Loading...
HomeMy WebLinkAboutLD23-5845Permit Number: LD23-5845 LD - Utilities/ Utility Maintenance Issued: 09/06/2023 Expired: 09/18/2024 Job Address: Felix Valdez Rd Ne/S 400' Se/O Baldaray Cir Legal Description: City of Temecula - Land Development Division 41000 Main Street - Temecula, CA 92590 Mailing Address: P.O. Box 9033 Temecula, CA 92589-9033 Phone: (951) 308-6395 Fax: (951) 694-6475 Southern California Edison 298 Kansas Street Redlands, CA 92373 (909) 307-6884 Applicant: Contractor: Utility Work Order Number: TD2125789/TD2155004 Description: SCE TD2125789/TD2155004: Felix Valdez Rd NE/S 400' SE/O Baldaray Cir WORK HOURS SHALL BE MONDAY – FRIDAY, NO HOLIDAYS, 8:30am - 3:30pm Proposed work: Replace transformer pad P5367746 Permitee Date City Engineer or Authorized Representative Date 09/06/2023 Page 1 of 1 RI_3DJH PWRD-88 Request for“Underground Civil Contract Construction &Inspection”)RUP 3:5'5HTXHVWIRU³8QGHUJURXQG&LYLO&RQWUDFW&RQVWUXFWLRQ ,QVSHFWLRQ´0DUFK District NameApprover’s Name (Print)TitleSignatureDate SAP Order#:DIMP:UG Civil Only Work Order: Notification#: DIMP Due Date: MAT Code: Requestor:Requestor's Contact Number: Description of Work: Location:City: Structure#: (Must be provided and clearly marked on the maps) SCE GeoView Grid# / FIM#: Circuit: (Must include readable map w/pkg.) Substation:Environmental Requirements Document Required: (For example: Ground and/or vegetation disturbing activities) Permit Required: 0XVWEHLQFOXGHGLQSDFNDJH  NOTE: All permits including Blankets must be included in package at time of submission. Reason: 3ULYDWH3URSHUW\ 2WKHU* * ,)³27+(5´3529,'(&203/(7(9$/,'5($621 Easement Required: Easement Secured: Work Order Type (Select the appropriate category): L &XVWRPHU2XWRI3RZHU,PPHGLDWH'DQJHUWRWKH3XEOLF LL 2XWDJHRU(OHFWULFDO&UHZ0HHW5HODWHG &RQWDFW1DPH: 3K LLL 7KLUG3DUW\&RQQHFWLRQ &RQWDFW1DPH3K LY 0 03URMHFW Proposed Civil Construction Start Date: Emergency Reason: Required Civil Completion Date: MATERIAL TYPE (DESCRIPTION)QUANTITY E-Crew Meet Date:Time: UNITOFMEASUREUNITCOST (PRICE) EXTENDED COST TOTAL ESTIMATED COST (Sheet A): $ TOTAL ESTIMATED COST (Sheet B): $ GRAND TOTAL ESTIMATED COST (Sheet A+B): $ Documentation of Actual Cost Required:Send to:(PDLO$GGUHVV For Underground Construction Use Only SCE Inspector:UCC Release#P-Req / PO# Contractor:Electrical Partner:QA Included: Construction Comments: 1RQ(PHUJHQF\&DOO2XW (&2 ZRUNUHFHLYHG H[HFXWDEOHZRUNRUGHUSDFNDJH ZLWKDUHTXLUHGVWDUWGDWHRIVL[  EXVLQHVV GD\VRUOHVV GDWHVFDQQRWEHDGMXVWHG 6KDOOEHSHUIRUPHGXQGHUWKH7(0&RQWUDFW 3OHDVHUHDFKRXWWRWKHDUHD8*&LYLO,QVSHFWRURU$GYLVRUIRUDQ\DVVLVWDQFHZLWKFRPSOHWLQJWKLVIRUP 88 - WILDOMAR TD2155004 NO NO ENTER NOTIF#ENTER NOTIF# DUE DATE 2M8 - XFMR UG ELECT REPL MARIBEL BLINN (951) 928-8342 REMOVE TRANSFORMER 48"x54" PAD, INSTALL 48"X54" PAD W/ HH 28465 FELIX VALDEZ P/P, 170' W/O 6TH ST. TEMECULA P5388747 MT-8506-H4 DIAZ 12KV MORAGA YES N/A NO ✔ NO ✔ ENTER DATE ENTER TIME REPLACE XFMR POLY PAD 48X54 & EXCAVATION 1 EACH $ 4,300.00 $ 4,300.00 EACH $0.00 FEET $0.00 FEET $0.00 EACH $0.00 EACH $0.00 $ 4,300.00 $0.00 $ 4,300.00 NO NO               02/15/24 SH FCC TD2155004-300 PR243466/ C-3317 ENVIRONMENTAL REQUIREMENTS TD2155004 PREVENTIVE MAINT (ELECTIVE OPTChange Request: 408613ESF #:ESF Project Details: Detailed Description DistributionProject Type: Infrastructure Replacement (All Others)Distribution Activity Type: DIAZ 12KV % MORAGACircuit / Facility Name: Transmission Activity Type: San JacintoRegion: WildomarDistrict: Transmission Grid: Project Coordinates Unique Id Coordinates Label Unique Id Coordinates Label Unique Id Coordinates Label Unique Id Coordinates Label 001 P5388747 Auto-SC+EZ+CSWClearance: Notes N/A Clearance Conditions Proceed with Work. Read and follow the requirements for field work below. Environmental concerns can be answered at ENVIRONMENTALREQUIREMENTS@SCE.COM or call 833-723-2362 (833-SCE2ENC). ENVIRONMENTAL REQUIREMENTS Site Stabilization: Excess soil from ground disturbing activities shall be compacted or stabilized to return the area to pre- construction conditions or disposed of at SCE approved facility per Operating Unit standard practice. For storm water related questions, please call the number above. Tailboard Briefing: This document must be kept on site. The Environmental Requirements will be read to the crew to ensure requirements are understood prior to starting work. If any of these requirements are infeasible given a safety or scope concern, please contact Environmental Services at the email or phone number above. Vegetation: No vegetation/tree removal or trimming/mowing was approved for this project. Work Areas: Vehicles and equipment must remain on the existing access routes and immediate vicinity of towers/work areas identified in the project scope. If any work needs to be conducted outside these access routes or work areas, please contact Environmental Services at the email or phone number above. Crew Check: Prior to starting work, crews will check the workspace for bird nests (e.g., pole cavities, vegetation to be removed). Call the number above prior to work within 200 feet of an active nest. Trapped Wildlife: Prior to the start of work, crews will look in holes and trenches, construction material, and equipment. If wildlife has become trapped call the number above. Spill Release/Prevention: Vehicles/equipment must be inspected for leaks (e.g., fuel, oil, hydraulic fluids, etc.) and repaired prior to work. Fueling should not be conducted near a drainage feature. Spill kits/absorbent clean-up materials shall be available onsite and if used, disposed of properly. Archaeological/Human Remains/Paleontological Discoveries: If Archaeological resources (Native American or historical artifacts), fossils, or human remains are encountered, stop work, and call the number above or the SCE Operator 626-302-1212 and ask for an on-call Archaeologist. Eagle-Safe: This project is within an SCE-defined Eagle Zone. Construct the new structures to be eagle-safe according to SCE Construction Standards. Related Objects Leading Object of the Change Request: Maintenance OrderType:TD2155004Object:PREVENTIVE MAINT (ELECTIVE OPTION) Object Type Object Description Added by Maintenance Order TD2155004 PREVENTIVE MAINT (ELECTIVE OPTION)Rosalind Locklin People Involved Role Business Partner Name E-Mail Telephone Initiator 10010963 Rosalind Locklin ROSALIND.LOCKLIN@SCE.COM 951-249-8445 ESF Coordinator 10165843 ESF Coordinator ESFCoordinator@sce.com From: $ppAdm4 Sent: Monday, July 24, 2023 12:34 PM To: 88 Permit/SCE/EIX Cc: Rosalind Locklin; Daniel Jauregui Subject: 2125789 - Temecula Importance: Low PERMIT REQUEST FORM Your request has been successfully submitted. The permit manager for the area designated has been notified and will be reaching out to you shortly should they require additional information. Date Created : 07/24/2023 Organization : Technical Planning Work Group : DPM District : 88 TD/SAP # : 2125789 PIF # : Date Permit Needed By : Approximate Start Work Date : Compliance Due Date : 2024-12-02 Project Location : FELIX VALDEZ AND 6TH ST, TEMECULA Agency Name : Temecula Agency Type : City Description of Work : TO BE WORKED WITH ADD'L TD2155004 - 2024 UG STRUCTURE REPLACEMENT DIAZ 12KV % MORAGA Estimated work Duration (Civil+Electrical) : P-SPEC Name / Phone : JPA Required : False Outage Required : Pedestrian Traffic Control Required : False Structure Location : In Roadway Structure/Pole Number : P5367746 Trench Location : Excavation Dimensions : Attachments : TD2125789 & TD2155004_FINAL WO MAP.pdf After the Fact : No Comments : High Fire : Yes The linked image cannot be displayed. The file may have been moved, renamed, or deleted. Verify that the link points to the correct file and location. 2314 1 3 421234 S 2 R A G 53 614 2 31 1 2 4231 V5010855 RCS0990 POS 1 4213 P5359450 RCS1882 POS 3 4 1 3 2 321 2 3 4 1 312 4 1 3 4 R A G 2 21 34 1 3 42 21 43 3 21 4 4 2 3 1 V5010853 RCS0922 POS 1 431 R AG 2 B A A B AB A B A B A B A B BA A B B A B AAB 0178308 1800 P5389680 A 0178606 1200 P5389682 A FI07701 POS.3 F I 0 7 6 9 8 P O S .4 400A FI00654 POS.6 600A FI00174 POS.5 F I 0 7 6 9 7 P O S .2 F I 0 7 7 00 P O S .3 1 5 F R W Y M O R E N O F R O N T MORENO 6 T H S T N O _N A M E 6 T H F E LIX V A L D E Z 6 T H S T 43186 VIA DOS PICOS 43122 VIA DOS PICOS J851 X5469104 J857A J857B SEWER PUMP WATER PUMP J856A P5476922 P5476921 J921A X5492145 IN VENT PIPE 2 CLP JO77A J996A J745A P5175075 P5544819 P5544818 CHABLIS V5196551 GS1055 MORAGA V5206399 ADAPTABLE GS1054 J399A P5542730 P5460394 P5460421 P5460420 P5343860 P5425835 PT JBAR P5171448 P5635177 P5492368 X5176851 2500 KVA P5506597 PME4073 P5506598 P5010941 X5010940 P5469105 P5734123 P5171449 P5460118 P5301743 A D A P T A B L E V5010857 GS0924 P5177158 X5544715 X5177159 P5362025 P5544716 CALLAWAY P5321523 P5152354 V5010856 P5476923 500KVA GS0923 X5018648 P5001344 P5510259 P5445584PT CHABLIS MORAGA N P5510258 P5177365 X5510257 J584A P5544817 J450A V5654942 CHABLIS MORAGA P5492147 P5492146 P5306339 P5310714 X5310713 GS0989 V5171434 P5654956 PME7687 V5654941 P5506637 N P5654954 P5543515 S5205077 A D A P T A B L E PT V5171435 GS7695 CHABLIS P5316182X5315996 1000 JCN MORAGA P5342892 X5310746 P5315997 P5310747P5321334 V5171433 GS0988 A D A P T A B L E P5171948 X5171949 P5466295 P5541603 P5550702 V5171432 GS0987 P5196984 V5171431 GS0986 P5177163 P5312788 P5177185 P5530661 J374A P5549912 P5359374 PME2386 P5506663 P5315702 P5549913 P5384097 P5549914 P5387561 P5359373 PME2341 J373BJ373A M5315983 N MORAGA P5368745 P5367746 PMS1886 M5171430 X5530657 P5196831 P5310739 P5367747 P5530658 FC5430 P5388747 P5530659 X5530660 J660A 1/0 CLP 2 C L P 1/0 JCN 2 CLP 1 0 0 0 C L P 1 /0 J C N2 C L P 2 C LP 2 C LP 2 C LP 7 5 0 C L P 1/ 0 J C N 1/0 JCN 1/0 JCN 1/0 JCN 1 00 0 J CN 100 0 J CN 10 0 0 J C N 1 0 0 0 J C N 1/0 JCN 1000 JCN 1000 JCN 2 C L P 3 5 0 C L P 2 CLP 350 CLP 1000 JCN 2 CLP 350 CLP 2 C L P 2 C L P 2 CLP 2 CLP B Ø 1/0 C L P B Ø 1/0 C L P B2 B U S I N E S S P A R K D R B U S I N E S S P A R K D R R A N C H O W Y D I A Z R D F R O N T D I A Z R D BUSINESS PARK DR 2 JCN SINGLE OAK R A N C H O C A L I F O R N I A R D RIDGE PARK DR V I N C E N T M O R A G A F E L I X V A L D E Z V I N C E N T M O R A G A B A L D A R A Y R I D G E G A T E RIDGE PARK DR P U J O L S T R A N C H O C A LIF O R N I A 5 T H S T P U J O L S T 4 T H S T M AIN S T BØ BØ AØ AØ AØ BØ BØ AØ AØ AØ Contact USA Dial 811 or 800-422-4133 UNDERGROUND SERVICE ALERT www.digalert.org/contact CRITICAL ENERGY INFRA STRUCTURE INFORMATION (CEII)This information is class ified as CEII a s defined in 18 Code of Federal Regulatio ns se ctio n 388.113(c)(1), should be trea te d as suc h, a nd sho uld not be supplied to third -pa rty/non-SC E entities withou t the re quired authorization/ap pro val in adva nce pe r SCE-OPS-CEII-PL-451. Th e information is inten ded to be us ed for re fe ren ce only as it is not a legal re prese ntation o f re al property. This information may no t be electron ic ally or phy sically copie d or distrib uted without the ex press written pe rmiss ion o f Southern C alifornia Edison . Remin der to contact “Dig Alert” a t 811 p rior to site excavation. P r i n t e d : 0 5 -1 0 -2 0 2 3 0 50 10025 Feet1:600 W I L D O M A R T E M E C U L A , R I V E R S I D EMT-8 5 0 6 -H 2 Tota l P a ge s: 2 M T -8 5 0 6 -F 4 M T -8 5 0 6 -H 4 M T - 8 5 0 6 - H 1 M T - 8 6 0 6 - G 1 CRITICAL ENERGY INFRA STRUCTURE INFORMATION (CEII)This information is class ified as CEII a s defined in 18 Code of Federal Regulatio ns se ctio n 388.113(c)(1), should be trea te d as suc h, a nd sho uld not be supplied to third -pa rty/non-SC E entities withou t the re quired authorization/ap pro val in adva nce pe r SCE-OPS-CEII-PL-451. Th e information is inten ded to be us ed for re fe ren ce only as it is not a legal re prese ntation o f re al property. This information may no t be electron ic ally or phy sically copie d or distrib uted without the ex press written pe rmiss ion o f Southern C alifornia Edison . Remin der to contact “Dig Alert” a t 811 p rior to site excavation. P r i n t e d : 0 5 -1 0 -2 0 2 3 0 50 10025 Feet1:600 W I L D O M A R T E M E C U L A , R I V E R S I D EMT-8 5 0 6 -H 4 Tota l P a ge s: 2 M T -8 5 0 6 -H 2 M T -8 5 0 5 -B 2 M T - 8 5 0 6 - H 3 M T - 8 6 0 6 - G 3 CRITICAL ENERGY INFRA STRUCTURE INFORMATION (CEII)This information is class ified as CEII a s defined in 18 Code of Federal Regulatio ns se ctio n 388.113(c)(1), should be trea te d as suc h, a nd sho uld not be supplied to third -pa rty/non-SC E entities withou t the re quired authorization/ap pro val in adva nce pe r SCE-OPS-CEII-PL-451. Th e information is inten ded to be us ed for re fe ren ce only as it is not a legal re prese ntation o f re al property. This information may no t be electron ic ally or phy sically copie d or distrib uted without the ex press written pe rmiss ion o f Southern C alifornia Edison . Remin der to contact “Dig Alert” a t 811 p rior to site excavation. P r i n t e d : 0 7 -2 0 -2 0 2 3 0 50 10025 Feet1:600 W I L D O M A R T E M E C U L A , R I V E R S I D EMT-8 5 0 6 -H 3 Tota l P a ge s: 3 M T -8 5 0 6 -H 1 M T -8 5 0 5 -B 1 M T - 8 5 0 6 - G 4 M T - 8 5 0 6 - H 4 BØ BØ AØ AØ AØ BØ BØ AØ AØ AØ Contact USA Dial 811 or 800-422-4133 UNDERGROUND SERVICE ALERT www.digalert.org/contact 12 ' **TO BE DETERMINED BY THE CITY OF TEMECULA** RE V ' D 0 4 / 0 3 / 23 FELIX VALDEZ AVE 100'100'100'63' 63'100'100'100' **PROPOSED WORK HOURS ARE 1230 TO 1500 1 DAY OF WORK LD24-0223 N 383' S/O BALDARAY CIR RE V ' D 0 4 / 0 3 / 23 25MPH BALDARAY CIR 63'100'25' LD24-0223