Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LD24-3202
Permit Number: LD24-3202 LD - Utilities/ Excavation - Parallel Issued: 10/07/2024 Expired: 04/30/2025 Job Address: 30705 Pauba Rd Legal Description: City of Temecula - Land Development Division 41000 Main Street - Temecula, CA 92590 Mailing Address: P.O. Box 9033 Temecula, CA 92589-9033 Phone: (951) 308-6395 Fax: (951) 694-6475 Marcell Escobar 1801 S. Atlantic Blvd, MPKA24 Monterey Park, CA 91754 (323) 742-1592 Applicant: Henkels & Mccoy Inc 2840 Ficus St Pomona, CA 91766 (909) 517-3011 Contractor: Utility Work Order Number: HCA_TEM2.1 Description: SoCal Gas HCA_TEM2.1 WORK HOURS SHALL BE MONDAY – FRIDAY, NO HOLIDAYS, 8:30am - 3:30pm Location: Pauba Rd S/S 565' E/O Showalter Rd Proposed work: SCG to install methane detector behind guard rail in asphalt per SCG plans "LD24-3202" All facilities shall be installed in accordance with City Standard Drawing 117. Traffic Control shall be in accordance with approved Traffic Control Plan LD24-3202 Permittee shall comply with all applicable Traffic Control General Notes. Safe pedestrian/bicycle traffic and driveway access shall be maintained at all times. Concrete repair shall be in accordance with City Standards and the Greenbook. Trench repair shall be in accordance with City Standard Drawing 407. Final compaction test results shall be provided by a soils engineer. Concrete curbs, walks, gutters, cross gutters and driveway approaches damaged during construction shall be removed from joint to joint and reconstructed in accordance with City Standards and the Greenbook. All disturbed landscaping and other improvements shall be removed/repaired and replaced to the satisfaction of the City Engineer or their designated assignee. Permittee shall contact LDInspections@temeculaca.gov a minimum of two (2) business days prior to any work. Permittee must also request a final inspection to verify completion of project. Page 1 of 2*****See Page 2 of this Permit for Permittee Responsibilities***** Permit Number: LD24-3202 LD - Utilities/ Excavation - Parallel Permittee Responsibilities This Permittee agrees to indemnify, defend and save the City, its authorized agents, officers, representatives and employees, harmless from and against any and all penalties, liabilities or loss resulting from claims or court action and arising out of any accident, loss or damage to persons or property happening or occurring as a proximate result of any work undertaken under the permit granted pursuant to this application. Trench repair shall be pursuant to City of Temecula Standard Drawing No. 407. 3.Traffic control devices shall be utilized to protect and control pedestrian and vehicular traffic in the construction area in accordance with the latest revision of the “Manual of Uniform Traffic Control Devices for Streets and Highways” (MUTCD). The contractor shall submit a specific traffic control plan for review and approval by the City in accordance with City “Traffic Control Plan Guidelines” for all work within Major Circulation Element streets. 2.BEFORE YOU DIG - CALL (TOLL FREE) 800-422-4133 A pre-construction meeting is required two (2) business days prior to any scheduled work. Permittee shall contact LDInspections@TemeculaCA.gov to schedule a meeting. 1. 4. Water Quality: Contractor shall remain in compliance with the City Water Pollution Control Ordinance. Contractor is required to provide protection of the City storm drain system. 5. Work hours shall be limited between 7:30 AM and 4:30 PM, Monday through Friday, unless otherwise noted. No work shall be allowed during City-recognized holidays." 6. THIS PERMIT IS ISSUED AND ACCEPTED SUBJECT TO THE FOLLOWING CONDITIONS AND ANY ATTACHED PROVISIONS: All U.S.A. mark outs shall be removed prior to completion of project.7. 8.All contractors and subcontractors shall have a valid City of Temecula business license and valid Certificate of Liability prior to start of work. 9.Should there be any claim against the City and the property owner with the encroachment being the proximate cause, the property owner shall be notified in writing to remove the encroachment within 30 days or the City will remove and bill the owner. 10.Permission is hereby requested to encroach into public right of way to perform work as set forth above. It is understood that this permit is limited to the work described herein and that all work is to be done in compliance with the provisions attached to this permit and with all other applicable rules. Permittee shall be responsible for said compliance, for acceptability of the work, for repair or replacement thereof if defective, and for repair or replacement of any existing improvement damaged by the doing of the work I hereby certify and agree on behalf of the Permittee that all laws, regulations and ordinances of the City of Temecula and the State of California and the terms and conditions of the Permit shall be complied with whether herein stated or not. 11. 12.I hereby warrant and represent to the City that I am authorized to execute this Permit Application on behalf of the Permittee and bind the Permittee to the agreements contained herein and any conditions of the Permit. ******Contractor and all subcontractors shall be present at the pre-construction meeting; otherwise, the meeting will be rescheduled to a later date****** Any work commencing within the City right-of-way before permit issuance or a pre-construction meeting shall be subject to a 72-Hour suspension of said work and an assessment of double permit fees.13. Permitee Date City Engineer or Authorized Representative Date 10/07/2024 Page 2 of 2 SH O W A L T E R R D PAUBA R D 2 PUBLIC WORKS - TRAFFIC ENGINEERING DIVISION CITY OF TEMECULA AT LEAST TWO DAYS UG SERVICE ALERT OF SOUTHERN CALIFORNIA BEFORE YOU DIG DIGALERT Call: TOLL FREE 1-800-227-2600 FOR TRAFFIC CONTROL PLANS TRAFFIC CONTROL PLANS FOR ADVANCED METER IMPROVEMENTS 30705 PAUBA RD AREA MAP: RECOMMENDED BY:DATE: ACCEPTED BY:DATE: R.T.E. NO. ERICK ESCOBEDO TRAFFIC ENGINEER N© 2015 TRAFFIC MANAGEMENT INC PAUBA RD & SHOWALTER RD PLAN ORDER # 75571 ADVANCED METER IMPROVEMENTS TRAFFIC MANAGEMENT, INC. California · Great LaMes · New ;orM LICENSE # 785804 · Class 31 www.trafficmanagement.com 800.763.3999 LEGEND: - FLAGGER - TYPE-III BARRICADE W/ SIGN - CHANNELIZATION DEVICE - TYPE-I OR II BARRICADE W/ SIGN - SIGN - EXISTING SIGN - FLASHING ARROW SIGN (FAS) - WORK AREA - ADA COMPLIANT PEDESTRIAN BARRICADE W/ SIGN DATE: 08/13/24 - GN ENGINEER'S INFORMATIONCONTRACTOR: 1 Southern California Gas 24-HR CONTACT INFO: OLIVIA GUTIERREZ (213) 244-2201 PO BOX 30777, LOS ANGELES, CA 90030-0777 WORK HOURS: SITE POINT: ADVANCED METER HCA_TEM-001 8:30AM - 3:30PM(MON - FRI) DURATION:1 DAY ROAD AHEAD WORK W20-1 © 2015 TRAFFIC MANAGEMENT INC AHEAD RIGHT LANE CLOSED W20-5(R)W4-2(R)W11-1 ROAD SHARE THE W16-1P BIKE LANE AHEAD CLOSED C20(MOD)(BIKE) BIKE LANE CLOSED SC11(MOD) AHEAD SIDEWALK CLOSED CROSS HERE R9-11(R/L) SIDEWALK CLOSED R9-9R3-4 CLOSED LANE C30(CA)W1-7 3002 TRAFFIC CONTROL GENERAL NOTES (REV'D. 06/06/24): 1.ALL TRAFFIC CONTROL DEVICES SHALL CONFORM TO THE LATEST EDITION OF THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (CALIFORNIA MUTCD) AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION. 2.THE CITY ENGINEER OR HIS REPRESENTATIVE HAS THE AUTHORITY TO INITIATE FIELD CHANGES TO ASSURE PUBLIC SAFETY. 3.ALL TRAFFIC CONTROL DEVICES SHALL BE REMOVED FROM VIEW WHEN NOT IN USE. 4.WORK HOURS SHALL BE RESTRICTED TO THE PERIOD BETWEEN 8:30 A.M. AND 3:30 P.M., MONDAY THROUGH FRIDAY, UNLESS APPROVED OTHERWISE. WHEN NIGHT WORK IS REQUIRED, WORK HOURS SHALL BE 9 P.M. TO 5 A.M., SUNDAY THROUGH THURSDAY. 5.TRENCHES MUST BE BACK FILLED OR PLATED DURING NON-WORKING HOURS. STEEL PLATES SHALL HAVE ASPHALTIC CONCRETE BERM ON ALL EDGES. ALL DIRT, DUST, AND DEBRIS SHALL BE REMOVED FROM STREET AT END OF EACH DAY AND AT THE END OF THE JOB. THE STREET SHALL BE IN DRIVABLE CONDITION AT ALL TIMES. 6.PEDESTRIAN CONTROLS SHALL BE PROVIDED AS SHOWN ON THE PLANS. 7.TEMPORARY "NO PARKING" SIGNS WILL BE POSTED 24 HOURS PRIOR TO COMMENCING WORK. 8.ACCESS TO DRIVEWAYS WILL BE MAINTAINED AT ALL TIMES UNLESS OTHER ARRANGEMENTS ARE MADE. 9.THE CONTRACTOR SHALL REPLACE WITHIN 72 HOURS, ALL TRAFFIC SIGNAL LOOP DETECTORS DAMAGED DURING CONSTRUCTION. 10.THE CONTRACTOR SHALL REPLACE WITHIN 24 HOURS, ALL STRIPING REMOVED OR DAMAGED BY CONSTRUCTION WORK. (STRIPING MAY BE REPLACED TEMPORARILY WITH TAPE.) 11.ALL WORKERS SHALL BE EQUIPPED WITH AN ORANGE VEST (OR A REFLECTIVE VEST AT NIGHT). ALL FLAGGERS SHALL ALSO BE EQUIPPED WITH A HARD HAT, C28 "STOP/SLOW" PADDLE AND SHALL BE TRAINED IN THE PROPER FUNDAMENTALS OF FLAGGING TRAFFIC. 12.ANY WORK THAT DISTURBS NORMAL TRAFFIC SIGNAL OPERATIONS SHALL BE COORDINATED WITH THE CITY OF TEMECULA’S TRAFFIC DIVISION, 48 HOURS PRIOR TO BEGINNING CONSTRUCTION. CONTACT THE CITY’S TRAFFIC DIVISION AT (951) 694-6411. 13.THE CONTRACTOR SHALL MAINTAIN ALL TRAFFIC CONTROL DEVICES 24 HOURS PER DAY AND 7 DAYS PER WEEK. 14.A MINIMUM OF TWELVE (12) FOOT TRAVEL LANES MUST BE MAINTAINED UNLESS OTHERWISE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS. 15.ALL NIGHT WORK WILL REQUIRE WRITTEN APPROVAL FROM THE DEPARTMENT OF PUBLIC WORKS. LANE CLOSURES, ROAD DETOURS, ROAD CLOSURES, AND TRAFFIC SIGNAL MODIFICATIONS ASSOCIATED WITH OVERNIGHT CONSTRUCTION ACTIVITIES WILL REQUIRE WARNING SIGNS BE PLACED AT LEAST ONE WEEK IN ADVANCE OF STARTING CONSTRUCTION. 16.A SOLAR POWERED FLASHING ARROW BOARD SHALL BE REQUIRED ON ALL ARTERIAL STREET LANE CLOSURES. 17.IF THE PERMIT APPLICANT DETERMINES THAT CONDUIT INSTALLATION WILL BE BY THE BORING MACHINE METHOD, THE TRENCH PATCH FOR THE UTILITY OBSERVATION EXCAVATION WILL BE THE SAME AS FOR OPEN TRENCH EXCAVATION METHOD. THIS WILL PROVIDE A SINGLE CONTINUOUS SURFACE RESTORATION ELIMINATING THE MULTIPLE PENETRATION INTO THE PUBLIC ROADWAY TO ALL REQUIREMENTS IN CITY STANDARD DRAWING # 407 (REFERENCE ALL SHEETS) FOR TRENCH PATCH. 18.ANY WORK THAT CREATES AN UNDUE SAFETY RISK OR CREATES SEVERE CONGESTION MAY BE SHUT DOWN BY CITY TRAFFIC ENGINEERS, CITY FIELD INSPECTION, OR THE POLICE DEPARTMENT. 19.CONES AND DELINEATORS SHALL HAVE REFLECTORIZED SLEEVES FOR NIGHT WORK. 20.IF PARKING IS ALLOWED IN ADVANCE WARNING AREA, ADVANCE WARNING SIGNS SHALL BE MOUNTED ON HIGH LEVEL DEVICES. PERMIT NO. __________LD24-3202 EOR: MICAH S. HERSHBERG ROAD WORK END G20-2 09/06/24 9/06/20 24 PAUB A R D 45 MPH [ ] 100' TANGENT 540' MERGING TAPER 180' SHOULDER TAPER 350' NTS 175' NTS SC11(MOD) 45' MAX W1-7 12' MIN 12' MIN 100' NTS SH O W A L T E R R D 25 MP H [ ] W20-1 W20-5(R)W4-2(R)C20(MOD) (BIKE) W11-1 W16-1P G20-2 TRINIT Y L U T H E R A N C H U R C H A N D P R E S C H O O L W20-1 45' MAX W20-1 C30(CA) SC11(MOD) R3-4 45' MAX SE E B E L O W MA T C H L I N E R9-11(L) TO BE PLACED AT YNEZ RD C30(CA) 175' NTS350' NTS350' NTS FAS PAUBA RD 45 MPH[] 100' 25' R3-4 C30(CA) SC11(MOD) C30(CA) SC11(MOD) R9-9 12' MIN R9-9 350' NTS W20-1 G20-2 TO BE PLACED AT CALLE VENTURA R9-11(R) SE E A B O V E MA T C H L I N E 45' MAX 12' MIN 2 PUBLIC WORKS - TRAFFIC ENGINEERING DIVISION CITY OF TEMECULA AT LEAST TWO DAYS UG SERVICE ALERT OF SOUTHERN CALIFORNIA BEFORE YOU DIG DIGALERT Call: TOLL FREE 1-800-227-2600 FOR TRAFFIC CONTROL PLANS PERMIT NO. __________ RECOMMENDED BY:DATE: ACCEPTED BY:DATE: TRAFFIC MANAGEMENT, INC. California · Great LaMes · New ;orM LICENSE # 785804 · Class 31 www.trafficmanagement.com 800.763.3999 LEGEND: - FLAGGER - TYPE-III BARRICADE W/ SIGN - CHANNELIZATION DEVICE - TYPE-I OR II BARRICADE W/ SIGN - SIGN - EXISTING SIGN - FLASHING ARROW SIGN (FAS) - WORK AREA - ADA COMPLIANT PEDESTRIAN BARRICADE W/ SIGN ENGINEER'S INFORMATIONCONTRACTOR: 2 SCALE: 1"= 40' 40'20'0'80' PLAN ORDER # 75571 DATE: 08/13/24 - GN N© 2015 TRAFFIC MANAGEMENT INC ROAD AHEAD WORK W20-1 © 2015 TRAFFIC MANAGEMENT INC AHEAD RIGHT LANE CLOSED W20-5(R)W4-2(R)W11-1 ROAD SHARE THE W16-1P BIKE LANE AHEAD CLOSED C20(MOD)(BIKE) BIKE LANE CLOSED SC11(MOD) AHEAD SIDEWALK CLOSED CROSS HERE R9-11(R/L) SIDEWALK CLOSED R9-9R3-4 CLOSED LANE C30(CA) LD24-3202 Southern California Gas 24-HR CONTACT INFO: OLIVIA GUTIERREZ (213) 244-2201 PO BOX 30777, LOS ANGELES, CA 90030-0777 W1-7 TRAFFIC ENGINEER PAUBA RD & SHOWALTER RD ADVANCED METER IMPROVEMENTS WORK HOURS: SITE POINT: ADVANCED METER HCA_TEM-001 8:30AM - 3:30PM(MON - FRI) DURATION:1 DAY R.T.E. NO. ERICK ESCOBEDO 3002EOR: MICAH S. HERSHBERG ROAD WORK END G20-2 09/06/24 9/06/20 24 876fi4 40C;? J STR ,326C� 50C2 J ELC 82 f:, t/1 5DC>3 ] ELC 8266-1 :=iC)C;l l ELC 876C4 SOC;C -J 11 C: r326f/l-50C7-J-ELC 82664-94CC�-J-V[\ 826f:,·1 ·95CC5 J \/E\ 82C:S4 ·9r3CC2 J \/[\ 1 7 STR,CTURA_ NOTES ST/'.I\_J/.LDI\E 'OLE _JC/T C\I 'L/',N BLCC": D 0 R!.lvl �:c 0 -1:imJ A'l�I Avou1 RC=-I JQ,:J ',/'/IRll�S C °F:/J/ ST1\I\ J/, . .LQf. E -,□LE vou RC'-1 J01J COI\JJE1CT C\ [:E-/\ _S U)Ul'!ll\l STAI\JALDI\[ =□L[ c=-L,ILS SOL!\R lvlCJDI. _ES SOL!\R ELECTRIC [;C:-/\ LS SOL:\R [L[:CTRIS [:=-/\ LS SCJLLfi [L[STr?IS c=-,t, LS :,OIAk �1�;1�;1:; I> t,l'.i ,li,11 c; w :::) "' f- •,\ ' ,,,,.// '\ ___ ,...,,,------- ' ''I ' I I I I ' I I I � (-, / '\ L\, / RAI\ CI__ CJ _____ ST A RC _/o ='RI\/IA,\/ERA, ,C--, .. ---, ,' \ ' ', I ' '\ ) F-� ·, ,', ' " ' ' ' ' \ ,' \ /\ I I/ ,1 '1 'I \' � -_r--/LL / er:: I LL , IC [\II T F ( \ I,------ / V --\:) \ ! \ ____ ./ ( \, _____ , .. / \ /'" )--, ,I',._j \ F r\\J '\ ./ /---\ v--\, '..-..._ ____ ) / !, '· " \ ./ /----, I>--,' ' '\... ____ ) !/-'\ I ,\ .... ,/ l)L y/ \._ // ./ / � ,t, ·' /'l ,/ "'\'\� ' ''-51" / ,-------FROJ::::CT LOC.t.JICH�' ' : \_ "· -------',, -........... , ------:-1-<l_ I u:: ' -, II ' / I' I' ..u I --: I <J' I �-) \ �/// / ·-....... y \ \ ' '\ / \</ /// \ C8/C5/202L Cb./Cb/)0/L CR/(-;f,/?CJ)L MsoCalGas. IS LED 1=-F1 L-10281v1r) 29.85 S T F< U CT I l·JI l lCA. ML l l lAl\ll Slf\lSING DRAW I\IG LIST SoCalGas to Install (1) Methane Sensor in the Public Right-of-WayOn Pauba Rd.; East of 30705 Pauba Rd., 626' East of the East Curb Face of Showalter Rd., 2' South of the South Curb Face of Pauba Rd. LD24-3202 CLEARED BY CITY OF TEMECULA PUBLIC WORKS Tricia.ortega 10/01/2024 10/01/2024 10/01/2024 10/01/20 08/06/2024 08/06/2024 08/06/2024 08/06/2024 08/06/2024 82664-2001-D-PID ISSUED FOR CONSTRUCTION AE 1000 1000 AI GAS CONTROL H CELLULAR AT 1000 RS-485 UJY 1000 SERIAL CONVERTER UJY 1001 / DATALOGGER CELL MODEM RS-232 REMOTE COMMUNICATION PANEL RCP - 1000 METHANE SENSING LOCATED IN FIELD WITH REMOTE INDICATION DWG CLASS:DWG DIST: SCALE: DRAWING NUMBER REV DESIGNED: DRAWN: CHECKED: PROJ APV: ENG FILE NO: WOA: SCG ENG APV: BY DATE REV DRAWN CHECKED ENG FILE NOPRJ APV SCG APV DESCRIPTIONDATE WOA FACILITY: AREA:038100 NONE 0 09/16/2024 SD RS KC CB PE00008 ISSUED FOR CONSTRUCTION 70526.001 S. DIAZ S. DIAZ R. SCHERER K. CHIPMAN C. BAUTISTA PE00008 70526 L-1028 HCA METHANE SENSING P & I DIAGRAM NOTES: 1. INFRARED POINT METHANE GAS DETECTOR. 2. ALL TAG NUMBERS ARE PREFIXED WITH THE SITE ID NO. "HCA L1028-MP29.86" MP 29.86