Loading...
HomeMy WebLinkAboutParcel Map 28530-1 Lot 22 Hydrology StudyAPPROVED BY CITY OF TEMECULA PUBLIC WORKS david.pina 04/11/2023 04/11/2023 04/11/2023 04/11/20 Table of Contents    Discussion……………………………………………………………………………………………………………………………………………1‐2        Appendix A      Vicinity Map    Hydrologic Soils Group Map    Isohyetal Maps        Appendix B    Rational Method Output (Pre‐developed)      Appendix C    Rational Method Output (Developed)      Appendix D    Hydraulic Design                1 Discussion    The project proposes to re‐develop a 1.08‐acres of a 1.23‐acre site located within an existing  retail development at 26478 Ynez Rd. in the city of Temecula. The site is bounded to the south and west  by an existing paved drive aisle, to the north by an existing retail development, and to the east by the  right‐of‐way of Rind Rd.   Site soils have been identified as Hydrologic Soil Group “B.” The Hydrologic Soils Group Map of  the RCFCD Hydrology Manual indicates a soil group of B and C at the project site. However, the soils  investigation of the project site prepared by Soil Pacific Inc. dated May 25, 2021 describes site soils as  gravel, sand, and thin sandy silt layers. Furthermore, infiltration testing performed by Soil Pacific Inc.  determined a good infiltration rate 4‐in/hr of native soils. This information led to the classification of site  soils as being soil group B.  The project site is currently developed for retail use. Impervious surfaces consist of roofs, AC  pavement, concrete hardscape, and concrete gutters. Existing landscape areas are throughout the site.  The imperviousness of the existing development is 87%. The project site is one drainage area. Storm  water sheets across existing landscape areas, AC pavement, and concrete hardscape in a southwesterly  direction. An existing concrete gutter conveys flows westerly through the project site, discharging at the  site’s westerly boundary into the drive aisle of the retail center. Storm water also sheets across the  southerly boundary of the project site into said drive aisle. At the northwesterly corner of the project  site an existing concrete gutter conveys storm water from the adjacent property westerly through the  corner of the site. These flows from the adjacent property bypass the project site and do not comingle  with site runoff. See the Pre‐Developed Hydrology Map in Appendix B.  The project proposes to re‐develop the site for use as a car wash facility. Proposed  improvements consist of proposed a building structure, awnings, AC pavement, concrete hardscape,  concrete curb, concrete gutter, landscaping, fencing, a trash enclosure structure, two catch basin inlets,   an underground infiltration system, an underwalk drain, and a rip‐rap pad. The imperviousness of the  proposed development will be 84%. The proposed development will mimic the existing drainage  patterns of the property, directing storm flows to the existing drive aisle along the westerly and  southerly boundary of the project site. There is one drainage area within the project limits, further  subdivided into two subareas. Drainage Area A1 consists of the majority of the project site. Storm water  sheets across proposed landscape and AC pavement to be intercepted by a proposed concrete gutter.  This conveys flows southerly and storm water is intercepted by a proposed inlet located at the  southwesterly corner of the site. The inlet discharges flows into the proposed underground infiltration  2 system located in the southerly area of the project site. Drainage Area A2 consists of the northwesterly  corner of the project site. Storm water sheets across proposed landscape and AC pavement to be  intercepted by a proposed inlet located along the westerly boundary of the site. This inlet discharges  flows into the same proposed underground infiltration system as Drainage Area A1. Overflows of the  system pond up in the inlet and sheet across a proposed rip‐rap pad into a proposed underwalk drain  located at the southwesterly corner of the project site. This drain discharges flows into the existing drive  aisle as in the existing condition.   A Rational Study has been prepared for both the pre‐developed and post‐developed conditions  of the project site for a 100‐year storm. See Appendix B and C. The results are as follows:       QPRE TC,PRE QPOST TC,POST ΔV VSTORAGE   (CFS)  (MIN)  (CFS)  (MIN) (CF) (CF)  100‐YR  4.27  6.5  3.42  9.8  ‐750  3,075    The change in run‐off volume due to the proposed development has been calculated as follows:  ΔV = 1.5 (ΔQ) (TC,POST*60)  This formula models an estimation of the change in storm water volume, hence it is multiplied by a  factor of 1.5. The proposed development decreases the impervious footprint as well as increases the  time of concentration, and, thus, the volume of storm water runoff (ΔV) generated decreases from the  volume of the pre‐developed condition of the site. The proposed underground infiltration system will  provide retention of storm water runoff that further reduces the volume of storm water discharge from  the project site.. Therefore, the project will not increase the discharge of stormwater runoff from the  site.    The proposed drainage structures have been designed to 100‐year storm flow rate. See  Appendix D.          Appendix A                            PROJECT SITE PROJECT SITE PROJECT SITE         Appendix B                        6373RU100 Riverside County Rational Hydrology Program CIVILCADD/CIVILDESIGN Engineering Software,(c) 1989 ‐ 2005 Version 7.1 Rational Hydrology Study        Date: 10/28/21  File:6373RU100.out ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ JN6373 RATIONAL STUDY PRE‐DEVELOPED CONDITION 100YR STORM   ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐  *********   Hydrology Study Control Information **********  English (in‐lb) Units used in input data file ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ Program License Serial Number 5016 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ Rational Method Hydrology Program based on Riverside County Flood Control & Water Conservation District 1978 hydrology manual Storm event (year) =  100.00 Antecedent Moisture Condition = 3 Standard intensity‐duration curves data (Plate D‐4.1) For the [ Murrieta,Tmc,Rnch CaNorco ] area used. 10 year storm 10 minute intensity =  2.360(In/Hr) 10 year storm 60 minute intensity =  0.880(In/Hr) 100 year storm 10 minute intensity =  3.480(In/Hr) 100 year storm 60 minute intensity =  1.300(In/Hr) Storm event year = 100.0 Calculated rainfall intensity data: 1 hour intensity =  1.300(In/Hr) Slope of intensity duration curve = 0.5500 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station        1.000 to Point/Station        2.000 **** INITIAL AREA EVALUATION **** ______________________________________________________________________ Initial area flow distance =   241.000(Ft.) Top (of initial area) elevation =  1062.180(Ft.) Bottom (of initial area) elevation =  1059.140(Ft.) Difference in elevation =     3.040(Ft.) Slope =    0.01261  s(percent)=       1.26 TC = k(0.300)*[(length^3)/(elevation change)]^0.2 Initial area time of concentration =    6.453 min. Rainfall intensity =      4.432(In/Hr) for a   100.0 year storm COMMERCIAL subarea type                      Runoff Coefficient = 0.892 Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 1.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 3)  =  74.80 Pervious area fraction =  0.100; Impervious fraction =  0.900 Initial subarea runoff =      4.268(CFS) Total initial stream area =        1.080(Ac.) Pervious area fraction = 0.100 Page 1 6373RU100 End of computations, total study area =            1.08 (Ac.) The following figures may be used for a unit hydrograph study of the same area. Area averaged pervious area fraction(Ap) = 0.100 Area averaged RI index number =  56.0 Page 2           Appendix C  6373RD100 Riverside County Rational Hydrology Program CIVILCADD/CIVILDESIGN Engineering Software,(c) 1989 ‐ 2005 Version 7.1 Rational Hydrology Study        Date: 10/28/21  File:6373RD100.out ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ JN6373 RATIONAL STUDY POST‐DEVELOPED CONDITION 100YR STORM                                                                               ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐  *********   Hydrology Study Control Information **********  English (in‐lb) Units used in input data file ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ Program License Serial Number 5016 ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ Rational Method Hydrology Program based on Riverside County Flood Control & Water Conservation District 1978 hydrology manual Storm event (year) =  100.00 Antecedent Moisture Condition = 3 Standard intensity‐duration curves data (Plate D‐4.1) For the [ Murrieta,Tmc,Rnch CaNorco ] area used. 10 year storm 10 minute intensity =  2.360(In/Hr) 10 year storm 60 minute intensity =  0.880(In/Hr) 100 year storm 10 minute intensity =  3.480(In/Hr) 100 year storm 60 minute intensity =  1.300(In/Hr) Storm event year = 100.0 Calculated rainfall intensity data: 1 hour intensity =  1.300(In/Hr) Slope of intensity duration curve = 0.5500 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station        1.000 to Point/Station        2.000 **** INITIAL AREA EVALUATION **** ______________________________________________________________________ Initial area flow distance =   395.000(Ft.) Top (of initial area) elevation =  1061.600(Ft.) Bottom (of initial area) elevation =  1059.800(Ft.) Difference in elevation =     1.800(Ft.) Slope =    0.00456  s(percent)=       0.46 TC = k(0.300)*[(length^3)/(elevation change)]^0.2 Initial area time of concentration =    9.639 min. Rainfall intensity =      3.554(In/Hr) for a   100.0 year storm COMMERCIAL subarea type                      Runoff Coefficient = 0.890 Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 1.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 3)  =  74.80 Pervious area fraction =  0.100; Impervious fraction =  0.900 Initial subarea runoff =      3.226(CFS) Total initial stream area =        1.020(Ac.) Pervious area fraction = 0.100 Page 1 6373RD100 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station        2.000 to Point/Station        3.000 **** PIPEFLOW TRAVEL TIME (User specified size) **** ______________________________________________________________________ Upstream point/station elevation =  1055.300(Ft.) Downstream point/station elevation =  1055.150(Ft.) Pipe length  =    31.00(Ft.)   Manning's N = 0.012 No. of pipes = 1  Required pipe flow  =     3.226(CFS) Given pipe size =     18.00(In.) Calculated individual pipe flow  =     3.226(CFS) Normal flow depth in pipe =    8.00(In.) Flow top width inside pipe =   17.89(In.) Critical Depth =    8.20(In.) Pipe flow velocity =      4.25(Ft/s) Travel time through pipe =    0.12 min. Time of concentration (TC) =     9.76 min. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station        1.000 to Point/Station        3.000 **** CONFLUENCE OF MAIN STREAMS **** ______________________________________________________________________ The following data inside Main Stream is listed: In Main Stream number: 1 Stream flow area =      1.020(Ac.) Runoff from this stream =      3.226(CFS) Time of concentration =    9.76 min. Rainfall intensity =     3.530(In/Hr) Program is now starting with Main Stream No. 2 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station       21.000 to Point/Station        3.000 **** INITIAL AREA EVALUATION **** ______________________________________________________________________ Initial area flow distance =   306.000(Ft.) Top (of initial area) elevation =  1056.680(Ft.) Bottom (of initial area) elevation =  1055.150(Ft.) Difference in elevation =     1.530(Ft.) Slope =    0.00500  s(percent)=       0.50 TC = k(0.300)*[(length^3)/(elevation change)]^0.2 Initial area time of concentration =    8.543 min. Rainfall intensity =      3.798(In/Hr) for a   100.0 year storm COMMERCIAL subarea type                      Runoff Coefficient = 0.890 Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 1.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 3)  =  74.80 Pervious area fraction =  0.100; Impervious fraction =  0.900 Initial subarea runoff =      0.203(CFS) Total initial stream area =        0.060(Ac.) Pervious area fraction = 0.100 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station       21.000 to Point/Station        3.000 **** CONFLUENCE OF MAIN STREAMS **** ______________________________________________________________________ The following data inside Main Stream is listed: In Main Stream number: 2 Stream flow area =      0.060(Ac.) Runoff from this stream =      0.203(CFS) Page 2 6373RD100 Time of concentration =    8.54 min. Rainfall intensity =     3.798(In/Hr) Summary of stream data: Stream   Flow rate      TC            Rainfall Intensity  No.       (CFS)       (min)                 (In/Hr) 1        3.226      9.76          3.530 2        0.203      8.54          3.798 Largest stream flow has longer time of concentration Qp =      3.226 + sum of   Qb         Ia/Ib    0.203 *    0.929 =      0.189 Qp =      3.415 Total of 2 main streams to confluence: Flow rates before confluence point:        3.226       0.203 Area of streams before confluence:         1.020        0.060 Results of confluence: Total flow rate =      3.415(CFS) Time of concentration =     9.760 min. Effective stream area after confluence  =      1.080(Ac.) End of computations, total study area =            1.08 (Ac.) The following figures may be used for a unit hydrograph study of the same area. Area averaged pervious area fraction(Ap) = 0.100 Area averaged RI index number =  56.0 Page 3           Appendix D