Loading...
HomeMy WebLinkAboutLD25-0109Permit Number: LD25-0109 LD - Utilities/ Utility Maintenance Issued: 01/07/2025 Expired: 07/06/2025 Job Address: City Wide Pechanga Parkway W/S, 466' S/O Masters Drive Legal Description: City of Temecula - Land Development Division 41000 Main Street - Temecula, CA 92590 Mailing Address: P.O. Box 9033 Temecula, CA 92589-9033 Phone: (951) 308-6395 Fax: (951) 694-6475 Jay Phan 24487 Prelipp Rd 24487 Prielipp Rd Wildomar, CA 92595 (951) 837-1762 Applicant: Southern California Edison (Utility Billing) 24487 Prielipp Wildomar, CA 92595 (951) 440-9074 Contractor: Utility Work Order Number: TD 2292956 Description: SCE - TD 2292956, 466' S/O Master Drive along the W/E/S of Pechanga Parkway. WORK HOURS SHALL BE: MONDAY - FRIDAY, NO HOLIDAYS: 8:30 AM - 3:30 PM. Working Duration: One working day. Proposed Location: 466' S/O Master Drive along the W/E/S of Pechanga Parkway. Proposed Work: Access existing power poles #2351931E and #2351930E, replace faulty indicators as shown on the approved SCE "Construction Plan", LD 25-0109. All facilities shall be installed in accordance with City Standard Drawing 117. Traffic Control shall be in accordance with approved Traffic Control Plan LD25-0109. Permittee shall comply with all applicable Traffic Control General Notes. Safe pedestrian/bicycle traffic and driveway access shall be maintained at all times. Concrete repair shall be in accordance with City Standards and the Greenbook. Trench repair shall be in accordance with City Standard Drawing 407. Final compaction test results shall be provided by a soils engineer. Concrete curbs, walks, gutters, cross gutters and driveway approaches damaged during construction shall be removed from joint to joint and reconstructed in accordance with City Standards and the Greenbook. Page 1 of 2 Permit Number: LD25-0109 LD - Utilities/ Utility Maintenance All disturbed landscaping and other improvements shall be removed/repaired and replaced to the satisfaction of the City Engineer or their designated assignee. Permittee shall contact LDInspections@temeculaca.gov a minimum of two (2) business days prior to any work. Permittee must also request a final inspection to verify completion of project. Permitee Date City Engineer or Authorized Representative Date 01/07/2025 Page 2 of 2 ENDROAD WORKG20-2 ROADWORK AHEADW20-1 LANECLOSEDC30(CA)SINGLE LANE CLOSUREWORKSITE TRAFFIC CONTROL PLAN(RIGHT LANE)W4-2R RIGHT LANECLOSEDAHEAD1W20-5INTERCHANGEABLE WITHC20(CA)SHARETHEROADW11-1/W16-1(USE IF APPLICABLESEE DWG NO. 49FOR DETAILS) S A LEGEND TYPE III BARRICADE W/SIGNTYPE III BARRICADE W/O SIGNTYPE II BARRICADE W/SIGNTYPE II BARRICADE W/O SIGNCHANNELIZING DEVICE - SEE TABLE F FOR SPACINGTRAFFIC CONE WITH CLIP ON SIGNSIGNSIGNALIZED INTERSECTION[FAS] ARROW PANEL (FLASHING ARROW)HIGH LEVEL WARNING DEVICE (FLAGTREE) (OPTIONAL)FLAGGERTANSTANSATTOW AWAY NO STOPPING___TO___(SHOW HOURS)TOW AWAY NO STOPPING ANY TIMEWORK ZONE (ACTIVITY AREA) LIMITSDIRECTION OF TRAFFIC (NOT PAVEMENT MARKING)ROADWAY DESIGNATION INDICATE NORTH WITH A "N"AND AN ARROW POINTNOT TO SCALEN TD2292956 AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF TEMECULA GRANTING TO SOUTHERNCALIFORNIA EDISON COMPANY, ITS SUCCESSORS AND ASSIGN, A FRANCHISE TO USE ANDTO CONSTRUCT AND USE, FOR TRANSMITTING AND DISTRIBUTING ELECTRICITY FOR ANYAND ALL PURPOSES, POLES, WIRES, CONDUITS AND APPURTENANCES, INCLUDINGCOMMUNICATIONS CIRCUITS NECESSARY OR PROPER THEREFOR, IN, ALONG, ACROSS,UPON, OVER AND UNDER THE PUBLIC STREETS, WAYS, ALLEYS, AND PLACES WITHIN THECITY OF TEMECULA.THE CITY COUNCIL OF THE CITY OF TEMECULA DOES NOT HEREBY ORDAIN AS FOLLOWS:ORDINANCE NO. 90-10SECTIONS 8. Grantee of the franchise granted hereby shall indemnify, save,defend and hold harmless the City and any duly established City redevelopmentagency and the respective officers and employees thereof from all liability fordamages proximately resulting from and operations under the franchise. BIKE LANECLOSEDAHEADW20-5 (BIKE)BIKELANECLOSEDSC11 TRAFFIC CONTROL GENERAL NOTES (REV'D. 08/26/2020):1. All traffic control devices shall conform to the latest edition of the California Manual onUniform Traffic Control Devices (California MUTCD) and the Standard Specificationsfor Public Works Construction.2. The City Engineer or his representative has the authority to initiate field changes to assurepublic safety.3. All traffic control devices shall be removed from view w hen not in use.4. Work hours shall be restricted to the period between 8:30 a.m. and 3:30 p.m., Mondaythrough Friday, unless approved otherwise. When night w ork is required, work hours shallbe 9 p.m. to 5 a.m., Sunday through Thursday.5. Trenches must be back filled or plated during non-working hours. Steel plates shall haveasphaltic concrete berm on all edges. All dirt, dust, and debris shall be removed from the streetat end of each day and at the end of the job. The street shall be in drivable condition at all times.6. Pedestrian controls shall be provided as shown on the plans.7. Temporary "NO PARKING" signs w ill be posted 24 hours prior to commencing w ork.8. Access to driveways will be maintained at all times unless other arrangements are made.9. The contractor shall replace within 72 hours, all traffic signal loop detectors damagedduring construction.10. The contractor shall replace within 24 hours, all striping removed or damaged byconstruction work. (Striping may be replaced temporarily w ith tape.)11. All Workers shall be equipped w ith an orange vest (or a reflective vest at night). Allflaggers shall also be equipped with a hard hat, C28 "Stop/Slow" paddle and shall betrained in the proper fundamentals of flagging traffic.12. Any w ork that disturbs normal traffic signal operations shall be coordinated w ith the City ofTemecula’s Traffic Division, 48 hours prior to beginning construction. Contact the City’sTraffic Division at (951) 694 -6411.13. The contractor shall maintain all traffic control devices 24 hours per day and 7 days perweek.14. A minimum of twelve (12) foot travel lanes must be maintained unless otherwiseapproved by the Department of Public Works.15. All night work will require written approval from the Department of Public Works. Laneclosures, road detours, road closures, and traffic signal modifications associated withovernight construction activities will require warning signs be placed at least one week inadvance of starting construction.16. A solar powered flashing arrow board shall be required on all arterial street lane closures.17. If the permit applicant determines that conduit installation will be by the boring machinemethod, the trench patch for the utility observation excavation will be the same as for opentrench excavation method. This will provide a single continuous surface restoration eliminatingthe multiple penetration into the public roadway to all requirements in City Standard # 407(sheet 1 and 2) for trench patch.18. Any w ork that creates an undue safety risk or creates sever congestion may be shut downby City Traffic Engineers, City Field Inspection, or the Police Department.19. Cones and delineators shall have reflectorized sleeves for night w ork.20. If parking is allowed in advanced warning area, advance warning signs shall be mountedon high level devices.APPLICANT IS RESPONSIBLE FOR FULL AND COMPLETE REPRESENTATION OF THEACTUAL ROAD CONDITIONS SHOWN ON THIS PLAN INCLUDING, BUT NOT LIMITED TOEXISITING STRIPING, SIGNING, SIDEWALK, AND BIKE LANES. 12' MIN. FOR E.P.12' MIN. FOR CURB***TO BE DETERMINED BYTHE CITY OF TEMECULA CURB OR E.P. CURB OR E.P.W4-2RW20-1 W20-5 OR C-20 CURB OR E.P. W11-1/W16-1 MERGING TAPER LSEE TABLE BSEE TABLE ASEE TABLE ASEE TABLE A ABC 50' MIN.48 HRS PRIOR TO COMMENCING WORK(IF REQUIRED)INSTALL TEMP. NO PARKING SIGNSFAS350'350'350' G20-2 SPEEDLIMIT45W20-5 SC11 540' TEMECULA PKWY(OPTIONAL) G20-2 BUFFER SPACE100' MIN. ORTABLE D **48 HRS PRIOR TO COMMENCING WORK(IF REQUIRED)INSTALL TEMP. NO PARKING SIGNS WORK AREA C30(CA) 200' W20-1 G20-2 SEE TABLE AA 50' MIN.DOWNSTREAMTAPER50' MIN. /100' MAX. (OPTIONAL)350' 220' 12' MIN. C30(CA)DWY R3-4 (BIKE) R3-4 BIKE TAPER SHEET 1 of 1 MASTERS DR 466' 12' MIN. R3-4 W20-1 W20-1 G20-2 SPEEDLIMIT25 100' w w w.invarion.com SPEED LIMIT 25 SPEED LIMIT 40 Contact USA Dial 811 or 800-422-4133 UNDERGROUND SERVICE ALERT www.digalert.org/contact SINGLE LINE LEGEND