HomeMy WebLinkAboutLD23-7486Permit Number: LD23-7486
LD - Utilities/ Utility Maintenance
Issued: 12/11/2023
Expired: 06/12/2024
Job Address: 45735 Clubhouse Dr
Legal Description: Tract Map 13060-4:33
City of Temecula - Land Development Division
41000 Main Street - Temecula, CA 92590
Mailing Address: P.O. Box 9033 Temecula, CA 92589-9033
Phone: (951) 308-6395 Fax: (951) 694-6475
Southern California Edison
298 Kansas Street
Redlands, CA 92373
(909) 307-6884
Applicant:
Ferreira Construction Co., Inc.
10370 Commerce Center Drive, B-200
Rancho Cucamonga, CA 91730
(909) 606-5900
Contractor:
Utility Work Order Number: 904301882-200
Description:
SCE 904301882-200
WORK HOURS SHALL BE MONDAY – FRIDAY, NO HOLIDAYS, 8:30am - 3:30pm
Proposed work:
Conduit installation and restoration
Permitee Date
City Engineer or Authorized Representative Date
12/11/2023
Page 1 of 1
Bad run in 350 DB secondaries needs to be replaced. Cust at 45735 clubhouse dr is cut to 120v at
panel with cut over can. Bad run of cable is from HH in front of 45644 masters drive around to corner
to HH in green belt across from 45735 clubhouse drive. Bars in both HH needs to be replaced 4 ways
bars at both locations. Replace HH in the front yard of 45735 clubhouse. Cable is in CIC
Distribution Repair Order
Information:CAD ID: GO 120323-00222 Incident Date:12//03//2023 Time:17:18
Reported by:Wallencheck, Nicholas Radio No:9492 Cell Number:(951) 2288193
Structure No:5316189 RO Date:12//03//2023 Time:17:18
Problem:Part Lights Cause:Damaged/Broken UG Secondary
Circuit:BALLOON Code 01051 Sub:MORAGA
Location:45735 CLUBHOUSE DR, TEMECULA
Access:Street
Seq No:4199193 Foreman:Radio No:Cell Number:
Duration:8 Crew Size:4 Crews Needed:1 Crew Type:DISTRIBUTION
Enviromental Release?No Enviromental Other?No District Notified?No-
Tree Crew Needed?No Grounding Needed for Tree Crew?No
Load Off (Individual or Downstream):
cut to 120v
Other Departments:
TeleComm Transmission Other Utility Other
Equipment Needed:
Double/Tub Bucket Arrowboard Flatbed EasyHauler
Y2K Ped Control Snow Cat Fork Lift
Auger Truck P/L Dolly Air Ops Power Dolly
X UG Van P/L Pole Dolly Four Wheel Drive Crane
Material:
160 ft-2-350 and 1-4/0 CLP Cable Material Code - _________________
Remarks:(Status of Line, Access Instructions, Special Instructions)
# of Attachments-2
Pg 1 of 3 Seq #- 4199193
D: 88 / SH
RCCD: 12/22/23
AGMT: C-3315/ TS
WO #: 904301882
UCC #: 904301882-200/ TS
1
Michelle Y Ramirez
From:Bronte Cummings <Bronte.Cummings@swca.com>
Sent:Monday, December 4, 2023 5:58 AM
To:Lann Benham
Cc:SCE Emergency
Subject:904301882 Temecula Clubhouse Drive Trenching 5316189
Hi Lann,
Thanks for alerting us to the emergency trenching for damaged underground cable at structure 5316189, 45735
Clubhouse Drive, Temecula.
We have reviewed for bio, waters, and cultural resources concerns. You are approved to proceed with the following
standard environmental requirements:
Tailboard Briefing: The Environmental Requirements must be kept on site and be read to the crew prior to starting
work. If any of the requirements create a safety or scope concern, please contact Environmental Services. If additional
ground disturbing or vegetation clearing activities are proposed during project activities, stop work and contact
Environmental Services.
Scope of Work Authorization: The following ERD conditions apply to the work outlined in the Scope of Work provided to
ESD. Any changes or additions, including but not limited to construction means and methods, equipment identified,
materials used, extent of grading, scope of vegetation impacting activities, add‐ons, or proposed access routes, must be
reviewed and released by SCE Environmental prior to the start of work.
Minimize work area: The work area shall be minimized to the smallest area necessary to complete the work.
Crew Check: Prior to starting work, crews will check the workspace for bird nests (e.g., pole cavities, vegetation to be
removed). Contact the biological monitor or call the number above prior to work within 200 feet of an active nest.
Cavity Nests: Prior to starting work, crews will check the workspace for cavities in poles and trees. Crews will tap loudly
on poles and trees with potential cavity nests and watch for wildlife leaving the cavity or the sounds of young birds
inside the cavity. If an active cavity nest is suspected, crew must STOP WORK and contact SCE Environmental Services
prior to work.
Injured/Trapped Wildlife: Prior to the start of work, crews will inspect their workspace for any injured or dead
wildlife. In addition, look in holes and trenches, construction material, and equipment for any trapped wildlife. Call the
number above if you observed dead, injured, or trapped wildlife.
Spill Release/Prevention: Vehicles/equipment must be inspected for leaks (e.g., fuel, oil, hydraulic fluids, etc.) and
repaired prior to work. Storing, fueling, and maintenance should not occur near a wetland, waterway, or riparian area.
Spill kits/absorbent clean‐up materials shall be available on‐site and if used, disposed of properly. Contact 1‐844‐GOT‐
SPIL for any potential hazardous material or spills that cannot be cleaned up by spill kits alone.
Avoid Waters and Wetlands: No work is allowed within waters or riparian vegetation unless reviewed and released by
SCE Environmental and all necessary permits have been issued. If unanticipated wetlands, waters, and riparian
vegetation are encountered STOP WORK and contact SCE Environmental.
2
Driving on road through waters (wet or dry): Only rubber wheeled vehicles and equipment are allowed to travel
through drivable water crossings on existing access roads. No grading or road improvements/repairs/alterations
(e.g., damming, diversions, fill, placement of plates or boards, etc.) are allowed within these areas unless reviewed and
released by SCE Environmental. No stopping within flowing or standing water.
Unanticipated groundwater: If unanticipated groundwater is encountered, STOP WORK and contact SCE
Environmental.
Archaeological/Human Remains/Paleontological Discoveries: If Archaeological resources (Native American or historical
artifacts), fossils, or human remains are encountered, stop work, and call the number above or the SCE Operator 626‐
302‐1212 and ask for an on‐call Archaeologist.
Site re‐contouring: Upon project completion, all disturbed areas must be returned to meet pre‐existing contours (i.e.,
original line and grade).
Weed Maintenance and Prevention: Use certified weed‐free materials (e.g., gravel, straw, and fill) to the extent
practicable. Maintain facilities and infrastructure to limit the introduction and spread of weeds.
Dust Control: No visible dust plumes are allowed. If dust plumes are observed, then slow speeds on dirt roads, water
dirt/work areas, or work when the soil is not extremely dry.
Generator Usage: Generators are not allowed unless a Generator Ordering Form (GOF) has been completed 20 days
prior to work. Contact Transportation Services Department (951) 440‐8370 to verify if a form has been received; if no
form has been submitted, contact the SCE representative to complete this form immediately.
Please let me know if you have any questions,
Brontë Cummings | she, her, hers
Assistant Staff Archaeologist – Cultural Resources
SWCA Environmental Consultants
320 N. Halstead Street, Suite 120
Pasadena, CA 91107
T 626.988.9687
1
Michelle Y Ramirez
From:Workflow System <WF-BATCH@SCE.COM>
Sent:Sunday, December 3, 2023 6:28 PM
To:Nicholas Wallencheck
Cc:GMC_RepairOrderSE; Field Tool Support; 88RepairOrder Group List
Subject:D88*99193*000904301882-0010*EMERGENT
EMERGENT Work Order ‐000904301882‐0010 has been generated successfully.
District 88
RO 99193
GO GO 120323‐00222
Problem Statement REPLC DAMAGE SEC CBL/CND BURD
Capital Yes
CONFID ENTIAL: CRITICAL EN ERGY INFRAST RUCTURE IN FORMATION (CEII)This information is class ified as CEII a s defined in 18 Code of Federal Regulatio ns se ctio n 388.113(c)(1), should be trea te d as suc h, a nd sho uld not be supplied to third -pa rty/non-SC E entities withou t the re quired authorization/ap pro val in adva nce pe r SCE-OPS-CEII-PL-451. Th e information is inten ded to be us ed for re fe ren ce only as it is not a legal re prese ntation o f re al property. This information may no t be electron ic ally or phy sically copie d or distrib uted without the ex press written pe rmiss ion o f Southern C alifornia Edison .
Remin der to contact “Dig Alert” a t 811 p rior to site excavation.
P r i n t e d : 1 2 -0 4 -2 0 2 3 0 60 12030 Feet1:709
9 0 4 3 0 1 8 8 2 -B a d c a b l e
SCEGeoVi ew
322
3
2
2
322
32
2
32
2
32
2
32
2
32
2
32
2
32
2
32
2
32
2
RAR
1061
PS
1807
PS
9958
PS
7641
PS
9399
PS
1773
PS
9516
PS
7068
B A
BA
0154128
900
4552216E
A
FI00206
FI77656
P
A
L
A
R
D
MU
R
F
I
E
L
D
D
R
S5492397
X5456379
J379A
GATE CODE
#7863
X5171354
RAINBOW CANYON
GOLF COURSE
B5006231
CLUBHOUSE
X5504780
BOTTOM OF
FUSE CLIPS
CAUTION:
HOT
U.G. SOURCE
KRTM RADIO
X5747881
P5747877
P5747886
JBARS
X5739819
JBARS
P5739816
4552221E
232
8
3
8
1
E
V5492396
X5732318
B5171363
BS0459
4490277E
2199571E
B5171358
4771185E
2309319E
B5306331
BS0747
LOAD BREAK
ADAPTABLE
2339766E
2339766E
P5362955
X5367651
P5367756 4697134E
PME7268
JBAR
LOAD BREAK
P5732319
JBAR
4938132E
2270155E
LOAD BREAK
2351927E
2351926EX5171362
P5456380
P5435548P5507962
X5507961
P5451167
X5390735
B5316519
2351929E
B5316185
B5306338 2351927E
B5316183
BS0869
ADAPTABLE
2351928E
B5316184
BS0870
B5306337
P5451169
P5747873
P5747872
JBARS
P5747870
P5747868
P5747864
P5456378
P5451168
P5747871
X5747869
P5747867
P5747866
P5747865
P5451166
P5451165
LBFC2872
X5747863
JBARS
P5747861
P5747860
P5739818
2351935E
S5316517
B5316518
P5747887
X5747862
X5739817
JBARS
B5313100
BS0996
BS0997
BS0998
B5313099
B5307519
B5344001
4304922EB5307520
B5316186
B5316187
B5306336
B5316520
B5316521
X5315998
B5316522
X5316523
B5316524
B5316525
B5316188
B5316189
B5316229
P5362956
1853931E
LOAD
BREAK
FD07069
4212302E
CL65A
P5428742
B5306332
B5171357 B5171361
X5171360
B5171359
B5171355
B5306335
B5306334
BS0871
1824645E
B5171356
B5306333
B5321326
1853930E
B5321327
B5316226
B5316230
B5316231
B5316227
B5316232
B5316228
B5321328
B5321329
P5006228
4528016E
LOAD BREAK
4207225E
X5315934
X5006162
B5006161
P5504905
P5504908
4317065E
2207162E
FD09501
30A 1885590E
BF09502
4061651E
2266585E
BS0019
4061657E
P5344026
B5315682
B5315681
B5315685
B5321330
B5307522
B5321516
B5321331
X5307523
B5307521
B5307524
B5344005
B5344003
B5344004
100A/5.8A-FC
B5315683B5344002
B5315684
3
3
6
A
336
A
33
6
A
3
3
6
A
3
3
6
A
1/
0
A
T
W
1/0 AT
W
1
/
0
A
T
W
1
/
0
A
1/0
A
T
W
1/0 A
4 A
1
/
0
A
T
W
1/
0
A
T
W
1/0
A
T
W
1/
0
A
T
W
1/0
A
T
W
1/0
A
T
W
CØ
CØ
BØ
BØ
AØ
10
0
0
J
C
N
10
0
0
J
C
N
1/0
J
C
N
AØ 1000 JCN
1/0
J
C
N
B
Ø
C
Ø
BØ
2
C
L
P
2
C
L
P
CØ
BØ
CØ
BØ
CØ
CØ
CØ
BØ
BØ
BØ
AØ
AØ
AØ
C
Ø
BCØ
AØ
C
Ø
B
Ø
C
Ø
BØ
CØ
BØ
BØ
CØ
CØ
BØ
BØ
BØ
CØ
CØ
CØ
AØ
BØ
A
Ø
BC
ØAØ
AØ
AØ
AØ
BC
Ø
BØ
CØ
BØ
AØ
AØ
AØ
AØ
CØ
C
Ø
BØ
BØ
2
C
L
P
2
C
L
P
C
Ø
B
Ø
CØ
CØ
BØ
B
Ø
BØ
B
Ø
BØ
CØ
P
E
C
H
A
N
G
A
P
K
W
Y
JE
D
E
D
I
A
H
S
M
I
T
H
R
D
P
A
L
A
R
D
T
R
O
T
S
D
A
L
E
D
R
MA
S
T
E
R
S
D
R
TO
U
R
N
A
M
E
N
T
RE
I
N
C
T
CANTERFIELD DR
P
E
C
H
A
N
G
A
P
K
W
Y
MU
R
F
I
E
L
D
D
R
G
R
E
E
N
S
B
O
R
O
TO
U
R
N
A
M
E
N
T
L
N
GL
E
N
E
A
G
L
E
S
C
L
A
S
S
I
C
W
Y
G
R
E
E
N
S
B
O
R
O
D
R
C
L
U
B
H
O
U
S
E
D
R
CLUBHO
U
S
E
D
R
MA
S
T
E
R
S
D
R
CR
E
E
K
S
I
D
E
W
Y
RA
I
N
B
O
W
C
A
N
Y
O
N
R
D
PU
T
T
I
N
G
G
R
E
E
N
C
T
BIRDIE
TO
U
R
N
A
M
E
N
T
CL
U
B
H
O
U
S
E
SI
L
V
E
R
A
D
O
L
N
SILVERADO
BAYHILL DR
WAILEA CT
BRIDGEVIE
W
C
I
R
CL
U
B
H
O
U
S
E
D
R
OLYMPIC
W
Y
OPE
N
C
T
GRE
E
N
W
A
Y
C
I
R
RA
I
N
B
O
W
C
A
N
Y
O
N
R
D
T
E
M
E
C
U
L
A
V
A
L
L
E
Y
F
R
W
Y
TE
M
E
C
U
L
A
V
A
L
L
E
Y
F
R
W
Y
TE
M
E
C
U
L
A
V
A
L
L
E
Y
F
R
W
Y
E
S
M
E
R
A
D
O
C
T
PALMETTO
PA
L
M
E
T
T
O
BAR
D
M
O
R
E
D
R
ESM
E
R
A
D
O
CL
A
S
S
I
C
W
Y
CALVA
D
O
DORAL
PRIORITY NOTIFICATION :
FAULT INDICATORS ON
LOOP STATIONS :
AUTOMATIC SW. GEAR (SCADA):
NETCOMM EQUIPMENT :
FOREMEN DATE
C2
BALLOON 12KV
MORAGA SUB (A1)
CODE: 01051
CODE: 8348SCALE: 400
BUNGENSTOCK
STURGEON
WILDOMAR 88
12/20/2022
02/06/2023
SYSTEM: VALLEY
NO
NO
NO
B2B1 B3
D3D2D3
B3B1
C3
B2
C3D2CONFIDENTIAL: CRITICAL ENERGY INFRASTRUCTURE INFORMATION (CEII) AS DEFINED IN SCE-OPS-RM-ST-451
Pg 2 of 3 Seq #- 4199193
Pg 3 of 3 Seq #- 4199193