HomeMy WebLinkAboutLD25-0856Permit Number: LD25-0856
LD - Onsite Improvements/ Public Work clearance
Issued: 03/05/2025
Expired: 09/01/2025
Job Address: 39748 Larkspur Terrace
Legal Description:
City of Temecula - Land Development Division
41000 Main Street - Temecula, CA 92590
Mailing Address: P.O. Box 9033 Temecula, CA 92589-9033
Phone: (951) 308-6395 Fax: (951) 694-6475
ANY NOTICE OR NOTICES REQUIRED TO BE GIVEN PURSUANT TO THIS PERMIT SHALL BE SERVED
ON THE OTHER PARTY BY FIRST CLASS MAIL, POSTAGE PREPAID, AT THE FOLLOWING ADDRESS:
Matthew Ortwein
31638 Waterfall Way 31638 Waterfall Way
Murrieta, CA 92563
(760) 594-4638
Applicant:
Contractor:
Description:
Inground gunite Pool/Spa with masonry firepit (Natural gas/Non-wood burning)
Permitee Date
City Engineer or Authorized Representative Date
03/05/2025
Page 1 of 1
3-03-2025
Chris White
3-05-2025
CLEARED BY
CITY OF TEMECULA
PUBLIC WORKS
SUBJECT TO BUILDING DEPARTMENT
APPROVAL
PERMITS ARE REQUIRED
Chris.White 03/05/2025
03/05/2025 03/05/2025
03/05/20
Jets:7
Notes:Spa raised 18" with Spillway
Dig Type Shallow
3ft. 6in.3ft. 8in.
9ft.
5ft. 6in.
9ft.
4ft. 8in.
10ft. 5in.
4ft. 6in.
9ft. 7in.
Spa Specs
Style:Geometric Rectangle
Notes:
Skim:1
Pool Specs
Circ Pump:Pentair VS3
Tile Specs
P.C.:
RTNS:4
Control Panel:Intlli5
Deck Specs
Pump #2:Pentair VS
Equipment
Pump #3:
NOTES:2500 psi natural grey broom
finishedw/ 3/8" rebar at 24" Spacing
Filter:Pentair FNS 60
Pool Depth Profile
Heater:MasterT400K
Cleaner:Vac Line1.5"
Pool Light:2 LED Color
Spa Light:1 LED Color
Other:Other:
Other:
Notes:Tier 1-4 up to $8 sqft
Other:
Other:
RTNS:7
Fill Line:Auto Fill
Blower:
Sanitizer:
Type:Geo Square
Remote:SCR.Logic
NOTES:
Lancon Pools
Lic#886118
31638 Waterfall Way
Murrieta Ca. 92563
760-594-4638
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
GA
S
6' 8"
78
'
1
1
"
108' 9"
14
'
1
1
"
2' 4"
GA
S
GA
S
GA
S
GA
S
36
'
1
1
"
7'
211' Gas Line 2" Poly
Yellow
Electric Conduit 1" w/
#6 Wire
60" Tall Side Gate.
Self Closing, Self
Latching, Open
Outward
POOL/SPA Water
Alarms PoolGuard
60 "Tall Iron Fence.
Non-Climbable
60 "tall CMU Block
Wall Non-Climbable
60 "tall CMU Block
Wall Non-Climbable
60 "tall CMU Block
Wall Non-Climbable
20 x 15 Alumawood
Patio Cover
3000 psi #3 Sand
Finsih Concrete
60 "tall CMU Block
Wall Non-Climbable
4'x 7' Masonry Firepit
-NG non-wood
burning. 80,000 BTU
Masonry Seat
Wall/Bench
Outdoor Kitchen/bbq
Masonry/Block w/
gas and electric.
Lion BBQ 60,000 BTU
Gas Line vented and
sleaved under
covered structure
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
electrical electrical electrical electrical electrical electrical electrical electrical electrical electrical electrical electrical electrical electrical
el
e
c
t
r
i
c
a
l
Gas and electrical
main
110v Outlet w/
weatherproof cover
110v Outlet w/
weatherproof cover
110v Outlet w/
weatherproof cover
electrical electrical
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
el
e
c
t
r
i
c
a
l
125' 8"
Rear Access Doors
Equipped with Techno
S187D Pool Alarm
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Existing Drainage Existing Drainage Existing Drainage Existing Drainage Existing Drainage Existing Drainage Existing Drainage Existing Drainage Existing Drainage Existing Drainage Existing Drainage Existing Drainage
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Ex
i
s
t
i
n
g
D
r
a
i
n
a
g
e
Pr
o
p
e
r
t
y
L
i
n
e
Pr
o
p
e
r
t
y
L
i
n
e
Property
L
i
n
e
Property Line
18'
38
'
10'
8'
5'
7
"
10
'
3
"
45' 5"
83' 3"
7' 10"
16' 2"
4
1
'
7
"
21
'
8
"
15' 4"
134' 5"
16
9
'
1
1
"
160' 7"
18
4
'
7
"
53
'
1
0
"
124' 2"
99
'
5
"
Pool
Equipment/Panel
Info/Gas
-Pentair VS Pump
-Pentair 1 hp Whisper
Flo
-Master Temp 400k
BTU Heater NG
-FNS 60 Sqft DE Filter
Easy Touch 4 W/ Salt
Panel 100Amp
Pumps on 20/20 GFCI
Breakers
#6 Wire Run from
Main Panel 40/40
Amp for Pool
2" Poly Yellow Gas
Line
Scale: 1/8" = 1 ft
Project Address:
ERTZ RESIDENCE
39748 LARKSPUR
TERRACE
TEMECULA CA. 92592
NN
POOL
SPA
ERTZ RESIDENCE
Notes:
Project shall comply with the 2024-2025 CRC,CBC,CEC,CMC,CPC,etc..
ELECTRICAL AND GAS
-All underground plastic gas pipes shall have a min. #14 "Yellow Tracer Wire"
-All gas supplied devices shall have a shut off valve per (CPC 1212.6)
-Pipes are part of pool equipment and any pipes emerging from the ground shall not encroach
into the 5' setback or planning variance will be required.
BARRIERS AND ENCLOSURES
Any enclosure shall have the following characteristics
-Any access gate through the enclosure shall open away from the pool and be self closing and self
latching with latching device no lower then 54" above the ground
-A maximum clearance of 2" from ground to bottom of enclosure
-Minimum height of 60"
-Gaps or voids shall not allow passage of a sphere equal to or greater then 4"diameter
-The garage man door shall be self closing and self latchin.
-A thermal cover is required for outdoor pools and spas that have a heatpump or gas heater. 2022
CEC 110.4(b)2
-Any existing lights, electrical or fans within 10' of pool or spa shall be GFCI protected.
-200 amp minimum main service required or add a note that contractor will supply the Building
Inspector with load calculations.
-All metal objects within 5' of waterline will be bonded
Larkspur Terrace
Digitally signed by Christopher Biedenbach on 02/24/2025 - 1740384000 - 25-01510-dg
552
Note
Pool excavation shall be inspected by
soils engineer prior to steel placement.
As a condition of the use of Pool
Engineering, Inc. structural plans, Soils
Engineer shall certify that the pool
bottom conforms to Structural Note 1 on
Standard Pool Structural Plan.
CLEARED BY
CITY OF TEMECULA
PUBLIC WORKS
SUBJECT TO BUILDING DEPARTMENT
APPROVAL
PERMITS ARE REQUIRED
Chris.White 03/05/2025
03/05/2025 03/05/2025
03/05/20
Digitally signed by Christopher Biedenbach on 02/24/2025 - 1740384000 - 25-01510-dg
Digitally signed by Christopher Biedenbach on 02/24/2025 - 1740384000 - 25-01510-dg