HomeMy WebLinkAboutLD23-4954Permit Number: LD23-4954
LD - Utilities/ Utility Maintenance
Issued: 07/26/2023
Expired: 02/13/2024
Job Address: 31450 De Portola Rd
Legal Description: Tract Map 3752:21
City of Temecula - Land Development Division
41000 Main Street - Temecula, CA 92590
Mailing Address: P.O. Box 9033 Temecula, CA 92589-9033
Phone: (951) 308-6395 Fax: (951) 694-6475
Southern California Edison
298 Kansas Street
Redlands, CA 92373
(909) 307-6884
Applicant:
Ferreira Construction Co., Inc.
10370 Commerce Center Drive, B-200
Rancho Cucamonga, CA 91730
(909) 606-5900
Contractor:
Utility Work Order Number: 904170952
Description:
SCE 904170952; 31450 De Portola Rd
WORK HOURS SHALL BE MONDAY - FRIDAY, NO HOLIDAYS, 8:30am - 3:30pm
Proposed work:
Replace primary cable from X5001620 to X5001618
Permitee Date
City Engineer or Authorized Representative Date
07/26/2023
Page 1 of 1
Bad primary cable from X5001620 to X5001618. CIC. 6.9kv. Bad cable is isolated at X5001620.
Refused fuse cabinet and energized up to J bar at X5001620. Will need traffic control.
Distribution Repair Order
Information:CAD ID: GO 072023-00003 Incident Date:07//20//2023 Time:03:07
Reported by:Schafer, Chris Radio No:9497 Cell Number:(909) 957 0459
Structure No:X5001620 RO Date:07//20//2023 Time:03:07
Problem:No Lights Area Cause:Damaged/Broken UG Primary Cable
Circuit:VELARDO Code 18632 Sub:MORAGA
Location:31450 DE PORTOLA RD, TEMECULA
Access:Street
Seq No:#2144 Foreman:Radio No:Cell Number:
Duration:99 Crew Size:5 Crews Needed:1 Crew Type:DISTRIBUTION
Enviromental Release?No Enviromental Other?No District Notified?No-
Tree Crew Needed?No Grounding Needed for Tree Crew?No
Load Off (Individual or Downstream):
Yes
Other Departments:
TeleComm Transmission Other Utility Other
Equipment Needed:
Double/Tub Bucket Arrowboard Flatbed EasyHauler
Y2K Ped Control Snow Cat Fork Lift
Auger Truck P/L Dolly Air Ops Power Dolly
X UG Van P/L Pole Dolly Four Wheel Drive Crane
Material:
400 ft-1/c #2 JXLP Cable Material Code - _________________
Remarks:(Status of Line, Access Instructions, Special Instructions)
# of Attachments-2
Pg 1 of 3 Seq #- #2144
UCC# 904170952-200 / ECO D: 88 / KH
AGMT: C-3313 / ECO
WO# 904170952
1
Christina Carter
From:Joseph Coats
Sent:Thursday, July 20, 2023 11:32 AM
To:Kenneth Hansen; UG Civil Mailbox San Jacinto Region
Subject:FW: (External):SAP TBD Temecula De Portola Rd Potholing 5001620
FYI …
Thank you,
Joseph Coats
Production Specialist
Wildomar Service Center
joseph.coats@sce.com
M. 951‐870‐9360
24487 Prielipp Rd., Wildomar, CA 92595
From: Victoria Childers <Victoria.Childers@swca.com>
Sent: Thursday, July 20, 2023 6:48 AM
To: Jason Tannery <Jason.Tannery@sce.com>; SCE Emergency <SCEEmergency@swca.com>; Environmental
Requirements <EnvironmentalRequirements@sce.com>
Cc: Joseph Coats <Joseph.Coats@sce.com>; Brian Wright <Brian.Wright@sce.com>
Subject: (External):SAP TBD Temecula De Portola Rd Potholing 5001620
Hi Jason, Thanks for alerting us to the emergency potholing at structure 5001620, 31450 DE PORTOLA RD, TEMECULA. Please provide: An SAP number once one is generated. We have reviewed for bio, waters, and cultural resources concerns. You are
ZjQcmQRYFpfptBannerStart
❚❛❜ CAUTION: This is an external email. Be careful when opening links or attachments
This message was received from outside Edison.
Report Suspicious
ZjQcmQRYFpfptBannerEnd
Hi Jason,
Thanks for alerting us to the emergency potholing at structure 5001620, 31450 DE PORTOLA RD, TEMECULA.
Please provide:
An SAP number once one is generated.
We have reviewed for bio, waters, and cultural resources concerns. You are approved to proceed with the following
standard environmental requirements:
Tailboard Briefing: The Environmental Requirements must be kept on site and be read to the crew prior to starting
work. If any of the requirements create a safety or scope concern, please contact Environmental Services. If additional
ground disturbing or vegetation clearing activities are proposed during project activities, stop work and contact
Environmental Services.
2
Scope of Work Authorization: The following ERD conditions apply to the work outlined in the Scope of Work provided to
ESD. Any changes or additions, including but not limited to construction means and methods, equipment identified,
materials used, extent of grading, scope of vegetation impacting activities, add‐ons, or proposed access routes, must be
reviewed and released by SCE Environmental prior to the start of work.
Minimize work area: The work area shall be minimized to the smallest area necessary to complete the work.
Crew Check: Prior to starting work, crews will check the workspace for bird nests (e.g., pole cavities, vegetation to be
removed). Contact the biological monitor or call the number above prior to work within 200 feet of an active nest.
Cavity Nests: Prior to starting work, crews will check the workspace for cavities in poles and trees. Crews will tap loudly
on poles and trees with potential cavity nests and watch for wildlife leaving the cavity or the sounds of young birds
inside the cavity. If an active cavity nest is suspected, crew must STOP WORK and contact SCE Environmental Services
prior to work.
Injured/Trapped Wildlife: Prior to the start of work, crews will inspect their workspace for any injured or dead
wildlife. In addition, look in holes and trenches, construction material, and equipment for any trapped wildlife. Call the
number above if you observed dead, injured, or trapped wildlife.
Spill Release/Prevention: Vehicles/equipment must be inspected for leaks (e.g., fuel, oil, hydraulic fluids, etc.) and
repaired prior to work. Storing, fueling, and maintenance should not occur near a wetland, waterway, or riparian area.
Spill kits/absorbent clean‐up materials shall be available on‐site and if used, disposed of properly. Contact 1‐844‐GOT‐
SPIL for any potential hazardous material or spills that cannot be cleaned up by spill kits alone.
Avoid Waters and Wetlands: No work is allowed within waters or riparian vegetation unless reviewed and released by
SCE Environmental and all necessary permits have been issued. If unanticipated wetlands, waters, and riparian
vegetation are encountered STOP WORK and contact SCE Environmental.
Driving on road through waters (wet or dry): Only rubber wheeled vehicles and equipment are allowed to travel
through drivable water crossings on existing access roads. No grading or road improvements/repairs/alterations
(e.g., damming, diversions, fill, placement of plates or boards, etc.) are allowed within these areas unless reviewed and
released by SCE Environmental. No stopping within flowing or standing water.
Unanticipated groundwater: If unanticipated groundwater is encountered, STOP WORK and contact SCE
Environmental.
Archaeological/Human Remains/Paleontological Discoveries: If Archaeological resources (Native American or historical
artifacts), fossils, or human remains are encountered, stop work, and call the number above or the SCE Operator 626‐
302‐1212 and ask for an on‐call Archaeologist.
Site re‐contouring: Upon project completion, all disturbed areas must be returned to meet pre‐existing contours (i.e.,
original line and grade).
Weed Maintenance and Prevention: Use certified weed‐free materials (e.g., gravel, straw, and fill) to the extent
practicable. Maintain facilities and infrastructure to limit the introduction and spread of weeds.
Dust Control: No visible dust plumes are allowed. If dust plumes are observed, then slow speeds on dirt roads, water
dirt/work areas, or work when the soil is not extremely dry.
3
Generator Usage: Generators are not allowed unless a Generator Ordering Form (GOF) has been completed 20 days
prior to work. Contact Transportation Services Department (951) 440‐8370 to verify if a form has been received; if no
form has been submitted, contact the SCE representative to complete this form immediately.
Please let me know if you have any questions,
Victoria Childers l she / they
Staff Archaeologist
SWCA Environmental Consultants
3838 Camino Del Rio North, Suite 220
San Diego, CA 92108
O: 619.320-1450 | C: 619.490-6449
victoria.childers@swca.com
Visit Our New Website!
The contents of this email and any associated emails, information, and attachments are CONFIDENTIAL. Use or disclosure without sender’s authorization is
prohibited. If you are not an authorized recipient, please notify the sender and then immediately delete the email and any attachments.
From: Jason Tannery <Jason.Tannery@sce.com>
Sent: Thursday, July 20, 2023 4:49 AM
To: SCE Emergency <SCEEmergency@swca.com>; Environmental Requirements
<EnvironmentalRequirements@sce.com>
Cc: Joseph Coats <Joseph.Coats@sce.com>; Brian Wright <Brian.Wright@sce.com>
Subject: WILDOMAR 88/5001620
Good Morning,
Need an environmental clearance for bad primary cabler, this is “EMERGENT WORK” E1P1, No EHSF Sync or ESF has
been submitted.
Bad cable is along De Portola Rd in dirt within 2’‐4’ from asphalt. Does not look to be near water way, area that will be
worked is from splice box X5001620 to X5001618 approx 400’. We will be digging 2‐3 pothole approx. 3’x5’x3’. We will
expand this request if we need to install conduit between the splice boxes.
No 900# has come through yet.
Work to commence upon receipt of the environmental clearance.
Thank you,
Jason Tannery
Operations Supervisor
Wildomar Service Center
M. 951‐201‐7104
24487 Prielipp Rd. Wildomar, Ca 92585
Pg 2 of 3 Seq #- #2144
Pg 3 of 3 Seq #- #2144