Loading...
HomeMy WebLinkAboutTract Map 3883 Lot 147 Rough Grading I I I I I I I I I I I I I I I I I I I 32'23 Lot 11.}-1 ......!!Ii ~ ~ _ f;;*~" ~.*?"*~* 4~ ~ ~_~ ]:....~'..J.....J,III1..:""I11I1I1......m...._.n.. _~............n._ --~~~-~ ~ ~ EnGEN Corporation . Soil Engineering . Te~lng . Co~ruc'on Ma1enols Tesllng . laboratory Tesling . . Environmental Site Assessments. Hazardous Materials Site Cleanup. Environmental and Geotechnical Engineering Network Corporation . Speciallnspec'ons . Geology' Englneenng Geology . .GEOTECHNICAl REPORT OF ROUGH GRADING Lot 147 otTract 3883 APN: 919-131-011 City of Temecula. Riverside County, California Project Number: T4366-C August 8, 1996 Prepared for: Mr. and Mrs. Torn Fisher 40711 Calle Medusa Temecula, California 92591 Los Angeles Office Post Office Box 1497 LancasfSf, CA 93534 (805)940-1200 I Fax: 940-1202 Corporate Office \ Orange COunty Office 2615 Orange Avenue SOnto Ana. CA 92707 (714) 546-40511 Fax: 546-4052 41607 Enterprise Circle North, Suite 1 . Temecula . California 92590 . (909) 676-3095 . Fax: (909) 676-3294 I I' I I I I I I I I I I I I I I I I I Mr. and Mrs. T. Fisher Project No. T4366-C TABLE OF CONTENTS SECTION NUMBER AND TITLE PAGE 1.0 PROJECT DESCRIPTION ...............................................................................................1 2.0 SITE DESCRiPTION........................................................................................................ 1 2.1 Location 2.2 Topography and Surface Conditions 3.0 SCOPE OF WORK ..........................................................................................................2 3.1 Time of Grading 3.2 Equipment 3.3 Grading Operations 4.0 TESTING .................................................................................................................. 3 4.1 Field Testing 4.2 Laboratory Testing 4.2.1 Moisture-Density Relationship Test 4.2.2 Expansion Index Test 5.0 EARTH MATERIALS ....................................................................................................... 4 6.0 CONCLUSIONS AND RECOMMENDATIONS ...............................................................4 6.1 General 7.0 CLOSURE .................................................................................................................. 5 APPENDIX: FIELD TEST RESULTS LABORATORY TEST RESULTS DRAWINGS EnGEN Corpor3.tion 1.-.- I I I I I I I I I I I I I I I I I I I ';.fFh ~"$t* ~~_ *~ ~ lEJ~I! ~ ~~ J!:'J!;\~F.'tr?\~ <<', "" 1t>!.1(\. tI:\ E GEN C . . Soil Engineering. Testing. ConstnJctlon Matertals Testing. Laboratory Testing. n orporatlon . Environmental Site Assessments. Hazardous Materials Site Cleanup. Environmental and Geotechnical Engineering Network Corporation . Special Inspections . Geology' Engineenng Geology . August 8, 1996 Tom and Debbie Fisher 40711 Calle Medusa Ternecula, California 92591 (909) 695-3844 Regarding: GEOTECHNICAL REPORT OF ROUGH GRADING Lot 147 ofTract 3883; APN: 919-131-011 40285 Paseo Del Cielo Temecula, Riverside County, California Project Number: T4366-C Reference: Bratene Construction & Engineering, undated, Precise Grading Plan for the Fisher Residence, Lot 147, Tract 3883, City of Temecula, Riverside County, California; LD96-061 GR. 2. Soil Tech. Inc. Letter, dated May 14, 1996, Soils Report, Single Family Residence, 40285 Paseo Del Cielo, Temecula, CA, LD 96-061GR. 1. Dear Mr. & Mrs. Fisher: According to your request and signed authorization, EnGEN Corporation has performed field observations, sampling, and in-place density testing during the rough grading operations for the referenced site. Submitted, herein, are the results of the findings and the supporting field and laboratory data. 1.0 PROJECT DESCRIPTION The referenced grading consisted of preparing a house and garage building pad. The referenced site was graded to the elevations as shown on the Reference NO.1 Plan. 2.0 SITE DESCRIPTION 2.1 Location: The subject property is located on the northwest side of Paseo Del Cielo, in the city of Temecula, Riverside County, California, as shown on the Vicinity Map presented in the Appendix. Los Angeles Offlce Orange COunty Office Post Office Box 1497 2615 Orange Avenue lancaster, CA 93534 Santo 1V'ta. CA 92707 (805)940-1200 I Fax: 940-1202 ffi 1714)546 40511 F-' 546 4052 Corporate 0 Ice . ....A.- 41607 Enterprise Circle North, Suite 1 . Temecula . California 92590 . (909) 676-3095 . Fax: (909) 676-3294 3:> I I I I I I I I I I I I I I I I I I I 3.0 3.1 3.2 3.3 Mr. & Mrs. T. Fisher Project No. T4366-C August 1996 Page 2 2.2 Topoqraphv and Surface Conditions: Topography of the site was moderately to gently sloping hillside with sheetflow drainage toward the northwest at an average gradient of 18 percent. A stockpile of approximately 1600 cubic yards of imported material existed on the western portion of the site prior to grading. The site was vacant of any man-made structures. The site was covered with a light growth of native vegetation such as grasses and weeds. SCOPE OF WORK Time of Gradinq: Grading operations were conducted from June 19 through July 2, 1996. Equipment: The grading operations for the house and garage pad were performed by One Tractor Doze It All through the use of one (1) Caterpillar D8K track mounted dozer, one (1) John Deere 450 track-mounted dozer, and one (1) fire hose attached to a hydrant. Gradinq Operations: Grading within the house and garage pad consisted of a cut! fill operation. Clearing of grasses and weeds was performed prior fill placement. Fill material was generated from the previously existing stockpile in the western portion and the cut in the southern portion of the lot to bring the northern and northwestern portions of the site to finish grade elevation. At the onset of grading, a 10-foot wide key, a minimum of 2.0-feet deep, was excavated at the toe of the fill slope. As fill was placed, benches were cut into the natural ground such that all fill was placed on level ground. Overexcavation was performed in the cut portion on the southern portion of the building pad to a minimum depth of 3.0-feet below finish grade elevation. The exposed bottom was scarified and moisture conditioned a depth of 6.0-inches, then compacted to 90 percent. Fill was placed in lens thicknesses of 4.0 to 6.0-inches, thoroughly moisture conditioned to near optimum moisture content, then compacted to a minimum of 90 percent relative compaction. Moisture conditioning of the on-site soils was performed during the compaction process A.. EnGEN Corporation I I I I I I I I I I I I I I I I I I I Mr. & Mrs. T. Fisher Project No. T4366-C August 1996 Page 3 through the use of a fire hose attached to a hydrant. The pad area was generally graded to the elevations noted on the Grading Plan. However, the actual pad location, dimensions, elevations, slope locations and inclinations, etc., were surveyed and staked by others and should be verified by the Project Civil Engineer. 4.0 TESTING 4.1 Field TestinQ: Field observations and in-place density testing were performed on a part- time as-needed basis during the grading operations. Where tests indicate failing results, the soils were reprocessed until at least 90 percent relative compaction was achieved. Test locations were randomly selected in the areas receiving fill and were recorded using approximate locations and elevations as could be determined in the field. Field in-place density and moisture content testing were performed during the placement of the fill materials during the rough grading operations in general accordance with the following ASTM test procedures: Test Method for Density of Soil and Soil-Aggregate in Place by Nuclear Methods (Shallow Depths) - ASTM D2922-81 (1990). Test Method for Water Content of Soil and Rock in Place by Nuclear Methods (Shallow Depth) - ASTM D3017-88. The test results indicate that soils were compacted to a minimum of 90 percent relative compaction. Test results are presented in the Appendix. The locations of the in-place density tests are presented on the Rough Grading Report Site Plan in the Appendix. 4.2 Laboratory TestinQ: The following laboratory tests were performed as part of our services during the rough grading of the subject site. The test results are presented in the Appendix. 4.2.1 Moisture-Density Relationship Test: Maximum dry density - optimum moisture content relationship tests were conducted on samples of the materials used as fill. The tests were performed in general accordance with ASTM D1557-91 procedures. The test results are ~ EnGEN Corporation ,I I 'I I I I I I I I I I I I I I I I I I Mr. & Mrs. T. Fisher Project No. T4366-C August 1996 Page 4 presented in the Summary of Optimum Moisture Content I Maximum Dry Density Relationship Test Results. 4.2.2 Expansion Index Test: Soil samples were obtained for expansion potential testing from the building pad area upon completion of rough grading. The expansion test procedure utilized was the Uniform Building Code Test Designation Standard 29-2. The material tested consisted of a silty sand with traces of clay, which was visually judged as the most expansive fill material for the subject site. The material had an Expansion Index of 0 and a very low expansion potential as determined by Table 26-C-A of the Uniform Building Code. As a result, no special design or construction is required for expansive soils purposes. The results are presented on the Summary of Expansion Index Test Results. 5.0 EARTH MATERIALS The natural earth materials encountered on-site and the imported materials generally consisted of silty sands. 6.0 CONCLUSIONS AND RECOMMENDATIONS 6.1 General: Based on the observations and tests performed during grading, the subject site in the areas noted has been completed in accordance with the project plans and specifications, and the Grading Code of the City of Temecula. The 9raded site in the areas noted as rough graded is determined to be adequate for the support of a single family residential structure and appurtenant facilities. A small area in the immediate vicinity of the proposed retaining wall along the east property line was not filled at this time, pending the construction of the retaining wall and the associated backfill operation. Any subsequent grading for development of the subject property should be performed under engineering observation and testing performed by EnGEN Corporation. Subsequent grading includes, but is not limited to, any additional fill placement and excavation of (p EnGEN Corpoiation I I I I I I I I I I I I I I I I I I I Mr. & Mrs. T. Fisher Project No. T4366-C August 1996 Page 5 temporary and permanent cut and fill slopes. In addition, EnGEN Corporation should observe all foundation excavations. Observations should be made prior to installation of concrete forms and/or reinforcing steel so as to verify and/or modify, if necessary, the conclusions and recommendations in this report. Observations of overexcavation cuts, fill placement, finish grading, utility or other trench backfill, pavement subgrade and base course, retaining wall backfill, slab presaturation, or other earthwork completed for the development of subject site should be performed by EnGEN Corporation. If any of the observations and testing to verify site geotechnical conditions are not performed by EnGEN Corporation, liability for the safety and performance of the development is limited to the actual portions of the project observed and/or tested by EnGEN Corporation. 7.0 CLOSURE This report has been prepared for use by the parties or project named or described above. It mayor may not contain sufficient information for other parties or purposes. The findings and recommendations expressed in this report are based on field and laboratory testing performed during the rough grading operation and on generally accepted engineering practices and principles. No further warranties are implied or expressed beyond the direct representations of this report. Thank you for the opportunity to provide these services. If you should have any questions regarding this report, please do not hesitate to contact this office at your convenience. JDG/OB:df Distribution: (4) D:\ENGEN\REPORTS\COMPACTION\T4366C Fisher 1 EnGEN Corporation '-, I I I I I I I I I I I I I I I I I I I APPENDIX FIELD TEST RESULTS (Summary of Field In-Place Density Test Results) Mr. & Mrs. T. Fisher Project No. T 4366-C ~ EnGEN Corporation I I I I I I I I I I I I I I I I I I I Mr. & Mrs. T. Fisher Project No. T 43S6-C SUMMARY OF FIELD IN-PLACE DENSITY TEST RESULTS (Nuclear Gauge Test Method) TEST TEST DEPTH or SOIL MAX. MOISTURE DRY RELATIVE / REQUIRED NO. DATE TEST LOCATION ELEV. TYPE DENSITY CONTENT DENSITY COMPACTION (199S) (FT.) (PCF) (%) (PCF) (%) (%) 1 S/19 NW. Keyway 73W 1 127.8 8.3 124.2 97.2 90 2 6/19 NW. Fill 75.0' 1 127.8 8.9 123.0 9S.2 90 3 6/20 NW. Fill 77.0' 1 127.8 11.3 11S.9 91.5 90 4 6/20 W Fill 78.0' 1 127.8 10.0 118.8 93.0 90 5 S/21 N.W Fill 80.0' 1 127.8 11.7 11S.3 91.0 90 S S/21 W Fill 85.0' 1 127.8 112 119.2 93.3 90 7 6/21 N.E. Fill 82.0' 2 133.8 9.9 123.0 91.9 90 8 S/24 N.E. Fill 88.0' 1 127.8 8.2 118.1 92.4 90 9 S/24 N. Slope 89.0' 1 127.8 8.8 112.9 88.3 90 10 S/24 Bldg. Pad 90.0' 1 127.8 9.0 115.9 90.7 90 11 6/25 Retest of #9 89.0' 1 127.8 9.7 119.5 93.5 90 12 S/25 Bldg. Pad 93.0' 1 127.8 11.S 120.6 94.4 90 13 7/02 Bldg. Pad OIX 93.5' 1 127.8 10.5 115.0 90.0 90 14 7/02 Bldg. Pad 9S.0' 2 133.8 11.S 120.S 90.1 90 15 7/02 Bldg. Pad 97.0'(FG) 2 133.8 10.8 121.3 90.7 90 (*) indicates Processed Bottom (F.G.) indicates Finish Grade , EnGEN Corporation ~ I I I I I I I I I I I I I I I I I I I LABORATORY TEST RESULTS (Summary of Optimum Moisture Content I Maximum Dry Density Relationship Test Results) (Summary of Expansion Index Test Results) Mr. & Mrs. T. Fisher Project No. T 4366-C EnGEN Corporation VJ I I I I I I I I I I I I I I I I I I I Mr. & Mrs. T. Fisher Project No. T 4366-C SUMMARY OF OPTIMUM MOISTURE CONTENT I MAXIMUM DRY DENSITY RELATIONSHIP TEST RESULTS ASTM D1557-91 SOIL MAXIMUM OPTIMUM TYPE SOIL DESCRIPTION, (USCS Svmbol) DRY DENSITY MOISTURE CONTENT (PCF) (%) 1 Brown Silty Sand (Imported) 127.8 8.7 2 Brown Silty Sand 133.8 8.4 ~ EnGEN Corporation V\ I I I I I I I I I I I I I I I I I I I SOIL TYPE DEPTH (FT) 1.5 SUMMARY OF EXPANSION INDEX TEST RESULTS (UBC 29-2) SURCHARGE (PSF) 144 DRY DENSITY (PCF) 119.4 Mr. & Mrs. T. Fisher Project No. T 4366-C MOISTURE CONDITION EXPANSION BEFORE TEST AFTER TEST INDEX (%) (%) 7.3 14.8 o , \7-- EnGEN Corporation I I I I I I I I I I I I I I I I I I I Mr. & Mrs. T. Fisher Project No. T 4366-C DRAWINGS (Rough Grading Report Site Plan) , \~ EnGEN Corporation