Loading...
HomeMy WebLinkAboutLD24-2444Permit Number: LD24-2444 LD - Utilities/ Excavation - Parallel Issued: 08/21/2024 Expired: 05/12/2025 Job Address: 32413 Temecula Pky Legal Description: City of Temecula - Land Development Division 41000 Main Street - Temecula, CA 92590 Mailing Address: P.O. Box 9033 Temecula, CA 92589-9033 Phone: (951) 308-6395 Fax: (951) 694-6475 Jose Guillen 17890 Valley Blvd Bloomington, CA 92316 Applicant: Hhs Construction, Llc 2042 S Grove Avenue Ontario, CA 91761 (909) 393-3322 Contractor: Utility Work Order Number: 5376262 Description: Charter Spectrum P_5376262 WORK HOURS SHALL BE MONDAY – FRIDAY, NO HOLIDAYS, 8:30am - 3:30pm Location: Temecula Pkwy, Apis Rd, & Wolf Store Rd Proposed work: Install two (2) new vaults per Charter "CONSTRUCTION DESIGN 32413 TEMECULA PKWY, LD24-2444" All facilities shall be installed in accordance with City Standard Drawing 117. Traffic Control shall be in accordance with approved Traffic Control Plan LD24-2444 Permittee shall comply with all applicable Traffic Control General Notes. Safe pedestrian/bicycle traffic and driveway access shall be maintained at all times. Concrete repair shall be in accordance with City Standards and the Greenbook. Trench repair shall be in accordance with City Standard Drawing 407. Final compaction test results shall be provided by a soils engineer. Concrete curbs, walks, gutters, cross gutters and driveway approaches damaged during construction shall be removed from joint to joint and reconstructed in accordance with City Standards and the Greenbook. All disturbed landscaping and other improvements shall be removed/repaired and replaced to the satisfaction of the City Engineer or their designated assignee. Permittee shall contact LDInspections@temeculaca.gov a minimum of two (2) business days prior to any work. Permittee must also request a final inspection to verify completion of project. Page 1 of 2*****See Page 2 of this Permit for Permittee Responsibilities***** Permit Number: LD24-2444 LD - Utilities/ Excavation - Parallel Permittee Responsibilities This Permittee agrees to indemnify, defend and save the City, its authorized agents, officers, representatives and employees, harmless from and against any and all penalties, liabilities or loss resulting from claims or court action and arising out of any accident, loss or damage to persons or property happening or occurring as a proximate result of any work undertaken under the permit granted pursuant to this application. Trench repair shall be pursuant to City of Temecula Standard Drawing No. 407. 3.Traffic control devices shall be utilized to protect and control pedestrian and vehicular traffic in the construction area in accordance with the latest revision of the “Manual of Uniform Traffic Control Devices for Streets and Highways” (MUTCD). The contractor shall submit a specific traffic control plan for review and approval by the City in accordance with City “Traffic Control Plan Guidelines” for all work within Major Circulation Element streets. 2.BEFORE YOU DIG - CALL (TOLL FREE) 800-422-4133 A pre-construction meeting is required two (2) business days prior to any scheduled work. Permittee shall contact LDInspections@TemeculaCA.gov to schedule a meeting. 1. 4. Water Quality: Contractor shall remain in compliance with the City Water Pollution Control Ordinance. Contractor is required to provide protection of the City storm drain system. 5. Work hours shall be limited between 7:30 AM and 4:30 PM, Monday through Friday, unless otherwise noted. No work shall be allowed during City-recognized holidays." 6. THIS PERMIT IS ISSUED AND ACCEPTED SUBJECT TO THE FOLLOWING CONDITIONS AND ANY ATTACHED PROVISIONS: All U.S.A. mark outs shall be removed prior to completion of project.7. 8.All contractors and subcontractors shall have a valid City of Temecula business license and valid Certificate of Liability prior to start of work. 9.Should there be any claim against the City and the property owner with the encroachment being the proximate cause, the property owner shall be notified in writing to remove the encroachment within 30 days or the City will remove and bill the owner. 10.Permission is hereby requested to encroach into public right of way to perform work as set forth above. It is understood that this permit is limited to the work described herein and that all work is to be done in compliance with the provisions attached to this permit and with all other applicable rules. Permittee shall be responsible for said compliance, for acceptability of the work, for repair or replacement thereof if defective, and for repair or replacement of any existing improvement damaged by the doing of the work I hereby certify and agree on behalf of the Permittee that all laws, regulations and ordinances of the City of Temecula and the State of California and the terms and conditions of the Permit shall be complied with whether herein stated or not. 11. 12.I hereby warrant and represent to the City that I am authorized to execute this Permit Application on behalf of the Permittee and bind the Permittee to the agreements contained herein and any conditions of the Permit. ******Contractor and all subcontractors shall be present at the pre-construction meeting; otherwise, the meeting will be rescheduled to a later date****** Any work commencing within the City right-of-way before permit issuance or a pre-construction meeting shall be subject to a 72-Hour suspension of said work and an assessment of double permit fees.13. Permitee Date City Engineer or Authorized Representative Date 08/21/2024 Page 2 of 2 SCOPE OF WORK PUBLIC WORKS - TRAFFIC ENGINEERING DIVISION CITY OF TEMECULA FOR TRAFFIC CONTROL PLANS CONTRACTOR:USGaWHG TUaIILF CRQWURl NRWHV WR UHY -AJP AJP 1/26/12 7337 CENTRAL AVE RIVERSIDE CA.92504 OFFICE: (833) 267-6097 CHARTER UTILITY COMPANY: EXISTING NO TURN LANE TRAFFIC CONE FLASHING ARROW SIGN (FAS) EXISTING TURN ONLY LANE BARRICADE WORK ZONE TRAFFIC SIGNAL HIGH LEVEL WARNING DEVICE (WITH CALTRANS & MUTCD CODE) SIGN (WITH CALTRANS CODE) TRAFFIC FLOW DIRECTION FLAGGER S DETAIL SHEET LEGEND CONE SPACING - 45' MAXIMUM AT LEAST TWO DAYS UG SERVICE ALERT OF SOUTHERN CALIFORNIA BEFORE YOU DIG DIGALERT Call: TOLL FREE 1-800-227-2600 CROSS STREETS TEMCULA PKWY & APIS RD PRISM#: 5376262 N.T.S. N DESIGN ORIENTATION PROPOSED SIGNS HHS OFFICE: (909) 721-3785 CSLB#: 818906 | CLASS: A C10 C31 B C-7 2042 S GROVE AVENUE ONTARIO, CA 91761 WORK HOURS SUNDAY - THURSDAY NO HOLIDAYS 8:30AM - 3:30PM TRAFFIC CONTROL GENERAL NOTES (REV'D. 06/06/24): 1. ALL TRAFFIC CONTROL DEVICES SHALL CONFORM TO THE LATEST EDITION OF THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (CALIFORNIA MUTCD) AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION. 2. THE CITY ENGINEER OR HIS REPRESENTATIVE HAS THE AUTHORITY TO INITIATE FIELD CHANGES TO ASSURE PUBLIC SAFETY. 3. ALL TRAFFIC CONTROL DEVICES SHALL BE REMOVED FROM VIEW WHEN NOT IN USE. 4. WORK HOURS SHALL BE RESTRICTED TO THE PERIOD BETWEEN 8:30 A.M. AND 3:30 P.M., MONDAY THROUGH FRIDAY, UNLESS APPROVED OTHERWISE. WHEN NIGHT WORK IS REQUIRED, WORK HOURS SHALL BE 9 P.M. TO 5 A.M., SUNDAY THROUGH THURSDAY. 5. TRENCHES MUST BE BACK FILLED OR PLATED DURING NON-WORKING HOURS. STEEL PLATES SHALL HAVE ASPHALTIC CONCRETE BERM ON ALL EDGES. ALL DIRT, DUST, AND DEBRIS SHALL BE REMOVED FROM STREET AT END OF EACH DAY AND AT THE END OF THE JOB. THE STREET SHALL BE IN DRIVABLE CONDITION AT ALL TIMES. 6. PEDESTRIAN CONTROLS SHALL BE PROVIDED AS SHOWN ON THE PLANS. 7. TEMPORARY "NO PARKING" SIGNS WILL BE POSTED 24 HOURS PRIOR TO COMMENCING WORK. 8. ACCESS TO DRIVEWAYS WILL BE MAINTAINED AT ALL TIMES UNLESS OTHER ARRANGEMENTS ARE MADE. 9. THE CONTRACTOR SHALL REPLACE WITHIN 72 HOURS, ALL TRAFFIC SIGNAL LOOP DETECTORS DAMAGED DURING CONSTRUCTION. 10. THE CONTRACTOR SHALL REPLACE WITHIN 24 HOURS, ALL STRIPING REMOVED OR DAMAGED BY CONSTRUCTION WORK. (STRIPING MAY BE REPLACED TEMPORARILY WITH TAPE.) 11. ALL WORKERS SHALL BE EQUIPPED WITH AN ORANGE VEST (OR A REFLECTIVE VEST AT NIGHT). ALL FLAGGERS SHALL ALSO BE EQUIPPED WITH A HARD HAT, C28 "STOP/SLOW" PADDLE AND SHALL BE TRAINED IN THE PROPER FUNDAMENTALS OF FLAGGING TRAFFIC. 12. ANY WORK THAT DISTURBS NORMAL TRAFFIC SIGNAL OPERATIONS SHALL BE COORDINATED WITH THE CITY OF TEMECULA’S TRAFFIC DIVISION, 48 HOURS PRIOR TO BEGINNING CONSTRUCTION. CONTACT THE CITY’S TRAFFIC DIVISION AT (951) 694 -6411. 13. THE CONTRACTOR SHALL MAINTAIN ALL TRAFFIC CONTROL DEVICES 24 HOURS PER DAY AND 7 DAYS PER WEEK. 14. A MINIMUM OF TWELVE (12) FOOT TRAVEL LANES MUST BE MAINTAINED UNLESS OTHERWISE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS. 15. ALL NIGHT WORK WILL REQUIRE WRITTEN APPROVAL FROM THE DEPARTMENT OF PUBLIC WORKS. LANE CLOSURES, ROAD DETOURS, ROAD CLOSURES, AND TRAFFIC SIGNAL MODIFICATIONS ASSOCIATED WITH OVERNIGHT CONSTRUCTION ACTIVITIES WILL REQUIRE WARNING SIGNS BE PLACED AT LEAST ONE WEEK IN ADVANCE OF STARTING CONSTRUCTION. 16. A SOLAR POWERED FLASHING ARROW BOARD SHALL BE REQUIRED ON ALL ARTERIAL STREET LANE CLOSURES. 17. IF THE PERMIT APPLICANT DETERMINES THAT CONDUIT INSTALLATION WILL BE BY THE BORING MACHINE METHOD, THE TRENCH PATCH FOR THE UTILITY OBSERVATION EXCAVATION WILL BE THE SAME AS FOR OPEN TRENCH EXCAVATION METHOD. THIS WILL PROVIDE A SINGLE CONTINUOUS SURFACE RESTORATION ELIMINATING THE MULTIPLE PENETRATION INTO THE PUBLIC ROADWAY TO ALL REQUIREMENTS IN CITY STANDARD DRAWING # 407 (REFERENCE ALL SHEETS) FOR TRENCH PATCH. 18. ANY WORK THAT CREATES AN UNDUE SAFETY RISK OR CREATES SEVERE CONGESTION MAY BE SHUT DOWN BY CITY TRAFFIC ENGINEERS, CITY FIELD INSPECTION, OR THE POLICE DEPARTMENT. 19. CONES AND DELINEATORS SHALL HAVE REFLECTORIZED SLEEVES FOR NIGHT WORK. 20. IF PARKING IS ALLOWED IN ADVANCE WARNING AREA, ADVANCE WARNING SIGNS SHALL BE MOUNTED ON HIGH LEVEL DEVICES. APPLICANT IS RESPONSIBLE FOR FULL AND COMPLETE REPRESENTATION OF THE ACTUAL ROAD CONDITIONS SHOWN ON THIS PLAN INCLUDING, BUT NOT LIMITED TO EXISTING STRIPING, SIGNING, SIDEWALKS, AND BIKE LANES. 32413 TEMECULA PKWY TEMECULA, CA 92592 - JESUS SAMANIEGO HHS 08/06/2024 ---- A.LOAYZA CITY OF TEMECULA PUBLIC WORKS DEPARTMENT PO#:- PRISM#:5376262 7 1 WORK DURATION: ·05 DAYS FOR EXCAVATION / BORE / TRENCH WORK ·03 DAY FOR RESTORATION ·02 DAY TO PULL CABLE ·10 DAYS OF TRAFFIC CONTROL SET UP ·TOTAL # OF WORK DAYS: 10 SCOPE OF WORK: ·BORE / TRENCH TO INSTALL CONDUITS FOR CHARTER SPECTRUM (1,264 ft.). ·SET NEW CHARTER VAULTS (2). ·SET BORE PITS (8). ·REMOVE & REPLACE ASPHALT (72 sq.ft). ·REMOVE & REPLACE CONCRETE SIDEWALK PANEL (42 sq.ft). WORK AREA PROPOSED TCP 1.1 SEE PG 2 OF 7 WORK AREA PROPOSED TCP 1.1 SEE PG 2 OF 7 WORK AREA PROPOSED TCP 1.2 SEE PG 3 OF 7 TEMECU L A P K W Y A P I S R D A P I S R D WOLF S T O R E R D WORK AREA PROPOSED TCP 1.3 SEE PG 4 OF 7 WORK AREA PROPOSED TCP 1.4 SEE PG 5 OF 7 WORK AREA PROPOSED TCP 1.5 SEE PG 6 OF 7 WORK AREA PROPOSED TCP 1.6 SEE PG 7 OF 7 V V PED TV TV ROD & ROPE THROUGH EXISTING CHARTER CONDUIT 280' V V V BORE ROUTE TO INSTALL NEW CHARTER CONDUIT 1254' END ROAD WORK G20-2 ROAD AHEAD W20-1 WORK SHARE ROAD THE W11-1/W16-1 NARROW LANE C12(CA) ROAD NARROWS W5-1 W4-2R RIGHT LANE MUST TURN RIGHT R3-7R AHEAD CLOSED RIGHT LANE C20(CA) LANE CLOSED 1 C30(CA) R3-2 R4-7a KEEP RIGHT W24-1 SHOULDER C30A(CA) CLOSED SHOULDER W21-5 WORK W20-5 W5-1 ROAD NARROWS W5-1 12 ' M I N . 100'**TO BE DETERMINED BY THE CITY OF TEMECULA** RE V ' D 0 4 / 0 3 / 2 3 07/25/2024 N Page: 2/7 TEMECULA PKWY (50 MPH) 350' SIGN SPACING 350' SIGN SPACING 350' SIGN SPACING 300' SHIFTING TAPER 20'WORK ZONE AP I S RD ( 30 M P H ) PR I V A T E R O A D 640' 350' SIGN SPACING 08/06/2024 12 ' NOTE: NOT TO BE USED ON STREETS CLASSIFIED ABOVE COLLECTOR OR AT SIGNALIZED INTERSECTIONS WITHOUT APPROVAL FROM THE CITY OF TEMECULA. RE V ' D 0 4 / 0 3 / 2 3 08/06/2024 N Page: 3/7 TEMECULA PKWY (50 MPH) ME A D O W S P K W Y (4 5 M P H ) AP I S R D (25 M P H ) 350' SIGN SPACING 350' SIGN SPACING 350' SIGN SPACING 600' MERGING TAPER 350' SIGN SPACING 20' WORK AREA 350' SIGN SPACING 35 0 ' SI G N SP A C I N G 35 0 ' SI G N SP A C I N G DO W N S T R E A M TA P E R 50 ' M I N . / 10 0 ' M A X TB D CI T Y O F T E M E C U L A 20 ' WO R K A R E A CU R B O R E . O . P . CU R B O R E . O . P . 25 0 ' SI G N SP A C I N G 18 0 ' ME R G I N G TA P E R 25 0 ' SI G N SP A C I N G 25 0 ' SI G N SP A C I N G 25 0 ' SI G N SP A C I N G 10 ' 12 ' M I N 50 ' M I N CU R B O R E . O . P . 50 ' M I N AHEAD CLOSED RIGHT LANE C20(CA) ROAD AHEAD W20-1 WORK LANE CLOSED END ROAD WORK G20-2 W4-2R 1 C30(CA) CONTRACTOR:USGaWHG TUaIILF CRQWURl NRWHV WR UHY -AJP AJP 1/26/12 7337 CENTRAL AVE RIVERSIDE CA.92504 OFFICE: (833) 267-6097 CHARTER UTILITY COMPANY: AT LEAST TWO DAYS UG SERVICE ALERT OF SOUTHERN CALIFORNIA BEFORE YOU DIG DIGALERT Call: TOLL FREE 1-800-227-2600 HHS OFFICE: (909) 721-3785 CSLB#: 818906 | CLASS: A C10 C31 B C-7 2042 S GROVE AVENUE ONTARIO, CA 91761 PROPOSED SIGNS PUBLIC WORKS - TRAFFIC ENGINEERING DIVISION CITY OF TEMECULA FOR TRAFFIC CONTROL PLANS CROSS STREETS NOTE: SIDEWALKS SHALL REMAIN OPEN DURING CONSTRUCTION. SCOPE OF WORK WILL NOT AFFECT PEDESTRIANS. PLACE NO PARKING SIGNS 72 HOURS PRIOR TO WORK N.T.S. N DESIGN ORIENTATION PROPOSED TCP 1.3 WORK HOURS SUNDAY - THURSDAY NO HOLIDAYS 8:30AM - 3:30PM 32413 TEMECULA PKWY TEMECULA, CA 92592 - JESUS SAMANIEGO HHS 08/06/2024 ---- A.LOAYZA CITY OF TEMECULA PUBLIC WORKS DEPARTMENT PO#:- PRISM#:5376262 PRISM#: 5376262 7 4 TEMCULA PKWY & APIS RD SHARE ROAD THE W11-1/W16-1 50 ' M I N DO W N ST R E A M TA P E R 50 ' M I N . / 10 0 ' M A X 18 0 ' ME R G I N G TA P E R TB D CO T 20 ' WO R K Z O N E 25 0 ' SI G N SP A C I N G 25 0 ' SI G N SP A C I N G 25 0 ' SI G N SP A C I N G 25 0 ' SI G N SP A C I N G 18 0 ' ME R G I N G TA P E R 50 ' M I N SA P C I N G O F C H A N N E L I Z I N G D E V I C E S T O BE C O N F L I C T P E R T A B L E " F " SA P C I N G O F C H A N N E L I Z I N G D E V I C E S T O BE C O N F L I C T P E R T A B L E " F " CU R B O R E . O . P . CU R B O R E . O . P . CO V E R L E F T T U R N AR R O W I F P R E S E N T LA N E 12 ' M I N LA N E 12 ' M I N 10 ' MA X 25 0 ' SI G N SP A C I N G 25 0 ' SI G N SP A C I N G R3-2 LANE CLOSED C30(CA) END ROAD WORK G20-2 ROAD AHEAD W20-1 WORK R4-7a KEEP RIGHT AHEAD CLOSED RIGHT LANE W20-5 1 CONTRACTOR:USGaWHG TUaIILF CRQWURl NRWHV WR UHY -AJP AJP 1/26/12 7337 CENTRAL AVE RIVERSIDE CA.92504 OFFICE: (833) 267-6097 CHARTER UTILITY COMPANY: AT LEAST TWO DAYS UG SERVICE ALERT OF SOUTHERN CALIFORNIA BEFORE YOU DIG DIGALERT Call: TOLL FREE 1-800-227-2600 HHS OFFICE: (909) 721-3785 CSLB#: 818906 | CLASS: A C10 C31 B C-7 2042 S GROVE AVENUE ONTARIO, CA 91761 PROPOSED SIGNS PUBLIC WORKS - TRAFFIC ENGINEERING DIVISION CITY OF TEMECULA FOR TRAFFIC CONTROL PLANS CROSS STREETS NOTE: SIDEWALKS SHALL REMAIN OPEN DURING CONSTRUCTION. SCOPE OF WORK WILL NOT AFFECT PEDESTRIANS. PLACE NO PARKING SIGNS 72 HOURS PRIOR TO WORK N.T.S. N DESIGN ORIENTATION PROPOSED TCP 1.4 WORK HOURS SUNDAY - THURSDAY NO HOLIDAYS 8:30AM - 3:30PM 32413 TEMECULA PKWY TEMECULA, CA 92592 - JESUS SAMANIEGO HHS 08/06/2024 ---- A.LOAYZA CITY OF TEMECULA PUBLIC WORKS DEPARTMENT PO#:- PRISM#:5376262 PRISM#: 5376262 5 7TEMCULA PKWY & APIS RD SHARE ROAD THE W11-1/W16-1 NARROW LANE C12(CA)W24-1 25 0 ' SI G N SP A C I N G 60 ' SH O U L D E R TA P E R TB D CI T Y O F T E M E C U L A 20 ' WO R K A R E A DO W N S T R E A M TA P E R 50 ' M I N . / 10 0 ' M A X 25 0 ' SI G N SP A C I N G ED G E O F L A N E CU R B O R E . O . P . ED G E O F L A N E CU R B O R E . O . P . 12 ' M I N 25 0 ' SI G N SP A C I N G 50 ' M I N ED G E O F L A N E ED G E O F L A N E 50 ' M I N ROAD AHEAD W20-1 WORK SHOULDER C30A(CA) CLOSED END ROAD WORK G20-2 CONTRACTOR:USGaWHG TUaIILF CRQWURl NRWHV WR UHY -AJP AJP 1/26/12 7337 CENTRAL AVE RIVERSIDE CA.92504 OFFICE: (833) 267-6097 CHARTER UTILITY COMPANY: AT LEAST TWO DAYS UG SERVICE ALERT OF SOUTHERN CALIFORNIA BEFORE YOU DIG DIGALERT Call: TOLL FREE 1-800-227-2600 HHS OFFICE: (909) 721-3785 CSLB#: 818906 | CLASS: A C10 C31 B C-7 2042 S GROVE AVENUE ONTARIO, CA 91761 PROPOSED SIGNS PUBLIC WORKS - TRAFFIC ENGINEERING DIVISION CITY OF TEMECULA FOR TRAFFIC CONTROL PLANS CROSS STREETS NOTE: SIDEWALKS SHALL REMAIN OPEN DURING CONSTRUCTION. SCOPE OF WORK WILL NOT AFFECT PEDESTRIANS. PLACE NO PARKING SIGNS 72 HOURS PRIOR TO WORK N.T.S. N DESIGN ORIENTATION PROPOSED TCP 1.5 WORK HOURS SUNDAY - THURSDAY NO HOLIDAYS 8:30AM - 3:30PM 32413 TEMECULA PKWY TEMECULA, CA 92592 - JESUS SAMANIEGO HHS 08/06/2024 ---- A.LOAYZA CITY OF TEMECULA PUBLIC WORKS DEPARTMENT PO#:- PRISM#:5376262 PRISM#: 5376262 7 6 TEMCULA PKWY & APIS RD SHOULDER W21-5 WORK SHARE ROAD THE W11-1/W16-1 250' SIGN SPACING 60' SHOULDER TAPER TBD CITY OF TEMECULA 20' WORK AREA DOWN STREAM TAPER 50' MIN./ 100' MAX EDGE OF LANE EDGE OF LANE CURB OR E.O.P. 12' MIN 250' SIGN SPACING 50' MIN EDGE OF LANE EDGE OF LANE 50' MIN CONTRACTOR:USGaWHG TUaIILF CRQWURl NRWHV WR UHY -AJP AJP 1/26/12 7337 CENTRAL AVE RIVERSIDE CA.92504 OFFICE: (833) 267-6097 CHARTER UTILITY COMPANY: AT LEAST TWO DAYS UG SERVICE ALERT OF SOUTHERN CALIFORNIA BEFORE YOU DIG DIGALERT Call: TOLL FREE 1-800-227-2600 HHS OFFICE: (909) 721-3785 CSLB#: 818906 | CLASS: A C10 C31 B C-7 2042 S GROVE AVENUE ONTARIO, CA 91761 PROPOSED SIGNS PUBLIC WORKS - TRAFFIC ENGINEERING DIVISION CITY OF TEMECULA FOR TRAFFIC CONTROL PLANS CROSS STREETS NOTE: SIDEWALKS SHALL REMAIN OPEN DURING CONSTRUCTION. SCOPE OF WORK WILL NOT AFFECT PEDESTRIANS. PLACE NO PARKING SIGNS 72 HOURS PRIOR TO WORK N.T.S. N DESIGN ORIENTATION PROPOSED TCP 1.5 WORK HOURS SUNDAY - THURSDAY NO HOLIDAYS 8:30AM - 3:30PM 32413 TEMECULA PKWY TEMECULA, CA 92592 - JESUS SAMANIEGO HHS 08/06/2024 ---- A.LOAYZA CITY OF TEMECULA PUBLIC WORKS DEPARTMENT PO#:- PRISM#:5376262 PRISM#: 5376262 7 7TEMCULA PKWY & APIS RD ROAD AHEAD W20-1 WORK SHOULDER C30A(CA) CLOSED END ROAD WORK G20-2 SHOULDER W21-5 WORK SHARE ROAD THE W11-1/W16-1 CONSTRUCTION TOTALS (TOTAL AMOUNTS OF ENTIRE ROUTE) PRISM#: 5376262 JOB NOTES: 1.The existence and location of any underground utility pipes or structures was obtained by a search of the available records and field conditions. Additional underground facilities may exist, or the location of the facilities may differ from the locations shown on these plans. The contractor shall, at his own expense, determine the exact location of all such underground facilities prior to commencement of any work or any action which may damage such facilities or interfere with their continuous and proper operation. 2.All plans must be checked and approved by the governmental agency, or agencies, having jurisdiction over the roadways shown on this plan being put into effect. All plans are intended to conform to the Manual on Uniform Traffic Control Devices. The customer/contractor is responsible for ascertaining addition agency requirements for work hours allowed, noise abatement, and other rules and regulations. 3.The temporary traffic controls must be installed per the agency approved plan to be effective. Field changes, other than minor adjustment, must be authorized in writing be a representative of the governmental agency, or agencies, having jurisdiction over the roadway. 4.Plan implementation and device placement should be performed by experienced and trained personnel. 5.Temporary traffic control must be monitored and maintained by the customer/contractor to remain effective. Monitoring and maintenance frequency is dictated by field conditions, but not less than daily. 6.Optimum Inc. has no control over, or responsibility for traffic control plan implementation and inspections performed by others. Users agree to indemnify Optimum Inc. for claims made regarding failure to install, maintain or remove controls per approved traffic control plans. PTIMUM, INC. GENERAL ENGINEERING CONTRACTORS OFFICE: (909) 990-0767 CSLB#: 817291 | CLASS: C-7 A C31 17890 VALLEY BLVD BLOOMINGTON CA SCOPE OF WORK SHEET 1 OF 6 7337 CENTRAL AVE RIVERSIDE CA.92504 OFFICE: (833) 267-6097 32413 TEMECULA PKWY TEMECULA CA 92592 - JESUS SAMANIEGO HHS 7/3/2024 PENDING A.LOAYZA CITY OF TEMECULA PO#:- PRISM#: CHARTER PUBLIC WORKS DEPARTMENT TP TELEPHONE PEDESTAL T TELEPHONE VAULT EV ELECTRIC VAULT CATV VAULT IV IRRIGATION VAULT UTILITY POLE FIRE HYDRANT UNDERGROUND VALVE MAN HOLE F M SL STREET LIGHT VAULT TS TRAFFIC SIGNAL VAULT WV WATER VAULT CATV PEDESTALABOVE GROUND VALVE GV GAS VAULT FO FIBER OPTIC VAULT CV COMMUNICATIONS VAULT ELECTRIC LINE GAS LINE TELEPHONE LINE WATER LINE CATV LINE TRAFFIC SIGNAL LINE SEWER LINE STORM DRAIN LINE FIBER OPTIC LINE PETROLUEM LINE STREET LIGHTS INDUSTRIAL WASTE OIL LINE FUEL LINE RECLAIMED WATER T PROPOSED CONSTRUCTION PROPOSED HDD BORE / CONDUIT INSTALLATION PROPOSED TRENCH / CONDUIT INSTALLATION PROPOSED POTHOLE (2'x2') PROPOSED EXIT / MISSILE BORE PIT (2'x4') PROPOSED BORE PIT (3'x6') CATV PROPOSED NEW CATV VAULT (2'x3') UTILITY / LINE LEGENDEXISTING OBJECTS EDGE OF PAVEMENT CURB FACE RIGHT OF WAY (CITY) CENTERLINE (C/L) DESIGN ORIENTATIONREVISIONS REV#DATE DESCRIPTION 36" L E N G T H 24" W I D T H 18 " H E I G H T 3" CONDUIT 36 " T Y P . CO N D U I T D E P T H 18 " D E P T H EXISTING GRADE OR SURFACE OF CONCRETE MOUNT FLUSH WITH GRADE 6" ROCK BASE (3/4" GRAVEL) 36" L E N G T H 18 " W I D T H 20 " H E I G H T CO V E R 18 " H E I G H T BA S E 21 " A B O V E GR A D E COVER 3" CONDUIT 36 " T Y P . CO N D U I T D E P T H EXISTING GRADE OR SURFACE OF CONCRETE 17 " D E P T H BASE 6" ROCK BASE (3/4" GRAVEL) Ø 2 . 8 6 4 " Ø 3.164" 0. 3 0 0 " TYPICAL CATV 2'x3' VAULT DETAIL TYPICAL CATV PEDESTAL DETAIL CONDUIT DETAIL 6' 3'2' 4' 3" HDPE MIN. 36" EXIST. GRADESEND BORE PIT RECEIVE BORE PIT 3" CONDUIT FIBER OPTIC CABLE TRACER WIRE 3" HDPE FIBER OPTIC CABLE 3/8" TRACER WIRE 3" CONDUIT 3" CONDUIT TYPICAL DIRECTIONAL BORE DETAIL TRACER WIRE DETAIL INTERDUCT DETAIL EXISTING GRADE HORIZONTAL SCALE: 1" = 40' VERTICAL SCALE: 1" = 4' 36" - 48" COVER C/ L O F S T R E E T 12" CLEARANCE PLACE 1-3" CONDUIT AT 36" - 48" DEPTH EXISTING UTILITIES (NOTE: DEPTH MAY VARY FOR DIFFERENT UTILITIES) TYPICAL UTILITY CLEARANCE (PROTECT IN PLACE AT ALL EX. UTILITY CROSSINGS) N.T.S. S/W D/W PH R/W EX C/L EOP CF ABBREVIATIONS V PED · · · · · · N 5376262 – ➢ ➢ ➢ ➢ ➢ ➢ ➢ ➢ UTILITY PLAN GENERAL NOTES:REV 03-13-2024 WORK DURATION: ·05 DAYS FOR EXCAVATION / BORE / TRENCH WORK ·03 DAY FOR RESTORATION ·02 DAY TO PULL CABLE ·10 DAYS OF TRAFFIC CONTROL SET UP ·TOTAL # OF WORK DAYS: 10 SCOPE OF WORK: ·BORE / TRENCH TO INSTALL CONDUITS FOR CHARTER SPECTRUM (1,264 ft.). ·SET NEW CHARTER VAULTS (2). ·SET BORE PITS (8). ·REMOVE & REPLACE ASPHALT (72 sq.ft). ·REMOVE & REPLACE CONCRETE SIDEWALK PANEL (42 sq.ft). EXCAVATION AREA EX. CONDUIT EXCAVATION AREA EXCAVATION AREA TEMEC U L A P K W Y A P I S R D A P I S R D WOLF S T O R E R D M E A D O W S CLEARED BY CITY OF TEMECULA PUBLIC WORKS Tricia.ortega 07/23/2024 07/23/2024 07/23/2024 07/23/20 V V V EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP TEMEC U L A P K W Y TEMEC U L A P K W Y 71.00' 71.00' 3+00 4+00 5+00 6+00 7+00 3 + 9 7 6 + 7 1 TV TV TV TV TV TV ROD & ROPE THROUGH EXISTING CHARTER CONDUIT 280'2'x3' EX.V1-D 2'x3' EX.V2-C 2'x3' EX.V3-D 2'x4' BP1-D 1 | 3" 322' BORE BP1 TO BP2 GREENB E L T GREENB E L T GREENB E L T GREEN B E L T GREENB E L T GREENB E L T 1 | 3" 6' TRENCH-D EX.V3 TO BP1 16' ROW 16' ROW ELECTRIC LINE GAS LINE TELEPHONE LINE WATER LINE CATV LINE TRAFFIC SIGNAL LINE SEWER LINE STORM DRAIN LINE FIBER OPTIC LINE PETROLUEM LINE STREET LIGHTS INDUSTRIAL WASTE OIL LINE FUEL LINE RECLAIMED WATER PROPOSED CONSTRUCTION PROPOSED HDD BORE / CONDUIT INSTALLATION PROPOSED TRENCH / CONDUIT INSTALLATION PROPOSED POTHOLE (2'x2') PROPOSED EXIT / MISSILE BORE PIT (2'x4') PROPOSED BORE PIT (3'x6') CATV PROPOSED NEW CATV VAULT (2'x3') UTILITY / LINE LEGEND EDGE OF PAVEMENT CURB FACE RIGHT OF WAY (CITY) CENTERLINE (C/L) DESIGN ORIENTATIONREVISIONS REV#DATE DESCRIPTION 00 40'80' #-C #-A #-D _____ IN CONCRETE _____ IN ASPHALT _____ IN DIRT/GREENBELT CALLOUT ABBREVIATIONS TREN (TRENCH TO INSTALL 3" UG CONDUIT) BORE (BORE TO INSTALL 3" UG CONDUIT) BP (BORE PIT 3'x6') MBP (MISSILE BORE PIT 2'x4') PH (POTHOLE 2'x2') V (CATV VAULT) | P (CATV PEDESTAL) R&R (REMOVE & REPLACE) ##' ##- CALLOUT DETAILS XX-X ##' CONSTRUCTION TOTALS (TOTAL AMOUNTS FOR ENTIRE ROUTE) CONSTRUCTION SHEET OF JOB NOTES: 1.The existence and location of any underground utility pipes or structures was obtained by a search of the available records and field conditions. Additional underground facilities may exist, or the location of the facilities may differ from the locations shown on these plans. The contractor shall, at his own expense, determine the exact location of all such underground facilities prior to commencement of any work or any action which may damage such facilities or interfere with their continuous and proper operation. 2.All plans must be checked and approved by the governmental agency, or agencies, having jurisdiction over the roadways shown on this plan being put into effect. All plans are intended to conform to the Manual on Uniform Traffic Control Devices. The customer/contractor is responsible for ascertaining addition agency requirements for work hours allowed, noise abatement, and other rules and regulations. 3.The temporary traffic controls must be installed per the agency approved plan to be effective. Field changes, other than minor adjustment, must be authorized in writing be a representative of the governmental agency, or agencies, having jurisdiction over the roadway. 4.Plan implementation and device placement should be performed by experienced and trained personnel. 5.Temporary traffic control must be monitored and maintained by the customer/contractor to remain effective. Monitoring and maintenance frequency is dictated by field conditions, but not less than daily. 6.Optimum Inc. has no control over, or responsibility for traffic control plan implementation and inspections performed by others. Users agree to indemnify Optimum Inc. for claims made regarding failure to install, maintain or remove controls per approved traffic control plans. TP TELEPHONE PEDESTAL T TELEPHONE VAULT EV ELECTRIC VAULT CATV VAULT IV IRRIGATION VAULT UTILITY POLE FIRE HYDRANT UNDERGROUND VALVE MAN HOLE F M SL STREET LIGHT VAULT TS TRAFFIC SIGNAL VAULT WV WATER VAULT CATV PEDESTALABOVE GROUND VALVE GV GAS VAULT FO FIBER OPTIC VAULT CV COMMUNICATIONS VAULT T EXISTING OBJECTS S/W D/W PH R/W EX C/L EOP CF ABBREVIATIONS V PED · · · · · · PTIMUM, INC. GENERAL ENGINEERING CONTRACTORS OFFICE: (909) 990-0767 CSLB#: 817291 | CLASS: C-7 A C31 17890 VALLEY BLVD BLOOMINGTON CA 7337 CENTRAL AVE RIVERSIDE CA.92504 OFFICE: (833) 267-6097 32413 TEMECULA PKWY TEMECULA CA 92592 - JESUS SAMANIEGO HHS 7/3/2024 - A.LOAYZA CITY OF TEMECULA PO#: PENDING PRISM#: CHARTER PUBLIC WORKS DEPARTMENT PRISM#: 5376262 N 5376262 S W E 2 6 EOP EOP EOP EOP EOP EO P E O P E O P CF CF CF CF CF CF C F C F CF CF CF CF CF CFCF EOP EOP EOP EOP EOP EO P CF CF CF EO P EOP EOP E O P E O P E O P EOP EOP C F C F C FCF CF CF R / W R / W TEMEC U L A P K W Y A P I S R D STA. 0+00 @ C/L MEADOWS PKWY 1+00 0 + 7 3 2+00 3+00 PED TEMEC U L A P K W Y 2'x3' EX.PED-D 2'x4' BP2-C 42 sq.ft R&R-C 1 | 3" 322' BORE BP1 TO BP2 GREENB E L T GREENB E L T 1 | 3" 4' TRENCH-C BP2 TO EX.PED 2'x4' BP3-D 2'x4' BP4-D 4'x6' BP5-A 1 | 3" 50' BORE BP2 TO BP3 1 | 3" 83' BORE BP3 TO BP4 1 | 3" 8' BORE BP4 TO BP5 1 + 0 0 0+92 1+75 16' ROW 7' ROW 7' ROW 24 sq.ft R&R-A ELECTRIC LINE GAS LINE TELEPHONE LINE WATER LINE CATV LINE TRAFFIC SIGNAL LINE SEWER LINE STORM DRAIN LINE FIBER OPTIC LINE PETROLUEM LINE STREET LIGHTS INDUSTRIAL WASTE OIL LINE FUEL LINE RECLAIMED WATER PROPOSED CONSTRUCTION PROPOSED HDD BORE / CONDUIT INSTALLATION PROPOSED TRENCH / CONDUIT INSTALLATION PROPOSED POTHOLE (2'x2') PROPOSED EXIT / MISSILE BORE PIT (2'x4') PROPOSED BORE PIT (3'x6') CATV PROPOSED NEW CATV VAULT (2'x3') UTILITY / LINE LEGEND EDGE OF PAVEMENT CURB FACE RIGHT OF WAY (CITY) CENTERLINE (C/L) DESIGN ORIENTATIONREVISIONS REV#DATE DESCRIPTION 00 40'80' #-C #-A #-D _____ IN CONCRETE _____ IN ASPHALT _____ IN DIRT/GREENBELT CALLOUT ABBREVIATIONS TREN (TRENCH TO INSTALL 3" UG CONDUIT) BORE (BORE TO INSTALL 3" UG CONDUIT) BP (BORE PIT 3'x6') MBP (MISSILE BORE PIT 2'x4') PH (POTHOLE 2'x2') V (CATV VAULT) | P (CATV PEDESTAL) R&R (REMOVE & REPLACE) ##' ##- CALLOUT DETAILS XX-X ##' CONSTRUCTION TOTALS (TOTAL AMOUNTS FOR ENTIRE ROUTE) CONSTRUCTION SHEET OF JOB NOTES: 1.The existence and location of any underground utility pipes or structures was obtained by a search of the available records and field conditions. Additional underground facilities may exist, or the location of the facilities may differ from the locations shown on these plans. The contractor shall, at his own expense, determine the exact location of all such underground facilities prior to commencement of any work or any action which may damage such facilities or interfere with their continuous and proper operation. 2.All plans must be checked and approved by the governmental agency, or agencies, having jurisdiction over the roadways shown on this plan being put into effect. All plans are intended to conform to the Manual on Uniform Traffic Control Devices. The customer/contractor is responsible for ascertaining addition agency requirements for work hours allowed, noise abatement, and other rules and regulations. 3.The temporary traffic controls must be installed per the agency approved plan to be effective. Field changes, other than minor adjustment, must be authorized in writing be a representative of the governmental agency, or agencies, having jurisdiction over the roadway. 4.Plan implementation and device placement should be performed by experienced and trained personnel. 5.Temporary traffic control must be monitored and maintained by the customer/contractor to remain effective. Monitoring and maintenance frequency is dictated by field conditions, but not less than daily. 6.Optimum Inc. has no control over, or responsibility for traffic control plan implementation and inspections performed by others. Users agree to indemnify Optimum Inc. for claims made regarding failure to install, maintain or remove controls per approved traffic control plans. TP TELEPHONE PEDESTAL T TELEPHONE VAULT EV ELECTRIC VAULT CATV VAULT IV IRRIGATION VAULT UTILITY POLE FIRE HYDRANT UNDERGROUND VALVE MAN HOLE F M SL STREET LIGHT VAULT TS TRAFFIC SIGNAL VAULT WV WATER VAULT CATV PEDESTALABOVE GROUND VALVE GV GAS VAULT FO FIBER OPTIC VAULT CV COMMUNICATIONS VAULT T EXISTING OBJECTS S/W D/W PH R/W EX C/L EOP CF ABBREVIATIONS V PED · · · · · · PTIMUM, INC. GENERAL ENGINEERING CONTRACTORS OFFICE: (909) 990-0767 CSLB#: 817291 | CLASS: C-7 A C31 17890 VALLEY BLVD BLOOMINGTON CA 7337 CENTRAL AVE RIVERSIDE CA.92504 OFFICE: (833) 267-6097 32413 TEMECULA PKWY TEMECULA CA 92592 - JESUS SAMANIEGO HHS 7/3/2024 - A.LOAYZA CITY OF TEMECULA PO#: PENDING PRISM#: CHARTER PUBLIC WORKS DEPARTMENT PRISM#: 5376262 N 5376262 S W E 3 6 E O P E O P E O P E O P E O P E O P C F E O P E O P E O P E O P E O P E O P C F C F C F R / W R / W R / W R / W R / W A P I S R D 2'x4' BP4-D 4'x6' BP6-A 1 | 3" 250' BORE BP5 TO BP6 1 | 3" 137' BORE BP6 TO BP7 2 + 0 0 3 + 0 0 4 + 0 0 5 + 0 0 1+75 4+26 7' ROW 24 sq.ft R&R-A 24 sq.ft R&R-A ELECTRIC LINE GAS LINE TELEPHONE LINE WATER LINE CATV LINE TRAFFIC SIGNAL LINE SEWER LINE STORM DRAIN LINE FIBER OPTIC LINE PETROLUEM LINE STREET LIGHTS INDUSTRIAL WASTE OIL LINE FUEL LINE RECLAIMED WATER PROPOSED CONSTRUCTION PROPOSED HDD BORE / CONDUIT INSTALLATION PROPOSED TRENCH / CONDUIT INSTALLATION PROPOSED POTHOLE (2'x2') PROPOSED EXIT / MISSILE BORE PIT (2'x4') PROPOSED BORE PIT (3'x6') CATV PROPOSED NEW CATV VAULT (2'x3') UTILITY / LINE LEGEND EDGE OF PAVEMENT CURB FACE RIGHT OF WAY (CITY) CENTERLINE (C/L) DESIGN ORIENTATIONREVISIONS REV#DATE DESCRIPTION 00 40'80' #-C #-A #-D _____ IN CONCRETE _____ IN ASPHALT _____ IN DIRT/GREENBELT CALLOUT ABBREVIATIONS TREN (TRENCH TO INSTALL 3" UG CONDUIT) BORE (BORE TO INSTALL 3" UG CONDUIT) BP (BORE PIT 3'x6') MBP (MISSILE BORE PIT 2'x4') PH (POTHOLE 2'x2') V (CATV VAULT) | P (CATV PEDESTAL) R&R (REMOVE & REPLACE) ##' ##- CALLOUT DETAILS XX-X ##' CONSTRUCTION TOTALS (TOTAL AMOUNTS FOR ENTIRE ROUTE) CONSTRUCTION SHEET OF JOB NOTES: 1.The existence and location of any underground utility pipes or structures was obtained by a search of the available records and field conditions. Additional underground facilities may exist, or the location of the facilities may differ from the locations shown on these plans. The contractor shall, at his own expense, determine the exact location of all such underground facilities prior to commencement of any work or any action which may damage such facilities or interfere with their continuous and proper operation. 2.All plans must be checked and approved by the governmental agency, or agencies, having jurisdiction over the roadways shown on this plan being put into effect. All plans are intended to conform to the Manual on Uniform Traffic Control Devices. The customer/contractor is responsible for ascertaining addition agency requirements for work hours allowed, noise abatement, and other rules and regulations. 3.The temporary traffic controls must be installed per the agency approved plan to be effective. Field changes, other than minor adjustment, must be authorized in writing be a representative of the governmental agency, or agencies, having jurisdiction over the roadway. 4.Plan implementation and device placement should be performed by experienced and trained personnel. 5.Temporary traffic control must be monitored and maintained by the customer/contractor to remain effective. Monitoring and maintenance frequency is dictated by field conditions, but not less than daily. 6.Optimum Inc. has no control over, or responsibility for traffic control plan implementation and inspections performed by others. Users agree to indemnify Optimum Inc. for claims made regarding failure to install, maintain or remove controls per approved traffic control plans. TP TELEPHONE PEDESTAL T TELEPHONE VAULT EV ELECTRIC VAULT CATV VAULT IV IRRIGATION VAULT UTILITY POLE FIRE HYDRANT UNDERGROUND VALVE MAN HOLE F M SL STREET LIGHT VAULT TS TRAFFIC SIGNAL VAULT WV WATER VAULT CATV PEDESTALABOVE GROUND VALVE GV GAS VAULT FO FIBER OPTIC VAULT CV COMMUNICATIONS VAULT T EXISTING OBJECTS S/W D/W PH R/W EX C/L EOP CF ABBREVIATIONS V PED · · · · · · PTIMUM, INC. GENERAL ENGINEERING CONTRACTORS OFFICE: (909) 990-0767 CSLB#: 817291 | CLASS: C-7 A C31 17890 VALLEY BLVD BLOOMINGTON CA 7337 CENTRAL AVE RIVERSIDE CA.92504 OFFICE: (833) 267-6097 32413 TEMECULA PKWY TEMECULA CA 92592 - JESUS SAMANIEGO HHS 7/3/2024 - A.LOAYZA CITY OF TEMECULA PO#: PENDING PRISM#: CHARTER PUBLIC WORKS DEPARTMENT PRISM#: 5376262 N 5376262 S W E 4 6 E O P E O P E O P E O P E O P E O P C F C F C F C F C F E O P E O P E O P E O P E O P C F C F C F C F R / W R / W R / W R / W A P I S R D 4'x6' BP7-A CA T V 2'x3' V4-D V6-D 1 | 3" 137' BP6 TO BP7 1 | 3" 252' BORE V4 TO V5 1 | 3" 7' BORE BP7 TO V4 5 + 0 0 6 + 0 0 7 + 0 0 5+64 6' ROW 24 sq.ft R&R-A ELECTRIC LINE GAS LINE TELEPHONE LINE WATER LINE CATV LINE TRAFFIC SIGNAL LINE SEWER LINE STORM DRAIN LINE FIBER OPTIC LINE PETROLUEM LINE STREET LIGHTS INDUSTRIAL WASTE OIL LINE FUEL LINE RECLAIMED WATER PROPOSED CONSTRUCTION PROPOSED HDD BORE / CONDUIT INSTALLATION PROPOSED TRENCH / CONDUIT INSTALLATION PROPOSED POTHOLE (2'x2') PROPOSED EXIT / MISSILE BORE PIT (2'x4') PROPOSED BORE PIT (3'x6') CATV PROPOSED NEW CATV VAULT (2'x3') UTILITY / LINE LEGEND EDGE OF PAVEMENT CURB FACE RIGHT OF WAY (CITY) CENTERLINE (C/L) DESIGN ORIENTATIONREVISIONS REV#DATE DESCRIPTION 00 40'80' #-C #-A #-D _____ IN CONCRETE _____ IN ASPHALT _____ IN DIRT/GREENBELT CALLOUT ABBREVIATIONS TREN (TRENCH TO INSTALL 3" UG CONDUIT) BORE (BORE TO INSTALL 3" UG CONDUIT) BP (BORE PIT 3'x6') MBP (MISSILE BORE PIT 2'x4') PH (POTHOLE 2'x2') V (CATV VAULT) | P (CATV PEDESTAL) R&R (REMOVE & REPLACE) ##' ##- CALLOUT DETAILS XX-X ##' CONSTRUCTION TOTALS (TOTAL AMOUNTS FOR ENTIRE ROUTE) CONSTRUCTION SHEET OF JOB NOTES: 1.The existence and location of any underground utility pipes or structures was obtained by a search of the available records and field conditions. Additional underground facilities may exist, or the location of the facilities may differ from the locations shown on these plans. The contractor shall, at his own expense, determine the exact location of all such underground facilities prior to commencement of any work or any action which may damage such facilities or interfere with their continuous and proper operation. 2.All plans must be checked and approved by the governmental agency, or agencies, having jurisdiction over the roadways shown on this plan being put into effect. All plans are intended to conform to the Manual on Uniform Traffic Control Devices. The customer/contractor is responsible for ascertaining addition agency requirements for work hours allowed, noise abatement, and other rules and regulations. 3.The temporary traffic controls must be installed per the agency approved plan to be effective. Field changes, other than minor adjustment, must be authorized in writing be a representative of the governmental agency, or agencies, having jurisdiction over the roadway. 4.Plan implementation and device placement should be performed by experienced and trained personnel. 5.Temporary traffic control must be monitored and maintained by the customer/contractor to remain effective. Monitoring and maintenance frequency is dictated by field conditions, but not less than daily. 6.Optimum Inc. has no control over, or responsibility for traffic control plan implementation and inspections performed by others. Users agree to indemnify Optimum Inc. for claims made regarding failure to install, maintain or remove controls per approved traffic control plans. TP TELEPHONE PEDESTAL T TELEPHONE VAULT EV ELECTRIC VAULT CATV VAULT IV IRRIGATION VAULT UTILITY POLE FIRE HYDRANT UNDERGROUND VALVE MAN HOLE F M SL STREET LIGHT VAULT TS TRAFFIC SIGNAL VAULT WV WATER VAULT CATV PEDESTALABOVE GROUND VALVE GV GAS VAULT FO FIBER OPTIC VAULT CV COMMUNICATIONS VAULT T EXISTING OBJECTS S/W D/W PH R/W EX C/L EOP CF ABBREVIATIONS V PED · · · · · · PTIMUM, INC. GENERAL ENGINEERING CONTRACTORS OFFICE: (909) 990-0767 CSLB#: 817291 | CLASS: C-7 A C31 17890 VALLEY BLVD BLOOMINGTON CA 7337 CENTRAL AVE RIVERSIDE CA.92504 OFFICE: (833) 267-6097 32413 TEMECULA PKWY TEMECULA CA 92592 - JESUS SAMANIEGO HHS 7/3/2024 - A.LOAYZA CITY OF TEMECULA PO#: PENDING PRISM#: CHARTER PUBLIC WORKS DEPARTMENT PRISM#: 5376262 N 5376262 S W E 5 6 E O P E O P E O P EO P EOP EOP C F C F C F CF CF CF EOP EOP EOP E O P E O P E O P C F C F C F C F CF CF CF R/W R/W R / W R / W A P I S R D WOLF S T O R E R D C A T V CATV 2'x3' V5-D 2'x3' V6-D 1 | 3" 252' BORE V4 TO V5 1 | 3" 22' BORE V5 TO BP8 4'x6' BP8-D 1 | 3" 123' BORE BP8 TO V6 7 + 0 0 8 + 0 0 9+00 10+008+19 1 0 + 2 5 6' ROW ELECTRIC LINE GAS LINE TELEPHONE LINE WATER LINE CATV LINE TRAFFIC SIGNAL LINE SEWER LINE STORM DRAIN LINE FIBER OPTIC LINE PETROLUEM LINE STREET LIGHTS INDUSTRIAL WASTE OIL LINE FUEL LINE RECLAIMED WATER PROPOSED CONSTRUCTION PROPOSED HDD BORE / CONDUIT INSTALLATION PROPOSED TRENCH / CONDUIT INSTALLATION PROPOSED POTHOLE (2'x2') PROPOSED EXIT / MISSILE BORE PIT (2'x4') PROPOSED BORE PIT (3'x6') CATV PROPOSED NEW CATV VAULT (2'x3') UTILITY / LINE LEGEND EDGE OF PAVEMENT CURB FACE RIGHT OF WAY (CITY) CENTERLINE (C/L) DESIGN ORIENTATIONREVISIONS REV#DATE DESCRIPTION 00 40'80' #-C #-A #-D _____ IN CONCRETE _____ IN ASPHALT _____ IN DIRT/GREENBELT CALLOUT ABBREVIATIONS TREN (TRENCH TO INSTALL 3" UG CONDUIT) BORE (BORE TO INSTALL 3" UG CONDUIT) BP (BORE PIT 3'x6') MBP (MISSILE BORE PIT 2'x4') PH (POTHOLE 2'x2') V (CATV VAULT) | P (CATV PEDESTAL) R&R (REMOVE & REPLACE) ##' ##- CALLOUT DETAILS XX-X ##' CONSTRUCTION TOTALS (TOTAL AMOUNTS FOR ENTIRE ROUTE) CONSTRUCTION SHEET OF JOB NOTES: 1.The existence and location of any underground utility pipes or structures was obtained by a search of the available records and field conditions. Additional underground facilities may exist, or the location of the facilities may differ from the locations shown on these plans. The contractor shall, at his own expense, determine the exact location of all such underground facilities prior to commencement of any work or any action which may damage such facilities or interfere with their continuous and proper operation. 2.All plans must be checked and approved by the governmental agency, or agencies, having jurisdiction over the roadways shown on this plan being put into effect. All plans are intended to conform to the Manual on Uniform Traffic Control Devices. The customer/contractor is responsible for ascertaining addition agency requirements for work hours allowed, noise abatement, and other rules and regulations. 3.The temporary traffic controls must be installed per the agency approved plan to be effective. Field changes, other than minor adjustment, must be authorized in writing be a representative of the governmental agency, or agencies, having jurisdiction over the roadway. 4.Plan implementation and device placement should be performed by experienced and trained personnel. 5.Temporary traffic control must be monitored and maintained by the customer/contractor to remain effective. Monitoring and maintenance frequency is dictated by field conditions, but not less than daily. 6.Optimum Inc. has no control over, or responsibility for traffic control plan implementation and inspections performed by others. Users agree to indemnify Optimum Inc. for claims made regarding failure to install, maintain or remove controls per approved traffic control plans. TP TELEPHONE PEDESTAL T TELEPHONE VAULT EV ELECTRIC VAULT CATV VAULT IV IRRIGATION VAULT UTILITY POLE FIRE HYDRANT UNDERGROUND VALVE MAN HOLE F M SL STREET LIGHT VAULT TS TRAFFIC SIGNAL VAULT WV WATER VAULT CATV PEDESTALABOVE GROUND VALVE GV GAS VAULT FO FIBER OPTIC VAULT CV COMMUNICATIONS VAULT T EXISTING OBJECTS S/W D/W PH R/W EX C/L EOP CF ABBREVIATIONS V PED · · · · · · PTIMUM, INC. GENERAL ENGINEERING CONTRACTORS OFFICE: (909) 990-0767 CSLB#: 817291 | CLASS: C-7 A C31 17890 VALLEY BLVD BLOOMINGTON CA 7337 CENTRAL AVE RIVERSIDE CA.92504 OFFICE: (833) 267-6097 32413 TEMECULA PKWY TEMECULA CA 92592 - JESUS SAMANIEGO HHS 7/3/2024 - A.LOAYZA CITY OF TEMECULA PO#: PENDING PRISM#: CHARTER PUBLIC WORKS DEPARTMENT PRISM#: 5376262 N 5376262 S W E 6 6 ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? INSR ADDL SUBR LTR INSD WVD DATE (MM/DD/YYYY) PRODUCER CONTACT NAME: FAXPHONE (A/C, No):(A/C, No, Ext): E-MAIL ADDRESS: INSURER A : INSURED INSURER B : INSURER C : INSURER D : INSURER E : INSURER F : POLICY NUMBER POLICY EFF POLICY EXPTYPE OF INSURANCE LIMITS(MM/DD/YYYY)(MM/DD/YYYY) AUTOMOBILE LIABILITY UMBRELLA LIAB EXCESS LIAB WORKERS COMPENSATION AND EMPLOYERS' LIABILITY DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) AUTHORIZED REPRESENTATIVE EACH OCCURRENCE $ DAMAGE TO RENTED CLAIMS-MADE OCCUR $PREMISES (Ea occurrence) MED EXP (Any one person)$ PERSONAL & ADV INJURY $ GEN'L AGGREGATE LIMIT APPLIES PER:GENERAL AGGREGATE $ PRO-POLICY LOC PRODUCTS - COMP/OP AGG $JECT OTHER:$ COMBINED SINGLE LIMIT $(Ea accident) ANY AUTO BODILY INJURY (Per person)$ OWNED SCHEDULED BODILY INJURY (Per accident)$AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $AUTOS ONLY AUTOS ONLY (Per accident) $ OCCUR EACH OCCURRENCE $ CLAIMS-MADE AGGREGATE $ DED RETENTION $$ PER OTH- STATUTE ER E.L. EACH ACCIDENT $ E.L. DISEASE - EA EMPLOYEE $ If yes, describe under E.L. DISEASE - POLICY LIMIT $DESCRIPTION OF OPERATIONS below INSURER(S) AFFORDING COVERAGE NAIC # COMMERCIAL GENERAL LIABILITY Y / N N / A (Mandatory in NH) SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). COVERAGES CERTIFICATE NUMBER:REVISION NUMBER: CERTIFICATE HOLDER CANCELLATION © 1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORDACORD 25 (2016/03) CERTIFICATE OF LIABILITY INSURANCE Lockton Companies 444 W. 47th Street, Suite 900 Kansas City MO 64112-1906 (816) 960-9000 kcasu@lockton.com HHS CONSTRUCTION, LLC 2042 S. GROVE AVE. ONTARIO CA 91761 - Hartford Casualty Insurance Company 29424 Hartford Fire Insurance Company 19682 Twin City Fire Insurance Company 29459 X X 1,000,000 300,000 10,000 1,000,000 2,000,000 2,000,000 X X X X $1,000,000 XXXXXXX XXXXXXX XXXXXXX XXXXXXX X X X 10,000 10,000,000 10,000,000 XXXXXXX XXXXXXX XXXXXXX XXXXXXX C 37 UENOL5831 9/30/2023 9/30/2024 A 37 ECS0L5825 9/30/2023 9/30/2024 B 37XHUOL5832 9/30/2023 9/30/2024 NOT APPLICABLE 9/30/2024 1451971 N N N N N N 8/31/2023 16271358 16271358 XXXXXXX CITY OF TEMECULA 41000 MAIN STREET TEMECULA CA 92590 RE: ALL OPERATIONS PERFORMED BY THE NAMED INSURED DURING THE CURRENT POLICY PERIOD. EXCEPT 10 DAYS NOTICE OF CANCELLATION OF NON-PAYMENT OF PREMIUM; SHOULD THIS POLICY BE CANCELLED BEFORE THE EXPIRATION DATE, LOCKTON COMPANIES WILL MAIL 30 (THIRTY) DAYS WRITTEN NOTICE TO THOSE CERTIFICATE HOLDERS WHICH REQUIRE SUCH ACTION PER CONTRACT OR AGREEMENT. X X Land Development Encroachment Permit 41000 Main Street Temecula, Ca 92590 Phone: 951-694-6444 www.temeculaca.gov R:\LAND DEVELOPMENT DIVISION\Forms\Permit Applications\Word\Encroachment Permit App.docx Page 1 of 2 Revised: 06/16/2020 APPLICATION INFORMATION PERMIT NO.: Type of Encroachment: Street/Storm Drain Sewer/Water Utility Trenching Signing & Striping Traffic Signal Miscellaneous (SPECIFY BELOW) The undersigned hereby applies to excavate, construct and otherwise encroach on City street right-of-way, as follows: Name(s) of street(s) and/or street address: Utility Work Order #: Start Date: End Date: In consideration of granting this application, all applicants including utility companies hereby agree to: 1.If applicable, submit a set of Construction Drawings, Traffic Control Plans, proof of City Business License for all parties involved, proof of Contractor’s License along with this application at the time of submittal. See the Traffic Control Plan Checklist for details. 2.Indemnify, defend and save the City, its authorized agents, officers, representatives and employees, harmless from and against any and all penalties, liabilities or loss resulting from claims or court action and arising out of any accident, loss or damage to persons or property happening or occurring as a proximate result of any work undertaken under the permit granted pursuant to this application. (See below for specific liability insurance requirements.) 3.Remove/relocate any encroachment installed/maintained under this permit, upon written notice from the City Engineer. 4.Notify the Land Development Inspection Division via email at LDInspections@temeculaca.gov at least two (2) working days prior to commencing construction. Hold a pre-construction meeting prior to the start of construction. The developer/general contractor must be present for the timely request of inspections. 5.Comply with the Standard Specifications, most current Improvement Standard Drawings for Public Works Construction, City of Temecula Municipal Code Chapters 13.04 and 18.12, terms and conditions of the permit and all applicable rules and regulations for the City of Temecula and other public agencies having jurisdiction. LIABILITY INSURANCE REQUIREMENTS PROVIDE PROOF OF INSURANCE COVERAGE MEETING THE REQURIEMENTS STATED BELOW OR A CITY ATTORNEY APPROVED EQUIVALENT WITH THE CITY NAMED AS ADDITIONAL INSURED. IN THE EVENT THAT THE INSURANCE IS PROVIDED BY THE CONTRACTOR, THE CITY AND THE OWNER/DEVELOPER MUST BE NAMED AS ADDITIONAL INSURED. THIS REQUREMENT SHALL BE MET BY EITHER THE APPLICANT (DEVELOPER, OWNER, PUBLIC UTILITY AGENCY OR FRANCHISE) OR BY THE CONTRACTOR PERFORMING THE SUBJECT WORK, PRIOR TO BEGININNG ANY WORK PROPOSED UNDER THE SUBJECT ENCROACHMENT PERMIT. · BORE / TRENCH TO INSTALL CONDUITS FOR CHARTER SPECTRUM (1,264 ft.). · SET NEW CHARTER VAULTS (2). · SET BORE PITS (8). · REMOVE & REPLACE ASPHALT (72 sq.ft). · REMOVE & REPLACE CONCRETE SIDEWALK PANEL (42 sq.ft). 32413 TEMECULA PKWY, TEMECULA CA 92592 P_5376262 06-24-2024 07-03-2023 LD24-2444 CLEARED BY CITY OF TEMECULA PUBLIC WORKS Tricia.ortega 06/26/2024 06/26/2024 06/26/2024 06/26/20 Land Development Encroachment Permit 41000 Main Street Temecula, Ca 92590 Phone: 951-694-6444 www.temeculaca.gov R:\LAND DEVELOPMENT DIVISION\Forms\Permit Applications\Word\Encroachment Permit App.docx Page 2 of 2 Revised: 06/16/2020 Proof of coverage shall be by certificate (Accord or equivalent) naming the City of Temecula as certificate holder and the minimum limits of insurance coverage shall be as follows: a.General Liability: One million dollars ($1,000,000) per occurrence for bodily injury, personal injury and property damage. If Commercial General Liability Insurance or other form with a general aggregate limit is used, either the general aggregate lim it shall apply separately to this project/location or the general aggregate limit shall be twice the required occurrence limit. b.Automobile Liability: One million dollars ($1,000,000) per accident for bodily injury and property damage. c.Worker’s Compensation as required by the State of California; Employer’s Liability: One million dollars ($1,000,000) per accident for bodily injury or disease. d.Course of Construction: Completed value of the project. There is a limited exception to this requirement. Owners of single family homes doing work on the home’s driveway approac h located in the public right-of-way, may use their homeowners insurance with public liability and property damage coverage in at least the following minimum limits and which will name the City of Temecula as an additional insured for the duration of the encroachment permit: BODILY INJURY $250,000.00 EACH PERSON $500,000.00 EACH OCCURANCE $500,000.00 AGGREGATE PRODUCTS AND COMPLETED OPERATIONS PROPERTY DAMAGE $100,000.00 EACH OCCURANCE $250,000.00 AGGREGATE PRODUCTS AND COMPLETED OPERATIONS A combined single limit homeowner’s policy with aggregate limits in the amount of $1,000,000.00 will be considered equivalent to the required minimum limits. Homeowners: a copy of the required homeowners insurance and a Certificate of Insurance showing the City named as an additional insured shall be attached to the application. The undersigned applicant and/or contractor states that they have read and agrees to meet all the conditions on this application, including provisions of required liability insurance or a City Attorney approved equivalent, and acknowledges that this application will be made a part of the encroachment permit. APPLICANT’S INFORMATION (THIS SECTION MUST BE COMPLETED) Company Name: Mailing Address: Contact: Phone #: E-mail: I hereby warrant and represent to the City that I am authorized to execute this permit application on behalf of the permittee and bind the permittee to the agreements contained herein and any conditions of the permit. Authorized Signature: Date Applied: CONTRACTOR’S INFORMATION Company Name: Mailing Address: Contact: Phone #: 24-HR Emergency #: State Contractor’s License #: Class: City Business License #: 06-06-2024 Charter Spectrum Stephen Wade (818) 427-4947 Stephan.wade1@charter.com 7337 Central Ave Riverside, CA 92504 HHS CONSTRUCTION 2042 S Grove Ave, Ontario CA 91761 049178818906A,B,C10,C31,C-7 Veronica Barrozo (909) 721-3785 Dave Curry: (909) 376-4938