HomeMy WebLinkAboutLD23-7097Permit Number: LD23-7097
LD - Utilities/ Excavation - Street Crossing
Issued: 02/07/2024
Expired: 09/23/2024
Job Address: 44535 Bedford Ct
Legal Description:
City of Temecula - Land Development Division
41000 Main Street - Temecula, CA 92590
Mailing Address: P.O. Box 9033 Temecula, CA 92589-9033
Phone: (951) 308-6395 Fax: (951) 694-6475
Jose Guillen
17890 Valley Blvd
Bloomington, CA 92316
Applicant:
Contractor:
Utility Work Order Number: 4864798
Description:
Spectrum; Place new Conduit; WO 4864798
Location: 44535 Bedford Ct
Work Hours: Mon-Fri 830AM - 330PM
Scope of work:
Bore/Trench 1,055' to place new 3'' conduit. Remove and replace asphalt (120 sq.ft). Remove and replace
concrete (208 sq.ft). 7 working days
All facilities shall be installed in accordance with City Standard Drawing 117.
Traffic Control shall be in accordance with approved Traffic Control Plan LD23-7097
Permittee shall comply with all applicable Traffic Control General Notes.
Safe pedestrian/bicycle traffic and driveway access shall be maintained at all times.
Concrete repair shall be in accordance with City Standards and the Greenbook.
Trench repair shall be in accordance with City Standard Drawing 407.
Final compaction test results shall be provided by a soils engineer.
Concrete curbs, walks, gutters, cross gutters and driveway approaches damaged during construction shall be
removed from joint to joint and reconstructed in accordance with City Standards and the Greenbook.
All disturbed landscaping and other improvements shall be removed/repaired and replaced to the satisfaction of
Public Works Inspector.
Permittee shall contact LDInspections@temeculaca.gov a minimum of two (2) business days prior to any work.
Page 1 of 3*****See Page 2 of this Permit for Permittee Responsibilities*****
Permit Number: LD23-7097
LD - Utilities/ Excavation - Street Crossing
Permittee must also request a final inspection, via LDInspections@temeculaca.gov, to verify completion of
project.
Permittee Responsibilities
This Permittee agrees to indemnify, defend and save the City, its authorized agents, officers, representatives and employees,
harmless from and against any and all penalties, liabilities or loss resulting from claims or court action and arising out of any
accident, loss or damage to persons or property happening or occurring as a proximate result of any work undertaken under
the permit granted pursuant to this application.
Trench repair shall be pursuant to City of Temecula Standard Drawing No. 407.
3.Traffic control devices shall be utilized to protect and control pedestrian and vehicular traffic in the construction
area in accordance with the latest revision of the “Manual of Uniform Traffic Control Devices for Streets and
Highways” (MUTCD). The contractor shall submit a specific traffic control plan for review and approval by the
City in accordance with City “Traffic Control Plan Guidelines” for all work within Major Circulation Element
streets.
2.BEFORE YOU DIG - CALL (TOLL FREE) 800-422-4133
A pre-construction meeting is required two (2) business days prior to any scheduled work. Permittee
shall contact LDInspections@TemeculaCA.gov to schedule a meeting.
1.
4.
Water Quality: Contractor shall remain in compliance with the City Water Pollution Control Ordinance.
Contractor is required to provide protection of the City storm drain system.
5.
Work hours shall be limited between 7:30 AM and 4:30 PM, Monday through Friday, unless otherwise noted.
No work shall be allowed during City-recognized holidays."
6.
THIS PERMIT IS ISSUED AND ACCEPTED SUBJECT TO THE FOLLOWING CONDITIONS AND ANY ATTACHED
PROVISIONS:
All U.S.A. mark outs shall be removed prior to completion of project.7.
8.All contractors and subcontractors shall have a valid City of Temecula business license and valid Certificate of
Liability prior to start of work.
9.Should there be any claim against the City and the property owner with the encroachment being the proximate
cause, the property owner shall be notified in writing to remove the encroachment within 30 days or the City will
remove and bill the owner.
10.Permission is hereby requested to encroach into public right of way to perform work as set forth above. It is
understood that this permit is limited to the work described herein and that all work is to be done in compliance
with the provisions attached to this permit and with all other applicable rules. Permittee shall be responsible
for said compliance, for acceptability of the work, for repair or replacement thereof if defective, and for repair or
replacement of any existing improvement damaged by the doing of the work
I hereby certify and agree on behalf of the Permittee that all laws, regulations and ordinances of the City of
Temecula and the State of California and the terms and conditions of the Permit shall be complied with whether
herein stated or not.
11.
12.I hereby warrant and represent to the City that I am authorized to execute this Permit Application on behalf of
the Permittee and bind the Permittee to the agreements contained herein and any conditions of the Permit.
******Contractor and all subcontractors shall be present at the pre-construction
meeting; otherwise, the meeting will be rescheduled to a later date******
Any work commencing within the City right-of-way before permit issuance or a pre-construction meeting shall
be subject to a 72-Hour suspension of said work and an assessment of double permit fees.13.
Permitee Date
Page 2 of 3
Permit Number: LD23-7097
LD - Utilities/ Excavation - Street Crossing
City Engineer or Authorized Representative Date
02/07/2024
Page 3 of 3
Land Development
Encroachment Permit
41000 Main Street
Temecula, Ca 92590
Phone: 951-694-6444
www.temeculaca.gov
R:\LAND DEVELOPMENT DIVISION\Forms\Permit Applications\Word\Encroachment Permit App.docx Page 1 of 2 Revised: 06/16/2020
APPLICATION INFORMATION PERMIT NO.:
Type of Encroachment: Street/Storm Drain Sewer/Water Utility Trenching
Signing & Striping Traffic Signal Miscellaneous (SPECIFY BELOW)
The undersigned hereby applies to excavate, construct and otherwise encroach on City street right-of-way, as
follows:
Name(s) of street(s) and/or street address:
Utility Work Order #: Start Date: End Date:
In consideration of granting this application, all applicants including utility companies hereby agree to:
1. If applicable, submit a set of Construction Drawings, Traffic Control Plans, proof of City Business License for all parties
involved, proof of Contractor’s License along with this application at the time of submittal. See the Traffic Control
Plan Checklist for details.
2. Indemnify, defend and save the City, its authorized agents, officers, representatives and employees, harmless from
and against any and all penalties, liabilities or loss resulting from claims or court action and arising out of any accident,
loss or damage to persons or property happening or occurring as a proximate result of any work undertaken under
the permit granted pursuant to this application. (See below for specific liability insurance requirements.)
3. Remove/relocate any encroachment installed/maintained under this permit, upon written notice from the City
Engineer.
4. Notify the Land Development Inspection Division via email at LDInspections@temeculaca.gov at least two (2) working
days prior to commencing construction. Hold a pre-construction meeting prior to the start of construction. The
developer/general contractor must be present for the timely request of inspections.
5. Comply with the Standard Specifications, most current Improvement Standard Drawings for Public Works
Construction, City of Temecula Municipal Code Chapters 13.04 and 18.12, terms and conditions of the permit and all
applicable rules and regulations for the City of Temecula and other public agencies having jurisdiction.
LIABILITY INSURANCE REQUIREMENTS
PROVIDE PROOF OF INSURANCE COVERAGE MEETING THE REQURIEMENTS STATED BELOW OR A CITY ATTORNEY APPROVED
EQUIVALENT WITH THE CITY NAMED AS ADDITIONAL INSURED. IN THE EVENT THAT THE INSURANCE IS PROVIDED BY THE
CONTRACTOR, THE CITY AND THE OWNER/DEVELOPER MUST BE NAMED AS ADDITIONAL INSURED.
THIS REQUREMENT SHALL BE MET BY EITHER THE APPLICANT (DEVELOPER, OWNER, PUBLIC UTILITY AGENCY OR FRANCHISE) OR
BY THE CONTRACTOR PERFORMING THE SUBJECT WORK, PRIOR TO BEGININNG ANY WORK PROPOSED UNDER THE SUBJECT
ENCROACHMENT PERMIT.
x
Work is being done for Spectrum.
Bore/Trench 1,055' to place new 3'' conduit. Remove and replace asphalt (120 sq.ft). Remove and
replace concrete (208 sq.ft). 7 working days
44535 Bedford Ct, Temecula CA 92590
4864798 11-28-2023 12-7-2023
LD23-7097
CLEARED BY
CITY OF TEMECULA
PUBLIC WORKS
david.pina 12/13/2023
12/13/2023 12/13/2023
12/13/20
Land Development
Encroachment Permit
41000 Main Street
Temecula, Ca 92590
Phone: 951-694-6444
www.temeculaca.gov
R:\LAND DEVELOPMENT DIVISION\Forms\Permit Applications\Word\Encroachment Permit App.docx Page 2 of 2 Revised: 06/16/2020
Proof of coverage shall be by certificate (Accord or equivalent) naming the City of Temecula as certificate holder and the minimum
limits of insurance coverage shall be as follows:
a. General Liability: One million dollars ($1,000,000) per occurrence for bodily injury, personal injury and property damage. If
Commercial General Liability Insurance or other form with a general aggregate limit is used, either the general aggregate lim it
shall apply separately to this project/location or the general aggregate limit shall be twice the required occurrence limit.
b. Automobile Liability: One million dollars ($1,000,000) per accident for bodily injury and property damage.
c. Worker’s Compensation as required by the State of California; Employer’s Liability: One million dollars ($1,000,000) per accident
for bodily injury or disease.
d. Course of Construction: Completed value of the project.
There is a limited exception to this requirement. Owners of single family homes doing work on the home’s driveway approac h
located in the public right-of-way, may use their homeowners insurance with public liability and property damage coverage in at
least the following minimum limits and which will name the City of Temecula as an additional insured for the duration of the
encroachment permit:
BODILY INJURY $250,000.00 EACH PERSON
$500,000.00 EACH OCCURANCE
$500,000.00 AGGREGATE PRODUCTS AND COMPLETED OPERATIONS
PROPERTY DAMAGE $100,000.00 EACH OCCURANCE
$250,000.00 AGGREGATE PRODUCTS AND COMPLETED OPERATIONS
A combined single limit homeowner’s policy with aggregate limits in the amount of $1,000,000.00 will be considered equivalent to
the required minimum limits. Homeowners: a copy of the required homeowners insurance and a Certificate of Insurance showing
the City named as an additional insured shall be attached to the application.
The undersigned applicant and/or contractor states that they have read and agrees to meet all the conditions on this
application, including provisions of required liability insurance or a City Attorney approved equivalent, and acknowledges
that this application will be made a part of the encroachment permit.
APPLICANT’S INFORMATION (THIS SECTION MUST BE COMPLETED)
Company Name:
Mailing Address:
Contact: Phone #: E-mail:
I hereby warrant and represent to the City that I am authorized to execute this permit application on behalf of the
permittee and bind the permittee to the agreements contained herein and any conditions of the permit.
Authorized Signature: Date Applied:
CONTRACTOR’S INFORMATION
Company Name:
Mailing Address:
Contact: Phone #: 24-HR Emergency #:
State Contractor’s License #: Class: City Business License #:
7337 Central Ave, Riverside, CA 92504
951-565-1681Tyrone Hawkins Tyrone.Hawkins@charter.com
Spectrum
HHS Communications
2042 S. Grove Ave, Ontario, CA. 91761
049178818906
Veronica Barrozo 909-721-3785 909-376-4938
A C31 C10 B C-7
11-14-2023
36" LE
N
G
T
H
24"
W
I
D
T
H
18
"
H
E
I
G
H
T
3" CONDUIT
36
"
T
Y
P
.
CO
N
D
U
I
T
D
E
P
T
H
18
"
D
E
P
T
H
EXISTING GRADE OR
SURFACE OF CONCRETE
MOUNT FLUSH
WITH GRADE
6" ROCK BASE
(3/4" GRAVEL)
36" LE
N
G
T
H
18"
W
I
D
T
H
20
"
H
E
I
G
H
T
CO
V
E
R
18
"
H
E
I
G
H
T
BA
S
E
21
"
A
B
O
V
E
GR
A
D
E
COVER
3" CONDUIT
36
"
T
Y
P
.
CO
N
D
U
I
T
D
E
P
T
H
EXISTING GRADE OR
SURFACE OF CONCRETE
17
"
D
E
P
T
H
BASE 6" ROCK BASE
(3/4" GRAVEL)
Ø
2
.
8
6
4
"
Ø 3.164"
0.
3
0
0
"
TYPICAL CATV 2'x3' VAULT DETAIL TYPICAL CATV PEDESTAL DETAIL
CONDUIT DETAIL
6'
3'2'
4'
3" HDPE
MIN. 36"
EXIST. GRADESEND
BORE PIT
RECEIVE
BORE PIT
3" CONDUIT
FIBER OPTIC
CABLE
TRACER WIRE
3" HDPE
FIBER
OPTIC CABLE
3/8" TRACER WIRE
3" CONDUIT 3" CONDUIT
TYPICAL DIRECTIONAL BORE DETAIL TRACER WIRE DETAIL INTERDUCT DETAIL
EXISTING GRADE
HORIZONTAL SCALE: 1" = 40'
VERTICAL SCALE: 1" = 4'
36" - 48" COVER
C/
L
O
F
S
T
R
E
E
T
12" CLEARANCE
PLACE 1-3"
CONDUIT AT
36" - 48" DEPTH
EXISTING UTILITIES
(NOTE: DEPTH MAY
VARY FOR
DIFFERENT
UTILITIES)
TYPICAL UTILITY CLEARANCE
(PROTECT IN PLACE AT ALL EX. UTILITY CROSSINGS)
ELECTRIC LINE GAS LINE
TELEPHONE LINE
WATER LINE
CATV LINE
TRAFFIC SIGNAL LINE
SEWER LINE
STORM DRAIN LINE
FIBER OPTIC LINE
PETROLUEM LINE
STREET LIGHTS
INDUSTRIAL WASTE
OIL LINE
FUEL LINE
RECLAIMED WATER
PROPOSED CONSTRUCTION
PROPOSED HDD BORE / CONDUIT INSTALLATION
PROPOSED TRENCH / CONDUIT INSTALLATION
PROPOSED POTHOLE (2'x2')
PROPOSED EXIT / MISSILE BORE PIT (2'x4')
PROPOSED BORE PIT (3'x6')
CATV PROPOSED NEW CATV VAULT (2'x3')
UTILITY / LINE LEGEND
EDGE OF PAVEMENT
CURB FACE
RIGHT OF WAY (CITY)
CENTERLINE (C/L)
N
DESIGN ORIENTATIONREVISIONS
REV#DATE DESCRIPTION
CONSTRUCTION
SHEET 1 OF 2
TP TELEPHONE PEDESTAL
T TELEPHONE VAULT
EV ELECTRIC VAULT
CATV VAULT
IV IRRIGATION VAULT
UTILITY POLE
FIRE HYDRANT
UNDERGROUND VALVE
MAN HOLE
F
M
SL STREET LIGHT VAULT
TS TRAFFIC SIGNAL VAULT
WV WATER VAULT
CATV PEDESTALABOVE GROUND VALVE
GV GAS VAULT
FO FIBER OPTIC VAULT
CV COMMUNICATIONS VAULT
T
EXISTING OBJECTS
S/W
D/W
PH
R/W
EX
C/L
EOP
CF
ABBREVIATIONS
V
PED
PTIMUM, INC.
GENERAL ENGINEERING CONTRACTORS
OFFICE: (909) 990-0767
CSLB#: 817291 | CLASS: C-7 A C31
17890 VALLEY BLVD BLOOMINGTON CA
7337 CENTRAL AVE RIVERSIDE CA.92504
OFFICE: (833) 267-6097
44535 BEDFORD CT
TEMECULA, CA.
-
JESUS SAMANIEGO
HHS CONSTRUCTION
11-10-2023
PENDING
T.C.
CITY OF TEMECULA
PO#: 4501947487
PRISM#: 4864798
CHARTER
PUBLIC WORKS DEPARTMENT
#-C
#-A
#-D
_____ IN CONCRETE
_____ IN ASPHALT
_____ IN DIRT/GREENBELT
CALLOUT ABBREVIATIONS
TREN (TRENCH TO INSTALL 3" UG CONDUIT)
BORE (BORE TO INSTALL 3" UG CONDUIT)
BP (BORE PIT 3'x6')
MBP (MISSILE BORE PIT 2'x4')
PH (POTHOLE 2'x2')
V (CATV VAULT) | P (CATV PEDESTAL)
R&R (REMOVE & REPLACE)
##'
##-
CALLOUT DETAILS
XX-X
##'
CONSTRUCTION TOTALS
(TOTAL AMOUNTS FOR ENTIRE ROUTE)
JOB NOTES:
1. The existence and location of any
underground utility pipes or structures
was obtained by a search of the available
records and field conditions. Additional
underground facilities may exist, or the
location of the facilities may differ from
the locations shown on these plans. The
contractor shall, at his own expense,
determine the exact location of all such
underground facilities prior to
commencement of any work or any
action which may damage such facilities
or interfere with their continuous and
proper operation.
2. All plans must be checked and approved
by the governmental agency, or agencies,
having jurisdiction over the roadways
shown on this plan being put into effect.
All plans are intended to conform to the
Manual on Uniform Traffic Control
Devices. The customer/contractor is
responsible for ascertaining addition
agency requirements for work hours
allowed, noise abatement, and other
rules and regulations.
3. The temporary traffic controls must be
installed per the agency approved plan to
be effective. Field changes, other than
minor adjustment, must be authorized in
writing be a representative of the
governmental agency, or agencies,
having jurisdiction over the roadway.
4. Plan implementation and device
placement should be performed by
experienced and trained personnel.
5. Temporary traffic control must be
monitored and maintained by the
customer/contractor to remain effective.
Monitoring and maintenance frequency
is dictated by field conditions, but not
less than daily.
6. Optimum Inc. has no control over, or
responsibility for traffic control plan
implementation and inspections
performed by others. Users agree to
indemnify Optimum Inc. for claims
made regarding failure to install,
maintain or remove controls per
approved traffic control plans.
PRISM#: 4864798
·
·
·
·
·
·
N.T.S.
WORK DURATION:
·5 DAYS FOR EXCAVATION / BORE / TRENCH WORK
·1 DAY FOR RESTORATION
·1 DAY TO PULL CABLE
·7 DAYS OF TRAFFIC CONTROL SET UP
·TOTAL # OF WORK DAYS: 7
SCOPE OF WORK:
·BORE / TRENCH TO INSTALL CONDUITS FOR SPECTRUM (1,055').
·SET NEW CHARTER VAULTS (3).
·REMOVE & REPLACE ASPHALT (~120 sq.ft).
·REMOVE & REPLACE CONCRETE SIDEWALK PANEL (~208 sq.ft).
AREA MAP:
EXCAVATION AREA
1,055'
STANDARD NO 117:
–
➢
➢
➢
➢
➢
➢
➢
➢
UTILITY PLAN GENERAL NOTES:
PIPE AND WIRE TRENCHING:
JOB NOTES:
1. The existence and location of any
underground utility pipes or structures
was obtained by a search of the available
records and field conditions. Additional
underground facilities may exist, or the
location of the facilities may differ from
the locations shown on these plans. The
contractor shall, at his own expense,
determine the exact location of all such
underground facilities prior to
commencement of any work or any
action which may damage such facilities
or interfere with their continuous and
proper operation.
2. All plans must be checked and approved
by the governmental agency, or agencies,
having jurisdiction over the roadways
shown on this plan being put into effect.
All plans are intended to conform to the
Manual on Uniform Traffic Control
Devices. The customer/contractor is
responsible for ascertaining addition
agency requirements for work hours
allowed, noise abatement, and other
rules and regulations.
3. The temporary traffic controls must be
installed per the agency approved plan to
be effective. Field changes, other than
minor adjustment, must be authorized in
writing be a representative of the
governmental agency, or agencies,
having jurisdiction over the roadway.
4. Plan implementation and device
placement should be performed by
experienced and trained personnel.
5. Temporary traffic control must be
monitored and maintained by the
customer/contractor to remain effective.
Monitoring and maintenance frequency
is dictated by field conditions, but not
less than daily.
6. Optimum Inc. has no control over, or
responsibility for traffic control plan
implementation and inspections
performed by others. Users agree to
indemnify Optimum Inc. for claims
made regarding failure to install,
maintain or remove controls per
approved traffic control plans.
CLEARED BY
CITY OF TEMECULA
PUBLIC WORKS
david.pina 01/11/2024
01/11/2024 01/11/2024
01/11/20
ELECTRIC LINE GAS LINE
TELEPHONE LINE
WATER LINE
CATV LINE
TRAFFIC SIGNAL LINE
SEWER LINE
STORM DRAIN LINE
FIBER OPTIC LINE
PETROLUEM LINE
STREET LIGHTS
INDUSTRIAL WASTE
OIL LINE
FUEL LINE
RECLAIMED WATER
PROPOSED CONSTRUCTION
PROPOSED HDD BORE / CONDUIT INSTALLATION
PROPOSED TRENCH / CONDUIT INSTALLATION
PROPOSED POTHOLE (2'x2')
PROPOSED EXIT / MISSILE BORE PIT (2'x4')
PROPOSED BORE PIT (3'x6')
CATV PROPOSED NEW CATV VAULT (2'x3')
UTILITY / LINE LEGEND
EDGE OF PAVEMENT
CURB FACE
RIGHT OF WAY (CITY)
CENTERLINE (C/L)
N
DESIGN ORIENTATIONREVISIONS
REV#DATE DESCRIPTION
CONSTRUCTION
SHEET 2 OF 2
TP TELEPHONE PEDESTAL
T TELEPHONE VAULT
EV ELECTRIC VAULT
CATV VAULT
IV IRRIGATION VAULT
UTILITY POLE
FIRE HYDRANT
UNDERGROUND VALVE
MAN HOLE
F
M
SL STREET LIGHT VAULT
TS TRAFFIC SIGNAL VAULT
WV WATER VAULT
CATV PEDESTALABOVE GROUND VALVE
GV GAS VAULT
FO FIBER OPTIC VAULT
CV COMMUNICATIONS VAULT
T
EXISTING OBJECTS
S/W
D/W
PH
R/W
EX
C/L
EOP
CF
ABBREVIATIONS
V
PED
#-C
#-A
#-D
_____ IN CONCRETE
_____ IN ASPHALT
_____ IN DIRT/GREENBELT
CALLOUT ABBREVIATIONS
TREN (TRENCH TO INSTALL 3" UG CONDUIT)
BORE (BORE TO INSTALL 3" UG CONDUIT)
BP (BORE PIT 3'x6')
MBP (MISSILE BORE PIT 2'x4')
PH (POTHOLE 2'x2')
V (CATV VAULT) | P (CATV PEDESTAL)
R&R (REMOVE & REPLACE)
##'
##-
CALLOUT DETAILS
XX-X
##'
CONSTRUCTION TOTALS
(TOTAL AMOUNTS FOR ENTIRE ROUTE)
JOB NOTES:
1. The existence and location of any
underground utility pipes or structures
was obtained by a search of the available
records and field conditions. Additional
underground facilities may exist, or the
location of the facilities may differ from
the locations shown on these plans. The
contractor shall, at his own expense,
determine the exact location of all such
underground facilities prior to
commencement of any work or any
action which may damage such facilities
or interfere with their continuous and
proper operation.
2. All plans must be checked and approved
by the governmental agency, or agencies,
having jurisdiction over the roadways
shown on this plan being put into effect.
All plans are intended to conform to the
Manual on Uniform Traffic Control
Devices. The customer/contractor is
responsible for ascertaining addition
agency requirements for work hours
allowed, noise abatement, and other
rules and regulations.
3. The temporary traffic controls must be
installed per the agency approved plan to
be effective. Field changes, other than
minor adjustment, must be authorized in
writing be a representative of the
governmental agency, or agencies,
having jurisdiction over the roadway.
4. Plan implementation and device
placement should be performed by
experienced and trained personnel.
5. Temporary traffic control must be
monitored and maintained by the
customer/contractor to remain effective.
Monitoring and maintenance frequency
is dictated by field conditions, but not
less than daily.
6. Optimum Inc. has no control over, or
responsibility for traffic control plan
implementation and inspections
performed by others. Users agree to
indemnify Optimum Inc. for claims
made regarding failure to install,
maintain or remove controls per
approved traffic control plans.
PRISM#: 4864798
00 40'80'
PTIMUM, INC.
GENERAL ENGINEERING CONTRACTORS
OFFICE: (909) 990-0767
CSLB#: 817291 | CLASS: C-7 A C31
17890 VALLEY BLVD BLOOMINGTON CA
7337 CENTRAL AVE RIVERSIDE CA.92504
OFFICE: (833) 267-6097
44535 BEDFORD CT
TEMECULA, CA.
-
JESUS SAMANIEGO
HHS CONSTRUCTION
11-10-2023
PENDING
T.C.
CITY OF TEMECULA
PO#: 4501947487
PRISM#: 4864798
CHARTER
PUBLIC WORKS DEPARTMENT
CF
CF
CF
CF
CF
CF
CF
EO
P
EO
P
EO
P
EOP
EO
P
EO
P
EO
P
EO
P
EO
P
EO
P
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
EO
P
EO
P
EO
P
EO
P
EO
P
EO
P
EO
P
EO
P
EO
P
EOP
EOP
EOP
EO
P
EOP
EO
P
CF
CF
EO
P
EO
P
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
CF
PED
0+0
0
1+0
0
2+0
0
3+0
0
4+0
0
5+0
0
6+0
0
7+0
0
8+0
0
30'18'
12'
30'
18'
12'
CAT
V
CAT
V
CA
T
V
0+0
0
1+0
0
2+00
1+0
0
70'
12'
58'
52'
EDIS
O
N
EDIS
O
N
EDI
S
O
N
2'x3'P1-D
2'x4'MBP1-A
24 sq.ftR&R-A
2'x4'MBP2-C
72 sq.ftR&R-C
1 | 3"
55'
BORE
P1 TO MBP2
1 | 3"
40'
MBP2 TO
MBP3
TREN
2'x4'MBP3-C
36 sq.ftR&R-C
1 | 3"
290'
BORE
MBP3 TO V1
2'x3'
3'x6'
V1-C
50 sq.ft
BP1-C
R&R-C
1 | 3"
295'
V1 TO V2
BORE
2'x3'V2-C
50 sq.ftR&R-C
2'x4'MBP5-A
24 sq.ftR&R-A
2'x4'MBP6-A
32 sq.ftR&R-A
3'x6'BP2-A
40 sq.ftR&R-A 1 | 3"
290'
BORE
V2 TO BP3
2'x3'V3-D
1 | 3"
5'
BORE
V3 TO ROW
T
E
M
E
C
U
L
A
P
K
W
Y
L
A
P
A
Z
R
D
TE
M
E
C
U
L
A
P
K
W
Y
BEDF
O
R
D
C
T
70'
12'
58'
58'
2'x4'MBP4-C
2'x4'MBP7-D
3'x6'BP3-D
1 | 3"
85'
TREN
BP3 TO V3
N
DESIGN ORIENTATION
CITY OF
TEMECULA
PO#:
PRISM#:
PUBLIC WORKS DEPARTMENT
PUBLIC WORKS - TRAFFIC ENGINEERING DIVISION
CITY OF TEMECULAENGINEER'S INFORMATIONENGINEER'S SEAL
FOR
TRAFFIC CONTROL PLANS
CONTRACTOR:
RECOMMENDED BY:DATE:
ACCEPTED BY:DATE:
R.T.E. NO.
NICOLAS M. MINICILLI
TRAFFIC ENGINEER
Updated Traffic Control Notes to rev -AJP AJP 1/26/12
TRAFFIC CONTROL GENERAL NOTES (REV'D. 08/26/20):
1.ALL TRAFFIC CONTROL DEVICES SHALL CONFORM TO THE LATEST EDITION OF THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES
(CALIFORNIA MUTCD) AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION.
2.THE CITY ENGINEER OR HIS REPRESENTATIVE HAS THE AUTHORITY TO INITIATE FIELD CHANGES TO ASSURE PUBLIC SAFETY.
3.ALL TRAFFIC CONTROL DEVICES SHALL BE REMOVED FROM VIEW WHEN NOT IN USE.
4.WORK HOURS SHALL BE RESTRICTED TO THE PERIOD BETWEEN 8:30 A.M. AND 3:30 P.M., MONDAY THROUGH FRIDAY, UNLESS APPROVED
OTHERWISE. WHEN NIGHT WORK IS REQUIRED, WORK HOURS SHALL BE 9 P.M. TO 5 A.M., SUNDAY THROUGH THURSDAY.
5.TRENCHES MUST BE BACK FILLED OR PLATED DURING NON-WORKING HOURS. STEEL PLATES SHALL HAVE ASPHALTIC CONCRETE BERM ON ALL
EDGES. ALL DIRT, DUST, AND DEBRIS SHALL BE REMOVED FROM STREET AT END OF EACH DAY AND AT THE END OF THE JOB. THE STREET SHALL BE
IN DRIVABLE CONDITION AT ALL TIMES.
6.PEDESTRIAN CONTROLS SHALL BE PROVIDED AS SHOWN ON THE PLANS.
7.TEMPORARY "NO PARKING" SIGNS WILL BE POSTED 24 HOURS PRIOR TO COMMENCING WORK.
8.ACCESS TO DRIVEWAYS WILL BE MAINTAINED AT ALL TIMES UNLESS OTHER ARRANGEMENTS ARE MADE.
9.THE CONTRACTOR SHALL REPLACE WITHIN 72 HOURS, ALL TRAFFIC SIGNAL LOOP DETECTORS DAMAGED DURING CONSTRUCTION.
10.THE CONTRACTOR SHALL REPLACE WITHIN 24 HOURS, ALL STRIPING REMOVED OR DAMAGED BY CONSTRUCTION WORK. (STRIPING MAY BE
REPLACED TEMPORARILY WITH TAPE.)
11.ALL WORKERS SHALL BE EQUIPPED WITH AN ORANGE VEST (OR A REFLECTIVE VEST AT NIGHT). ALL FLAGGERS SHALL ALSO BE EQUIPPED WITH A
HARD HAT, C28 "STOP/SLOW" PADDLE AND SHALL BE TRAINED IN THE PROPER FUNDAMENTALS OF FLAGGING TRAFFIC.
12.ANY WORK THAT DISTURBS NORMAL TRAFFIC SIGNAL OPERATIONS SHALL BE COORDINATED WITH THE CITY OF TEMECULA'S TRAFFIC DIVISION, 48
HOURS PRIOR TO BEGINNING CONSTRUCTION. CONTACT THE CITY'S TRAFFIC DIVISION AT (951) 694 -6411.
13.THE CONTRACTOR SHALL MAINTAIN ALL TRAFFIC CONTROL DEVICES 24 HOURS PER DAY AND 7 DAYS PER WEEK.
14.A MINIMUM OF TWELVE (12) FOOT TRAVEL LANES MUST BE MAINTAINED UNLESS OTHERWISE APPROVED BY THE DEPARTMENT OF PUBLIC
WORKS.
15.ALL NIGHT WORK WILL REQUIRE WRITTEN APPROVAL FROM THE DEPARTMENT OF PUBLIC WORKS. LANE CLOSURES, ROAD DETOURS, ROAD
CLOSURES, AND TRAFFIC SIGNAL MODIFICATIONS ASSOCIATED WITH OVERNIGHT CONSTRUCTION ACTIVITIES WILL REQUIRE WARNING SIGNS BE
PLACED AT LEAST ONE WEEK IN ADVANCE OF STARTING CONSTRUCTION.
16.A SOLAR POWERED FLASHING ARROW BOARD SHALL BE REQUIRED ON ALL ARTERIAL STREET LANE CLOSURES.
17. IF THE PERMIT APPLICANT DETERMINES THAT CONDUIT INSTALLATION WILL BE BY THE BORING MACHINE METHOD, THE TRENCH PATCH FOR THE
UTILITY OBSERVATION EXCAVATION WILL BE THE SAME AS FOR OPEN TRENCH EXCAVATION METHOD. THIS WILL PROVIDE A SINGLE CONTINUOUS
SURFACE RESTORATION ELIMINATING THE MULTIPLE PENETRATION INTO THE PUBLIC ROADWAY TO ALL REQUIREMENTS IN CITY STANDARD
DRAWING # 407 (SHEET 1 AND 2) FOR TRENCH PATCH.
18. ANY WORK THAT CREATES AN UNDUE SAFETY RISK OR CREATES SEVERE CONGESTION MAY BE SHUT DOWN BY CITY TRAFFIC ENGINEERS, CITY FIELD
INSPECTION, OR THE POLICE DEPARTMENT.
19. CONES AND DELINEATORS SHALL HAVE REFLECTORIZED SLEEVES FOR NIGHT WORK.
20. IF PARKING IS ALLOWED IN ADVANCE WARNING AREA, ADVANCE WARNING SIGNS SHALL BE MOUNTED ON HIGH LEVEL DEVICES.
APPLICANT IS RESPONSIBLE FOR FULL AND COMPLETE REPRESENTATION OF THE ACTUAL ROAD CONDITIONS SHOWN ON THIS PLAN INCLUDING, BUT NOT
LIMITED TO EXISTING STRIPING, SIGNING, SIDEWALKS, AND BIKE LANES.
7337 CENTRAL AVE RIVERSIDE CA.92504
OFFICE: (833) 267-6097
CHARTER PTIMUM, INC.
GENERAL ENGINEERING CONTRACTORS
OFFICE: (909) 990-0767
CSLB#: 817291 | CLASS: C-7 A C31
17890 VALLEY BLVD BLOOMINGTON CA
1
4
HHS CONSTRUCTION
OFFICE: (909) 393-3322
CSLB#: 818906 | CLASS: A C31 C10 B C-7
2042 S GROVE AVE, ONTARIO, CA. 91761
UTILITY COMPANY:
EXISTING NO TURN LANE
TRAFFIC CONE
FLASHING ARROW SIGN (FAS)
EXISTING TURN ONLY LANE
BARRICADE
WORK ZONE
TRAFFIC SIGNAL
HIGH LEVEL WARNING DEVICE
(WITH CALTRANS & MUTCD CODE)
SIGN (WITH CALTRANS CODE)
TRAFFIC FLOW DIRECTION
FLAGGER
S
DETAIL SHEET LEGEND
CONE SPACING - 25' MAXIMUM
AT LEAST TWO DAYS
UG SERVICE ALERT OF SOUTHERN CALIFORNIA
BEFORE YOU DIG
DIGALERT
Call: TOLL FREE
1-800-227-2600
WORK HOURS
MONDAY - FRIDAY
8:30am - 3:30pm
-
SPECTRUM
TEMECULA PKWY
SERGIO GONZALEZ
PRISM#: 4864798
PROPOSED SIGNS
TEMECULA PERMIT #:LD23-7097
HHS CONSTRUCTION
PENDING
TYLER CUNARD
44535 BEDFORD CT
11-10-2023
4501947487
4864798
TEMECULA, CA.
AREA MAP:
EXCAVATION AREA
1,055'
TCP 1.1 AND 1.3
NARROW
LANE
C12(CA)
ROAD
AHEAD
W20-1
WORK END
ROAD WORK
G20-2
R4-7A
KEEP
RIGHT
W24-1L
TCP 1.2
OR
CLIP ON TYPE
CONE MOUNTED SIGNS
SUPPLEMENTAL ONLY
35 MPH OR LESS
AHEAD
W20-5
CLOSED
RIGHT
OR
CENTER
C20A(CA) C20B(CA)
NO. OF LANES
LEFT LANE
INTERCHANGEABLE WITH
C20(CA)
W1-4L W1-FR
W12-2
LANE
CLOSED
C30(CA)
R3-2 R3-1
RIGHT LANE
MUST
TURN RIGHT
R3-7R
W4-2R
ROAD
AHEAD
W20-1
WORK
END
ROAD WORK
G20-2
W6-3
WORK DURATION:
·5 DAYS FOR EXCAVATION / BORE / TRENCH WORK
·1 DAY FOR RESTORATION
·1 DAY TO PULL CABLE
·7 DAYS OF TRAFFIC CONTROL SET UP
·TOTAL # OF WORK DAYS: 7
SCOPE OF WORK:
·BORE / TRENCH TO INSTALL CONDUITS FOR SPECTRUM (1,055').
·SET NEW CHARTER VAULTS (3).
·REMOVE & REPLACE ASPHALT (~120 sq.ft).
·REMOVE & REPLACE CONCRETE SIDEWALK PANEL (~208 sq.ft).
2647
CALTRANS PERMIT #:08-23-6-UE-1014
1/18/2024 awa7988
01/29/24
01/31/24
DESIGN ORIENTATION
PROPOSED TCP 1
CITY OF
TEMECULA
PO#:
PRISM#:
PUBLIC WORKS DEPARTMENT
PUBLIC WORKS - TRAFFIC ENGINEERING DIVISION
CITY OF TEMECULAENGINEER'S INFORMATIONENGINEER'S SEAL
FOR
TRAFFIC CONTROL PLANS
CONTRACTOR:
RECOMMENDED BY:DATE:
ACCEPTED BY:DATE:
R.T.E. NO.
NICOLAS M. MINICILLI
TRAFFIC ENGINEER
Updated Traffic Control Notes to rev -AJP AJP 1/26/12
7337 CENTRAL AVE RIVERSIDE CA.92504
OFFICE: (833) 267-6097
CHARTER PTIMUM, INC.
GENERAL ENGINEERING CONTRACTORS
OFFICE: (909) 990-0767
CSLB#: 817291 | CLASS: C-7 A C31
17890 VALLEY BLVD BLOOMINGTON CA
2
4
UTILITY COMPANY:
N.T.S.
AT LEAST TWO DAYS
UG SERVICE ALERT OF SOUTHERN CALIFORNIA
BEFORE YOU DIG
DIGALERT
Call: TOLL FREE
1-800-227-2600
-
SPECTRUM
TEMECULA PKWY
HHS CONSTRUCTION
OFFICE: (909) 393-3322
CSLB#: 818906 | CLASS: A C31 C10 B C-7
2042 S GROVE AVE, ONTARIO, CA. 91761
PRISM#: 4864798
4501914797
4928351
N
PROPOSED SIGNS
SERGIO GONZALEZ
HHS CONSTRUCTION
PENDING
TYLER CUNARD
44535 BEDFORD CT
11-10-2023
TEMECULA, CA.
NARROW
LANE
C12(CA)
ROAD
AHEAD
W20-1
WORK END
ROAD WORK
G20-2
R4-7A
KEEP
RIGHT
W24-1L
100'
SIGN
SPACING
65'
SHIFTING
TAPER
DOWN
STREAM
TAPER
50' MIN./
100' MAX
CURB OR E.P.
CURB OR E.P.
100'
SIGN
SPACING
65'
SHIFTING
TAPER
160'
BUFFER
10'
LANE 12'
LANE 12'
100'
SIGN
SPACING
100'
SIGN
SPACING
85'
WORK ZONE
100'
SIGN
SPACING
100'
SIGN
SPACING
STREET 36'
2647
WORK HOURS
MONDAY - FRIDAY
8:30am - 3:30pm
TEMECULA PERMIT #:LD23-7097
CALTRANS PERMIT #:08-23-6-UE-1014
1/18/2024 awa7988
01/29/24
01/31/24
OR
CLIP ON TYPE
CONE MOUNTED SIGNS
SUPPLEMENTAL ONLY
35 MPH OR LESS
AHEAD
W20-5
CLOSED
RIGHT
OR
CENTER
C20A(CA) C20B(CA)
NO. OF LANES
LEFT LANE
INTERCHANGEABLE WITH
C20(CA)
W1-4L W1-FR
W12-2
LANE
CLOSED
C30(CA)
R3-2 R3-1
RIGHT LANE
MUST
TURN RIGHT
R3-7R
W4-2R
ROAD
AHEAD
W20-1
WORK
END
ROAD WORK
G20-2
W6-3
DESIGN ORIENTATION
PROPOSED TCP 2
CITY OF
TEMECULA
PO#:
PRISM#:
PUBLIC WORKS DEPARTMENT
PUBLIC WORKS - TRAFFIC ENGINEERING DIVISION
CITY OF TEMECULAENGINEER'S INFORMATIONENGINEER'S SEAL
FOR
TRAFFIC CONTROL PLANS
CONTRACTOR:
RECOMMENDED BY:DATE:
ACCEPTED BY:DATE:
R.T.E. NO.
NICOLAS M. MINICILLI
TRAFFIC ENGINEER
Updated Traffic Control Notes to rev -AJP AJP 1/26/12
7337 CENTRAL AVE RIVERSIDE CA.92504
OFFICE: (833) 267-6097
CHARTER PTIMUM, INC.
GENERAL ENGINEERING CONTRACTORS
OFFICE: (909) 990-0767
CSLB#: 817291 | CLASS: C-7 A C31
17890 VALLEY BLVD BLOOMINGTON CA
3
4
UTILITY COMPANY:
N.T.S.
AT LEAST TWO DAYS
UG SERVICE ALERT OF SOUTHERN CALIFORNIA
BEFORE YOU DIG
DIGALERT
Call: TOLL FREE
1-800-227-2600
-
WORK HOURS
SUNDAY - THURSDAY
9:00pm - 5:00am
(NIGHT WORK REQUIRED FOR THIS PHASE)
SPECTRUM
TEMECULA PKWY
HHS CONSTRUCTION
OFFICE: (909) 393-3322
CSLB#: 818906 | CLASS: A C31 C10 B C-7
2042 S GROVE AVE, ONTARIO, CA. 91761
PRISM#: 4864798
4501914797
4928351
N
PROPOSED SIGNS
SERGIO GONZALEZ
HHS CONSTRUCTION
PENDING
TYLER CUNARD
44535 BEDFORD CT
11-10-2023
TEMECULA, CA.
2647
350'
SIGN
SPACING
C3
0
A
(
C
A
)
C1
2
(
C
A
)
W2
0
-
1
G2
0
-
2
R3
-
1
G20-2
W20-1
R3-1
C30(CA)W12-1W1-6L
R3-7RW20-1 C20-R W4-2R
600'
MERGING
TAPER
350'
SIGN
SPACING
350'
SIGN
SPACING
350'
SIGN
SPACING
G20-2
W2
0
-
1
G2
0
-
2
FA
S
W12-1
10' MIN.
10' MIN.
8' MIN.
C3
0
(
C
A
)
100'
GAP
DOWN
STREAM
TAPER
50' MIN./
100' MAX
125'
MERGING
TAPER
350'
SIGN
SPACING
350'
SIGN
SPACING
350'
SIGN
SPACING
S
12' MIN12' MIN
R3-4
CALTRANS ROW
TRAFFIC CONTROL SETUP
TO BE PERFORMED UNDER
CALTRANS PERMIT # 08-23-6-UE-1014 CALTRANS
MAINTAINED
SIGNAL
630'
WORK AREA
SHOULDER
C30A(CA)
CLOSED
NARROW
LANE
C12(CA)
TEMECULA PERMIT #:LD23-7097
CALTRANS PERMIT #:08-23-6-UE-1014
1/18/2024 awa7988
01/29/24
01/31/24
DESIGN ORIENTATION
PROPOSED TCP 3
CITY OF
TEMECULA
PO#:
PRISM#:
PUBLIC WORKS DEPARTMENT
PUBLIC WORKS - TRAFFIC ENGINEERING DIVISION
CITY OF TEMECULAENGINEER'S INFORMATIONENGINEER'S SEAL
FOR
TRAFFIC CONTROL PLANS
CONTRACTOR:
RECOMMENDED BY:DATE:
ACCEPTED BY:DATE:
R.T.E. NO.
NICOLAS M. MINICILLI
TRAFFIC ENGINEER
Updated Traffic Control Notes to rev -AJP AJP 1/26/12
7337 CENTRAL AVE RIVERSIDE CA.92504
OFFICE: (833) 267-6097
CHARTER PTIMUM, INC.
GENERAL ENGINEERING CONTRACTORS
OFFICE: (909) 990-0767
CSLB#: 817291 | CLASS: C-7 A C31
17890 VALLEY BLVD BLOOMINGTON CA
4
4
UTILITY COMPANY:
N.T.S.
AT LEAST TWO DAYS
UG SERVICE ALERT OF SOUTHERN CALIFORNIA
BEFORE YOU DIG
DIGALERT
Call: TOLL FREE
1-800-227-2600
-
SPECTRUM
TEMECULA PKWY
HHS CONSTRUCTION
OFFICE: (909) 393-3322
CSLB#: 818906 | CLASS: A C31 C10 B C-7
2042 S GROVE AVE, ONTARIO, CA. 91761
PRISM#: 4864798
4501914797
4928351
N
PROPOSED SIGNS
SERGIO GONZALEZ
HHS CONSTRUCTION
PENDING
TYLER CUNARD
44535 BEDFORD CT
11-10-2023
TEMECULA, CA.
NARROW
LANE
C12(CA)
ROAD
AHEAD
W20-1
WORK END
ROAD WORK
G20-2
R4-7A
KEEP
RIGHT
W24-1L
100'
SIGN
SPACING
65'
SHIFTING
TAPER
DOWN
STREAM
TAPER
50' MIN./
100' MAX
CURB OR E.P.
CURB OR E.P.
100'
SIGN
SPACING
65'
SHIFTING
TAPER
160'
BUFFER
10'
LANE 12'
LANE 12'
100'
SIGN
SPACING
100'
SIGN
SPACING
25'
WORK ZONE
100'
SIGN
SPACING
100'
SIGN
SPACING
STREET 36'
2647
WORK HOURS
MONDAY - FRIDAY
8:30am - 3:30pm
TEMECULA PERMIT #:LD23-7097
CALTRANS PERMIT #:08-23-6-UE-1014
1/18/2024 awa7988
01/29/24
01/31/24