Loading...
HomeMy WebLinkAboutButterfield Stage Road @ Murrieta Hot Springs Road (Page 4 Duplicate)CONDUCTOR SCHEDULE Awe CIRCUIT AA4 12 COND. SIGNAL CABLE (15 1 - - - - - - 2 05 06+OLB 06P 3 02,04,05,06 1 1 1 1 — — 1 4 02 04,OLA,04P — 1 1 1 — — 1 5 06 OLB 06P — — — 1 — — 1 ON OLA 04P — 1 TOTAL 1 2 1 2 3 1 1 1 5 3 COND. SIGNAL CABLE 1 06PP8 — — I — — — 1 1 2 — W 04PP8 — 1 1 1 — — 1 5 04PP8 6 06PP6 1 TOTAL — 1 1 2 — 1 4 12 IISNS 2 2 2 2 — #10 SIGNAL COMMON 1 1 1 1 1 1 2 -WMI-NAIRE 2 2 2 2 — 2 — TOIAL 3 3 3 3 1 3 2 DIET. LOOP CABLE TYPE B 02 DETECTORS 4 4 4 04 DETECTORS — — — — — — 5 05 DETECTORS — — 2 2 — — 2 06 DETECTORS — — — — 4 4 4 TOTAL DLC — — 6 6 4 4 15 EVP CABLE 1 2 2 3 3 COAXIAL CABLE 1 2 2 3 — — 3 CONDUIT SIZE 3" 3" 3" 3" 3" 3" —3 —2 of SIC DETECTOR PLACEMENT DETAIL LIMIT LINE NOTE: ALL DETECTORS TO BE CENTERED OR X—WALK IN LANE, UNLESS OTHERWISE NOTED THRU TRAFFIC LANE (TYP.) LEFT TURN LANE (TYP.) 2' 6'01 10' 16'01 10' 16'0 110' 16'0 DETAIL "A" OPTICAL PRE-EMPTION DETECTOR MAST ARM MOUNTING CLAMP (ASTRO MINI BRAC MOUNT 0 OR APPROVED EQUAL) 0 ........ .. ... .. . . ... LOCATE EVPE DETECTOR ON LEVEL ART OF MASTARM MAST ARM EMERGENCY VEHICLE PRE—EMPTION DETECTOR TRAFFIC SIGNAL MAST ARM MOUNTING DETAIL CONSTRUCTION NOTES (THIS SHEET M1 CONTRACTOR SHALL CONSTRUCT TYPE 332 CABINET FOUNDATION AND SHALL FURNISH AND INSTALL TYPE 2070 CONTROLLER ASSEMBLY IN A TYPE 332 CABINET. THE CONTROLLER ASSEMBLY SHALL BE EQUIPPED WITH BITRAN SYSTEMS 233 PROGRAM. THE CONTROLLER ASSEMBLY SHALL BE HOUSED IN A TYPE 332 CABINET WIRED FOR 8 PHASE OPERATION, AND INCLUDE FUNCTIONS INDICATED ON THE PLANS. THE CABINET SHALL INCLUDE CABINET DRAWER ASSEMBLY, AND CABINET LIGHT ASSEMBLY. THE CABINET'S POLICE PANEL SHALL BE EQUIPPED WITH A CONNECTION FOR A TRAFFIC SIGNAL CONTROLLER MANUAL OVERRIDE SWITCH. ALL EQUIPMENT SHALL BE ON THE CURRENT STATE OF CALIFORNIA "QUALIFIED PRODUCTS LIST". GDI LOAD SWITCHES WILL NOT BE ACCEPTED. fl FURNISH AND INSTALL A DUAL —METERED TYPE III—CF SERVICE EQUIPMENT ENCLOSURE WITH THE FOLLOWING CIRCUIT BREAKERS: 120/240V — 100A MAIN 120V — 50A METERED SIGNALS 240V — 40A UNMETERED LIGHTING 120V -- 15A METERED IISNS DUAL TYPE V -- P.E.C. 3� FURNISH AND INSTALL EMERGENCY VEHICLE PRE—EMPTION EQUIPMENT AND 4—CHANNEL DISCRIMINATION EQUIPMENT REQUIRED IN THE CONTROLLER CABINET. EQUIPMENT SHALL BE 3M 700 SERIES OR TOMAR 2140 SERIES ONLY. EVPE OPTICAL DETECTOR SHALL BE MOUNTED ON SIGNAL MAST ARM BY CLAMPING METHOD. EXACT LOCATION OF DETECTOR SHALL BE DETERMINED IN THE FIELD BY THE ENGINEER. MOUNT ON MAST ARM AS SHOWN ON DETAIL "A". ® FURNISH AND INSTALL 2" CONDUIT WITH NO. 5 PULL BOXES AT 200' SPACING SPACING (MAX.) TO STA. 123+00, ±4070'. FURNISH AND INSTALL 12PR#19 SIGNAL INTERCONNECT CABLE (SIC) TO PULL BOX AT STA. 123+00 AND COIL 50' OF SIC IN PULL BOX. INSTALL NO. 6 PULL BOX AT APPROXIMATELY STA. 154+15(ADJACENT TO FUTURE SIGNAL CONTROLLER CABINET AT MURRIETA HOT SPRINGS ROAD AT RORIPAUGH VALLEY ROAD INTERSECTION) AND COIL 50' OF S.I.C. IN PULL BOX. 0 FURNISH AND INSTALL TYPE "V" PEC UNIT IN SERVICE CABINET. ® FURNISH AND INSTALL MAST ARM MOUNTED SIGN PER STANDARD PLAN ES-7N, DETAIL "U". [7 FURNISH AND INSTALL SIGNAL STANDARD MOUNTED SIGN PER STANDARD PLAN NO. RS4. ® FURNISH AND INSTALL 2" CONDUIT WITH CONDUCTORS AS SHOWN. ❑9 FURNISH AND INSTALL "DIMENSION" BATTERY BACK—UP SYSTEM IN CONTROLLER CABINET. FURNISH AND INSTALL BATTERY CABINET ON REAR OF CONTROLLER CABINET AND WIRE PER MANUFACTURER'S SPECIFICATIONS. BATTERY BACK—UP CABINET DIMENSIONS SHALL BE 27"H X 24"W X 8"D. 10 FURNISH AND INSTALL COAXIAL CABLE (FOR FUTURE VIDEO EQUIPMENT) IN SIGNAL STANDARD AND TERMINATE IN LUMINAIRE MAST ARM. PLANS PREPARED SY6 VAN DELL AND ASSOCIATES, INC. S RtMORS LW KAmm 17e01 CARTWRIGHT ROM ItVW CA 92614 ice•) 474-1400 CONSTRUCTION RECORD CONTRACTOR INSPECTOR DATE COMPLETED DATE I BY MURRIETA HOT =rl 416L 4 2"C, 2 DLC. mol ~N V_ 0 417U0 004 .. ------------- -WALK 2#10 LUMINAIRES�j� SPRINGS DATE IACC'DI BENCHMARK 2"C. 2 DLC. PULLROFOR FUTl1REPS.I.C. �\ ' , 22. if,Z 1 �1 12 II II I I 14' 4 � 2� I I O � II II II DETAIL D I I 6J3U I I II I 0 F=1e' 5 . 02 02 P ¢5 l05 R366'� E �29 05 3 R73-8 - I 1 6 I W' DETAIL 04173 1 x RIL 418U 0 A " l4+AOLArD3 06 - ETAIL 4 6+OLB A Q S Rr* 5 2 7 1 4 9 ILI �No. TR001647 * Exp.9/30/06 lR,4FT tIC CAL 3#6 (SIGNAL)u � rC, �� nl 11 I 1 ROAD +' a24/7/05 20 10 0 20 40 06 OEM 7' M UNT 10 STA 273+92.73 O R96, 02 � R96A 11 04 213U I 213L / V III 51U 5J1L 12' 12' 2' 4' 0' 12' 12' 12' B► r I 1 s I I STA 164+19.51 MURRIETA HOT SPRINGS ROAD STA. 273+23.54 BUTTERFIELD STAGE ROAD R/W 1 io ETA 272+��•55 O 12" 12" 12" 12" PHASE DIAGRAM NOT USED NOT USED OLB /�1 � 01 02 03 04 OL�W NOT USED NOT USED 05 06 07 �68 06PO6 OLB W OL� 05 02 04 02 SEQUENCE WITH CALLS ON ALL PHASES DETECTION SPEED: MURRIETA HOT SPRINGS ROAD = 55 MPH BUTTERFIELD STAGE ROAD = 55 MPH RED (LED) YELLOW (LED) GREEN (LED) GREEN (LED) DETAIL "C" I 3 QUADRANT DETAIL PEDESTRIAN PUSH BUTTON LOCATION (TOP VIEW) 2'C, 2 DLC, S.I.C. 12" 12" 12" 12" 12" 0 0 0 RED (LED) YELLOW (LED) GREEN (LED) YELLOW (LED) GREEN (LED) 04+OLA 06+OLB DETAIL "D" DETAIL "B" POLE LOCATION E.C.R. EXACT LOCATION BY ENGINEER IN THE FIELD m SIGNAL STANDARD NO SCALE PLACEMENT DETAIL 0 LIJ ac • POLE SCHEDULE m POLE DATA SIGNAL H.P. SOD VAP SIGNAL MOUNTING PED. PUSH BUTTON * POLE LOCATION IISNS (TYPE A) NO. TYPE HT. M.A. M.A. WATTS VEH. M.A. PIED. PHASE POLE QUAD. A B MESSAGE (DBL FACE) 1 15 30 - 15 250 - -~ - 6 2 15' 3' ~- 2 1A 10 _ — — TV-2—T — SP-1—T — — 12' 3' -- i (3) 29-5--129 30' 50' 15' 250 _ _ 3—MAS — — — SEE PLAN 3' Murrieta Hot Springs 0- < 4 26-4-129 30' 45' 15'♦ 250 SV-2—T MAS SP-1—T 4 3 SEE PLAN 3' Butterfield Stage ■ ci 5 24--4--129 30' 35' 15' 250 SV-1—T 2—MAS SP-1—T 4 1 10' 3' Murrieta Hot Springs aaa 6 1A 10' - - -- TV-1-T - SP-1-T 6 2 12' 3' - 5 • POTHOLE MAST ARM POLE FOUNDATIONS PRIOR TO ORDERING POLES AND MAST ARMS. a SINGLE FACED 2"C, SIC TO ♦ LUMINAIRE MAST ARM MOUNTED PERPENDICULAR TO ROADWAY o CONTROLLER CABINET W 3 AT N. LOOP ROAD IMPORTANT NOTICE c� X SEE SHEET 3. SECTION 4216-2417 OF THE GOVERNMENT CODE REQUIRES A DIG ALERT IDENTIFICATION SCALE IN FEET 1 inch = 20 it. SCALE o pR )FESSjp�w R. HORIZONTAL �y� W M 1 "=20' No. 024725 Exp.12/31 /05 VERTICAL a � N/A F CP1. NUMBER BE ISSUEDBEFOREA'PERMIT TO , EXCAVATE WILL BE VALID. FOR YOUR DIG 212U 212U 212L ALERT ID NUMBER CALL UNDERGROUND SERVICE ALERT TOLL FREE 1-800-422-4133 18�57' 8TWO WORKING DAYS BEFORE YOU DIG. 1 1' DESIGNED BY DRAWN BY CHECKED BY 0 VU- a� -- a UNDERGROUND STRUCTURES a ALL UNDERGROUND UTILITIES OR STRUCTURES REPORTED BY THE OWNER OR OTHERS AND THOSE SHOWN ON THE �I RECORDS EXAMINED ARE INDICATED WITH THEIR APPROXIMATE LOCATION AND EXTENT, THE OWNER BY p ACCEPTING THESE PLANS OR PROCEEDING WITH IMPROVEMENTS PURSUANT THERETO AGREES TO ASSUME LIABILITY AND TO HOLD UNDERSIGNED HARMLESS FOR ANY DAMAGES RESULTING FROM THE EXISTENCE OF 00 UNGERGROUND UTILITIES OR STRUCTURES NOT REPORTED TO THE UNDERSIGNED: NOT INDICATED ON THE PUBLIC RECORDS EXAMINED: THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE C) UTILITIES OR STRUCTURES SHOWN AND ANY OTHER UTILITIES OR STRUCTURES FOUND AT THE SITE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES OR STRUCTURES CONCERNED BEFORE STARTING WORK. ��- * SEE DETAIL "B" KRR/KK KK KRR RECOMMENDED BY • �• � 8 ��-jo CITY OF TEMECULA DEPARTMENT OF PUBLIC WORKS PLANS PREPARED UNDER THE SUPERVISION OF ACCEPTED BY: � �A�: TRAFFIC SIGNAL PLAN DATE: Z�1 7/a � RONALD J. PARKS, w MURRIETA HOT SPRINGS ROAD AT DEPUTY DIRECTOR OF PUBLIC WORKS DO ALD R. GORDON R.C.E. N0. 024725 EXPIRES: 12-31-05 R.C.E. N0. 19744 XP�RES: 9�3o�2oa5 � ,999 BUTTERFIELD STAGE ROAD LD04--23000 b Drawing No. z o 0 T_ O TS-3 0 w SHEET 4 OF 4 CL ;�