HomeMy WebLinkAboutLD23-7486Permit Number: LD23-7486 LD - Utilities/ Utility Maintenance Issued: 12/11/2023 Expired: 06/12/2024 Job Address: 45735 Clubhouse Dr Legal Description: Tract Map 13060-4:33 City of Temecula - Land Development Division 41000 Main Street - Temecula, CA 92590 Mailing Address: P.O. Box 9033 Temecula, CA 92589-9033 Phone: (951) 308-6395 Fax: (951) 694-6475 Southern California Edison 298 Kansas Street Redlands, CA 92373 (909) 307-6884 Applicant: Ferreira Construction Co., Inc. 10370 Commerce Center Drive, B-200 Rancho Cucamonga, CA 91730 (909) 606-5900 Contractor: Utility Work Order Number: 904301882-200 Description: SCE 904301882-200 WORK HOURS SHALL BE MONDAY – FRIDAY, NO HOLIDAYS, 8:30am - 3:30pm Proposed work: Conduit installation and restoration Permitee Date City Engineer or Authorized Representative Date 12/11/2023 Page 1 of 1 Bad run in 350 DB secondaries needs to be replaced. Cust at 45735 clubhouse dr is cut to 120v at panel with cut over can. Bad run of cable is from HH in front of 45644 masters drive around to corner to HH in green belt across from 45735 clubhouse drive. Bars in both HH needs to be replaced 4 ways bars at both locations. Replace HH in the front yard of 45735 clubhouse. Cable is in CIC Distribution Repair Order Information:CAD ID: GO 120323-00222 Incident Date:12//03//2023 Time:17:18 Reported by:Wallencheck, Nicholas Radio No:9492 Cell Number:(951) 2288193 Structure No:5316189 RO Date:12//03//2023 Time:17:18 Problem:Part Lights Cause:Damaged/Broken UG Secondary Circuit:BALLOON Code 01051 Sub:MORAGA Location:45735 CLUBHOUSE DR, TEMECULA Access:Street Seq No:4199193 Foreman:Radio No:Cell Number: Duration:8 Crew Size:4 Crews Needed:1 Crew Type:DISTRIBUTION Enviromental Release?No Enviromental Other?No District Notified?No- Tree Crew Needed?No Grounding Needed for Tree Crew?No Load Off (Individual or Downstream): cut to 120v Other Departments: TeleComm Transmission Other Utility Other Equipment Needed: Double/Tub Bucket Arrowboard Flatbed EasyHauler Y2K Ped Control Snow Cat Fork Lift Auger Truck P/L Dolly Air Ops Power Dolly X UG Van P/L Pole Dolly Four Wheel Drive Crane Material: 160 ft-2-350 and 1-4/0 CLP Cable Material Code - _________________ Remarks:(Status of Line, Access Instructions, Special Instructions) # of Attachments-2 Pg 1 of 3 Seq #- 4199193 D: 88 / SH RCCD: 12/22/23 AGMT: C-3315/ TS WO #: 904301882 UCC #: 904301882-200/ TS 1 Michelle Y Ramirez From:Bronte Cummings <Bronte.Cummings@swca.com> Sent:Monday, December 4, 2023 5:58 AM To:Lann Benham Cc:SCE Emergency Subject:904301882 Temecula Clubhouse Drive Trenching 5316189 Hi Lann,    Thanks for alerting us to the emergency trenching for damaged underground cable at structure 5316189, 45735  Clubhouse Drive, Temecula.    We have reviewed for bio, waters, and cultural resources concerns. You are approved to proceed with the following  standard environmental requirements:    Tailboard Briefing: The Environmental Requirements must be kept on site and be read to the crew prior to starting  work.  If any of the requirements create a safety or scope concern, please contact Environmental Services. If additional  ground disturbing or vegetation clearing activities are proposed during project activities, stop work and contact  Environmental Services.      Scope of Work Authorization: The following ERD conditions apply to the work outlined in the Scope of Work provided to  ESD. Any changes or additions, including but not limited to construction means and methods, equipment identified,  materials used, extent of grading, scope of vegetation impacting activities, add‐ons, or proposed access routes, must be  reviewed and released by SCE Environmental prior to the start of work.       Minimize work area: The work area shall be minimized to the smallest area necessary to complete the work.       Crew Check: Prior to starting work, crews will check the workspace for bird nests (e.g., pole cavities, vegetation to be  removed).  Contact the biological monitor or call the number above prior to work within 200 feet of an active nest.     Cavity Nests: Prior to starting work, crews will check the workspace for cavities in poles and trees. Crews will tap loudly  on poles and trees with potential cavity nests and watch for wildlife leaving the cavity or the sounds of young birds  inside the cavity. If an active cavity nest is suspected, crew must STOP WORK and contact SCE Environmental Services  prior to work.    Injured/Trapped Wildlife:  Prior to the start of work, crews will inspect their workspace for any injured or dead  wildlife.  In addition, look in holes and trenches, construction material, and equipment for any trapped wildlife. Call the  number above if you observed dead, injured, or trapped wildlife.        Spill Release/Prevention:  Vehicles/equipment must be inspected for leaks (e.g., fuel, oil, hydraulic fluids, etc.) and  repaired prior to work.  Storing, fueling, and maintenance should not occur near a wetland, waterway, or riparian area.  Spill kits/absorbent clean‐up materials shall be available on‐site and if used, disposed of properly. Contact 1‐844‐GOT‐ SPIL for any potential hazardous material or spills that cannot be cleaned up by spill kits alone.      Avoid Waters and Wetlands: No work is allowed within waters or riparian vegetation unless reviewed and released by  SCE Environmental and all necessary permits have been issued. If unanticipated wetlands, waters, and riparian  vegetation are encountered STOP WORK and contact SCE Environmental.       2 Driving on road through waters (wet or dry): Only rubber wheeled vehicles and equipment are allowed to travel  through drivable water crossings on existing access roads. No grading or road improvements/repairs/alterations  (e.g., damming, diversions, fill, placement of plates or boards, etc.) are allowed within these areas unless reviewed and  released by SCE Environmental. No stopping within flowing or standing water.       Unanticipated groundwater: If unanticipated groundwater is encountered, STOP WORK and contact SCE  Environmental.       Archaeological/Human Remains/Paleontological Discoveries:  If Archaeological resources (Native American or historical  artifacts), fossils, or human remains are encountered, stop work, and call the number above or the SCE Operator 626‐ 302‐1212 and ask for an on‐call Archaeologist.      Site re‐contouring: Upon project completion, all disturbed areas must be returned to meet pre‐existing contours (i.e.,  original line and grade).      Weed Maintenance and Prevention: Use certified weed‐free materials (e.g., gravel, straw, and fill) to the extent  practicable. Maintain facilities and infrastructure to limit the introduction and spread of weeds.     Dust Control:  No visible dust plumes are allowed.  If dust plumes are observed, then slow speeds on dirt roads, water  dirt/work areas, or work when the soil is not extremely dry.      Generator Usage:  Generators are not allowed unless a Generator Ordering Form (GOF) has been completed 20 days  prior to work.  Contact Transportation Services Department (951) 440‐8370 to verify if a form has been received; if no  form has been submitted, contact the SCE representative to complete this form immediately.    Please let me know if you have any questions,    Brontë Cummings | she, her, hers  Assistant Staff Archaeologist – Cultural Resources    SWCA Environmental Consultants  320 N. Halstead Street, Suite 120   Pasadena, CA 91107  T 626.988.9687         1 Michelle Y Ramirez From:Workflow System <WF-BATCH@SCE.COM> Sent:Sunday, December 3, 2023 6:28 PM To:Nicholas Wallencheck Cc:GMC_RepairOrderSE; Field Tool Support; 88RepairOrder Group List Subject:D88*99193*000904301882-0010*EMERGENT EMERGENT Work Order ‐000904301882‐0010 has been generated successfully.  District   88  RO   99193  GO   GO 120323‐00222  Problem Statement REPLC DAMAGE SEC CBL/CND BURD Capital  Yes    CONFID ENTIAL: CRITICAL EN ERGY INFRAST RUCTURE IN FORMATION (CEII)This information is class ified as CEII a s defined in 18 Code of Federal Regulatio ns se ctio n 388.113(c)(1), should be trea te d as suc h, a nd sho uld not be supplied to third -pa rty/non-SC E entities withou t the re quired authorization/ap pro val in adva nce pe r SCE-OPS-CEII-PL-451. Th e information is inten ded to be us ed for re fe ren ce only as it is not a legal re prese ntation o f re al property. This information may no t be electron ic ally or phy sically copie d or distrib uted without the ex press written pe rmiss ion o f Southern C alifornia Edison . Remin der to contact “Dig Alert” a t 811 p rior to site excavation. P r i n t e d : 1 2 -0 4 -2 0 2 3 0 60 12030 Feet1:709 9 0 4 3 0 1 8 8 2 -B a d c a b l e SCEGeoVi ew 322 3 2 2 322 32 2 32 2 32 2 32 2 32 2 32 2 32 2 32 2 32 2 RAR 1061 PS 1807 PS 9958 PS 7641 PS 9399 PS 1773 PS 9516 PS 7068 B A BA 0154128 900 4552216E A FI00206 FI77656 P A L A R D MU R F I E L D D R S5492397 X5456379 J379A GATE CODE #7863 X5171354 RAINBOW CANYON GOLF COURSE B5006231 CLUBHOUSE X5504780 BOTTOM OF FUSE CLIPS CAUTION: HOT U.G. SOURCE KRTM RADIO X5747881 P5747877 P5747886 JBARS X5739819 JBARS P5739816 4552221E 232 8 3 8 1 E V5492396 X5732318 B5171363 BS0459 4490277E 2199571E B5171358 4771185E 2309319E B5306331 BS0747 LOAD BREAK ADAPTABLE 2339766E 2339766E P5362955 X5367651 P5367756 4697134E PME7268 JBAR LOAD BREAK P5732319 JBAR 4938132E 2270155E LOAD BREAK 2351927E 2351926EX5171362 P5456380 P5435548P5507962 X5507961 P5451167 X5390735 B5316519 2351929E B5316185 B5306338 2351927E B5316183 BS0869 ADAPTABLE 2351928E B5316184 BS0870 B5306337 P5451169 P5747873 P5747872 JBARS P5747870 P5747868 P5747864 P5456378 P5451168 P5747871 X5747869 P5747867 P5747866 P5747865 P5451166 P5451165 LBFC2872 X5747863 JBARS P5747861 P5747860 P5739818 2351935E S5316517 B5316518 P5747887 X5747862 X5739817 JBARS B5313100 BS0996 BS0997 BS0998 B5313099 B5307519 B5344001 4304922EB5307520 B5316186 B5316187 B5306336 B5316520 B5316521 X5315998 B5316522 X5316523 B5316524 B5316525 B5316188 B5316189 B5316229 P5362956 1853931E LOAD BREAK FD07069 4212302E CL65A P5428742 B5306332 B5171357 B5171361 X5171360 B5171359 B5171355 B5306335 B5306334 BS0871 1824645E B5171356 B5306333 B5321326 1853930E B5321327 B5316226 B5316230 B5316231 B5316227 B5316232 B5316228 B5321328 B5321329 P5006228 4528016E LOAD BREAK 4207225E X5315934 X5006162 B5006161 P5504905 P5504908 4317065E 2207162E FD09501 30A 1885590E BF09502 4061651E 2266585E BS0019 4061657E P5344026 B5315682 B5315681 B5315685 B5321330 B5307522 B5321516 B5321331 X5307523 B5307521 B5307524 B5344005 B5344003 B5344004 100A/5.8A-FC B5315683B5344002 B5315684 3 3 6 A 336 A 33 6 A 3 3 6 A 3 3 6 A 1/ 0 A T W 1/0 AT W 1 / 0 A T W 1 / 0 A 1/0 A T W 1/0 A 4 A 1 / 0 A T W 1/ 0 A T W 1/0 A T W 1/ 0 A T W 1/0 A T W 1/0 A T W CØ CØ BØ BØ AØ 10 0 0 J C N 10 0 0 J C N 1/0 J C N AØ 1000 JCN 1/0 J C N B Ø C Ø BØ 2 C L P 2 C L P CØ BØ CØ BØ CØ CØ CØ BØ BØ BØ AØ AØ AØ C Ø BCØ AØ C Ø B Ø C Ø BØ CØ BØ BØ CØ CØ BØ BØ BØ CØ CØ CØ AØ BØ A Ø BC ØAØ AØ AØ AØ BC Ø BØ CØ BØ AØ AØ AØ AØ CØ C Ø BØ BØ 2 C L P 2 C L P C Ø B Ø CØ CØ BØ B Ø BØ B Ø BØ CØ P E C H A N G A P K W Y JE D E D I A H S M I T H R D P A L A R D T R O T S D A L E D R MA S T E R S D R TO U R N A M E N T RE I N C T CANTERFIELD DR P E C H A N G A P K W Y MU R F I E L D D R G R E E N S B O R O TO U R N A M E N T L N GL E N E A G L E S C L A S S I C W Y G R E E N S B O R O D R C L U B H O U S E D R CLUBHO U S E D R MA S T E R S D R CR E E K S I D E W Y RA I N B O W C A N Y O N R D PU T T I N G G R E E N C T BIRDIE TO U R N A M E N T CL U B H O U S E SI L V E R A D O L N SILVERADO BAYHILL DR WAILEA CT BRIDGEVIE W C I R CL U B H O U S E D R OLYMPIC W Y OPE N C T GRE E N W A Y C I R RA I N B O W C A N Y O N R D T E M E C U L A V A L L E Y F R W Y TE M E C U L A V A L L E Y F R W Y TE M E C U L A V A L L E Y F R W Y E S M E R A D O C T PALMETTO PA L M E T T O BAR D M O R E D R ESM E R A D O CL A S S I C W Y CALVA D O DORAL PRIORITY NOTIFICATION : FAULT INDICATORS ON LOOP STATIONS : AUTOMATIC SW. GEAR (SCADA): NETCOMM EQUIPMENT : FOREMEN DATE C2 BALLOON 12KV MORAGA SUB (A1) CODE: 01051 CODE: 8348SCALE: 400 BUNGENSTOCK STURGEON WILDOMAR 88 12/20/2022 02/06/2023 SYSTEM: VALLEY NO NO NO B2B1 B3 D3D2D3 B3B1 C3 B2 C3D2CONFIDENTIAL: CRITICAL ENERGY INFRASTRUCTURE INFORMATION (CEII) AS DEFINED IN SCE-OPS-RM-ST-451 Pg 2 of 3 Seq #- 4199193 Pg 3 of 3 Seq #- 4199193