HomeMy WebLinkAboutLD25-0133Permit Number: LD25-0133
LD - Onsite Improvements/ Public Work clearance
Issued: 01/15/2025
Expired: 07/14/2025
Job Address: 30377 Cupeno Ln
Legal Description:
City of Temecula - Land Development Division
41000 Main Street - Temecula, CA 92590
Mailing Address: P.O. Box 9033 Temecula, CA 92589-9033
Phone: (951) 308-6395 Fax: (951) 694-6475
ANY NOTICE OR NOTICES REQUIRED TO BE GIVEN PURSUANT TO THIS PERMIT SHALL BE SERVED
ON THE OTHER PARTY BY FIRST CLASS MAIL, POSTAGE PREPAID, AT THE FOLLOWING ADDRESS:
Carlos Perez
30377 Cupeno Ln
Temecula, CA 92592
Applicant:
Contractor:
Description:
Removing existing Sunroom to add 340 sq.ft to Kitchen area.
Permitee Date
City Engineer or Authorized Representative Date
01/15/2025
Page 1 of 1
City of Temecula
WATER QUALITY MANAGEMENT PLAN (WQMP)
PROJECT NAME & PERMIT N
O:
PROJECT ADDRESS:
PROJECT APN:
PREPARED BY:
Name _________________________________
Address _________________________________
_________________________________
Phone _________________________________
Email _________________________________
PREPARED FOR:
Name _________________________________
Address _________________________________
_________________________________
Phone _________________________________
Email _________________________________
DATE OF WQMP:
APPROVED BY:
APPROVAL DATE:
Carlos Perez-Ramirez
30377 Cupeno Ln Temecula,CA 92592
(626) 780-0228
cprstudiooo@gmail.com
Adolfo Garcia
30377 Cupeno Ln Temecula,CA 92592
(626) 780-0228
cprstudiooo@gmail.com
LD 25-0133
Chris White
1-13-2025
CLEARED BY
CITY OF TEMECULA
PUBLIC WORKS
SUBJECT TO BUILDING DEPARTMENT
APPROVAL
PERMITS ARE REQUIRED
Chris.White 01/13/2025
01/13/2025 01/13/2025
01/13/20
2 WQMP
Applicant's Certification
Project Name:
Permit Number:
APPLICANT'S CERTIFICATION
I have read and understand that the City of Temecula has adopted minimum requirements for
managing urban runoff, including stormwater, from land development activities, as described in
the BMP Design Manual. I certify that this WQMP has been completed to the best of my ability
and accurately reflects the project being proposed and the applicable BMPs proposed to
minimize the potentially negative impacts of this project's land development activities on water
quality. I understand and acknowledge that the plan check review of this WQMP by City staff is
confined to a review and does not relieve me, as the Applicant, of my responsibilities for project
design.
I hereby declare that the design is consistent with the requirements of the City of Temecula
BMP Design Manual, which is a design manual for compliance with local City of Temecula
Stormwater and Urban Runoff Management and Discharge Controls Ordinance (Chapter 8.28
et seq.) and regional MS4 Permit (California Regional Water Quality Control Board San Diego
Region Order No. R9-2013-0001 as amended by R9-2015-0001 and R9-2015-0100)
requirements for stormwater management; as well as the requirements of the City of Temecula
Engineering and Construction Manual (Chapter 18) and the City of Temecula Erosion and
Sediment Control Ordinance (Chapter 18.18 et seq.).
Applicant’s Signature Date:
Print Name
Company
STOP! Before continuing this form review Chapter 1.3 of the BMP Design Manual. If the
project type is listed in Table 1-2, permanent stormwater requirements do not apply to
Preparation Date: ___________Template Date: October 31
st, 2018
1/7/2025
Carlos Perez-Ramirez
CPR Studio
WQMP 3
your project.Write your exempt project category in the space provided below and skip to
Step 3.Do not complete Steps 1,2,or 4 of this WQMP.
Exempt Project category
Template Date:August 1,2016 Preparation Date:[INSERT MO/DY/YR]
4 WQMP
Step 1: Source Control BMP Checklist
Source Control BMPs
All development projects must implement source control BMPs 4.2.1 through 4.2.6 where
applicable and feasible. See Chapter 4.2 and Appendix E of the City BMP Design Manual for
information to implement source control BMPs shown in this checklist.
Answer each category below pursuant to the following:
●"Yes" means the project will implement the source control BMP as described in Chapter
4.2 and/or Appendix E of the City BMP Design Manual. Discussion / justification must be
provided and show locations on the project plans. Select applicable Source Controls in
the Source Control BMP summary on the following page.
●"No" means the BMP is applicable to the project but it is not feasible to implement.
Discussion / justification must be provided.
●"N/A" means the BMP is not applicable at the project site because the project does not
include the feature that is addressed by the BMP (e.g., the project has no outdoor
materials storage areas). Discussion / justification must be provided.
Source Control Requirement Applied?
4.2.1 Prevention of Illicit Discharges into the MS4 ☐Yes ☐No ☐N/A
Discussion / justification:
4.2.2 Storm Drain Stenciling or Signage ☐Yes ☐No ☐N/A
Discussion / justification:
4.2.3 Protect Outdoor Materials Storage Areas from Rainfall,
Run-On, Runoff, and Wind Dispersal
☐Yes ☐No ☐N/A
Discussion / justification:
4.2.4 Protect Materials Stored in Outdoor Work Areas from
Rainfall, Run-On, Runoff, and Wind Dispersal
☐Yes ☐No ☐N/A
Discussion / justification:
4.2.5 Protect Trash Storage Areas from Rainfall, Run-On,
Runoff, and Wind Dispersal
☐Yes ☐No ☐N/A
Discussion / justification:
4.2.6 Additional BMPs Based on Potential Sources of Runoff
Pollutants
☐Yes ☐No ☐N/A
Preparation Date: ___________Template Date: October 31
st, 2018
Roof runs off the existing site drainage
No proposed storm drains
No trash storage areas proposed
WQMP 5
Discussion / justification. Clearly identify which sources of runoff pollutants are discussed:
Source Control BMP Summary
Select all source control BMPs identified for your project in sections 4.2.1 through 4.2.6 above
in the coulumn on the left below. Then select “yes” if the BMP has been implemented and
shown on the project plans, “No” if the BMP has not been implemented, or “N/A” if the BMP
is not applicable to your project.
☐SC-A. On-site storm drain inlets ☐Yes ☐No ☐N/A
☐SC-B. Interior floor drains and elevator shaft sump
pumps
☐Yes ☐No ☐N/A
☐SC-C. Interior parking garages ☐Yes ☐No ☐N/A
☐SC-D1. Need for future indoor & structural pest control ☐Yes ☐No ☐N/A
☐SC-D2. Landscape/outdoor pesticide use ☐Yes ☐No ☐N/A
☐SC-E. Pools, spas, ponds, fountains, and other water
features
☐Yes ☐No ☐N/A
☐SC-F. Food service ☐Yes ☐No ☐N/A
☐SC-G. Refuse areas ☐Yes ☐No ☐N/A
☐SC-H. Industrial processes ☐Yes ☐No ☐N/A
☐SC-I. Outdoor storage of equipment or materials ☐Yes ☐No ☐N/A
☐SC-J. Vehicle and equipment cleaning ☐Yes ☐No ☐N/A
☐SC-K. Vehicle/equipment repair and maintenance ☐Yes ☐No ☐N/A
☐SC-L. Fuel dispensing areas ☐Yes ☐No ☐N/A
☐SC-M. Loading docks ☐Yes ☐No ☐N/A
☐SC-N. Fire sprinkler test water ☐Yes ☐No ☐N/A
☐SC-O. Miscellaneous drain or wash water ☐Yes ☐No ☐N/A
☐SC-P. Plazas, sidewalks, and parking lots ☐Yes ☐No ☐N/A
☐SC-Q. Large trash generating facilities ☐Yes ☐No ☐N/A
☐SC-R. Animal facilities ☐Yes ☐No ☐N/A
☐SC-S. Plant nurseries and garden centers ☐Yes ☐No ☐N/A
☐SC-T. Automotive facilities ☐Yes ☐No ☐N/A
Note: Show all source control measures applied above on the plan sheets.
Template Date: October 31
st, 2018 Preparation Date:___________
No additional BMP's proposed
6 WQMP
Step 2: Site Design BMP Checklist
Site Design BMPs
All development projects must implement site design BMPs SD-A through SD-H where
applicable and feasible. See Chapter 4.3 and Appendix E of the City BMP Design Manual for
information to implement site design BMPs shown in this checklist.
Answer each category below pursuant to the following:
●"Yes" means the project will implement the site design BMP as described in Chapter
4.3 and/or Appendix E of the City BMP Design Manual. Discussion / justification must
be provided and show locations on the project plans.
●"No" means the BMP is applicable to the project but it is not feasible to implement.
Discussion / justification must be provided.
●"N/A" means the BMP is not applicable at the project site because the project does not
include the feature that is addressed by the BMP (e.g., the project site has no existing
natural areas to conserve). Discussion / justification must be provided.
Site Design Requirement Applied?
4.3.1 Maintain Natural Drainage Pathways and Hydrologic
Features
☐Yes ☐No ☐N/A
Discussion / justification:
4.3.2 Conserve Natural Areas, Soils, and Vegetation ☐Yes ☐No ☐N/A
Discussion / justification:
4.3.3 Minimize Impervious Area ☐Yes ☐No ☐N/A
Discussion / justification:
4.3.4 Minimize Soil Compaction ☐Yes ☐No ☐N/A
Discussion / justification:
4.3.5 Impervious Area Dispersion ☐Yes ☐No ☐N/A
Discussion / justification:
4.3.6 Runoff Collection ☐Yes ☐No ☐N/A
Discussion / justification:
4.3.7 Landscaping with Native or Drought Tolerant Species ☐Yes ☐No ☐N/A
Discussion / justification:
Preparation Date: ___________Template Date: October 31
st, 2018
Roof runs off the existing drainage
Project does not affect natural areas, soil or vegetation
Project does not affect site drainage.
Project does not affect existing soil compaction
Project will drain to existing landscape
Project will drain to existing landscape
Project will drain to existing landscape
WQMP 7
4.3.8 Harvesting and Using Precipitation ☐Yes ☐No ☐N/A
Discussion / justification:
Step 3: Construction Stormwater BMP Checklist
Minimum Required Standard Construction Stormwater BMPs
If you answer “Yes” to any of the questions below, your project is subject to Table 1 on the following
page (Minimum Required Standard Construction Stormwater BMPs). As noted in Table 1, please select
at least the minimum number of required BMPs
1, or as many as are feasible for your project. If no BMP
is selected, an explanation must be given in the box provided. The following questions are intended to
aid in determining construction BMP requirements for your project.
Note: All selected BMPs below must be included on the BMP plan incorporated into the
construction plan sets.
1. Will there be soil disturbing activities that will result in exposed soil areas?
(This includes minor grading and trenching.)
Reference Table 1 Items A, B, D, and E
Note: Soil disturbances NOT considered significant include, but are not limited
to, change in use, mechanical/electrical/plumbing activities, signs, temporary
trailers, interior remodeling, and minor tenant improvement.
☐Yes ☐No
2. Will there be asphalt paving, including patching?
Reference Table 1 Items D and F
☐Yes ☐No
3. Will there be slurries from mortar mixing, coring, or concrete saw cutting?
Reference Table 1 Items D and F
☐Yes ☐No
4. Will there be solid wastes from concrete demolition and removal, wall
construction, or form work?
Reference Table 1 Items D and F
☐Yes ☐No
5. Will there be stockpiling (soil, compost, asphalt, concrete, solid waste) for over
24 hours?
Reference Table 1 Items D and F
☐Yes ☐No
6. Will there be dewatering operations?
Reference Table 1 Items C and D
☐Yes ☐No
7. Will there be temporary on-site storage of construction materials, including
mortar mix, raw landscaping and soil stabilization materials, treated lumber,
rebar, and plated metal fencing materials?
Reference Table 1 Items E and F
☐Yes ☐No
8. Will trash or solid waste product be generated from this project?
Reference Table 1 Item F
☐Yes ☐No
9. Will construction equipment be stored on site (e.g.: fuels, oils, trucks, etc.?)
Reference Table 1 Item F
☐Yes ☐No
10. Will Portable Sanitary Services (“Porta-potty”) be used on the site?
Reference Table 1 Item F
☐Yes ☐No
1 Minimum required BMPs are those necessary to comply with the City of Temecula Erosion and Sediment
Control Ordinance (Chapter 18.18 et seq.) and the City of Temecula Engineering and Construction Manual
(Chapter 18).
Template Date: October 31
st, 2018 Preparation Date:___________
8 WQMP
Table 1. Construction Stormwater BMP Checklist
Minimum Required
Best Management Practices
(BMPs)
CALTRANS
SW
Handbook2
Detail
BMP
Selected
Reference sheet No.’s where each
selected BMP is shown on the
plans.
If no BMP is selected, an
explanation must be provided.
A. Select Erosion Control Method for Disturbed Slopes (choose at least one for the appropriate
season)
Vegetation Stabilization
Planting3 (Summer)
SS-2, SS-4 ☐
Hydraulic Stabilization
Hydroseeding2 (Summer)
SS-4 ☐
Bonded Fiber Matrix or
Stabilized Fiber Matrix
4 (Winter)
SS-3 ☐
Physical Stabilization
Erosion Control Blanket
3
(Winter)
SS-7 ☐
B. Select erosion control method for disturbed flat areas (slope < 5%) (choose at least one)
Will use erosion control
measures from Item A on flat
areas also
SS-3, 4, 7 ☐
Sediment Desilting Basin (must
treat all site runoff )
SC-2 ☐
Mulch, straw, wood chips, soil
application
SS-6, SS-8 ☐
Table 1. Construction Stormwater BMP Checklist (continued)
Minimum Required
Best Management Practices
(BMPs)
CALTRANS
SW Handbook
Detail
BMP
Selected
Reference sheet No.’s where each
selected BMP is shown on the
plans.
If no BMP is selected, an
explanation must be provided.
C. If runoff or dewatering operation is concentrated, velocity must be controlled using an energy
dissipater
Energy Dissipater Outlet
Protection5
SS-10 ☐
D. Select sediment control method for all disturbed areas (choose at least one)
Silt Fence SC-1 ☐
Fiber Rolls (Straw Wattles)SC-5 ☐
Gravel & Sand Bags SC-6 & 8 ☐
5 Regional Standard Drawing D-40 – Rip Rap Energy Dissipater is also acceptable for velocity reduction.
4 All slopes over three feet must have established vegetative cover prior to final permit approval.
3 If Vegetation Stabilization (Planting or Hydroseeding) is proposed for erosion control it may be installed between
May 1st and August 15th. Slope irrigation is in place and needs to be operable for slopes >3 feet. Vegetation
must be watered and established prior to October 1st. The owner must implement a contingency physical BMP
by August 15th if vegetation establishment does not occur by that date. If landscaping is proposed, erosion
control measures must also be used while landscaping is being established. Established vegetation must have
a subsurface mat of intertwined mature roots with a uniform vegetative coverage of 70 percent of the natural
vegetative coverage or more on all disturbed areas.
2 State of California Department of Transportation (Caltrans). 2003. Storm Water Quality Handbooks, Construction
Site Best Management Practices (BMPs) Manual. March. Available online at:
http://www.dot.ca.gov/hq/construc/stormwater/manuals.htm.
Preparation Date: ___________Template Date: October 31
st, 2018
WQMP 9
Dewatering Filtration NS-2 ☐
Storm Drain Inlet Protection SC-10 ☐
Engineered Desilting Basin
(sized for 10-year flow)
SC-2 ☐
E. Select method for preventing offsite tracking of sediment (choose at least one)
Stabilized Construction
Entrance
TC-1 ☐
Construction Road Stabilization TC-2 ☐
Entrance/Exit Tire Wash TC-3 ☐
Entrance/Exit Inspection &
Cleaning Facility
TC-1 ☐
Street Sweeping and
Vacuuming
SC-7 ☐
F. Select the general site management BMPs
F.1 Materials Management
Material Delivery & Storage WM-1 ☐
Spill Prevention and Control WM-4 ☐
F.2 Waste Management
6
Waste Management
Concrete Waste Management
WM-8 ☐
Solid Waste Management WM-5 ☐
Sanitary Waste Management WM-9 ☐
Hazardous Waste Management WM-6 ☐
Note: The Construction General Permit (Order No. 2009-0009-DWQ) also requires all projects
not subject to the BMP Design Manual to comply with runoff reduction requirements through
the implementation of post-construction BMPs as described in Section XIII of the order.
6 Not all projects will have every waste identified. The applicant is responsible for identifying wastes that will be
onsite and applying the appropriate BMP. For example, if concrete will be used, BMP WM-8 must be selected.
Template Date: October 31
st, 2018 Preparation Date:___________
10 WQMP
Step 4: Project type determination (Standard or Priority
Development Project)
Is the project part of another Priority Development Project (PDP)?☐Yes ☐No
If so, Standard and PDP requirements apply. Go to Step 4.1 and select “PDP”
The project is (select one):☐New Development ☐Redevelopment7
The total proposed newly created or replaced impervious area is:_______________ft2
The total existing (pre-project) impervious area is:_______________ft2
The total area disturbed by the project is:_______________ft2
If the total area disturbed by the project is 1 acre (43,560 sq. ft.) or more OR the project is part of a larger
common plan of development disturbing 1 acre or more, a Waste Discharger Identification (WDID) number
must be obtained from the State Water Resources Control Board.
WDID:_______________
Is the project in any of the following categories, (a) through (f)?
8
Yes
☐
No
☐
(a)New development projects that create 10,000 square feet or more of impervious
surfaces 9(collectively over the entire project site). This includes commercial, industrial,
residential, mixed-use, and public development projects on public or private land.
Yes
☐
No
☐
(b)Redevelopment projects that create and/or replace 5,000 square feet or more of
impervious surface (collectively over the entire project site on an existing site of 10,000
square feet or more of impervious surfaces). This includes commercial, industrial,
residential, mixed-use, and public development projects on public or private land.
Yes
☐
No
☐
(c)New and redevelopment projects that create and/or replace 5,000 square feet or more
of impervious surface (collectively over the entire project site), and support one or more
of the following uses:
(i) Restaurants. This category is defined as a facility that sells prepared foods and
drinks for consumption, including stationary lunch counters and refreshment
stands selling prepared foods and drinks for immediate consumption (Standard
Industrial Classification (SIC) code 5812).
(ii) Hillside development projects. This category includes development on any
natural slope that is twenty-five percent or greater.
(iii) Parking lots. This category is defined as a land area or facility for the temporary
parking or storage of motor vehicles used personally, for business, or for
commerce.
(iv) Streets, roads, highways, freeways, and driveways. This category is defined as
any paved impervious surface used for the transportation of automobiles,
trucks, motorcycles, and other vehicles.
9
8 Applicants should note that any development project that will create and/or replace 10,000 square feet or more
of impervious surface (collectively over the entire project site) is considered a new development.
7 Redevelopment is defined as:The creation and/or replacement of impervious surface on an already developed
site. Examples include the expansion of a building footprint, road widening, the addition to or replacement of a
structure, and creation or addition of impervious surfaces. Replacement of impervious surfaces includes any
activity that is not part of a routine maintenance activity where impervious material(s) are removed, exposing
underlying soil during construction. Redevelopment does not include routine maintenance activities, such as
trenching and resurfacing associated with utility work; pavement grinding; resurfacing existing roadways; new
sidewalks construction; pedestrian ramps; or bike lanes on existing roads; and routine replacement of damaged
pavement, such as pothole repair.
Preparation Date: ___________Template Date: October 31
st, 2018
340
WQMP 11
Project type determination (continued)
Yes
☐
No
☐
(d)New or redevelopment projects that create and/or replace 2,500 square feet or more of
impervious surface (collectively over the entire project site), and discharging directly to
an Environmentally Sensitive Area (ESA). “Discharging directly to” includes flow that is
conveyed overland a distance of 200 feet or less from the project to the ESA, or
conveyed in a pipe or open channel any distance as an isolated flow from the project to
the ESA (i.e. not commingled with flows from adjacent lands).
Note: ESAs are areas that include but are not limited to all Clean Water Act Section
303(d) impaired water bodies; areas designated as Areas of Special Biological
Significance by the State Water Board and San Diego Water Board; State Water
Quality Protected Areas; water bodies designated with the RARE beneficial use by
the State Water Board and San Diego Water Board; and any other equivalent
environmentally sensitive areas which have been identified by the Copermittees.
See BMP Design Manual Chapter 1.4.2 for additional guidance.
Yes
☐
No
☐
(e)New development projects, or redevelopment projects that create and/or replace 5,000
square feet or more of impervious surface, that support one or more of the following
uses:
(i) Automotive repair shops. This category is defined as a facility that is categorized
in any one of the following SIC codes: 5013, 5014, 5541, 7532-7534, or
7536-7539.
(ii) Retail gasoline outlets (RGOs). This category includes RGOs that meet the
following criteria: (a) 5,000 square feet or more or (b) a projected Average Daily
Traffic (ADT) of 100 or more vehicles per day.
Yes
☐
No
☐
(f)New or redevelopment projects that result in the disturbance of one or more acres of
land and are expected to generate pollutants post construction.
Note: See BMP Design Manual Chapter 1.4.2 for additional guidance.
Does the project meet the definition of one or more of the Priority Development Project categories (a)
through (f) listed above?
☐No – the project is not a Priority Development Project (Standard Project).
☐Yes – the project is a Priority Development Project (PDP).
Further guidance may be found in Chapter 1 and Table 1-2 of the BMP Design Manual.
The following is for redevelopment PDPs only:
The area of existing (pre-project) impervious area at the project site is:_______________ft2 (A)
The total proposed newly created or replaced impervious area is _______________ft2 (B)
Percent impervious surface created or replaced (B/A)*100:_______________%
The percent impervious surface created or replaced is (select one based on the above calculation):
☐less than or equal to fifty percent (50%) –only newly created or replaced impervious areas are
considered a PDP and subject to stormwater requirements
OR
☐greater than fifty percent (50%) –the entire project site is considered a PDP and subject to
stormwater requirements
Template Date: October 31
st, 2018 Preparation Date:___________
12 WQMP
Step 4.1: Water Quality Management Plan requirements
Step Answer Progression
Is the project a Standard Project,
Priority Development Project (PDP), or
exception to PDP definitions?
To answer this item, complete Step 4
Project Type Determination Checklist,
and see PDP exemption information
below.
For further guidance, see Chapter 1.4
of the BMP Design Manual in its
entirety.
☐Standard
Project
Standard Project requirements apply,STOP,
you have satisfied stormwater
requirements.
☐PDP Standard and PDP requirements apply.
Complete Exhibit A “PDP
Requirements.”
http://temeculaca.gov/wqmpa2
☐PDP
Exemption
Go to Step 4.2 below.
Step 4.2: Exemption to PDP definitions
Is the project exempt from PDP definitions based on either of the
following:
☐Projects that are only new or retrofit paved sidewalks, bicycle
lanes, or trails that meet the following criteria:
(i) Designed and constructed to direct stormwater runoff to
adjacent vegetated areas, or other non-erodible
permeable areas; OR
(ii) Designed and constructed to be hydraulically
disconnected from paved streets or roads [i.e., runoff
from the new improvement does not drain directly onto
paved streets or roads]; OR
(iii) Designed and constructed with permeable pavements or
surfaces in accordance with City of Temecula Guidance
on Green Infrastructure;
If so:
Standard Project
requirements apply, AND
any additional
requirements specific to
the type of project. City
concurrence with the
exemption is required.
Provide discussion and list
any additional
requirements below in this
form.
STOP, you have
satisfied stormwater
requirements.
☐Projects that are only retrofitting or redeveloping existing paved
alleys, streets or roads that are designed and constructed in
accordance with the City of Temecula Guidance on Green
Infrastructure.
Complete Exhibit A
“PDP Requirements.”
Select Green Streets
Exemptions where
applicable.
Preparation Date: ___________Template Date: October 31
st, 2018
WQMP 13
Discussion /justification,and additional requirements for exceptions to PDP definitions,if applicable:
Template Date:October 31st,2018 Preparation Date:___________
MAIN
RESIDENCE
SUN ROOM
TO BE REMOVED
DRIVEWAY
(E) LANDSCAPE
SIDEWALK SIDEWALK
(E) LANDSCAPE
(E)
2
%
S
L
O
P
E
(E)
2
%
S
L
O
P
E
(E)
2
%
S
L
O
P
E
(E
)
2
%
S
L
O
P
E
(
E
)
2
%
S
L
O
P
E
(
E
)
2
%
S
L
O
P
E
(
E
)
2
%
S
L
O
P
E
(
E
)
2
%
S
L
O
P
E
(E
)
2
%
S
L
O
P
E
(E)6' CHAINLINK FENCE
(
E
)
6
'
W
O
O
D
F
E
N
C
E
(E
)
6
'
W
O
O
D
F
E
N
C
E
(E)
100AMP SUB-PANEL
(E)
GAS METER
(E) WATER
METER
27
'
-
9
"
26'-3"
A1.0
PROJECT INFO
&
SITE PLAN
NO. REVISION
DATE
SCALE
DRAWN BY
JOB NO 01-23
CARLOS PEREZ-RAMIREZ - DESIGNER
RESTRICTIVE NOTICE:
ALL DESIGN, IDEAS, DETAILS, PLANS AND
SPECIFICATIONS INDICATED BY THE DRAWINGS ARE
THE EXCLUSIVE PROPERTY OF FS DESIGN GROUP, THE
PLANS WERE CREATED AND DEVELOPED FOR USE ON
AND IN CONJUNCTION WITH THE SPECIFIC PROJECT
DESCRIBED HEREIN. NOT PART THEREOF SHALL BE
REPRODUCED, COPIED, ADAPTED, MODIFIED OR
DISTRIBUTE TO OTHERS WITHOUT PRIOR WRITTEN
AND SPECIFIC CONSENT OF FS DESIGN GROUP
CPR
1/8" = 1'-0"
C: 626.780.0228
E: CPRSTUDIOOO@GMAIL.COM
CPR
STUDIO
CARLOS PEREZ-RAMIREZ
SITE PREPARATION
INTERIOR
BATH
1. THE METHOD OF CLEARING AND STRIPPING SHOULD BE VERIFY BY THE CONTRACTOR.
2. ALL SURFACE VEGETATION, DEBRIS AND STRUCTURES TO BE DEMOLISHED SHALL BE REMOVED FROM THE SITE PRIOR TO COMMENCING SITE
PREPARATION, EXCAVATION OR PLACEMENT FILL.
3. FILL FOR FLOOR SLABS AND FOUNDATION TRENCHES SHALL CONSIST OF NATIVE SOIL.
4. NATIVE SOIL PLACED FOR SLAB SUPPORT SHALL BE PLACED IN LAYERS NOT EXCEEDING 4" WHEN COMPACTED.
5. IMPORT FOR SLAB SUPPORT SHALL CONSIST OF SAND, GRAVELY SAND OR SILTY SAND AND SHALL HAVE A EXPANSION INDEX OF LESS THAN 30.
1. ALL WORK SHALL COMPLY WITH THE 2019 CALIFORNIA BUILDING CODE, TITLE 24 AND ALL APPLICABLE CODES, REGULATIONS OR
REQUIREMENTS OF THE CITY OR COUNTY HAVING JURISDICTION FOR THE PLACE OF THE BUILDING.
2. PERMITS SHALL BE OBTAINED FOR FENCES, POOLS, SPA OR RETAINING WALLS.
3. FINAL GRADING WORK SHALL COMPLY WITH 2019 CBC AND SHALL PROVIDE POSITIVE DRAINAGE FROM ALL PARTS OF THE BUILDING AND
SHALL NOT DRAIN ONTO ADJACENT PROPERTIES.
4. ALL SURFACES SHALL BE SLOPED TO DRAIN WATER AWAY FROM THE BUILDING.
5. AT TIME OF PERMIT ISSUANCE, THE CONTRACTOR SHALL SHOW THEIR VALID "WORKERS COMPENSATION" INSURANCE CERTIFICATE.
6. ALL WORK SHALL CONFORM TO ALL REQUIREMENTS OF THE INFORMATION INDICATED ON THESE PLANS.
7. BUILDING ADDRESS NUMBERS SHALL BE PROVIDED ON THE FRONT OF ALL BUILDINGS AND SHALL BE VISIBLE AND LEGIBLE FROM THE
STREET FRONTING THE PROPERTY, SAID NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND.
1. PROVIDE 72 INCH HIGH NONABSORBENT WALL ADJACENT TO SHOWER, AND APPROVED SHATTER RESISTANT MATERIALS FOR SHOWER.
2. ONLY LOW CONSUMPTION WATER CLOSETS SHALL BE PROVIDED. "PROVIDE ULTRA FLUSH WATER CLOSETS FOR ALL NEW
CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION."
3. ENCLOSED USABLE SPACE UNDER INTERIOR STAIRWAYS REQUIRES 1-HOUR FIRE RESISTIVE CONSTRUCTION ON ENCLOSED SIDE.
4. EXIT DOORWAYS SHALL BE NOT LESS THAN 36" X 6'-8" (WIDTH AND HEIGHT). PROJECTIONS INCLUDING PANIC HARDWARE, SHALL NOT
REDUCE THE OPENING TO LESS THAN 32" CLEAR WIDTH.
5. PROVIDE 32" WIDE DOORS TO ALL ACCESSIBLE ROOMS WITHIN A DWELLING UNIT.
6. GLASS SKYLIGHTS SHALL COMPLY WITH 91.2409. PLASTIC SKYLIGHTS WITH 91.1006.12
7. PROVIDE WINDOW WELLS (WITH FIXED LADDER) FOR EGRESS WINDOWS BELOW GRADE.
8. WATER HEATER IS REQUIRED TO BE ANCHORED. "WATER HEATER MUST BE STRAPPED TO WALL."
9. PROVIDE ACCESS TO THE BOTTOM OF COURT FOR CLEANING PURPOSES.
10. COURT MORE THAN TWO STORIES IN HEIGHT SHALL BE PROVIDED WITH A HORIZONTAL AIR INTAKE WITH A MINIMUM AREA OF 10 SQ.FT.
1. WALL COVERING SHALL BE CEMENT PLASTER, TILE OR APPROVED EQ. WITHIN 72" ABOVE DRAIN.
2. MATERIALS OTHER THAN STRUCTURAL ELEMENTS TO BE MOISTURE RESISTANT MATERIALS:
3. GLASS ENCLOSURE DOORS MUST BE LABELED CATEGORY II SWING DOOR OUTWARD.
4. NET AREA OF SHOWER RECEPTOR NOT LESS THAN 1024 " OR 30" DIA CIR 510, 511, 5406, 5407, UBC STD. T-54 & D.C. 909.
5. BATHS WITHOUT OPENABLE WINDOWS SHALL BE PROVIDED WITH VENT FAN CAPABLE OF MINIMUM 5 AIR CHANGES PER HR.
6. TOILET COMPARTMENT MINIMUM 30" WIDE WITH 24" CIR. IN FRONT OF TOILET.
7. PROVIDE MINIMUM 12" X 12" ACCESS AT TUB TRAP EXCEPT WHERE CONCERNED FIXED CONNECTIONS ARE OF BRASS & WITHOUT SLIP JOINTS.
8. PROVIDE MECHANICAL VENTILATION CONNECTED DIRECTLY TO THE OUTSIDE CAPABLE OF PROVIDING FIVE A/P CHANGES PER HOUR IN
BATHROOMS, WATER CLOSET COMPARTMENTS, LAUNDRY ROOMS, AND SIMILAR ROOMS.
SITE NOTES
DOOR MARKER
A WINDOW MARKER
28
A5.7
28
A5.7
28
A5.7
28
A5.7 SECTION MARKER
ELEVATION MARKER
DETAIL MARKER
28
4.12.5 KEY NOTE
28 CORRECTION #
A. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION
FACILITIES (POWER POLES, PULL BOXES, TRANSFORMERS, VAULTS, PUMPS, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION
OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES - WHETHER OR NOT THE LINES ARE
LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES.
B. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY
METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. (PER
ORDINANCE 170, 158) (INCLUDES COMMERCIAL ADDITIONS AND TI WORK OVER $10,000) SEPARATE PLUMBING PERMIT IS REQUIRED.
C. PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A SANITARY SEWER OR TO AN APPROVED SEWAGE DISPOSAL SYSTEM
(R306.3)
D. KITCHEN SINKS, LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY TUBS AND WASHING MACHINE OUTLES SHALL BE PROVIDED WITH
HOT AND COLD WATER AND CONNECTED TO AN APPROVED WATER SUPPLY (R306.4)
E. BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH A SHOWER HEAD, AND SHOWER COMPARTMENTS SHALL BE FINISHED
WITH A NON-ABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET AOBVE THE
FLOOR (R307.2)
F. PROVIDE ULTRA LOW FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED
FOR LOW WATER CONSUMPTION.
G. PROVIDE 72 INCH HIGH NON-ABSORBANT WALL ADJACENT TO SHOWER AND APPROVED SHATTER-RESISTANT MATERIALS FOR SHOWER
ENCLOSURE. (1115B.2 AND 2406.3(5)
H. UNIT SKYLIGHTS SHALL BE LABELED BY AN LA CITY APPROVED LABELING AGENCY. SUCH LABEL SHALL STATE THE APPROVED LABELING
AGENCY NAME, PRODUCT DESIGNATION AND PERFORMANCE GRADE RATING (RESEARCH REPORT NOT REQUIRED). (R308.6.9)
I. WATER HEATER MUST BE STRAPPED TO WALL (SEC. 507.3, UPC)
M. SMOKE DETECTORS SHALL BE PROVIDED FOR ALL DWELLING UNITS INTENDED FOR HUMAN OCCUPANCY, UPON THE OWNER'S
APPLICATION FOR A PERMIT FOR ALTERATIONS, REPAIRS, OR ADDITIONS, EXCEEDING ONE THOUSAND DOLLARS ($1,000). (R314.6.2)
N.A. WHERE A PERMIT IS REQUIRED FOR ALTERATIONS, REPAIRS OR ADDITIONS EXCEEDING ONE THOUSAND DOLLARS ($1,000), EXISTING
DWELLINGS OR SLEEPING UNITS THAT HAVE ATTACHED GARAGES OR FUEL BURNING APPLIANCES SHALL BE PROVIDED WITH A
CARBON MONOXIDE ALARM IN ACCORDANCE WITH SECTIONS R315.1. CARBON MONOXIDE ALARMS SHALL ONLY BE REQUIRED IN THE
SPECIFIC DWELLING UNIT OR SLEEPING UNIT FOR WHICH THE PERMIT WAS OBTAINED. (R315.2)
N.B. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL LIGHT BY MEANS OF EXTERIOR GLAZED
OPENINGS IN ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE
AN AVERAGE ILLUMINATION OF 6 FOOT-CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30 INCHES ABOVE THE FLOOR
LEVEL. (R303.1)
O. A COPY OF THE EVALUATION REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE
SPECIAL HAZARDS
1. ROOF OBSTRUCTIONS SUCH AS TELEVISION ANTENNA, GUY WIRES, SOLAR PANELS, RAZOR RIBBON FENCE, CABLE OR OTHER
OBSTRUCTIONS SHALL NOT PREVENT FIRE DEPARTMENT ACCESS OR EGRESS IN THE EVENT OF FIRE.
2. PROVIDE COLLISION BARRIERS ADEQUATE TO PROTECT CONTROL METERS, REGULATORS AND PIPING FOR HAZARDOUS MATERIALS
THAT ARE EXPOSED TO VEHICULAR DAMAGE LAMC 57.12.02.
3. THE INDOOR STORAGE OF COMBUSTIBLE MATERIALS SHALL BE REGULATED IN RELATION TO ARRANGEMENT, LOCATION, SIZE OF
AREAS, HEIGHT SEPARATIONS AND HOUSEKEEPING.
MISCELLANEOUS
1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS OF THE JOB SITE BEFORE STARTING ANY WORK AND BE
RESPONSIBLE FOR THE SAME, THE ARCHITECT SHALL BE NOTIFY OF ANY DISCREPANCIES WHICH MAY EXIST. CONTRACTOR SHALL
NOT SCALE ANY DRAWINGS.
2. THE SPECIFICATIONS ARE OF A GENERAL NATURE AND MAY REFER TO WORK WHICH IS NOT REQUIRED. THEY ARE NOT INTENDED TO
SUPERSEDE ANY CONTRACTUAL AGREEMENT BETWEEN THE OWNER AND THE CONTRACTOR.
3. THE CONTRACTOR SHALL PROVIDE SUPERVISION TO PROPERLY EXECUTE THE PROJECT AND TO PROVIDE ASSURANCE THE WORK IS IN
ACCORDANCE WITH THE PLANS AND SPECIFICATIONS.
4. ALL NECESSARY PERMITS SHALL BE SECURED BY THE CONTRACTOR PRIOR TO START ANY CONSTRUCTION.
BUILDING CODE NOTES:
VICINITY MAP
NORTH ARROW
OWNER
ADOLFO GARCIA
DESIGNER
CARLOS PEREZ-RAMIREZ
CPR- STUDIO
11220 GARVEY AVE,
EL MONTE, CA 91733
P: 626-780-0228
E: CPRSTUDIOOO@GMAIL.COM
ALL WORK SHALL COMPLY WITH THE FOLLOWING
CODES INCLUDING AMENDMENTS:
* 2022 CALIFORNIA RESIDENTIAL CODE
* 2022 CALIFORNIA BUILDING CODE
* 2022 CALIFORNIA PLUMBING CODE
* 2022 CALIFORNIA MECHANICAL CODE
* 2022 CALIFORNIA ELECTRICAL CODE
* 2022 CALIFORNIA ENERGY CODE. (TITLE 24)
* 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE
* 2022 CITY OF WHITTIER MUNICIPAL CODE
* 2022 LA COUNTY FIRE CODE
MATERIAL CONSERVATION & RESOURCE EFFICIENCY
ANNUAL SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS OR OTHER OPENINGS IN SOLE/BOTTOM PLATES AT EXTERIOR WALLS SHALL
BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY OR
SIMILAR METHODS.
ENVIRONMENTAL QUALITY
A. AT THE TIME OF ROUGH INSTALLATION, OR DURING STORAGE ON THE CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING,
COOLING, AND VENTILATING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED
WITH TAPE, PLASTIC, SHEET METAL, OR OTHER ACCEPTABLE METHODS TO REDUCE THE AMOUNT OF WATER, DUST, AND DEBRIS WHICH MAY
ENTER THE SYSTEM.
B. BUILDING MATERIALS WITH VISIBLE SIGNS OF WATER DAMAGE SHALL NOT BE INSTALLED. WALL AND FLOOR FRAMING SHALL NOT BE
ENCLOSED WHEN THE FRAMING MEMBERS EXCEED 19% MOISTURE CONTENT. INSULATION PRODUCTS WHICH ARE VISIBLE WET OR HAVE
HIGH MOISTURE CONTENT SHALL BE REPLACED OR ALLOWED TO DRY PRIOR TO ENCLOSURE IN WALL OR FLOOR CAVITIES.
C. ALL MECHANICAL EXHAUST FANS IN ROOMS WITH A BATHTUB OR SHOWER SHALL COMPLY WITH THE FOLLOWING:
- FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMITE OUTSIDE THE BUILDING.
- FANS MUST BE CONTROLLED BY A HUMIDITY CONTROL CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF
< 50% TO A MAXIMUM OF 80% UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM.
FINISH MATERIAL POLLUTANT CONTROL
A. ADHESIVE, SEALANTS AND CAULKS SHALL MEET OR EXCEED THE STANDARDS OUTLINED IN SECTION 4.504.2.1 AND COMPLY WITH THE VOC
LIMITS IN TABLES 4.504.1 AND 4.504.2 AS APPLICABLE.
B. PAINTS AND COATINGS SHALL MEET OR EXCEED THE STANDARDS OUTLINED IN SECTION 4.504.2.2. AND COMPLY WITH THE VOC LIMITS IN
TABLE 4.504.3.
C. AEROSOL PAINTS AND COATINGS SHALL MEET OR EXCEED THE STANDARDS OUTLINED IN SECTION 4.504.2.3
D. ALL CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE TESTING AND PRODUCT REQUIREMENTS OF ONE OF HE FOLLOWING:
I. CARPET AND RUG INSTITUTE'S GREEN LABEL PLUS PROGRAM OR
II. CALIFORNIA DEPARTMENT OF PUBLIC HEALTH STANDARD METHODS FOR THE TESTING OF VOC EMISSIONS (SPEC 01350)
OR
III. NSF/ANSI 140 AT THE GOLD LEVEL OR
IV. SCIENTIFIC CERTIFICATIONS SYSTEMS INDOOR ADVANTAGE GOLD
E. ALL CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE REQUIREMENTS OF THE CARPET AND RUG INSTITUTE GREEN
LABEL PROGRAM. CARPET ADHESIVES SHALL NOT EXCEED A VOC LIMIT OF 50 G/L.(4.504.3.1, 4.504.3.2)
F. A MINIMUM OF 80% OF FLOOR AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH ONE OR MORE OF THE FOLLOWING:
I. PRODUCTS CERTIFIED AS A LOW-EMITTING MATERIAL IN THE CHPS HIGH PERFORMANCE PRODUCTS DATABASE OR
II. PRODUCTS CERTIFIED UNDER UL GREEN GUARD GOLD (FORMERLY THE GREEN GUARD CHILDREN & SCHOOLS
PROGRAM), OR
III. CERTIFICATION UNDER THE RFCI FLOORSCORE PROGRAM OR
IV. MEET THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH STANDARD METHOD FOR THE TESTING OF VOC EMISSIONS (SPEC
01350)
G. COMPOSITE WOOD PRODUCTS (HARDWOOD PLYWOOD, PARTICLE BOARD, AND MDF) INSTALLED ON THE INTERIOR OR EXTERIOR OF HE
BUILDING SHALL MEET OR EXCEED THE STANDARDS OUTLINED IN TABLE 4.504.5. VERIFICATION OF COMPLIANCE WITH THESE SECTIONS
MUST BE PROVIDED AT HE TIME OF INSPECTION.
SHEET INDEX
A1.0 PROJECT INFO
NORTH
SCOPE OF WORK:
PROJECT DESCRIPTION:
SCOPE OF WORK: ADDITION TO KITCHEN AREA (340 SQ.FT)
BUILDING INFORMATION:
LEGAL DESCRIPTION:
SITE ADDRESS:
ZIP CODE:
LOT/PARCEL AREA (CALCULATED):
ASSESSOR PARCEL NO. (APN):
30377 CUPENO LN. TEMECULA, CA,
92592
6,534 SQ. FT.
922-343-010
PERMIT NOTES
1. APPLICATIONS FOR WHICH NO PERMIT IS ISSUED WITHIN 180 DAYS FOLLOWING THE DATE OF APPLICAITON SHALL AUTOMATICALLY
EXPIRE. (R105.3.2) CRC
2. EVERY PERMIT ISSUED SHALL BECOME INVALID UNLESS WORK AUTHORIZED IS COMMENCED WITHIN 180 DAYS AFTER ITS ISSUANCE OR
IF THE WORK AUTHORIZED IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS. A SUCCESSFUL INSPECTION MUST BE OBTAINED
WITHIN 180 DAYS. NOTE ON PLANS. (R105.5 CRC)
3. ALL HERS REQUIRED INSPECTIONS SHALL BE DONE
4. FIRE DEPARTMENT WILL REQUIRE CLEARANCE AND APPROVAL. SEPARATE PERMIT FOR FIRE DEPARTMENT REQUIRED.
CONSTRUCTION TYPE:TYPE VB - NON-SPRINKLERS
OCCUPANCY:SINGLE FAMILY RESIDENCY
STORIES:1
OVERALL HEIGHT:17'-4"
ZONE:R-3
EXISTING
30377 CUPENO LN SINGLE FAMILY RESIDENCE 1083 sq.ft
FRACTIONAL AREA 52 sq.ft
ATTACHED GARAGE 430 sq.ft
PROPOSED
PROPOSED KITCHEN ADDITION
340 SQ.FT
TOTAL LIVING AREA: 1,905 SQ. FT.
TOTAL= 1,905 SQ. FT. / 7840 SQ. FT. = 24.2%
FIRE COMMENTS (CONT.)
E. APPROVED BUILDING ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION SHALL BE PROVIDED AND
MAINTAINED SO AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET FRONTING OF THE PROPERTY. THE NUMBERS SHALL
CONTRAST WITH THEIR BACKGROUND, BE ARABIC NUMERALS OR ALPHABET LETTERS, AND BE A MIM=NIMUM OF 4 INCHES HIGH
WITH A MINIMUM STROKE WIDTH OF 0.5 INCHES. FIRE CODE 505.1
A1.1 EXISTING SITE PLAN & PROPOSED SITE PLAN
A2.0 EXISTING MAIN DWELLING FLOOR PLAN/PROPOSED PLAN
A3.1 PROPOSED ELEVATIONS
T-1 TITLE 24
S-2 FOUNDATION PLAN
S-3 ROOF FRAMING PLAN
SD-1 DETAILS
EV CHARGERS INSTALLATION
1. TO FACILITATE INSTALLATION AND USE OF EVE CHARGERS. ELECTRIC VEHICLE SUPPLY EQUIPMENT (EVSE) SHALL BE INSTALLED IN
IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL CODE, ARTICLE 625. INSTALL A LISTED RACEWAY TO ACCOMMODATE A
DEDICATED 208/240-VOLT BRANCH CIRCUIT. THE RACEWAY SHALL NOT BE LESS THAN TRADE SIZE 1 (NOMINAL 1- INCH INSIDE
DIAMETER). THE RACEWAY SHALL ORIGINATE AT THE MAIN SERVICE OR SUBPANEL AND SHALL TERMINATE INTO A LISTED CABINET,
BOR OR OTHER ENCLOSURE IN CLOSE PROXIMITY TO THE PROPOSED LOCATION OF AN EV CHARGER. RACEWAYS ARE REQUIRED
TO BE CONTINOUS AT ENCLOSED, INACCESSIBLE OR CONCEALED AREAS AND SPACES. THE SERVICE PANEL AND/OR SUBPANEL
SHALL PROVIDE CAPACITY TO INSTALL A 40-AMPERE MINIMUM DEDICATED BRANCH CIRCUIT AND SPACE(S) RESERVED TO PERMIT
INSTALLATION OF A BRANCH CIRCUIT OVERCURRENT PROTECTIVE DEVICE. 4.106.4.1.1 IDENTIFICATION. THE SERVICE PANEL OR
SUB-PANEL CIRCUIT DIRECTORY SHALL IDENTIFY THE OVERCURRENT PROTECTIVE DEVICE SPACE(S) RESERVED FOR FUTURE EV
CHARGING AS "EV CAPABLE". THE RACEWAY TERMINATION LOCATION SHALL BE PERMANENTLY AND VISIBLY MARKED AS "EV
CAPABLE".
CG1.1
NON-COMPLIANT PLUMBING FIXTURES
1. ALL NON-COMPLIANT PLUBMING FIXTURES SHALL BE REPLACED WITH WATER CONSERVING PLUMBING FIXTURES (CIVIL CODE SECTION
1101.4(b)) NON-COMPLIANT PLUMBING FIXTURES MEANS ANY OF THE FOLLOWING:
a. ANY TOILET MANUFACTURED TO USE MORE THAN 1.6 GALLONS OF WATER PER FLUSH.
b. ANY URINAL MANUFACTURED TO USE MORE THAN 1 GALLON OF WATER PER FLUSH.
c. ANY SHOWERHEAD MANUFATURED TO HAVE A FLOW CAPACITY OF MORE THAN 2.5 GALLONS OF WATER PER MINUTE.
d. ANY INTERIOR FAUCET THAT EMITS MORE THAN 2.2 GALLONS OF WATER PER MINUTE.
S-1.2 SPECIFICATIONS
S-1.1 SPECIFICATIONS
SCALE: 1/8" = 1'-0"
SITE PLAN
NORTH
A2.1 PROPOSED FLOOR PLAN
CONTRACTOR NEEDS TO INSPECT ALL UNDERGROUND UTILITIES
BEFORE COMMENCING WORK.
NOTE:
DIG ALERT IS TO BE CONTACTED BEFORE COMMENCING WORK,
COMPLIANCE WITH EXCAVATION SAFETY MUST BE IN ACCORDANCE WITH
GOVERNMENT CODE 4216 WILL BE FOLLOWED PRIOR TO ANY
EXCAVATION TAKING PLACE.
A4.0 ELECTRICAL PLAN
GA
R
C
I
A
R
E
S
I
D
E
N
C
E
30
3
7
7
C
U
P
E
N
O
L
N
,
T
E
M
E
C
U
L
A
,
C
A
.
9
2
5
9
2
12/03/2024
T-2 TITLE 24
SD-2 DETAILS
SD-3 DETAILS
SD-4 DETAILS
SD-5 DETAILS
CLEARED BY
CITY OF TEMECULA
PUBLIC WORKS
SUBJECT TO BUILDING DEPARTMENT
APPROVAL
PERMITS ARE REQUIRED
Chris.White 01/13/2025
01/13/2025 01/13/2025
01/13/20
MAIN
RESIDENCE
SUN ROOM
TO BE REMOVED
DRIVEWAY
(E) LANDSCAPE
SIDEWALK SIDEWALK
(E) LANDSCAPE
(E)
2
%
S
L
O
P
E
(E)
2
%
S
L
O
P
E
(E)
2
%
S
L
O
P
E
(E)
2
%
S
L
O
P
E
(
E
)
2
%
S
L
O
P
E
(
E
)
2
%
S
L
O
P
E
(
E
)
2
%
S
L
O
P
E
(
E
)
2
%
S
L
O
P
E
(E
)
2
%
S
L
O
P
E
(E)6' CHAINLINK FENCE
(
E
)
6
'
W
O
O
D
F
E
N
C
E
(E
)
6
'
W
O
O
D
F
E
N
C
E
(E)
100AMP SUB-PANEL
(E)
GAS METER
(E)WATER
METER
27
'
-
9
"
26'-3"
MAIN
RESIDENCE
KITCHEN
ADDITION
DRIVEWAY
(E) LANDSCAPE
SIDEWALK SIDEWALK
(E) LANDSCAPE
(E)
2
%
S
L
O
P
E
(E)
2
%
S
L
O
P
E
(E)
2
%
S
L
O
P
E
(E)
2
%
S
L
O
P
E
(
E
)
2
%
S
L
O
P
E
(
E
)
2
%
S
L
O
P
E
(
E
)
2
%
S
L
O
P
E
(
E
)
2
%
S
L
O
P
E
(E
)
2
%
S
L
O
P
E
(E)6' CHAINLINK FENCE
(
E
)
6
'
W
O
O
D
F
E
N
C
E
(E
)
6
'
W
O
O
D
F
E
N
C
E
(N)
200AMP SUB-PANEL
(E)
GAS METER
(E)WATER
METER
DITTMAR DR.
23
'
-
5
"
23'-7"
11'-10"
SCALE: 1/8" = 1'-0"
EXISTING FLOOR PLAN
SCALE: 1/8" = 1'-0"
PROPOSED FLOOR PLAN
NORTH NORTH A1.1
EXISTING SITE PLAN
&
PROPOSED SITE PLAN
REVISION
01-23
CARLOS PEREZ-RAMIREZ - DESIGNER
RESTRICTIVE NOTICE:
ALL DESIGN, IDEAS, DETAILS, PLANS AND
SPECIFICATIONS INDICATED BY THE DRAWINGS ARE
THE EXCLUSIVE PROPERTY OF FS DESIGN GROUP, THE
PLANS WERE CREATED AND DEVELOPED FOR USE ON
AND IN CONJUNCTION WITH THE SPECIFIC PROJECT
DESCRIBED HEREIN. NOT PART THEREOF SHALL BE
REPRODUCED, COPIED, ADAPTED, MODIFIED OR
DISTRIBUTE TO OTHERS WITHOUT PRIOR WRITTEN
AND SPECIFIC CONSENT OF FS DESIGN GROUP
CPR
1/8" = 1'-0"
C: 626.780.0228
E: CPRSTUDIOOO@GMAIL.COM
CPR
STUDIO
CARLOS PEREZ-RAMIREZ
NO.REVISION
DATE
SCALE
DRAWN BY
JOB NO
GA
R
C
I
A
R
E
S
I
D
E
N
C
E
30
3
7
7
C
U
P
E
N
O
L
N
,
T
E
M
E
C
U
L
A
,
C
A
.
9
2
5
9
2
12/03/2024
GARAGE
8'-0"
C.L.G
BEDROOM
VAULTED
BEDROOM
VAULTED
BEDROOM
VAULTED
KITCHEN
HALLWAY
C.L.G
8'-0"
LIVING ROOM
VAULTED
DINING SPACE
VAULTED
SUNROOM
TO BE
REMOVED
WIC
PARTITION WALL
TO BE REMOVED
GARAGE
8'-0"
C.L.G
BEDROOM
VAULTED
BEDROOM
VAULTED
BEDROOM
VAULTED
KITCHEN
KITCHEN
ADDITION
VAULTED
KITCHEN
ISLAND
HALLWAY
C.L.G
8'-0"
LIVING ROOM
VAULTED
DINING SPACE
VAULTED
WIC
SCALE: 1/4" = 1'-0"
EXISTING FLOOR PLAN
EXISTING WALL
NEW FRAME WALLS W/ STUDS @ 16" O.C. 5/8" DRYWALL @
INTERIOR & 7/8" STUCCO @ EXTERIOR
BUILDING STANDARD DUPLEX OUTLET
SDSMOKE DETECTOR (CARBON MONOXIDE) HARD WIRE 110 VOLTS
INTER CONNECTED WITH BATTERY BACK-UP.
SINGLE POLE LIGHT SWITCH.
RECESSED LIGHT FIXTURE
FLUORESCENT LIGHT FIXTURE F
GFCI PROTECTED OUTLETS IN BATHROOMS. (PROVIDE AT LEAST ONE
20 AMPERE BRANCH CIRCUIT TO SUPPLY BATHROOM RECEPTACLES.
THE BRANCH CIRCUIT SHALL ONLY SUPPLY OUTLETS LOCATED IN THAT
ROOM. SECTION 210.11 (C) (3) 2013.)
TO BE DEMO
CMCARBON MONOXIDE
ARC FAULT CIRCUIT INTERCEPTOR
GFI
AFCI
SINGLE POLE LIGHT SWITCH.
D
SINGLE POLE LIGHT SWITCH.
MS
SYMBOL LEGEND
WALL MOUNTED FIXTURE
ENERGY STAR EXHAUST FAN WITH
HUMIDISTAT CONTROL DUCTED TO
TERMINATE TO THE OUTSIDE OF THE
BUILDING, TYP ALL BATHS & TOILETS
F
FLOOR MOUNTED DUPLEX OUTLET
10" SOLATUBE
INSTALLATION PER MANUFACTURE
SCALE: 1/8" = 1'-0"
PROPOSED FLOOR PLAN
NORTH NORTH A2.0
EXISTING FLOOR PLAN
REVISION
01-23
CARLOS PEREZ-RAMIREZ - DESIGNER
RESTRICTIVE NOTICE:
ALL DESIGN, IDEAS, DETAILS, PLANS AND
SPECIFICATIONS INDICATED BY THE DRAWINGS ARE
THE EXCLUSIVE PROPERTY OF FS DESIGN GROUP, THE
PLANS WERE CREATED AND DEVELOPED FOR USE ON
AND IN CONJUNCTION WITH THE SPECIFIC PROJECT
DESCRIBED HEREIN. NOT PART THEREOF SHALL BE
REPRODUCED, COPIED, ADAPTED, MODIFIED OR
DISTRIBUTE TO OTHERS WITHOUT PRIOR WRITTEN
AND SPECIFIC CONSENT OF FS DESIGN GROUP
CPR
1/8" = 1'-0"
C: 626.780.0228
E: CPRSTUDIOOO@GMAIL.COM
CPR
STUDIO
CARLOS PEREZ-RAMIREZ
NO.REVISION
DATE
SCALE
DRAWN BY
JOB NO
NOTE:
SMOKE ALARM AND DETECTORS WILL BE INSTALLED
AND MAINTAINED ACCORDING TO MANUFACTURER'S
INSTRUCTIONS.
A2
GA
R
C
I
A
R
E
S
I
D
E
N
C
E
30
3
7
7
C
U
P
E
N
O
L
N
,
T
E
M
E
C
U
L
A
,
C
A
.
9
2
5
9
2
12/03/2024
GARAGE
8'-0"
C.L.G
BEDROOM
VAULTED
BEDROOM
VAULTED
BEDROOM
VAULTED
KITCHEN
KITCHEN
ADDITION
KITCHEN
ISLAND
HALLWAY
C.L.G
8'-0"
LIVING ROOM
VAULTED
DINING SPACE
VAULTED
22
'
-
8
"
3'-3"3'-3"1'-8"
2'
-
7
"
2'
-
1
0
"
17
'
-
3
"
3'-6"3'-6"
15'-2"
22
'
-
0
"
2'
-
1
0
"
17
'
-
3
"
1'
-
1
1
"
WIC
(N)EXHAUST HOOD 30"
ABOVE COOKING
SURFACE 100 CFM AT
KITCHEN STOVE
DOOR SCHEDULE
SYM.SIZE GLASSFUNCTION NOTESTYPEMATERIAL
GLASS
HOLLOW GLASS BLOCK
GLAZING
DOOR NOTES:
1. NEW DOORS SHALL BE "COLONIST" 6 PANEL REFINISHED AND PREHUNG UNLESS DIRECTED OTHERWISE BY THE OWNER.
2. GLASS IN INGRESS AND EGRESS DOORS SHALL BE TEMPERED.
3. ALL EXTERIOR DOORS SHALL BE FULLY WEATHER STRIPPED
4. PROVIDE SINGLE CYLINDER DEADBOLT ON EXTERIOR DOORS.
5. INTERIOR DOORS SHALL HAVE ONE PAIR 3 1/2" STANLEY HINGES WITH BRASS FINISH. VERIFY W/ OWNER.
6. EXTERIOR DOORS SHALL HAVE 1 1/2 PAIR 4" STANLEY RD-741 HINGES WITH BRASS FINISH. VERIFY W/ OWNER.
7. INTERIOR DOOR LATCHES SETS AND TRIM SHALL BE SELECTED BY OWNER.
8. ALL HARDWARE SHALL BE INSTALLED COMPLETE WITH ALL ACCESSORIES I.E. SCREWS, STRIKES ETC. AND DOORS SET TRUE AND SQUARE TO ITS JAMB.
FLOOR PLAN NOTES
DIMENSIONS - ALL DIMENSIONS ARE TO FACE OF STUD
(F.O.S.), FACE OF BLOCK (F.O.B.), OR FACE OF CONCRETE
(F.O.C.) UNLESS NOTED OTHERWISE.
SPRINKLERS - BUILDING IS SPRINKLED
THROUGHOUT
STRUCTURAL - FRAMING MEMBERS AND FOUNDATION
LAYOUT SHOWN IN FLOOR PLANS ARE FOR REFERENCE
ONLY. REFER TO STRUCTURAL FRAMING AND FOUNDATION
PLANS FOR ACTUAL FRAMING SIZES, DIRECTIONS,
FOUNDATION SIZES AND SPECIFICATIONS.
MECHANICAL - HVAC DUCTS AND EQUIPMENT SHOWN IN
FLOOR PLANS ARE FOR REFERENCE ONLY. REFER TO
MECHANICAL PLANS FOR ACTUAL DUCT SIZES AND
LOCATIONS.
DOORS - FOR DOOR SCHEDULE
WINDOWS - FOR WINDOW SCHEDULE
SMOKE DETECTORS - FOR LOCATIONS SEE ELECTRICAL
PLANS.
CARBON MONOXIDE SENSORS - FOR LOCATIONS SEE
ELECTRICAL PLANS.
SCALE: 1/4" = 1'-0"
PROPOSED FLOOR PLAN- ADU
(LOW E) DUAL
EXISTING WALL
NEW FRAME WALLS W/ STUDS @ 16" O.C. 5/8" DRYWALL @
INTERIOR & 7/8" STUCCO @ EXTERIOR
BUILDING STANDARD DUPLEX OUTLET
SDSMOKE DETECTOR (CARBON MONOXIDE) HARD WIRE 110 VOLTS
INTER CONNECTED WITH BATTERY BACK-UP.
SINGLE POLE LIGHT SWITCH.
RECESSED LIGHT FIXTURE
FLUORESCENT LIGHT FIXTURE F
GFCI PROTECTED OUTLETS IN BATHROOMS. (PROVIDE AT LEAST ONE
20 AMPERE BRANCH CIRCUIT TO SUPPLY BATHROOM RECEPTACLES.
THE BRANCH CIRCUIT SHALL ONLY SUPPLY OUTLETS LOCATED IN THAT
ROOM. SECTION 210.11 (C) (3) 2013.)
TO BE DEMO
CMCARBON MONOXIDE
ARC FAULT CIRCUIT INTERCEPTOR
GFI
AFCI
SINGLE POLE LIGHT SWITCH.
D
SINGLE POLE LIGHT SWITCH.
MS
SYMBOL LEGEND
WALL MOUNTED FIXTURE
F
FLOOR MOUNTED DUPLEX OUTLET
2.00.01
2.00.02
2.00.03
12 X 12 PLUMBING ACCESS
72" HIGH NON-ABSORBENT
1.5" MAX THRESHOLD TO LANDING BELOW
ELECTRICAL PLAN KEYNOTES
APPLIANCE BRANCH CIRCUITS
R TANK LESS WATER HEATER DEDICATED CIRCUIT 15 AMP | 120 VOLT CONNECTION -
(1) WALL RECEPTACLE OR HARD WIRED REQUIRES ON/OFF SWITCH
APPLIANCE BRANCH CIRCUITS NOTES
1 REQUIREMENTS - VERIFY ELECTRICAL
REQUIREMENTS OF ALL APPLIANCES WITH MANUFACTURERS' RECOMMENDATIONS.
2 ROUGH-IN - LOCATE ELECTRICAL RECEPTACLES AND CONNECTIONS PER
MANUFACTURERS' RECOMMENDATIONS.
3 DOCUMENTS - THE LIGHTING PLAN IS NOT INTENDED TO REPRESENT A COMPLETE SET OF
ELECTRICAL DRAWINGS. EXCEPT WHERE INDICATED OTHERWISE, THE LOCATION AND
SELECTION OF ANY ELECTRICAL REQUIREMENTS NOT DIRECTLY RELATED TO THE
LIGHTING SHALL BE BY OTHERS.
4 ENGINEERING - ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL WORK DESIGN BUILD.
ALL WORK TO BE PERFORMED IN COMPLIANCE WITH ALL LAWS AND APPLICABLE CODES.
ADDITIONAL NOTES:
THE CONSTRUCTION SHALL NOT RESTRICT A
FIVE FOOT CLEAR AND UNOBSTRUCTED ACCESS
TO ANY WATER OR POWER DISTRIBUTION
FACILITIES (POWER POLES, PULL BOXES,
TRANSFORMERS, VAULTS, PUMPS, VALVES,
METERS, APPURTENANCES,ETC.) OR TO THE
LOCATION OF THE HOOK UP. THE CONSTRUCTION
SHALL NOT BE WITHIN TEN FEET OF ANY POWER
LINES WETHER OR NOT THE LINES ARE LOCATED
ON PROPERTY. FAILURE TO COMPLY MAY CAUSE
CONSTRUCTION DELAYS OR ADDITIONAL
EXPENSES.
ARCHITECTURAL PAINTS AND COATINGS,
ADHESIVES, CAULKS, AND SEALANTS SHALL
COMPLY WITH THE V.O.C. LIMITS LISTED IN
TABLES 4.504.1-4.504.3
APPROVED SEISMIC GAS SHUT OFF VALVE WILL
BE INSTALLED ON THE FUEL GAS LINE ON THE
DOWN STREAM SIDE OF THE UTILITY METER AND
BE RIGIDLY CONNECTED TO THE EXTERIOR OF
HOUSE CONTAINING THE FUEL GAS PIPING
ENERGY STAR EXHAUST FAN WITH HUMIDISTAT
CONTROL DUCTED TO TERMINATE TO THE
OUTSIDE OF THE BUILDING, TYP ALL BATHS &
TOILETS
ALL PLUMBING FIXTURES TO BE CONNECTED TO
A SANITARY SEWER
ALL NEW FIXTURES TO COMPLY WITH CBC
WATER USAGE REQ'S.- SEE A1.3
FLOW RATES FOR ALL PLUMBING FIXTURES
SHALL COMPLY WITH THE MAXIMUM FLOW RATES
IN TABLE 4.303.2
SINK OUTLET SHALL BE PROVIDED WITH HOT AND
COLD WATER AND CONNECTED TO AN
APPROVED WATER SUPPLY
LAUNDRY OUTLET SHALL BE PROVIDED WITH HOT
AND COLD WATER AND CONNECTED TO AN
APPROVED WATER SUPPLY
ALL SMOKE ALARMS TO RECEIVE PRIMARY
POWER SOURCE FROM BUILDING WIRING AND
EQUIPPED WITH BATTERY BACK UP AND LOW
BATTERY SIGNAL
EACH APPLIANCE PROVIDED AND INSTALLED
SHALL MEET ENERGY STAR IF AN ENERGY STAR
DESIGNATION IS APPLICABLE FOR THE
APPLIANCE
ALL DUCT AND OTHER RELATED AIR
DISTRIBUTION COMPONENT OPENINGS SHALL BE
COVERED WITH TAPE, PLASTIC,OR SHEET METAL
UNTIL THE FINAL START UP OF THE
HEATING,COOLING AND VENTILATING EQUIPMENT
FINISHI MATERIAL POLLUTANT CONTROL SEC. 4.504.2.
FINISH MATERIAL POLLUTANT CONTROL: THE FOLLOWING FINISH
MATERIALS SHALL COMPLY WITH THE VOC CONTENT LIMITS
SET FORTH IN CALGREEN SECTIONS 4.504.2 THROUGH 4.504.5:
- ADHESIVES, SEALANTS AND CAULKS, PAINTS AND COATINGS,
CARPET SYSTEMS, CUSHIONS AND ADHESIVE, RESILIENT
FLOORING, AND COMPOSITE WOOD PRODUCTS USED IN THE
INTERIOR OR EXTERIOR.
NOTE:
CONSTRUCTION WASTE SHALL BE REDUCED BY 50%. CONSTRUCTION WASTE WILL BE
HANDLED BY A CITY OF LOS ANGELES CERTIFIED HAULER.
WATER CLOSETS
SINGLE SHOWERHEAD
COMBINED SHOWERHEADS
WATER EFFICIENCY AND CONSERVATION
1ST FLOOR
1
LAVATORY FAUCETS
KITCHEN FAUCETS
2
1.28 GPF
2.0 GPM @ 80 PSI
1.2 GPM @ 60 PSI
1.8 GPM @ 60 PSI
2.0 GPM @ 80 PSI 0
3
1
NOTE:
-NEW HARDWIRED SMOKE DETECTORS SHALL BE
INSTALLED IN SERIES SO ALL DETECTION EQUIPMENT
OPERATES SIMULTANEOUSLY.
NOTE:
SMOKE ALARM SHALL BE INTERCONNECTED
HARD-WIRED WITH BATTERY BACKUP AND SHALL BE
INSTALLED IN ACCORDANCE WITH NFPA 72
NOTE:
CARBON MONOXIDE ALARM SHALL BE INTERCONNECTED
HARD-WIRED WITH BATTERY BACKUP
NOTE:
OPENINGS SHALL HAVE CORROSION-RESISTANT WIRE
MESH OR OTHER APPROVED MATERIAL WITH 1/16-IN.
MINIMUM AND 1/4-IN. MAXIMUM OPENING
10" SOLATUBE
INSTALLATION PER MANUFACTURE
2'-10" x 6'-8"1 INTERIOR MANUFACTURER:
JELD - WEN,
COLOR: WHITE
NOTE: WINDOWS TO BE DOUBLE GLASS
MIN. U-VALVE = 0.75, ALL
WINDOWS SHALL BE DUAL PANEL
LOW "E", USE SAFETY GLAZING
MATERIAL (TEMPERED GLASS)
NOTE: HARDWARE INCLUDES LOCK SET AND HINGES (AND
WEATHER STRIP FOR EXTERIOR DOORS). ALL
WINDOWS ARE VINYL MILGARD BRAND OR EQUAL
UNLESS OTHERWISE NOTED. HC=HOLLOW CORE,
SC=SOLID CORE, XO=HORIZONTAL SLIDER, G=GRIDS,
CLR=CLEAR, OBS=OBSCURE, AL=ALUMINUM, VY=VINYL,
INS=INSULATED, FR=FIRE RATED.
NOTE:
THE NFRC TEMPORARY LABEL DISPLAYED ON
WINDOWS AND SKYLIGHTS 9INCL. TUBLAR)
MUST REMAIN ON THE UNIT UNTIL FINAL
INSPECTION HAS BEEN COMPLETED.
MAXIMUM U-FACTOR 0.30 | MAXIMUM SHGC: 0.21 WINDOW SCHEDULE
SYM.
3'-6" x 3'-0"
SIZE FUNCTION
A SINGLE HUNG
NOTES
FOR ATTIC MOUNTED MECHANICAL EQUIPMENT, PROVIDE ACCESS
AND CONVENIENCE FEATURES: [CRC R807, CMC 304.4]
a.CONTINUOUS SOLID SURFACE PASSAGEWAY, 24" WIDE.
b.WORKING PLATFORM, 30" X 30" IN FRONT OF THE
EQUIPMENT.
c. LIGHTING AND CONVENIENCE ELECTRICAL OUTLET.
SOLID CORE PRIMED COMPOSITE
A2.1
PROPOSED FLOOR PLAN
REVISION
01-23
CARLOS PEREZ-RAMIREZ - DESIGNER
RESTRICTIVE NOTICE:
ALL DESIGN, IDEAS, DETAILS, PLANS AND
SPECIFICATIONS INDICATED BY THE DRAWINGS ARE
THE EXCLUSIVE PROPERTY OF FS DESIGN GROUP, THE
PLANS WERE CREATED AND DEVELOPED FOR USE ON
AND IN CONJUNCTION WITH THE SPECIFIC PROJECT
DESCRIBED HEREIN. NOT PART THEREOF SHALL BE
REPRODUCED, COPIED, ADAPTED, MODIFIED OR
DISTRIBUTE TO OTHERS WITHOUT PRIOR WRITTEN
AND SPECIFIC CONSENT OF FS DESIGN GROUP
CPR
1/8" = 1'-0"
C: 626.780.0228
E: CPRSTUDIOOO@GMAIL.COM
CPR
STUDIO
CARLOS PEREZ-RAMIREZ
NO.REVISION
DATE
SCALE
DRAWN BY
JOB NO
ENERGY STAR RATED EXHAUST FAN (MINIMUM 50 CFM WITH
HUMIDISTAT CAPABLE OF AN ADJUSTMENT BETWEEN 50
AND 80% HUMIDITY, CONTROL DUCTED TO TERMINATE TO
THE OUTSIDE OF THE BUILDING, TYP ALL BATHS & TOILETS -
EXHAUST FANS SHALL BE SWITCHED SEPARATELY FROM
LIGHTING SYSTEM. LIGHTING INTEGRAL TO AN EXHAUST
FAN MAY BE ON THE SAME SWITCH AS THE FAN
PROVIDED THE LIGHTING CAN BE SWITCHED OFF WHILE
ALLOWING THE FAN TO CONTINUE TO OPERATE FOR AN
EXTENDED PERIOD OF TIME. (150(K)2B CEC) EXHASUT
FANS SHALL HAVE A MINIMUM VENTILATION RATE OF 50
CFM FOR INTERMITTENT VENTILATION AND 25 CFM OF
CONTINOUS VENTILATION AND VENTED DIRECTLY TO THE
OUTSIDE (R303.3 CRC, 4.506.1 CGBSC)
A1
NOTE:
-SMOKE DETECTORS SHALL BE A MINIMUM OF 3 FT FROM
BATHROOMS.
11
A A
2.00.03
2.00.03
GA
R
C
I
A
R
E
S
I
D
E
N
C
E
30
3
7
7
C
U
P
E
N
O
L
N
,
T
E
M
E
C
U
L
A
,
C
A
.
9
2
5
9
2
12/03/2024
EXISTING
NEW
EXISTING
NEW
12
'
-
7
"
CEILING
4'
-
9
"
FINISH FLOOR
VAULTED
EXISTING
NEW
12
'
-
7
"
CEILING
4'
-
9
"
FINISH FLOOR
VAULTED
EXISTING
NEW
12
'
-
7
"
CEILING
4'
-
9
"
FINISH FLOOR
VAULTED
6:12
SLOPE
6:12
SLOPE
6:12
SLOPE
6:12
SLOPE
6:12
SLOPE
6:12
SLOPE
6:
1
2
SL
O
P
E
6:
1
2
SL
O
P
E
MATCH
EXISTING
VERIFY VERIFY
VERIFY VERIFY
VERIFY
VERIFY
MATCH
EXISTING
(N)
TRIM
MATCH EXISTING
(N)
WINDOW,PER PLAN
MATCH EXISTING
(N)
WOOD SILL
MATCH EXISTING
WEEP SCREED
2X STUDS @ 16" O.C.
R-15 INSULATION
4 X HDR WHERE OCCURS
(N) 7/8" EXT. STUCCO
OVER WIRE FABRIC
LATH OVER 2 LAYERS
TYPE "D" BUILDING
PAPER OVER PLYWOOD
(TO MATCH EXISTING)
1/2" DRYWALL
2 X 6 ROOF RAFTER
3
SD-5
3
SD-5
KITCHEN CABINETS
1
REFER TO
FOUNDATION PLAN
(SHEET SD-2)
SD-2
SCALE: 1/4" = 1'-0"
NORTH ELEVATION
SCALE: 1/4" = 1'-0"
SOUTH ELEVATION
SCALE: 1/4" = 1'-0"
EAST ELEVATION
SCALE: 1/4" = 1'-0"
WEST ELEVATION
(N)ROOF: CLASS A FIRE RESISTANCE CERTAIN TEED 30
YEAR ASPHALT SHINGLES, OVER ONE LAYER OF 30# FELT
PAPER OVER 1/2" APPROVED ROOF SHTNG. (CDX OR OSB)
W/ RADIANT BARRIER, W/ 8D NAILS @6,6,12 , INSTALLATION
SHALL BE IN ACCORDANCE WITH MANUFACTURER'S
SPECIFICATIONS ROOF PITCH: 4/ 12 MAX (ICC# ESR-1389)
(N)7/8" EXT. STUCCO OVER WIRE FABRIC LATH OVER 2
LAYERS TYPE "D" BUILDING PAPER OVER PLYWOOD
(TO MATCH EXISTING)
SYMBOL LEGEND
1
2
2
SCALE: 1/8" = 1'-0"
PROPOSED ROOF PLAN
NEW
1
2 NEW1
2 NEW1
A3.1
PROPOSED
ELEVATIONS/ROOF PLAN
REVISION
01-23
CARLOS PEREZ-RAMIREZ - DESIGNER
RESTRICTIVE NOTICE:
ALL DESIGN, IDEAS, DETAILS, PLANS AND
SPECIFICATIONS INDICATED BY THE DRAWINGS ARE
THE EXCLUSIVE PROPERTY OF FS DESIGN GROUP, THE
PLANS WERE CREATED AND DEVELOPED FOR USE ON
AND IN CONJUNCTION WITH THE SPECIFIC PROJECT
DESCRIBED HEREIN. NOT PART THEREOF SHALL BE
REPRODUCED, COPIED, ADAPTED, MODIFIED OR
DISTRIBUTE TO OTHERS WITHOUT PRIOR WRITTEN
AND SPECIFIC CONSENT OF FS DESIGN GROUP
CPR
1/8" = 1'-0"
C: 626.780.0228
E: CPRSTUDIOOO@GMAIL.COM
CPR
STUDIO
CARLOS PEREZ-RAMIREZ
NO.REVISION
DATE
SCALE
DRAWN BY
JOB NO
SCALE: 1/2" = 1'-0"
WINDOW ELEVATION
SCALE: 1/4" = 1'-0"
PROPOSED ROOF PLAN
GA
R
C
I
A
R
E
S
I
D
E
N
C
E
30
3
7
7
C
U
P
E
N
O
L
N
,
T
E
M
E
C
U
L
A
,
C
A
.
9
2
5
9
2
12/03/2024
GARAGE
8'-0"
C.L.G
BEDROOM
VAULTED
BEDROOM
VAULTED
BEDROOM
VAULTED
KITCHEN
KITCHEN
ADDITION
KITCHEN
ISLAND
HALLWAY
C.L.G
8'-0"
LIVING ROOM
VAULTED
DINING SPACE
VAULTED
WIC
SVS
F FF
F FF
F FF
WR
GFCI
W.H.
WR
GFCI
GFI
GFI
GFI GFIGFI
GFI GFI
NOTE: WINDOWS TO BE DOUBLE GLASS
MIN. U-VALVE = 0.75, ALL
WINDOWS SHALL BE DUAL PANEL
LOW "E", USE SAFETY GLAZING
MATERIAL (TEMPERED GLASS)
NOTE: HARDWARE INCLUDES LOCK SET AND HINGES (AND
WEATHER STRIP FOR EXTERIOR DOORS). ALL
WINDOWS ARE VINYL MILGARD BRAND OR EQUAL
UNLESS OTHERWISE NOTED. HC=HOLLOW CORE,
SC=SOLID CORE, XO=HORIZONTAL SLIDER, G=GRIDS,
CLR=CLEAR, OBS=OBSCURE, AL=ALUMINUM, VY=VINYL,
INS=INSULATED, FR=FIRE RATED.
NOTE:
THE NFRC TEMPORARY LABEL DISPLAYED ON
WINDOWS AND SKYLIGHTS (10INCL. TUBLAR)
MUST REMAIN ON THE UNIT UNTIL FINAL
INSPECTION HAS BEEN COMPLETED.
MAXIMUM U-FACTOR 0.30 | MAXIMUM SHGC: 0.21
DOOR NOTES:
1. NEW DOORS SHALL BE "COLONIST" 6 PANEL REFINISHED AND PREHUNG UNLESS DIRECTED OTHERWISE BY THE OWNER.
2. GLASS IN INGRESS AND EGRESS DOORS SHALL BE TEMPERED.
3. ALL EXTERIOR DOORS SHALL BE FULLY WEATHER STRIPPED
4. PROVIDE SINGLE CYLINDER DEADBOLT ON EXTERIOR DOORS.
5. INTERIOR DOORS SHALL HAVE ONE PAIR 3 1/2" STANLEY HINGES WITH BRASS FINISH. VERIFY W/ OWNER.
6. EXTERIOR DOORS SHALL HAVE 1 1/2 PAIR 4" STANLEY RD-741 HINGES WITH BRASS FINISH. VERIFY W/ OWNER.
7. INTERIOR DOOR LATCHES SETS AND TRIM SHALL BE SELECTED BY OWNER.
8. ALL HARDWARE SHALL BE INSTALLED COMPLETE WITH ALL ACCESSORIES I.E. SCREWS, STRIKES ETC. AND DOORS SET TRUE AND SQUARE TO ITS JAMB.
GLASS:
1. TO COMPLY WITH THE LOS ANGELES COUNTY SECURITY ORDINANCE. ANY
GLASS IN DOORS OR IN SIDELITE(S) WITHIN 24" OF EITHER DOOR EDGE PER
2016 CBC, SEC. 2406.4(6) OR WITHIN 40" OF ANY LOCKING MECHANISM
(PER CITY OF LOS ANGELES ORDINANCE) SHALL BE FULLY TEMPERED.
2. THE MANUFACTURED WINDOWS SHALL HAVE A LABEL ATTACHED CERTIFIED
BY THE NATIONAL FENESTRATION RATING COUNCIL (NFRC) AND SHOWING
COMPLIANCE WITH ENERGY CALCULATIONS.
KEYNOTE
SCALE: 1/4" = 1'-0"
SYMBOL LEGEND
2.00.01
2.00.02
2.00.03
12 X 12 PLUMBING ACCESS
72" HIGH NON-ABSORBENT
1" MAX THRESHOLD TO LANDING BELOW
NOTE:
THE PANEL OR SUB-PANEL SHALL PROVIDE A CAPACITY TO INSTALL A 40-AMPERE MINIMUM
DEDICATED BRANCH CIRCUIT AND SPACE(S) RESERVED TO PERMIT INSTALLATION OF A
BRANCH CIRCUIT OVER CURRENT PROTECTIVE DEVICE
NOTE:
THE ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR
INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE SOLAR ELECTRIC
INSTALLATION. THE RESERVES SPACE SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END
FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION AND SHALL BE
PERMANENTLY MARKED AS "FOR FUTURE SOLAR ELECTRIC"
NOTE:
NEW ELECTRICAL SERVICE PANEL LOAD NOT TO EXCEED 400 AMPS 120/240V
NOTE:
ALL LUMINAIRES SHALL BE HIGH EFFICACY AND SHALL BE CONTROLLED BY AN OCCUPANCY
OR VACANCY SENSOR.
HABITABLE SPACES. ALL LUMINAIRES SHALL BE HIGH EFFICACY AND SHALL BE CONTROLLED
BY A VACANCY/OCCUPANCY SENSOR OR DIMMER.
HIGH EFFICACY LUMINAIRES MUST BE PIN BASED.
WALLS 2 FEET WID OR GREATER HALL HAVE AN OUTLET. OUTLETS SHALL BE SPACED NO
MORE THAN 12 FEET APPART AND A MAXIMUM OF 6 FEET FROM END OF WALLS OR OPENING.
SURFACE MOUNTED LIGHTING FIXTURES IN CLOSETS MUST BE 18 INCHES FROM STORAGE
AREA (S). FLUSH MOUNTED MUST BE 6 INCHES AWAY.
ELECTRICAL PLAN KEYNOTES
APPLIANCE BRANCH CIRCUITS
R TANK LESS WATER HEATER DEDICATED CIRCUIT 15 AMP | 120 VOLT CONNECTION -
(1) WALL RECEPTACLE OR HARD WIRED REQUIRES ON/OFF SWITCH
APPLIANCE BRANCH CIRCUITS NOTES
1 REQUIREMENTS - VERIFY ELECTRICAL
REQUIREMENTS OF ALL APPLIANCES WITH MANUFACTURERS' RECOMMENDATIONS.
2 ROUGH-IN - LOCATE ELECTRICAL RECEPTACLES AND CONNECTIONS PER
MANUFACTURERS' RECOMMENDATIONS.
3 DOCUMENTS - THE LIGHTING PLAN IS NOT INTENDED TO REPRESENT A COMPLETE SET OF
ELECTRICAL DRAWINGS. EXCEPT WHERE INDICATED OTHERWISE, THE LOCATION AND
SELECTION OF ANY ELECTRICAL REQUIREMENTS NOT DIRECTLY RELATED TO THE
LIGHTING SHALL BE BY OTHERS.
4 ENGINEERING - ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL WORK DESIGN BUILD.
ALL WORK TO BE PERFORMED IN COMPLIANCE WITH ALL LAWS AND APPLICABLE CODES.
ELECTRICAL NOTES PER 2016 CALIFORNIA ELECTRICAL CODE
A.PANEL LOCATIONS
PANELS SHALL NOT BE LOCATED IN THE VICINITY OF EASILY IGNITABLE MATERIAL, SUCH AS
CLOTHES CLOSETS, OR IN BATHROOMS (CEC 240-24D)
B.NON-METALLIC SHEATHED CABLE (CEC 334)
NON-METALLIC SHEATHED CABLE SHALL BE:
1.PROTECTED BY RIGID METAL CONDUIT INTERMEDIATE METAL CONDUIT, ELECTRICAL
METALLIC TUBING, SCHEDULE 80 PVC CONDUIT, PIPE, OR OTHER MEANS WHEN CABLE IS
EXPOSED OR SUBJECT TO PHYSICAL DAMAGE. (CEC 334.15B)
2.PROTECTED BY A 1
16 " STEEL PLATE OR SLEEVE, OR BE NOT LESS THAN 1-1/4" FROM THE
NEAREST EDGE OF THE FRAMING MEMBER, WHEN INSTALLED THROUGH FRAMING
MEMBERS. STEEL PLATES OR SLEEVES ARE REQUIRED ON ALL DOUBLE SHEAR WALL S
SHEN CABLE IS INSTALLED EITHER THROUGH A PARALLEL TO FRAMING MEMBERS (CEC
334.17)
3.PROTECTED BY GUARD STRIPS WITHIN 6 FEET OF AN ATTIC ACCESS WHEN NO
PERMANENT STAIRS OR LADDERS ARE PROVIDED(CEC 334.23 320.23)
4.PROTECTED BY GUARD STRIPS IN THE ENTIRE ATTIC WHEN PERMANENT STAIRS OR
LADDERS ARE PROVIDED. ACCESS PANELS OR DOORS FROM THE SECOND FLOOR INTO
THE ATTIC ARE CONSIDERED PERMANENT ACCESS AND GUARD STRIPS REQUIRED IN THE
ENTIRE ATTIC.
5.HAVE A BENDING RADIUS NOT LESS THAN 5 TIMES THE DIAMETER OF THE CABLE
(CEC334.24)
6.SUPPORTED AT INTERVALS NOT EXCEEDING 4-1/2" FEET AND WITHIN 12" OF EVERY
OUTLET BOX, JUNCTION BOX, CABINET FOR FITTING (CEC 334.30)
C.CIRCUITS AND RECEPTACLES
1.RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT ALONG THE FLOOR LINE IN ANY
WALL SPACE IS MORE THAN 6FT. FROM AN OUTLET, INCLUDING ANY WALL SPACE 2FT.
WIDE OR GREATER. NOTE: A FIXED PANEL OF A SLIDING GLASS DOOR IS CONSIDERED
WALL SPACE (CEC 210.52A)
2.IN KITCHENS, BREAKFAST ROOMS, PANTRIES AND DINING ROOMS A MINIMUM OF 2-20A
CIRCUITS SHALL BE PROVIDED (CEC 210.11C1)
COUNER SPACE RECEPTACLES SHALL BE GFC (CEC 210.8A) AND INSTALLED:
- AT EACH WALL COUNTER SPACE THAT IS 12" OR GREATER (CEC 210.52C1)
- NO MORE THAN 48 IN. OC (CEC 210.52C1)
- MAXIMUM 24 IN FROM THE END OF THE COUNTER (CEC 210.52C1)
- MAXIMUM 20 IN ABOVE COUNTER SURFACE (CEC 210.52C5)
- ON ISLAND COUNTER SPACES (ONE RECEPTACLE MIN) NOT MORE THAN 12 IN. BELOW
COUNTER SURFACE (CEC 210.52C5)EXCEPTION)
AN ISLAND WITH LESS THAN 12" BEHIND A RANGE TOP OF SINK IS CONSIDERED AS
DIVIDING THE COUNTER TOP INTO TWO SEPARATE SPACES (CEC 210.52C2)
- ON PENINSULAR COUNTER SPACES (ONE RECEPTACLE MIN) NOT MORE THAN 12 IN
BELOW COUNTER SURFACE (CEC 210.52C5)EXCEPTION)
3.BATHROOM SHALL HAVE A SEPARATE 20A CIRCUIT (CEC210.11C3) WITH AT LEAST ONE
GFCI WALL RECEPTACLES WITHIN 36 IN OF EACH BASIN (CEC210.8A1) (CEC210.52D)
4.LAUNDRY ROOMS SHALL HAVE A SEPARATE 20A CIRCUIT WITH AT LEAST ONE RECEPTACLE
SHALL BE PROVIDED (CEC 210.11C2) ALL RECEPTACLE WITHIN 6FT. OF THE SINK SHALL BE
GFCI (CEC 210.8A7)
5.IN GARAGES, T LEAST ONE GFCI RECEPTACLE SHALL BE PROVIDED (CEC 210.52G). ALL
OTHER GARAGE RECEPTACLES EXCEPT THOSE DEDICATED TO AN APPLIANCE OR THAT
ARE NOT READILY ACCESSIBLE SHALL BE GFCI. (CEC 210.8A2)
6.IN HALLWAYS OF 10FT. OR MORE IN LENGTH, AT LEAST ONE RECEPTACLE SHALL BE
PROVIDED (CEC 210.52H)
7.OUTDOOR OUTLETS SHALL BE GFCI (CEC 210.83) ONE OUTLET SHALL BE INSTALLED AT THE
FRONT OF THE DWELLING AND ONE AT THE REAR OF THE DWELLING. RECEPTACLES SHALL
BE ACCESSIBLE AT GRADE LEVEL AND NOT MORE THAN 6-1/2 FT. ABOVE GRADE 9CEC
210.52E)
8.ALL CRAWL SPACE RECEPTACLES SHALL BE GFCI (CEC 210.8A4)
9.ALL UNFINISHED BASEMENT RECEPTACLES SHALL BE GFCI UNLESS THEY ARE NOT
READILY ACCESSIBLE OR ARE SERVICE OR ARE SERVICE A DEDICATED APPLIANCE (CEC
210.8A5)
10.ALL RECEPTACLES WITHIN 6 FT. OF A WET BAR SHALL BE GFCI (CEC 210.8A7)
11.ALL RECEPTACLES ON 15A OR 20A BRANCH CIRCUITS THAT SUPPLY FAMILY ROOMS,
DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS , BEDROOMS, SUNROOMS,
RECREATION ROOMS, CLOSETS, HALLWAYS OR SIMILAR ROOMS OR AREAS SHALL E
PROTECTED BY COMBINATION-TYPE ARC-FAULT CIRCUIT INTERRUPTERS (AFCI),
INCLUDING SWITCHED OUTLETS (CEC 210.12B)
12.ALL RECEPTACLES SERVING APPLIANCES OR MOTORS WITH A RATING OF 1HP OR 6 AMPS
SHALL BE ON A SEPARATE CIRCUIT.
13.FOR HVAC EQUIPMENT, A SEPARATE 15A OR 20A CIRCUIT WITH AN ACCESSIBLE
RECEPTACLE AT THE EQUIPMENT SHALL BE PROVIDED WITHIN 25 FT. OF THE EQUIPMENT
(CEC 210.63). IF LOCATED IN AN UNDER FLOOR AREA, THE RECEPTACLE SHALL BE GFCI
(CEC 210.84)
D.LIGHTNING (CEC 210.70)
1.SWITCHED LIGHTNING SHALL BE INSTALLED IN:
- ALL HABITABLE ROOMS, BATHROOMS, HALLWAYS, AND STAIRWAYS AT EACH LEVEL
- GARAGES
- AT ALL OUTDOOR ENTRANCES AND EXITS.
- IN ALL ATTICS, UNDER FLOOR AREAS, UTILITY ROOMS AND BASEMENTS USED FOR
STORAGE
- NEAR HVAC EQUIPMENT IN ATTIC, UNDER FLOOR AREAS, ROOMS OR BASEMENTS,
WITH A SWITCH AT THE ACCESS POINT.
2.LIGHTING INSTALLED IN A CLOSET SHALL BE A SURFACE MOUNTED OR RECESSED
FLUORESCENT FIXTURE OR A SURFACE MOUNTED INCANDESCENT FIXTURE WITH
COMPLETELY ENCLOSED LAMPS OR RECESSED FLUORESCENT FIXTURE WITH
COMPLETELY ENCLOSED LAMPS. SURFACE INCANDESCENT LIGHTING SHALL BE INSTALLED
A MINIMUM OF 12 IN. FROM THE NEAREST POINT OF A STORAGE SPACE. SURFACE
FLUORESCENT LIGHTING AND RECESSED LIGHTING SHALL BE INSTALLED A MINIMUM OF 6
IN. FROM THE NEAREST POINT OF A STORAGE SPACE. (CEC 410.8D)
E.FANS
IN BATHROOMS CONTAINING TUBS OR SHOWERS, A FAN CAPABLE OF EXHAUSTING 50 CFM
SHALL BE INSTALLED (ENERGY STANDARDS150)
F.SMOKE ALARMS
IN A NEW CONSTRUCTION, SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM
THE BUILDING WIRING. THE WIRING SHALL BE PERMANENT AND INSTALLED WITHOUT A
DISCONNECT SWITCH OTHER THAN THOSE REQUIRED FOR OVER CURRENT PROTECTION.
(CRC R314.4)
G. WATER HEATING. SYSTEMS USING GAS OR PROPANE WATER HEATERS TO SERVE INDIVIDUAL
DWELLING UNITS SHALL INCLUDE THE FOLLOWING COMPONENTS [150.0(N)]:
1.A DEDICATED 125V, 20A (10AWG COPPER BRANCH CIRCUIT) ELECTRICAL RECEPTACLE
THAT IS WITHIN 3 FT FROM THE WATER HEATER AND ACCESSIBLE TO THE WATER HEATER
WITH NO OBSTRUCTIONS. THERE SHALL BE A RESERVED SINGLE POLE BREAKER SPACE IN
THE ELECTRICAL PANEL LABELED "FUTURE 240V USE". BOTH ENDS OF THE UNUSED
CONDUCTOR SHALL BE LABELED WITH THE WORD "SPARE" AND BE ELECTRICALLY
ISOLATED.
2.A CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE BASE OF THE
INSTALLED WATER HEATER, AND ALLOWS NATURAL DRAINING WITHOUT PUMP
ASSISTANCE.
3.DESIGNATE A SPACE AT LEAST 2.5FT. BY 2.5FT. WID AND 7 FT. TALL SUITABLE FOR THE
FUTURE INSTALLATION OF A HEAT PUMP WATER HEATER (HPWH).
4.IF DESIGNATED SPACE IS MORE THAN 3 FEET FROM WATER HEATER, COMPLY WITH
150.0(n)B.
WATER CONSERVATION: THE PROJECT SHALL DEMONSTRATE A 20% REDUCTION IN WATER
USE BY SPECIFYING PLUMBING FIXTURES AND FIXTURES THAT MEET THE FLOW RATES
LISTED BELOW, OR THROUGH A CALCULATION SHOWING A 20% REDUCTION FROM BASELINE
VALUES LISTED IN CALGREEN TABLE 4.303.1
SHOWERHEADS: 2.0 GPM
LAVATORY FAUCET - RESIDENTIAL 1.2 GPM
KITCHEN FAUCETS 1.8 GPM
WATER CLOSETS:1.28GPF (GPF = GALLONS PER FLUSH)
URINALS:0.5 GPF
METERING FAUCETS:1.5GPM (GPM = GALLONS PER MINUTE)
NOTE:THE COMBINED FLOW RATE OF MULTIPLE SHOWER HEADS SHALL NOT EXCEED THE
MAXIMUM FLOW RATE, OR THE SHOWER BE DESIGNED TO PERMIT ONE
SHOWERHEAD TO BE IN OPERATION AT A TIME.
THE EFFECTIVE FLUSH VOLUME FOR DUAL-FLUSH TOILETS IS DEFINED AS THE
COMPOSITE, AVERAGE FLUSH VOLUME OF TWO REDUCED FLUSHED AND ONE FULL
FLUSH
2.00.04 DRYER EXHAUST DUCT
A4.0
ELECTRICAL PLAN
SCALE: 1/4" = 1'-0"
ELECTRICAL PLAN MAIN HOUSE ROOM ADDITION
EXISTING WALL
NEW FRAME WALLS W/ STUDS @ 16" O.C. 5/8" DRYWALL @
INTERIOR & 7/8" STUCCO @ EXTERIOR
BUILDING STANDARD DUPLEX OUTLET
SDSMOKE DETECTOR (CARBON MONOXIDE) HARD WIRE 110 VOLTS
INTER CONNECTED WITH BATTERY BACK-UP.
SINGLE POLE LIGHT SWITCH.
RECESSED LIGHT FIXTURE
FLUORESCENT LIGHT FIXTURE F
GFCI PROTECTED OUTLETS IN BATHROOMS. (PROVIDE AT LEAST ONE
20 AMPERE BRANCH CIRCUIT TO SUPPLY BATHROOM RECEPTACLES.
THE BRANCH CIRCUIT SHALL ONLY SUPPLY OUTLETS LOCATED IN THAT
ROOM. SECTION 210.11 (C) (3) 2013.)
TO BE DEMO
CMCARBON MONOXIDE
ARC FAULT CIRCUIT INTERCEPTOR
GFI
AFCI
DIMMER SWITCH CONTROLLED LIGHTING OUTLET
D
SINGLE POLE LIGHT SWITCH.
MS
WALL MOUNTED FIXTURE- LED STYLE - HIGH EFFICACY, BE
MANUALLY ON/OFF SWITCH CONTROLLED, AND HAVE BOTH MOTION
SENSOR AND PHOTOCELL CONTROL.
FLOOR MOUNTED DUPLEX OUTLET
10" SOLATUBE
INSTALLATION PER MANUFACTURE
BUILDING STANDARD DUPLEX OUTLET -WEATHER RESISTANT
TYPE RECEPTACLES (OUTLET)GFI
WR
F
ENERGY STAR RATED EXHAUST FAN (MINIMUM 50 CFM WITH
HUMIDISTAT CAPABLE OF AN ADJUSTMENT BETWEEN 50
AND 80% HUMIDITY, CONTROL DUCTED TO TERMINATE TO
THE OUTSIDE OF THE BUILDING, TYP ALL BATHS & TOILETS -
EXHAUST FANS SHALL BE SWITCHED SEPARATELY FROM
LIGHTING SYSTEM. LIGHTING INTEGRAL TO AN EXHAUST
FAN MAY BE ON THE SAME SWITCH AS THE FAN
PROVIDED THE LIGHTING CAN BE SWITCHED OFF WHILE
ALLOWING THE FAN TO CONTINUE TO OPERATE FOR AN
EXTENDED PERIOD OF TIME. (150(K)2B CEC) EXHASUT
FANS SHALL HAVE A MINIMUM VENTILATION RATE OF 50
CFM FOR INTERMITTENT VENTILATION AND 25 CFM OF
CONTINOUS VENTILATION AND VENTED DIRECTLY TO THE
OUTSIDE (R303.3 CRC, 4.506.1 CGBSC)
INDOOR AIR QUALITY VENTILATION FAN. MODEL: FV-0511VQ1
WHISPER FIT DC FAN. DIMMABLE LED TIH ADJUSTABLE
COLOR TEMPERATURES 110 CFM
NOTE: THIS FAN TO REMAIN ON DURING ALL HOURS THE
HOUSE IS OCCUPIED.
SINGLE POLE LIGHT SWITCH WITH VACANCY SENSOR
VS
REVISION
01-23
CARLOS PEREZ-RAMIREZ - DESIGNER
RESTRICTIVE NOTICE:
ALL DESIGN, IDEAS, DETAILS, PLANS AND
SPECIFICATIONS INDICATED BY THE DRAWINGS ARE
THE EXCLUSIVE PROPERTY OF FS DESIGN GROUP, THE
PLANS WERE CREATED AND DEVELOPED FOR USE ON
AND IN CONJUNCTION WITH THE SPECIFIC PROJECT
DESCRIBED HEREIN. NOT PART THEREOF SHALL BE
REPRODUCED, COPIED, ADAPTED, MODIFIED OR
DISTRIBUTE TO OTHERS WITHOUT PRIOR WRITTEN
AND SPECIFIC CONSENT OF FS DESIGN GROUP
CPR
1/8" = 1'-0"
C: 626.780.0228
E: CPRSTUDIOOO@GMAIL.COM
CPR
STUDIO
CARLOS PEREZ-RAMIREZ
REVISION
GA
R
C
I
A
R
E
S
I
D
E
N
C
E
30
3
7
7
C
U
P
E
N
O
L
N
,
T
E
M
E
C
U
L
A
,
C
A
.
9
2
5
9
2
12/03/2024