Loading...
HomeMy WebLinkAboutTract Map 3883 Lot 69 Prelim Geotechnical Investigation I I I I I I I I I I I I I I I I I I I PREUMINARY GEOTECHNICAL INVESTIGATION Single - Lot, Residential Development Lot 69, Tract 3883, La Colima Road A.P.N.919-05104)12 Temecula, California December 20, 2001 PROJECT NO. 21395-01 PREPARED FOR: Rhonda & William Thomas 3628 Lake Garden Drive Fallbrook, California 92028 Earth Technics P.O. Box 891989, Temecula, California 92589 (909) 699-5451 FAX (909) 767-1193 I I I I I I I I I I I I I I I I I I I December 20, 2001 Project No. 21395-01 1.0 INTRODUCTION At your request, we have performed a Preliminary Geotechnical Investigation for the above referenced site. The purpose of our investigation was to evaluate the underlying soil conditions with respect to the proposed development and to assess the geotechnical and engineering constraints that might exist considering this development. The 40-Scale Topographic Plan prepared by Earth Technics, based on field measurements, was used to direct our field work. Plate 1 presents our Geotechnical data obtained during our field investigation. At the time of our investigation, the property corners had been surveyed and staked. ACCOMPANYING MAPS. ILLUSTRATIONS AND APPENDICES Index Map - (2000-scale) - Page 2 Geotechnical Map - (40-scale) - Plate 1 Regional Fault Map - (1" = 20 miles) - Plate 2 Appendix A - Geotechnical Trench Logs Appendix B - Summary of Laboratory Test Results Appendix C - General Earthwork and Grading specifications Appendix D - Slope Stability Appendix E - References \ I I I I I I I I I I I I I I I I I I I INDEX. MAP N o 2000 4000 SCALE INDEX MAP feet 0 F 1.25+j-ACRES, APN 919-051-012 LOT 69, TRACT 3883, MEADOWVIEW ESTATES TEMECULA, RIVERSIDE COUNTY, CALIFORNIA 2 SOURCE: U.S.G.S. 71;, MIN. QUAD. MURRIETA 1953 (PR 1979) 2 I I I I I I I I I I I I I I I I I I I 21395-01 Page 3 2.0 SITE LOCATION/CONDITIONS The irregularly-shaped 1.25 +/- acre "flag lot" is located on La Colima Road approximately 475 feet northeast of N. General Kearney Road, both improved paved roads, in the Temecula area of Riverside County. The property is bounded by La Colima Road at the narrow access on the west, with existing homes to the north and west, and vacant land in all remaining directions. Topographically, the parcel is very gentle descending to the east-southeast at less than 12 percent. Total relief over the lot is 16+/- feet, but less than 8 feet in the area proposed for pad development. No bedrock is exposed at the site. A large swale crosses the southeast corner of the site, and displayed evidence of considerable previous running water. At time of our testing the site had been disced for weed control. Large eucalyptus trees are located on the eastern property boundary. The topographic and geographic relationsips of the lot to adjacent areas is shown on the Index Map (Page 2). 3.0 PROPOSED DEVELOPMENT Based on the initial 20-scale Precise Grading Plan, being prepared by Earth Technics, the site will be developed with a cut and fill pad and driveway access with a northern retaining wall. The pad will be constructed with maximum cuts and fills on the order of 5 and 8 feet respectfully at finished slope inclinations of 2:1 (horizontal'to vertical) or flatter. The pad area for the proposed single-family residence will be constructed in transition from cut on the northwest to fill on the southeast. An access driveway to provide vehicular access to the residence will incorporate daylight cuts of 4-6 feet and a retaining wall on the north to a maximum height of 4 feet. The generalized house footprint is shown on Plate 1. On-site sewage disposal will be utilized in the natural areas unaffected by the current grading and is shown on Plate 1. 4.0 SCOPE OF SERVICES The scope of our investigation included the following: 1. A review of available data pertinent to the site. .3 I I I I I I I I I I I I I I I I I I I 21395-01 Page 4 2. Subsurface exploration of the site utilizing 3 exploratory backhoe trenches to depths as great as 14.7 feet. The trenches were logged, and these logs appear in Appendix A of this report. Several trenches were tested for in-place density utilizing the Sand Cone Method (ASTM 01556-64). Representative bulk samples were obtained for testing. 3. Laboratory testing of representative earth materials to develop soil engineering parameters for the proposed development. 4. Preparation of this report presenting our findings, conclusions and recommendations concerning site development based upon an engineering analysis of the geotechnical properties of the subsoils as determined by field and laboratory evaluation. 5.0 LABORATORY TESTING The following tests were performed for this project in our laboratory in accordance with the American Society for Testing and Materials, the State of California Standard Specifications or contemporary practices of the soil engineering profession. 5.1 Maximum Densitv - optimum Moisture Determinations This test determines the density that a soil can be compacted to at various contents. For each soil moisture, there is a maximum dry density obtained and the associated optimum moisture content. The results are used to evaluate the natural compaction, control of the grading process and as an aid in developing the soil bearing capacity. This is based on ASTM Standard D1557-78 (five layer method) . 5.2 In-Situ Moisture and Densitv These tests consisted of performing Sand Cone Density tests (ASTM DI556-64) in the trenches to determine in-place moisture and density. The results are used to analyze the consistency of the subsoils and aid in determining the necessary grading to prepare the pad area. 5.3 Sieve Analvsis This test determines the material grading of the individual particle sizes and is used in generating an engineering classification. "\ I I I I I I I I I I I I I I I I I I I 21395-01 Page 5 5.4 Sand Eouivalent Testino This is a test for the rapid determination of the relative portions of fine silt and clay materials within the soil samples, and is used for a relative comparison of soils in the determination of the adequate paving sections for driveways, etc. 5.5 Expansion Testino The expansion index of the soils are determined by the V.B.C. Method 29-2 and is used to design foundations for anticipated expansion forces. 5.6 Direct Shear A direct shear strength test was performed on a representative sample of the on-site soils remolded to 90% relative compaction. To simulate possible adverse field conditions, the sample was saturated prior to shearing. A saturating device was used which permitted the samples to absorb moisture while preventing volume change. This test is used to determine soil strengths for slope stability evaluations and for foundation bearing capacity. 5.7 Soluble Sulfate A representative surface sample was tested to determine soluble sulfate content. The test results are used to recommended the type and strength of concrete to be used in construction. 6.0 SUBSURFACE CONDITIONS The area of the proposed pad is underlain by colluvial soils with variable thickness from 2-4 feet. The colluvium thickens to the south at 3.5 feet in the area of the proposed fill. In-place densities for the colluvium were low with densities of 106.3 pcf (83.2% relative compaction) to 111.3 pcf (87.1% relative compaction) and moistures of 4-8 percent at 2-3.5 feet below the existing ground surface. The underlying Pauba Formation bedrock was dense to very dense with in-place densities of 116.2 pcf (90.9% relative compaction) to 117.8 pcf (92.2% relative compaction) at 4-5.5 feet and moistures of 6-7 percent. 7.0 GROUND WATER No ground water seepage was encountered on the site to a depth of 14.7 feet. Historic high ground water is expected to be 60-65 feet at the lowest elevations of the lot based on historic ground water in nearby wells 1000 feet to the southwest T7S, R3W 35-Al (DWR, 1971). s ... I I I I I I I I I I I I I I I I I I I 21395-01 Page 6 8.0 FLOODING According to the Federal Emergency Management Agency and the county of Riverside, the pad site is not located within the boundaries of a 100-year flood plain. The stream crossing the southeast corner of the property presents a flooding hazard in a narrow channel 20-25 feet wide, but 4-6 feet below the pad area. No potential for flooding exists on the proposed improved and elevated pad. 9.0 GEOLOGY The entire proposed building pad area is underlain at depth sedimentary bedrock identified as the pauba Formation (Mann, 1955; Kennedy, 1977). The poorly-developed bedding was oriented N80-85E and dipping 5-7 degrees NE. No evidence of slope instability exists at the site or in the adjoining cut slopes along La Colima Road. The site is not included in any state or County fault hazard zone for active faulting. 10.0 SEISMIC SETTING/GROUND MOTION PARAMETERS The regional seismic setting is shown on Plate 2. The nearest active faults to the site include the Wildomar Fault of the Elsinore Fault Zone which is located approximately 5.1 miles to the southwest. The Casa Lorna branch of the San Jacinto Fault is located 22 miles to the northeast. The Elsinore Fault zone because of its proximity and seismic potential to the site is the design fault when evaluating the site seismic parameters. 11.0 HISTORIC SEISMICITY During the last 100 years in the San Bernardino/Riverside area, the greatest number of moderate to large earthquakes (greater than 6.0 M) have occurred along the San Jacinto Fault (Hileman, Allen and Nordquist, 1974; Peterson, et all, 1996). The most significant earthquake epicenter of magnitude 6.0M on the Elsinore Fault occured 12+ miles to the northwest in 1910 in Lake Elsinore. Several earthquakes of magnitude 6.8M and 7.0M have occurred on the casa Loma and San Jacinto faults approximately 20-22 miles northeast. ~ ... I I I I I I I I I I I I I I I I I I I 21395-01 Page 7 12.0 SEISMIC EXPOSURE Although no precise method has been developed to evaluate the seismic potential of a specific fault, the available information on historic activity may be projected to estimate the future activity of the fault. This is usually done by plotting the historic activity in terms on number of events in a given time interval versus magnitude of the event. Based on such plots, recurrence intervals for earthquakes of given magnitudes may be estimated. A probabilistic evaluation of potential seismicity for the site utilizing FRISKSP (Blake 1998) indicates a 10% probability of exceedance of 0.62g in 50 years assuming all seismic sources. We have utilized strain rates of 5.0 rom/year for the Elsinore Fault suggested by Peterson, et aI, (1996) to estimate the maximum moment earthquake. We estimate the maximum moment magnitude or "design earthquake" for the Elsinore Fault to be 7.5 magnitude with a 10% possibility of exceedance in 50 years. This is in agreement with the probabilistic model by Blake, (1998). 12.1 1997 U.B.C. Seismic Parameters: The following UBC seismic parameters should be incorporated into seismic design: Nearest Active Seismic Source (Type B Fault) - 8.2 km Soil Type* - SD Near Source Factor N. - 1.0 Near Source Factor Nv - 1.1 * Soil type may be Sc but requires additional field work to verify. 13.0 GROUND MOTION CHARACTERISTICS The ground motion characteristics which could affect, the site during the postulated maximum moment magnitude of 7.5 on the Elsinore Fault were estimated. Available information in the literature about maximum peak bedrock acceleration and its attenuation with distance (Joyner and Borzognia, 1994), the effects of site-soil conditions on surface ground motion parameters (Seed & Idress, 1982), and site response criteria (Hays, 1980) were utilized. The predominant period of bedrock acceleration is expected to be 0.30 seconds with 24 seconds of strong ground shaking (Bolt, 1973) . 1 - I I I I I I I I I I I I I I I I I I I 21395-01 Page 8 14.0 SECONDARY SEISMIC HAZARDS The dense well-cemented nature of the underlying sedimentary bedrock in the area of the existing pad at depths as shallow as 4.0 feet, and the historic depth to ground water over 60 feet precludes such secondary seismic hazards as liquefaction. lateral spreading or settlement of the ground the house is being placed upon. No rockfall hazard exists at the building site. The potential for seismically-triggered landslides is discussed in detail under the slope stability section. 15.0 CONCLUSIONS AND RECOMMENDATIONS 15.1 Foundation Desiqn A strip and spread footing foundation system should provide an adequate foundation for one and two-story buildings in this site. All exterior footings should be founded a minimum of 18 inches below adjacent finished grade for two-story buildings, and 12 inches for one-story buildings. Interior footings may be founded a minimum of 12 inches below finished grade. When the footings are founded in properly compacted fill or dense bedrock, an allowable bearing capacity of 1500 psf for 12 inch wide footings is acceptable for dead plus live load. This value may be increased by one-third for short term wind and seismic loading conditions. When foundations are placed in natural soils, no cobbles over 6 inches should be left within the base of the foundation. A typical foundation design is included in Appendix C. Two No. 4 bars, 1 top and 1 bottom, is recommended as a minimum design. 15.2 Settlement Our subsurface investigation revealed that the alluvial soils on the south are loose and soft. Upon replacement with compacted fill settlement potential will be reduced. Footings should experience less than I-inch total settlement with less than 1/2 inch differential settlements between adjacent footings of similar sizes and loads. This settlement is based upon grading of up to 30 feet of fill over a distance of 60 feet horizontally. If thicker fills are proposed, settlement could be greater and should be evaluated prior to placement. 15.3 Concrete Slabs-On-Grade Sufficient fine-grained materials exists within near surface earth materials to possible create moisture problems. Therefore, we recommend that a moisture barrier be placed under any concrete b ~ ... I I I I I I I I I I I I I I I I I I I 21395-01 Page 9 slabs that might receive a moisture-sensitive floor covering. This moisture barrier should consist of a 10-mil polyethylene vapor barrier sandwiched between a 1-inch layer of sand, top and bottom, to prevent puncture of the barrier and enhance curing of the concrete. Reinforcement of the slabs with 6x6-6/6 welded wire mesh centered in the 4 inch slab is recommended. The subgrade below the slab should be. moisture conditioned and properly compacted prior to placement of concrete. 15.4 Expansive Soils - Soluble Sulfate Expansion testing of near-surface silty sand soils (T-1 ; 0-3 feet) possible at finished grades indicate that the soils in the pad area are very low expansion. No special design provisions are necessary for the foundation or concrete flatwork to resist expansion forces as shown on the Foundation and Slab Recommendations for Expansive Soils in Appendix C. This is in accordance with the U.B.C. Table 18-B-1. The soluble sulfate content was 62 ppm allowing normal Type II concrete with 2500 psi strength. 15.5 Earthwork Shrinkaqe and Subsidence Shrinkage of the colluvium will occur during grading, estimated as 8-10 percent when recompacted to compacted fill standards. The sedimentary bedrock is expected to bulk 3-5% when placed as compacted fill. 15.6 Retaininq Wall Desiqn Retaining walls should be designed using the following parameters: o o o Active pressure Active pressure Active pressure (level backfill) (2:1 backfill) (1 1/2:1 backfill) 42 lb/ft /ft 52 lb/ft /ft 58 lb/ft/ft For purpose of lateral resistance, a value of 0.35 may be used for frictional resistance. A value of 275 lb/ft /ft may be used for passive resistance for footings placed into properly compacted fill. Frictional and passive resistance may be combined, provided the later is reduced by one-third. Special loads for dead plus actual loads should be considered in the driveway/parking area that is retained. ~ . I I I I I I I I I I I I I I I I I I I 21395-01 Page 10 15.7 Lateral Loads Lateral loads in the near-surface soils are: Active At Rest Passive - 42 pounds per square foot of soil depth (psf/ft) - 58 psf/ft - 275 psf/ft (for wood shoring) 350 psf/ft (for concrete footings) Active means movement of the structure away from the soil; at rest means the structure does not move relative to the soil (Such as a loading dock); and Passive means the structure moves into the soil. The coefficient of friction between the bottom of the footings and the native soil may be taken as 0.35. 15.8 Trench Stabi1itv The near-surface soil to a depth of 5 feet should stand vertically when excavated, however, trenches in excess of 5 feet in depth should have the sides laid back at 1:1 in accordance with OSHA requirements. 15.9 Slope Stabi1itv The proposed grading indicates the maximum slope height is 8 feet at finished face inclinations of 2:1 or flatter. The high strength values allow 2:1 (horizontal to vertical) cut and fill slopes up to 35 feet without gross or surficial instability. Selection of Shear Strenath Parameters The following shear strength parameter utilized for our slope stability analysis was determined by our laboratory test results as presented below: Material (Cut or Fill) Friction Angle (Dearee) Cohesion lb/ft2 Anticipated On-site Fill 28.0 340 We have utilized values of 28.0 degrees and 340 Ib/ft2 for bedrock cut slopes although it represents a conservative number, determined from a remolded saturated sample. Bedrock is expected to be 20% + stronger (Coduto, 1989). Even more critical to overall cut slope performance is the orientation of joints and fractures and bedding. All measured vague poorly-defined bedding was at a low angle into the slope. \0 . I I I I I I I I I I I I I I I I I I I 21395-01 Page 11 No evidence of slope instability exists on the site and adjoining areas. The bedrock and low angle into slope bedding orientation make all the natural slopes stable. Drainage and terracing should be in accordance with Uniform Building Code Appendix Chapter 33 requirements. At no time should water be diverted onto the slope face in an uncontrolled and erosive fashion. Rapid erosion and rutting of the fill slopes could occur, and they should be planted with drought resistant landscaping as soon as possible. 16.0 GENERAL SITE GRADING 16.1 C1earinq and Grubbinq Any heavy brush and grasses or remaining trees that exist at the time of grading should be stripped from any areas to receive fill and removed off-site or stockpiled in landscape areas. 16.2 Preparation of Buildinq Pad Areas The proposed grading will encounter colluvium that should be removed to a minimum of 2 feet to a maximum of 4 feet to firm sedimentany bedrock as determined during grading inspections. The cut/fill transition should be removed by overexcavation to 3 feet. 16.3 Preparation of Surface to Receive Compacted Fill All sufficiently dense (90 percent relative compaction) surfaces which are to receive compacted fill should be scarified to a depth of 6 inches, brought to near optimum moisture content and compacted to 90 percent relative compaction. other softer areas must be overexcavated to sufficiently dense material and recompacted. Anticipated overexcavation and colluvial removal would be 2.0-4.0 feet on the west. Actual depth of removal should be determined at the time of grading by testing. 16.4 Placement of Compacted Fill Compacted fill is defined as that material which will be replaced in the areas of removal due to root removal, the placement of footings and paving, and also wherever their grade is to be raised. All fill should be compacted to a minimum of 90 percent based upon the maximum density obtained in accordance with ASTM D 1557-78 procedure. The area to be filled will be prepared in accordance with the preceding section. Fills placed on natural slopes of 5:1 (horizontal to vertical) or steeper will require a key and benching as shown in Appendix C. II . I I I I I I I I I I I I I I I I I I I 21395-01 Page 12 16.5 Pre-Job Conference Prior to the commencement of grading, a pre-job conference should be held with representatives of the owner, developer, contractor, architect and/or engineer in attendance. The purpose of this meeting shall be to clarify any questions relating to the intent of the grading recommendations and. to verify that the project specifications comply with recommendations of this report. 16.6 Testinq and Inspection During grading, density testing should be performed by a representative of the soil engineer in order to determine the degree of compaction being obtained. Where testing indicates insufficient density, additional compactive effort shall be applied with the adjustment of moisture content where necessary, until 90 percent relative compaction is obtained. Inspection of critical grading control procedures such as keys, installation or need for subdrains, should be made by a qualified soils engineer. 16.7 Development Impact Provided the recommendations of this report are incorporated into the design and construction of the residential project, both the proposed development and off-site areas will be safe from geotechnical hazards. 17.0 GENERAL All grading should, at a minimum, follow the "Standard Grading and Earthwork Specifications" as outlined in Appendix C, unless otherwise modified in the text of this report. The recommendations of this report are based on the assumptions that all footings will be founded in dense, native, undisturbed soil or properly compacted fill soil. All footing excavations should be inspected prior to the placement of concrete in order to verify that footings are founded on satisfactory soils and are free of loose and disturbed materials and fill. All grading and fill placement should be performed under the testing and inspection of a representative of the soil engineer. The findings and recommendations of this report were prepared in accordance with contemporary engineering principles and practice. Our recommendations are based on an interpolation of soil conditions between trench locations. Should conditions be encountered during grading, that appear to be different that those indicated by this report, this office should be notified. 12. . I I I I I I I I I I I I I I I I I I I 21395-01 Pag'e 13 Respectfully Submitted, Larry J. Fast, R Registration Expir Services \3> ------------------- l1, >( ~ ~ -'\ e L-4 COLI!:!/! ::...,?..AP __ :;: o o " ~ ~'- "' (106' ... {v" IId6 1(06' ~ ~\ ~I~ + IT~~ 1 ~ ~ t !:\ ;) , -\ -l> , . \U> -c ", ", x ;0 -c n , o 0 , ;0 ;J;> ;to ~ ...; -I ~ 0 o ;0 "tI Z -< ,r- -I -I ~ ", ;0 z U> ", :r> -I ~ -l ::c - o z ,';v'. o I-' -c 0;0 o~ ... 3: ;to ", ;0 x-< -c ;to, Z'" (/l):> ~n o ::c Z , ,I-' ", 2l ;to", nu> ::c , I-' Z ", U> n U * * * * z r ;:t:oo +:a o m -0 I ;to -c OJ ""0 n r- m o :::I: 1-4 0 ;0 n;o -4 I :;x::. 0 1-4 I--t -i 0 o :z ~ 3: Z ", 0 U> Z ::c o 0 " :r::: ;:0 c: ~ ;to U> :;x::.. -i -i rrI OJ ::c ", U> ;0 o ...... 0 rr1 ;0 "T1.o -c "T1 c -i 0 00 ....... I--IOO:::O(f) ~-lV'l~< 0.0 0 U>"T1CI-'-1 -< ):> N .., Vl ::::c ::tJ 0 m -10"'0"", m n l;a 3: ^ "'T'1 G') ", ;to _ c - fT1 r ,.", ZVl-lr-m ~ W ...... ~ ~ ;oNU> G) o 0 l.Q ~ Z ;:0 r 0-. -0 - ........ 0 -I <::z ~ fT1 m V'l (""') :E ;to .0 )::0 ;:::0 C ---i -< ;to;to (J') " ;:0 :z .. fT1 fT1 7' ", , IT1 -I "T1 -I m no", . "T1 -I w 0 I "T\ "T1 o ;to o OJ -I U> o :E ;0 I-' -c <::> -I ", ~ o , :z ", ;to ;to n ;0 ::c ", ;to , , I-' Z ", , ~ I ~ ---~ )~ \ ~"" v" -- ,,~ ~/o < -;i -I h--- (/ot;) ~ "". "- '" ...... ~ ~ ~ \ D ~ I \1\ , ; t I f\l If\ I ---:;.-------....... ---=-~...:==--- ----- :< \ ~ \ '--'>-.. .l) \ /'--- \ /~T-C-- - D(~/--'~~ti t!ytD ~ ) - ----"'--- _t: __ \ --- -.......1......" y, ~',-- -1<- '- t ~ -- i t ----- " ------/1 ,~ -.. ,,' ~ , '" '" '"' C~ ? '0' I" "tI ~ -l m ~ ~ ... I I I I I ... ... ::1! o ,. r r m ,. o % C z m ~~ . ,'+ '< \ .. q,. <.. 7~ .. ~ ... CC..;:;: "~=~=~::= .. .... 1:1: E " :l::. aatii ~ =ilit~=.ooI,,= < Oat '< :D ~ ~;.il!! -1-;' ~. . ~ ~ ~ " n ~ w ~ ~ " W ~ ! . ;~ 5 ~ ~ ~~ - I . i So _ii ! . g ... 1-- ;; :;: ~ . i lei - ~ i ::1 - - ii . I"' ~ is ... ,1::- ! ! " . . ~ 51 - :2! z ~ ! i. i: 0 ~ ! ! =: c ~ o. ..- i= ~ - . ~.. m - " - - - . . . - - 1-= " . , ... I'~ >- - :'" "";;::a ~ . - - - - " i - F-' ~ - 'w " " ~ :H ;; " - - - " " i . - -I'. . - ::: "5 - - . , -I" _u_ ~~~s i;5~ J-". ..._:Ii !!~.I a"'!i -i- ...1.. i:;' IE".. ..=. ,'U =..= i!:'" ~::a.. ;;;:-i! =_,' 1._- .....- ~~.... .:... ..;;~s =.;:;.. :-=_. ....... -J!i ~;!.. 1.:1 ::-= =:"! -I~- ... =:1:: :!s !"'.eA ..... :;: ::i:: ~S~~ ;;: . ~~ ;::"'11 .;1 .tiS .~ , , ;:I:!_I = 5" .. . ..:== ... i--- E S.i" , i..... .:: -..-- _"'ll. ;: Itl:..: ::: li.is . iiii! _...1 ... IE;~= .. toO. ~'~... :....11 ili:.: .. ..1- i,;h =:!:"j ii::~: ~i-~= I' ~ -. -- ~ c- o ar z o I. ~ \ll \!) U1 I o - 051 I I c ~ ~ I ~,...- . . i' -- .0 I I I I I I I I ... ... " n ,. r r m ,. o % r Z m ... i2 ... m I: . ~ ! n ~ c ~ ~ i> ~ ~ . ~ " ~ ~ ~ .. ~ , " ~ ;: ~ " !' .. " ~ n . ~ .. .,,;,); n ~ ~ . . g ~ I-~ . . . i' .. ~; .~ ~n " ;; ~ 2 .. c ~ o . ... .. ~,il ,. r f- . 0 . .. .. . . ~ . jt ~ .. : : . ~ ~ ~ " " " . . . ! ! . ~ ~ ~ w . _ .. .. .. ~ .. " ~ .. " ~ ~ ~ ~ i ~ " " " He .... .. ~ ~ ~ . . o. · E ~i'= ~ . . n . !: . . . o ~ ~ ~ . . n . ~ . . c. .. ~. =. ~~ m o c ~I ii' ~ I 1. r ~ o % C z m C " m '" ... 0 - " t:) 1ft Z '" ... "II ... o " '" .. ~ ... z r o :!! z D Ii) '" o c z '" I I I W"TIII UNI o . ~ l= .. ~- ~. ~n .~ ~!: ..~ ~~ ll= ! ~ . . ~ ~ ~ - . " ~ . ~ )- . . i' a . ~ . .. . n . ~ sa ~ I ~- .!: -.;;~. ~~. '1J.~.:i ~I c"~: ... n- I.... S! =a ..-::;: :.. == ,.Ot M. ...' ..~ 0 ":u -i . l~'. =~ 2 '.1. ~E - ~~'r-'r ...& ..... -c r I'''.. I ."; . , ~,"'. ~...:.. . lCt';' ...., .':,' 1 .:.... . It":': ..... 'tt.." . . ~ , c:. ; .~ ,....'.........;. ~~ ......... 10)" . '. 210 . . 0" c . " . . . . ~. t !!C: .. :a:. S ~& :.e;; _ 0_ 0: .. ".. .. . .. ~ I .. rK a .. M. .. ~' ~. >>0 . zc: I ~ ;'l~,.~~!"f'I~:& t:J: :I: DO............ n =: i DO........ ~~ a -4 -. . -~ .. . .. ; .. :s iI: Z .... .. 0 -:II II n _ 0 " ~ " " n : II 0 " " ::l ~ I: :i . I I .......... 0...0 0, " r ~ m ro I I I I I I I I I I I I I I I I I I I APPENDIX A Ij:. ... I I . . . . . . '. . ,. . I I I . . I I GEOTECHNICAL TRENCH LOG Pro/eel Name THOMAS pro/eel Number 21395-01 Elevallonll 03+/ - Equlpmenl CASE 580 SUPER L BACKHOE Trench No. T-1 ~ c ! i .2 GEOTECHNICAL DESCRIPTION - . .c - I~ 'i , - - Q. Ii ;: . . ?;' ~. . ! ~ . 0.,. I Cl 'i . . U.L. SHERUNG .0 c ! . . Logged by 12/15/01 <; . ~ -. .c ii = o . = Dale a. E . '" W.L. SHERLI NG .! . ~ j - - ~ Sampled by ~ . ~ j . 0>' Cl .. 0 0 _ MD - 5.8 SM SOIL/COLLUVIUM - Bro~n 10 YR 5/3 silty sand w/trace'of or~ ~~ 106.; - (83.~ ) clay, Soft, porous, s'l. damp upper 12" then dry. - --:: EI K 117 .~ Grad. 'lower contact. I - c~ 7.8 S04 (92.l ) l- s- f-s - I- - ..' BEDROCK - ,Pauba Formation - Interbedded sequence of e.: - SM/ ~ silty and' clayey sands with mi nor fi Fie grave 1 to 1;,". ~ ~ - SC Occ.intervals 1-6" thick of s1. silty to almost clean '- med. - coarse gravelly sands. Dense to very dense, sl , 10- damo. /' I i 4: - - , - " T.D. 7.8 Feet '- .., No Water / Mottling - - - - 15- -1! - - - - - - GRAPHIC LOG trend - scale: 1"c - . Symbols - Test - B" Bulk SImple , , I , R - Ring Sample , , , , SC - SMd Cone I I IT r II I I I IT MD" I- - Mulmum Dofillly I- - G S - Grain Slz. I- - SE - Sand Equl......t I- - EI - expaMlon Index (90)- R.latlva Compaction '- - '- - '- - Ear h '- - I I I , . I , I I I I I : .echnics "To 0' - . Y-o-- ~...- - ~ ~ - 11 - I I GEOTECHNICAL TRENCH LOG PrOject . Project Name THOMAS N b 21395-01 um ar Elevation 1096+ /- E I t CASE 580 SUPER L BACKHOE Trench No. qu pmen ' T-2 I . . I . I . I I I . I . I I I - .I - i . "" I j.., i GEOTECHNICAL DESCRIPTION - - - g .. - t t I ~ =. ! Q ;; u.,. : . W.L. SHERLING 0: ; . ~ Logged br "" '0 ~ & -. Date 12/15/01 u . - ... I :> "" ! E - SlIIIIpled by W.L. SHERLING . t' 1- ~ ~ . .II ... Q 0 0 - ! SOIL/COLLUVIUM - Pale brown 10 YR 6/3 to 6/4 silty fine - - 11.~ 4;7 SM med. sand w/trace of clay & minor fine gravel. Damp, - sCJ 87. l soft porous. Grad. lower contact. - ~ 16., 6.2 -!i - (90.~ ) BEDROCK - Pauba Formation - Brownish yellow 10 YR 6/6 to ,- - SMSC 7/6 interbei:Jded s i lty andsl. silty sand w/mi nor fi ne " - - \ gravel. OCc. intervals of clayey sand 8-12" thick. / f- Dense to very dense, sl. damp. - f- 10- ~ - LD, 7.2 Feet f- - No Water / Mottling '- -, - I - '~ 15-: ~! -+ - .:. - - - GRAPHIC LOG trend- scale: 1", - i- . Test Symbols - -+ '- B - Bulk Sample - - R - Ring Sample I I I I 1 I I I SC - Sand Cone I I 1 I I I 1 I I 1 I I - - MD- Maximum Density - - GS - Grain Size - - SE - Sand Equivalent - - EI - Expanalon Index (90)- Relative Compaction -+ - f- - '- - Ear h - - I I I I I I I I I I I I ~ echnics I I I I I I , - 4 w---=-;.-' - - !:--" \& ~ - I I Project . Project GEOTECHNICAL TRENCH LOG Name THOMAS Number 21395-01 Elevation 1098+/- Equipment CASE 580 SUPER L BACKHOE Trench N T-3 o. . . I I I . . I . . I I I I I I - j - i GEOTECHNICAL - . ~ I L, i DESCRIPTION - - ! 1 !# . : 1: =. :: .. : . I W.L. SHERLING " ; .~ LoggacI br 12/15/01 - ~ .!l -. Date ~ 0 u . - f - ~' ! J! "" S~ad by W.L. SHERLING . ~ - - ~ ~ . . J .:I . .. 0 - SOIL/COLLUVIUM - Pale brown 10 YR 6/3 silty to sl. silty - - sand with'minor fine gravel to 3/8". Trace of clay at - - lower contact. Soft, porous, sl. damp to 12-15" then - almost drv. 5- -!i - BEDROCK - Pauba Formation - Light yellowish brown 10 YR ,... - 6/4 - 6/6 interbedded sequence of silty and clayey fine- - - medium sands with trace of gravel to 1;,". Occ. intervals - - -i 1-6" thick sl silty med.-coarse sand \~/5% gravel. - 10- B Sl. damp, dense. -4( U - GS L - - K - - T.D. 15.7 Feet f- 15- No Water / Mott1in9 1-1! - f- - I- - I- GRAPHIC LOG trend - scale: 1": I-- . Test Symbols l- I-- e - Bulk Somplo e- R - Ring Sample , , I , , , , S C - Sond Con. TTTT TTT I TTTI MD - Moxlmum Density - - - GS - Groin Size I- - SE - Sand Equivalent I- - EI - Expanllon Index e90)- Relative Compaction I- - I- - I- - Ear h "- - , , , , , , 0 I o , , , : ~echnics ,TT o I I I y-/ ~..-- \<\ ~ ~ - I I I I . . . . . . I . . . . . I I I APPENDIX B . 20 I I I I I I I I I I I I I I I I I I I MAXIMUM DENSITY - OPTIMUM MOISTURE DETERMINATION The maximum density was determined in accordance with ASTM standard DI557-78. The result by full laboratory curve is Sample Depth Maximum Optimum Location (Feet) Soil Description Drv Densitv Moisture T-l 0-3 (Soil Type A) Soil 127.8 11. 6 light brown silty sand with 5% gravel T-1 5-7 (Soil Type B) Pauba 126.5 11.9 silty sand with minor gravel trace of clay SUMMARY OF EXPANSION TESTING U.B.C. METHOD 29-2 Sample Location Oepth Expansion Index Expansion Potential T-l 0-3' 14 Very Low SAND EOUIVALENT TESTING Sample Location Depth Sand Equivalent T-1 0-3' 28 2.\ - I I I I I I I I I I I I I I I I I I I Project: Thomas Job Number: 21359-01 Date: Direct Shear Test Data " Ea~chnll ~c. 12/18/01 . 5 .. ./ V ./ V ~ / .... - Best-Fit Line ~ II.. d U) - !II Co i: . . !II !II CD ... ... CI) Cl c .;: III CD .c CI) . Actual Values o o Normal Pressure-Kips/SQ. FT. 5 Excavation Number: T-l Depth: 0-3' Saturated Test </J =,;~8.00 Degrees { " C = '...... 340 P,S,F, Z-z.., 1 I ~ ; >- <( I ...J 0 I l/)l/) l/)l/) I q <(<( ...J...J 00 ~ oq I UJ:r (jj i;:0 -<( z , (/) ::><( a: I w I- W 0 ::i; I a:: ..J <l: 0 ..J 2 ::i; <l: 0 I I> l- (/) a: UJO zZ W -<( , (/) I- lI.l/) I ::J W I ::i; I" l <l: i (/) 0 ...J"': I w ...in: N W - ..J (/) U I- UJ W l/)O I > a: a::z w q <l: <(<( I-' 0- Ol/) 1<, (/) 0 ~ . ' 1 09 0 _lC'l , . H- I I: .c ..J I UJ 0 > <( z a:: " <!) I ; 0 :r 2 l- I a. -- UJ 0 0 g 2 0 ~ 2 0 0 I'- <t I PER CENT FINER BY WEIGHT GRAIN SIZE DISTRIBUTION I By: WLS Dale: Iz/ol EXHIBIT TE"'E-CIIl.A NUMBER LA CoL.I J-IA 1C.oAl> 2~ J.N. 'Z1'?95 -01/02 - ,- - " - . I I I 1 I I I I I I I I I I I I I I 1 APPENDIX C ~~ . 1 1 1 1 1 1 I I 1 1 1 I 1 1 I I I I I STANDARD GRADING AND EARTHWORK SPECIFICATIONS These specifications present Earth Technics Inc., standard recommendations for grading and earthwork. No deviation from these specifications should be permitted unles!\ specifically superseded in the geotechnical report'Dfthe projector by written communication signed by the geotechnical consultant. 'Evaluations performed by the geotechnical consultant during the course' of grading may result in subsequent recommendations which could supersede these specifications or therecommendations of the geotechnical report. 1.0 General 1.1 The geotechnical consultant is the owner's or developer's representative on the project. For the purpose of these specifications, observations by the geotechnical consultant include observations by the soils engineer, ; geotechnical engineer, engineering geologist, and those performed by . "persons employed by and responsible to the geotechnical consultant. 1.2 All clearing, site preparation, or earthwork performed on the project shall be conducted and directed by the contractor under the supervision of the geotechnical consultant. 1.3 The contractor should be responsible for the safety of the project and satisfactory completion of all grading. During grading, the contractor shall remain accessible, 1.4 Prior to the commencement of grading, the geotechnical consultant shall be employed for the purpose of providing field, laboratory, and office services for conformance with the recommendations of the geotechnical report and these specifications. It will be necessary that the geotechnical consultant provide adequate testing and observations so that he may determine that the work was accomplished as specified. It shall be the responsibility of the contractor to assist the geotechnical consultant and keep him apprized of work schedules and changes so that he may schedule his personnel accordingly. 1.5 It shall be the sole responsibility of the contractor to provide adequate equipment and methods to accomplish the work in accordance with applicable grading codes, agency ordinances"these specifications, and the 2:S""" . 1 I 1 I I I I I 1 I 1 1 I I I I I I I STANDARD GRADING AND EARTHWORK SPECIFICATIONS PAGE 2 approved grading plans. If, in the opinion of the geotechnical consultant, unsatisfactory conditions, such as questionable soil, poor moisture condition, inadequate compaction, adverse weather, etc., are resulting in a quality of work less than required in these specifications, the geotl:\chnical consultant will be empowered to reject the work and recommend that' construction be stopped until the conditions are rectified. 1.6 It,is the contractor's responsibility to provide access to the gt;otechnical consultant for testing and/or grading observation purposes. This may require the excavation of test pits and/or the relocation of grading equipment. 1,7 A final report shall be issued by the geotechnical consultant attesting to the contractor's conformance with these specifications. 2.0 SITE PREPARATION 2.1 All vegetation and deleterious material shall be disposed of off-site. This removal shall be observed by the geotechnical consultant and concluded prior to fill placement. 2.2 Soil, alluvium, or bedrock materials determined by the geotechnical consultant as being unsuitable for placement in compacted fills shall be removed from the site or used in open areas as determined by the geotechnical consultant. Any material incorporated as a part of a compacted fill must be approved by the geotechnical consultant pril?r to fill placement. 2,3 After the ground surface to receive fill has been cleared, tit shall be scarified, disced, or bladed by the contractor until it is uniform and free from ruts, hollows, hummocks, or other uneven features which may prevent uniform compaction. 2.(:. . 1 1 I I I I I I I I 1 I I I I 1 I I I 3.0 . STANDARD GRADING AND EARTHWORK SPECIFICATIONS PAGE 3 The scarified ground surface shall then be brought to optimum moisture, mixed lis required, and compacted as specified. If the scarified zone is greater than twelve inches in depth, the excess shall be removed and placed in lifts not to exceed six inches or less. , " Prior to placing fill, the ground surface to'receive fill shall be observed, tested, and approved by the geotechnical consultant. 2.4 Any underground structures or cavities such as cesspools, cisterns, mining shafts, tunnels, septic tanks, wells, pipe lines, or others are to be removed or. treated in a manner prescribed by the geotechnical consultant. 2.5 In cut-fill transition lots and where cut lots are partially in soil, colluvium or unweathered bedrock materials, in order to provide uniform bearing conditions, the bedrock portion of the lot extending a minimum of 5 feet outside of building lines shall be overexcavation a minimum of3 feet and replaced with compacted fill. Greater oveiexcavation could be required as determined by geotechnical consultant where deep fill of20+ feet transitions to bedrock over a short distance. Typical details are given on Figure D- L COMPACTED FILLS 3.1 Material to be placed as fill shall be free of organic matter and other deleterious substances, and shall be approved by the geotechnical consultant. Soils of poor gradation, expansion, or strength characteristics shall be placed in areas designated by geotechnical consultant or shall be mixed with other soils to serve as satisfactory fill material, as directed by the geotechnical consultant. , 21 1 1 1 I I I I I I I I I 1 I I I I I I STANDARD GRADING AND EARTHWORK SPECIFICATIONS PAGE 4 3.2 Rock fragments less than twelve inches in diameter may be utilized in the fill, provided: 1. They are not placed in concentrated pockets. 2. There is a minimum of75% overall of fine grained material to surround the rocks. 3. The distribution of rocks is supervised by the geotechnical consultant. 3.3 Rocks greater than twelve inches in diameter shall be taken off-site, or placed in accordance with the recommendations of the geotechnical consultant in areas designated as suitable for rock disposal. (A typical detail for Rock Disposal is given in Figure D-2. 3.4 Material that is spongy, subject to decay, or otherwise considered unsuitable shall not be used in the compacted fill. 3.5 Representative samples of materials to be utilized as compacted fill shall be analyzed by the laboratory of the geotechnical consultant to determine their physical properties. If any material other than that previously tested is encountered during grading, the appropriate analysis of the is material shall be conducted by the geotechnical consultant as soon as possible. 3.6 Material used in the compacting process shall be evenly spread, watered, processed, and compacted in thin lifts not to exceed six inches in thickness to obtain a uniformly dense layer. The fill shall be placed and compacted on a horizontal plane, unless otherwise approved by the geotechnical consultant. 3.7 If the moisture content or relative compaction varies from that required by the geotechnical consultant, the contractor shall rework the fill until it is approved by the geotechnical consultant. "i' 3.8 Each layer shall be compacted to 90 percent of the maximum density in compliance with the testing method specified by the controlling governmental agency or ASTM 1557-70, whichever applies. 2e . 1 I I I 1 1 I I 1 I 1 I 1 I I I I I I STANDARD GRADING AND EARTHWORK SPECIFICATIONS PAGE 5 If compaction to a lesser percentage is authorized by the controlling govemmental agency because of a specific land use of expansive soil condition, the area to receive fill compacted to less than 90 percent shall either be delineated on the grading plan or appropriate reference made to the area in the geotechnical report. 3.9' All fills shall be keyed and benched through all topsoil, colluvium alluvium, or creep material, into sound bedrock or finn material where the slope receivin'g fill exceeds a ratio of five horizontal to one vertical",in accordance with the recommendations of the geotechnical consultant. 3.10 The key for side hill fills shall be a minimum width of 15 feet within bedrock or'nrm materials, unless otherwise specified in the,geotechnical report. ( See detail on Figure D-3. ) 3.11 Subdrainage devices shall be constructed in compliance with the ordinances of the controlling governmental agency, or with the recommendations of the geotechnical consultant. (Typical Canyon Subdrain details are given in Figure D-4. ) 3.12 The contractor will be required to obtain a minimum relative compaction of 90 percent out to the finish slope face of fill slopes, buttresses, and stabilization fills. This may be achieved by either over building the slope and cutting back to the compacted core, or by direct compaction of the slope face with suitable equipment, or by any other procedure which produces the required compaction approved by the geotechnical consultant. 3.13 All fill slopes should be planted or protected from erosion by other methods specified n the geotechnical report. 3.14 FiIl-over-cut slopes shall be properly keyed through topsoil, colluvium or creep material into rock or finn materials, and the transition shall be stripped of all soil prior to placing fill. (See detail on Figure D-3. ) 2.~ . I I I I I I I I I I I I I I I I I I I 5.0 . STANDARD GRADING AND EARTHWORK SPECIFICATIONS PAGE 6 4.0 CUT SLOPES 4.1 . The geotechnical consultant shall inspect all cut slopes at vertical intervals not exceeding ten feet. 4.2 If any conditions not anticipated in the geotechnical report such as percl1~ . water; seepage, lenticular or confined strata of potentially adverse nature, . unfavorably inclined bedding, joints or fault planes encountered during grading, these c6nditions shall be analyzed by the geotechnical consultimt, and recommendations shall be made to mitigate these problems. (Typical details for stabilization of a cut slope are given in Figures D-3a and D-5. ) i\ 4.3 Cut slopes that face in the same direction as the prevailing drainage shall be protected from slope wash by a non-erodible interceptor swale placed at the 'j top of the slope. 4.4 Unless otherwise specified in the geotechnical report, no cut slopes shall be excavated higher or steeper than that allowed by the ordinances of controlling governmental agencies. 4.5 Drainage terraces shall be constructed in compliance with the ordinances of controlling governmental agencies, or with the recommendations of the . geotechnical consultant. TRENCH BACKFILLS 5.1 Trench excavations for utility piiJes shall be backfilled under the supervision of the geotechnical consultant. 5.2 After the utility pipe has been laid, the space under and around the pipe shall be backfilled with clean sand or approved granular soil to a depth of at least one foot over the top of the pipe. The sand backfill shall be uniformly jetted into place before the controlled backfill is placed over the sand. 5.3 The on-site materials, or other soils approved by the geotechnical consultant shall be watered and mixed as necessary prior to placement in lifts over the sand backfill. 30 1 I 1 I I 1 1 I 1 I I I I I I I I I I STANDARD GRADING AND EARTHWORK SPECIFICATIONS PAGE 7 5.4 'The controlled backfill shall be compacted to at least90 percent of the maximum laboratory density as detennined by the ASTI D1557-70 or the controlling governmental agencies. 5.5' Field density tests and inspection of the backfill procedures shall be made by the geotechnical consultant during backfilling to see that proper moisture content arid unifonn compaction is being maintained., The contractor shall provide test holes and exploratory pits as required by the geotechnical consultant to enable sampling and testing. 6.0 GRADING CONTROL 6,1 Inspection of the fill placement shall be provided by the geotechnical consultant during the progress of grading. 6.2 Ih general, density tests should be made at intervals not exceeding two feet of fill height or every 500 cubic yards of fill placed. This criteria wilI vary depending on soil conditions and the size of the job. In any everit, an adequate number of field density tests shall be made to verifY that the required compaction is being achieved. 6.3 Density tests should also be made on the surface material to receive fill as required by the geotechnical consultant. 6.4 All c1eanout, processed ground to receive fill, key excavations, subdrains, and rock disposals should be inspected and approved by the geotechnical consultant prior to placing any fill. It shall be the contractor's responsibility to notifY the geotechnical consultant when such areas are ready for inspection, , 2:1\ . I I I I I I I I I I I I I I I I I I I . STANDARD GRADING AND EARTHWORK SPECIFICATIONS PAGE 8 7.0 CONSTRUCTION CONSIDERATIONS 7.1 Erosion control measures, when necessary, shall be provided by the contractor during grading and prior to the completion and construction of p,ermanent drainage controls. 7.2 Upon completion of grading and termination of inspections by the geotechnical consultant, no further filling or excavation, including that . necessary for footings, foundations, large tree wells, retaining walls, or other features shall be preformed without the approval of the geotechnical consultant. 7.3 Care shaIl be taken by the contractor during final grading to preserve any berms, drainage terraces, interceptor swales, or other devices of permarient nature on or adjacent to the property, r:' 2:.2.. I I I I I I I I I I I I I I I I I I I TRANSITION LOT DETAILS CUT-FILL LOT NATURAL GROUND \ ' ---- -- -- -- ---- --- -- __ .-- -- :.......- __ 5' L __ __ -- ___ ___ MIN. I ~ --\: --- . :COMPACTED ::'FILi.:-:-:::-==-~-:::':"--OC~~--~~----':--I:------------::: 30" MIN. _________________..."i ---.>:-: .", lI\ .. .<>". -.-- ____________--c:..---.--\'t.'r.:--..--'" . \ l' --:~~~Wif:.t~~~:~: OVEREXCAVATE AND RECOMPACT ,---""'-\.--07IOC-y-::..-.- n". ^ ---.. ,'oj .------ --=-.,,'C.\~_-...:::..:-:::-_-.:.:.:- --- . II \ UNWEATHERED BEDROCK OR ,1 ,--- MATERIAL APPROVED BY - -~ 1 THE GEOTECHNICAL Co.NSULTANT CUT LOT - .._. NATURAL GROUND ~-- - ---- -- -- - -- -- ---- - - -- _ -::::::. REMOVE _ __ - \?NSUITABLE ~ _ - _:.- - MATERIAL _ ::::==_=~~-=-:::~-=--=.:------_-_-----.:-::;.. ~-------':----T-':-":-=----':': -=------.:---- ., _ __ _' __ _ ",y, V\ /^ '-COMPACTED :::------.=-::::::-- \ __-=':~~;.:~-=I OVEREXCAVATE AND RECOMPACT --- --- --- --- --- UNWEATHERED BEDROCK OR f ,--- MATERIAL APPROVED BY - t THE GEOTECHNICAL CONSULTANT NOTE: ?eeper o".erexcavation and recomooclion sholl be p~rformed., , If de!ermmed -0 be necesscry by the geotec"nicCI consultant. ~ . I I I I I I I I I I I I I I I I I I. I . BENCHING DETAILS FILL SLOPE V' _-=-====~c-i~p ;'c-rio -~==: ~=-. _ :_-_-_-_-:_-:...: FILL ::-.:---------~ ~==~:~=~~t~~==~~:~ _-__ _=_ :_____-_-_- -=-_-;~ ____---- - --::1' _____________-----...c'~ ,"",^, i PROJECTED PLANE ---::--------:;~-----~-- I to I moxl'mum from toe :_-:::----:;.:-Z"'--:::....[~ =-='\"'." _______~-__--~_ N~ of slope to approved ground _-~-:-:-7=:?--';::7:: . ' , _-:::.7~-----:;-=-f t "'>;~ REMOVE :;...?:::::_--::-::"11; } UNSUITABl..!:: , , ----::-'?------..=:::7~~-;;. ~~ ,MATERIAL " _ _ -- - 4' MIN. "- ". -:r----:;.:=-------: BE"CH BENCH ./-__,-------- I'" . I'" l - _.._--------- HEIGHT -L- _-:::-::::-2%MIN::::-::::-:':- (typical) VARIES ------::----- T ,^.... '^'V 2' MIN. I 15' MIN. I KEY \*"LOWEST BENCH --, DePTH' (KEY) NATURAL GROUND \ _-: COMP ACTED ::--=-=-:;::::- : :::-~ Fl LL :-_-.7::...-:_- ----------------..-...:::::---.:_-2'" '" -------------~~ _-=~====~==LC-------:;...-~---] ____~_____:..?'i ."''<;;:/1'" ----------.....--; I _--=-::--::::--------~~---3: ... REMOVE, NATuRAL ~~-=-:.:-=-~~ UNSUlIABLE GROUND ~-_-_-_-:_-------1->. I MATERIAL __ ~ -- ::-:=:::-~=9 '/0."'1' L 4' MI~ "" __ -- ---.;::...--.c-_-:_--J \' BErK.. I --\ __ -- ~2%M1N.~-': (t,;,piCQ[~ -- _ - \ --. ,~.........., r-.' __ -'(f'..' ..--~___..- ~15' MIN.-J ___ ___ --- I LOW"ST BENCH \ F1LL OVER' CUT stOPE \ BENCH HEIGHT V;.?IES -- CUT FACE To be constructed prior 10 fill placement --- -- No""" NOTES: LOWEST BENCH: Oeplhond width subject to field change , based c.' consultant's inspec lion. S~'!ODRA1:JAGE:, e",;, ce,:':":; m:::y be required at the "::.........._t'r'ln nr th.... ,.,~otecnnicnl (""'nn::;uttont. ~ I I FOUNDATION AND SLAB RECOMMENDATIONS FOR EXPANSIVE SOILS (ONE AND TWO-STORY RESIDENTIAL BUILDINGS) I EXPANSION INDEX 0-20 VERY lOW EXPANSION EXPANSION INDEX 21 -: 60 lOW EXPANSION EXPANSION INDEX 51 - gO MEDIUM .EXPANSION EXPANSION INDEX 81 - 130 HIQH EXPANSION I ''',TOftY fOOTlNOa ALL fOOTINOI 12 IMeNU OUP. fOOTtHOI CONTlNUOUI. NO U[U IU:OUUU:O fOft UPANSION ,often. ALL rOOTlNOI 12 INCHEI ou,.rOOltHOI COHTIMU'OOll. 1-1'10." IAft TO' AND lOTTO". EXTER'Oft !'OOTlNOI 11 IHCHEI OU:'. INfEftlOft "OOTINOI 1% IHCHE. DEEr. t-NO. .. IAft TO" AND IOTTOW. [XTfIUO" I'OOltHOI U INCHE. . ou". "'U"IO" fOOTINOS .12 IMeNU DEEI'. 1-NO. , IAft lO" AND 10TTOW. I I-ITO,"'" fOOTINGS ALL rOOllNOS 11 IMeNU DEE". I'OOTIHOI CONTINUOUS. NO ITUl ,,[OOII'1EO I'D" [X'''N$lO" ,OfllCU. All fOOTlNOI 11 tt4CHU ou... 'DO lIMOS CONTINUOUS. 1-NO." ."" Tor AMD aOTTOw. ALL ..OOTINO' 11 INCHES DfEr. ,-OOTlHoa CONTINUOUI. 1-NO. 4 'AR .TO,. AND .OTTO.... EXTUUOR FOOTlNaS u INCHEa DU". IMURIO" FOOTINOS 11 INCHEa DEEr. 1-NO. . aAR Tor AND aOTTOw. I ~A'R";OE DOOR ORAOE 'EA'" feOT"(;~O. 12 INCHtI O[Er. 1-1010. . IAft Tor AND .OTTO.... n INCHEI DEEr. 1-"0.. aAft TO" AND aOTTOW. 24 .'(eNE' DEEP. I-HO. . IAI\ TOP -AND 10TTOW. I lIVtHQ AMA 'LOOR aLAas 1111 INCHES THICK. feD IoI[SH '112 IMCWEI THtCK. I 112 IHCHEI THICK. . INCHEa THICK. I X I-I" ftEOUIREO FOf! ExrANSION I x 1-'0/10 WIRE ...[IH At I X 1-10/10 WIRE ...EIH AT WIII;E UESH AT "'IO-HEIONT. FORCES. NO aAIE REOVIIfED. WID-NOQHT.2 INCHU ..1l0-HEIQHT. '" r.(CHES NO. S DOWELL' "II;Ow_ fOOTINO . ...IL VlSOVEEN 1ol01STUI\~ OIlAYU 0fI IAHO aAIl. . ORAVEl.. Oil; I"NO lASE. I TO SlAI AT II tHCHES ON aAIUUEIl rLUS 1 IHCN lAND. WIl VIIOUHN ...OIITUJIIE "'Il VlSOUEEN MOISTURE CfNTEIl. .. IftCHES QIlAYEl OR IA""IE" 'PlUS 1 IHCH 8AND. I""U'IIER PLUS 1 IHCH lAND. lAND IAIE. . Wll VISOU(EN WOISTURE 8A'IIUE" rlUS 1 INCH IAHO. GARAGE flOOR SLAIS 1112 INCHU THICK. NO WUH S 112 INCHES THICK. , 112 INCHES THICK. .. INCHES THICK. I X 1-"1 REOUlRED FOR EXPANSION I X 1-10/10 WIRE WE IN OR I X '-10110 WIRE \oCESN OR WIRE WESN OR OUARtE" FORCES. NO lASE "EO""R[D. OUAIHER IIl"'S. ISOLATE OUARTER l!Il~,'S. ISOLATE alAB'. ISOLATE FRON StEw HO "'OI,TURE IARRIER F"OIol STEW WALL FOOTIHOI. FROW STEU WALL FOOTIHOS. WAlL FOOTIHOS.ol INCHES REOUIREO. 2 IHCHES PlOCK. GRAVEL OR .. IHCHES ROCK. ORAVEl OR ROCK. OFlAVEl Of! SAND lIASE. SAND lIASE. NO MOISTURE SAND BASE. HO 1ol0lSTURE NO wOISTURE aARRIEI\ 'AAAIEI\ REOU1RED. BARRIER REOUIRED. REOl,/lREO. "'U-30.~kll-lO OF LIVINO I-IOT REOUlRED. UOISTEN SOU; TO 12 II-lCHES DEPTH 1I0AK TO II! "CHES OErTH 10AK TO 2. INCHES DEPTH TO A"EA AND OARAOE SlA' rRIOR TO rOURING TO ." AllOVE orTlIolUu TO II~ AIIOVE OPTlIolUIol 111. AlIOVE OPTIIotIJlolIolOISTURE aOll' CONCRETE. 1ol01STURE COl-lTE.NT. 1ot01:"URE CONTENT. CONTENT. I I I I NOTE I: ,) All OEPTH3 ARE RELATlVE'TO SlAlI SUBGRADE. 2) SPECIAL OESION IS REOUIRED FOR VERT HIGNLY ElPANSIVE SOlll. I FOUNDATION AND SLAB DETAIL I (NOT TO SCALE) I OOWEl :H'" SUlIGRAOE\ Wl:l.t "';:$"-, (WH<" ",OU,""'\. \ "^", \ I G~' ..,...... .~---'_...:...~\'.--;/ .... ~ ~....:;.,:,-:::;'.;;:).n.,.,.!...... . ., ~ g. II ;::,::~::, /_ rQR..VElOI\ s....o . ~Sl (...~,.. ", o::.u."-I 01 / I '~.':D-u'".. n:"':;. ....".<... ~ v'r1.,'.""'(\-: ';,: . ',.' I I I FOUNDATION AND SLAB RECOMMENDATIONS JOB NO.: 'DATE: FIGURE NO.: I EARTH TECHNICS 35' . I I I I I I I I I I I I I I 1 I I I I APPENDIX D ~ . I I I I I I I I I SURFICIAL SLOPE STABILITY --- Ct,,& 0( ~ Q. \l~S ;) I;" 0( . 0.4.4 (, \tlV1 f/ ~ 0.S32 S.F. = H elf B) cos20( tan ~ + C Ifs H Sin eX cos 0<. zone of satura'tion fS> M (t~ ,0) (ceol )(os?~) +--34 Q H (\?O,<I-)(O.Mb)(o.\l~S) = ZblL' H ( 28. O)f! ) -t 34<> ll( ""'-.o'?) I I I I I I I I I J:::s-,,- H = Depth of saturation zone ~B = Bouyant weight of soil. = 68.D 6's = Total wet weight of soil = \?D.4 ~ = Angle of internal friction = t8 C = Cohesion = ?4o S.F. = = H' S.F. Z- ? .~'Z. - 4 1.1'J Project No.: Calc. by: Chk. by: Date: . '.213~S- 01 wU W~ 12-}19/0 \ ~1 I I I 1 I I I I I I I I 1 I I I I I I APPENDIX E ~ - I I I I I I I I I I I I I I I I I I I PUBLISHED REFERENCES Blake, T.F., 1998, Computer Services Software, A Computer Program for the Probabilistic Evaluation Horizontal Acceleration from California Faults, FRISKSP, July 1998 Blake, T.F., 1998, Comnputer Services Software, A Computer Program to Determine Historical Seismicity from Digitized California Faults, EQSEARCH, July 1995 Bolt, B.A., 1973, Ouration of Strong Ground Motion: Proc. Fifth World Conference on Earthquake Engineering, Paper No. 2927 Coduto, D.P., 1987, Oown to Earth Soils Engineering, Vol. 1, Engineering Properties of Soils, Calif. Poly. University, Pomona, 193 pages. Clark, M.W., Harms, K., et al., 1984, Preliminary Slip-Rate and Map of Late-Quaternary Faults of California, U.S.G.S. Open-File Report 84-106, 12 p. DWR, 1971 Water Wells and Springs in the Western Part of the Upper Santa Margarita River Watershed, Riverside and San Diego Counties, California", Bull. No. 91-20, 377 Hart, E.W., 1997, Fault Rupture Hazard Zones in California, C.D.M.G. Special Report No. 42, 25p Hays, W.W., 1980, Procedures for Estimating Earthquake Ground Motions, U.S.G.S. Professional Paper 1114, 77p Kennedy, M.P., 1977, Recency and Character of Faulting Along the Elsinore Fault Zone in Southern Riverside County, California, C.D.M.G. Spec. Report 131, 12 pages Peterson,M.P., Bryant, W. A., Cramer, C.H., Reichle, M.S., 1996, Probabilistic Seismic Hazard Assessment for the State of california, C.D.M.G. Open-File Rept. 96-08 Seed, H.B., and Idriss, I.M., 1982, Ground Motion and Soil Liquefaction During Earthquakes, E.E.R.I. Nomograph, 134p, Berkley Press Slemmons, D.B., 1977, State-of-the-Art for Assessing Earthquake Hazards in the united States, Army Corps of Engineers, Misc. Papers, S-73-1, Repoort 6, Fault and Earthquake Magnitude, 240p Weber, F.H. Jr., 1977, Seismic Hazards Related to Geologic Factors, Elsinore an d Chino Fault Zones, Northwestern Riverside County, California, cDMG Open-File Report 77-5 LA, 96 pages ~