 2007 by Maximize Communication Group, Inc.c DHS108009CA-HBLUFX46-TEM NOT USED 24"x36" SCALE: NTS 11"x17" SCALE: NTS 24"x36" SCALE: NTS 11"x17" SCALE: NTS 24"x36" SCALE: NTS 11"x17" SCALE: NTS NOT USED 30" 30"x48"x18" VAULT DETAIL (N.T.S.) 18" 48" LIFT PIN (2X) BOLTDOWN (4X)STD. MARKING ARMORCAST LOGO NON-SKID SURFACE POLYMER CONCRETE COVER OPENBASE POLYMER CONCRETE BOX NOT USED 24"x36" SCALE: NTS 11"x17" SCALE: NTSNOT USED24"x36" SCALE: NTS 11"x17" SCALE: NTS 24"x36" SCALE: NTS 11"x17" SCALE: NTS 24"x36" SCALE: NTS 11"x17" SCALE: NTS 24"x36" SCALE: NTS 11"x17" SCALE: NTS HANDHOLE DETAIL NOT USED NOT USED NOT USED NOT USED 3 2 1 8 7 6 4 5 PERMIT NO.: LD23-1497 N-1200 SPECTRUM CENTER DR. SUITE 1800 IRVINE, CA 92618 SITE NO.: SITE NAME & ADDRESS: HBLUFX46-TEM 32105 DE PORTOLA RD., TEMECULA, CA 92592 ENGINEERING GROUP Strive for Perfection, Settle for Excellence SM 325 W Hospitality Ln Suite 206 San Bernardino, CA 92408 (909) 532-1497 Phone (909) 435-0392 Fax www.maxeng1.com Copyright 2007 by Maximize Communication Group, Inc.c DHS108009CA-HBLUFX46-TEM N-1 · ’ · “– ” · · ’ · · · · · · · · · · · · ’ ’’ ’ ’ ·” · ’ · PERMIT NO.: LD23-1497