Loading...
HomeMy WebLinkAboutTract Map 3929 Lot 19 Preliminary Geotechnical Investigation I II ! I I I I I I I I I I I I I I I I I Ear h. . echnlcs ,...... PREUMINARY GEOTECHNICAL INVESTIGATION Single - Lot, Residential Development Lot 19, Tract 3929, 28890 V"1lI Norte A.P.N.921-111-004 Temecula, California September 28, 2001 PROJECT NO. 21315-01 PREPARED FOR: Mr. Kenneth Murphy 520 Roosevelt Avenue Corona, California 92879 \ Earth Technics P.O. Box 891989, Temecula, California 92589 (909) 699-5451 FAX (909) 767-1193 - I I I I I I I I I I I I I I I I I I I I September 28, 2001 , Project No. 21315-01 1.0 INTRODUCTION At your request, we have performed a Preliminary Geotechnical Investigation for the above referenced site. The purpose of our investigation was to evaluate the underlying soil conditions with respect to the proposed development and to assess the geotechnical and engineering constraints that might exist considering this development. The 20-Scale Grading Plan prepared by Lakeshore Engineering, Canyon Lake, dated April 10, 2001 was used to direct our field work. Plate 1 presents our Geotechnical data obtained during our field investigation. ACCOMPANYING MAPS. ILLUSTRATIONS AND APPENDICES Index Map - (2000-scale) - Pqge 2 Geotechnical Map - (20-scale) - Plate 1 Regional Fault Map - (1" = 20 ~iles) -'Plate 2 Appendix A - Geotechnical Trench Logs , 1 Appendix B - Summary of Laboratory Test Results Appendix C - General Earthwork and Grading Specifications Appendix D - Slope Stability Appendix E - References ~ . I I I I I I I I I I I I I I I I I I I . INDEX MAP u!f1J'f /d xf4M~;S?p;l~(U '/ f ,-'.=Ao- ,,00), ~ 4iF'-"'. ~ ,tl/'("',; )~"'~ ""!C i'OO, ~ ~~. -- " I f I '-// , [/~o "/ u ,['" ...;y, '" ~ :ff2,~ 0 11 /~'f. ~~ ..~~~- ~ c- -=- \. ~A r-- '?OO , ~ o. .';< 0 :...c -~ I'" ' . ' ~ riff'" ;,;:i~I.1(1 ,,' /: '~ '~ ~ "'h.... ..;~~ 0 ~,\ // ' IJrrl7~~~~J, ,')-U.J . k ~ ~ ...u. ~...JAv4' --/ ~ ~' 1JY7 @,%( ~/"-- M "'i '''\..0 IX ~ ~rr~ . "200~ 1JffU-;:; CJ I~, (Q~ Ji 0 ,." ,', 'X" .. ~ ~ ~J ~ r:,/ ~ 1 ~) ~) 'YJIA ,p=' ~/ /" ow.ni.. "'" ~^" ~~~ ;?7~7~/l ~" ~. -tY.-~~'5Y , :".... D "', (Z<::;/~ o ~~ ~ ,/ ~ :' -; oo:tl" c...;:// '7 ~'\ \. "1 ';)- '" r~o::./ .~: .~. , ClJiL ~~~ ..i7~~z~~ ,:0. ~--',"'. , f((jfti5~ '1 '-~~vl~ ~ . " >~ <0"J'''''''';' ,~D ))..:> iI/oo:.. ~l ~0'7~ ~ ,~t-.. "" ~ ~:::--- ~j() ~\", ~~""o ....... \ L~~ ~ <> ~~ .7)~ (~~, 'l\~#<> :f< ~..,~'" i~ it'''-~fX:?'1r~ ~ ,""'~ "'~ ~. " ...~., / ~d(};-,:S\ -: <<;-~.~~;Ji ""~ L,,~ . /. " " -..) "'" /~~ 4 ,-~=x I~) ( .. 0 .,.~. ~ ---:'~ --u . . 3;(!Qt?/~ -:, V. ,of '.,', LillI> ,: '=" = -: '~ ,~C.7 :;? .--<:~" . 0 \'. ,:'-' :<ilII"" V, >ff ~ '{"~' '-'~~,....tIb if/p !.:_ ~.<; ". ' -".,' 'S77": ~ " --'? o=cs'd ~::; 1'--' '. 0 ~ (~.., ~J~R! W~~s- c::)y~--::- O?/1/6~ ~ ~ '? ~ .. )i'a~ c..~. ~Ig ~nyor)" , __:,.@0 ,,~::J ;;:~ "'" \l -J~~,"~'f~, ,': -..... Y;:Vif\ . \, 7/~" t".... ROAD. , ". '\.. ~:f&.."'~~ .." .\.~ VA':~~~ ~:~:)VJ~~ ~.~\:~--: ,~~"" ~. :' ~ :J/lo 0(ra.. ,( ""''L:6~'''''' ~~( ~"'<(~<'\ ::,'?'/;~_~ ,,\ ..:~~.~/) a ~:(-' ~~~ Co' $ ~~ ~... ..~,~, <9~., \ ' \u ~. ~,\ Y r.... _ 0...1\ ~,,111 <d~ / ',.,\..1>. ''''~'' ,..,~"" r;J~~~"-C::." .g;" < ~ . ".'''--' " \\,~ \-. .. "~:"'">:'o:",,_f ~.~~ ... ,~3',o< ~" " Ranchb.;\. __ ... \\:, _' ,,' ",". ','0,,': ~ '\:'.' /;;t' L~~f"~:t"~~:~~., ': ~ rr .\ "'L~, =:-'c'357u~~- \\.' ~~.,. ~ ~. -,'\, .,.:\~ ,,~er=;: S?( n7_~ ~Oo'- ~\ :,y I~~\. ~ l: i';e/I! ,".':,".. "" .l~. Ir-l . ". "~~'.\" 41 ~ r~ ')n n9, ; ,:.1: ::' ~'--: o . SCALE N 2000 4000 INDEX MAP feet 0 F LOT 19, TRACT 3929 28890 VIA NORTE TEMECULA, CALIFORNIA - 2 - SOURCE: U.S.G.S. 7;' MIN. QUAD. 14URRIETA 1953 (1979) :7 I II I I I I I I I I I I I I I I I I I 21315-01 Page 3 2.0 SITE LOCATION/CONDITIONS The roughly trapizoidal-shap~d 0,56+/- acre property is located on the north side of Via Norte, an improved paved road in the City of Temecula. Via Norte bounds the the property to the south, with existing houses to the east and west, and vacant land in all remaining directions. The Index Map (Page 2) presents the topographic and geographic relationships of the property to surrounding areas. Topographically, the site is uniformly descending 10-12 percent to the north from Via Norte, A broad gentle swale in located in the central portions of the lot, Total relief is 22 feet. No improvements exist at the site, The pad is covered by light grasses with a few weeds on the lower portions of the lot, 3.0 PROPOSED DEVELOPMENT The current concept is to build a 1 & 2-story single-family residence with access driveway from Via Norte. Grading will consist of 7-8 foot cuts on the south and fills to 12 feet on north. All slopes will be constructed at finished face inclinations of 2:1 (horizontal to vertical) or flatter, A 3 foot high retaining wall is planned in the southwest corner of the lot, Approximately 750 yard of import fill will be required to complete the pad. On-site sewage disposal will be utilized on extreme northern portions of the property not being graded. 4.0 SCOPE OF SERVICES The scope of our investigation included the following: 1. A review of available data pertinent to the site, 2. Subsurface exploration of 'the site utilizing 2 exploratory backhoe trenches to depths as great as 6,8 feet. The trenches were logged, and these logs appear in Appendix A of this report. The trenches were tested for in-place density utilizing the Sand Cone Method (ASTM D1556-64). Representative bulk samples were obtained for testing. 3, Laboratory testing of representative earth materials to develop soil engineering parameters for the proposed development. l\ . I I I I I I I I I I I I I I I I I I I 21315-01 Page 4 4. Preparation of this report presenting our findings, conclusions and recommendations concerning site development based upon an engineering analysis of the geotechnical properties of the subsoils as determined by field and laboratory evaluation. 5.0 LABORATORY TESTING The following tests were performed for this project in our laboratory in accordance with the American Society for Testing and Materials, the State of California Standard Specifications or contemporary practices of the soil engineering profession, 5,1 Maximum Densitv - Optimum Moisture Determinations This test determines the density that a soil can be compacted to at various contents. For each soil moisture, there is a maximum dry density obtained and the associated optimum moisture content. The results are used to evaluate the natural compaction, control of the grading process and as an aid in developing the soil bearing capacity. This is based on ASTM Standard D1557-78 (five layer method). \ 5.2 In-situ Moisture and Densitv These tests consisted of performing Sartd Cone Density tests (ASTM D1556-64) in the trenches to determine in-place moisture and density. The results are used to analyze the consistency of the subsoils and aid in determining the necessary grading to prepare the pad area. ' 5.3 Sieve Analvsis This test determines the material grading of the individual particle sizes and is used in generatirlg an engineering classification, 5.4 Sand Equivalent Testinq , ' This is a test for the rapid determination of the relative portions of fine silt and clay materials within the soil samples, and is used for a relative comparison of soils in the determination of the adequate paving sections for driveways, etc. 5.5 Expansion Testinq The expansion index of the soils are. determined by the U,B,C, Method 29-2 and is used to design foundations for anticipated expansion forces. 5 . I I I I I I I I I I I I I I I I I I I 21315-01 Page 5 5.6 Direct Shear A direct shear strength test was perfo~med on a representative sample of the on-site soils remolded to 90% relative compaction, To simulate possible adverse field conditions, the sample was saturated prior to shearing. A saturating device was used which permitted the samples to absorb moisture while preventing volume change. This test is used to determine soil strengths for slope stability evaluations and for foundation bearing capacity. 5.7 Soluble Sulfate A representative surface sample was tested to determine soluble sulfate content. The test results are used to recommended the type and strength of concrete to be used in construction. 6.0 SUBSURFACE CONDITIONS The lot is underlain by a thin soil/colluvium 2,5-3.5 feet thick that is soft and dry. In-place densities for the soil/colluvium fill were from 112.5 pcf (85.'5% relatiVe' compaction) in T-2 (2.0- 2.5 feet) to 114.8 pcf (87.2% relative'cbmpaction) in T-1 (1.8- 2.4 feet) and moistures of 3-4 percent.1 . The underlying pauba Formation bedrock 'was dense to very dense with in-place densities of 121.8 pcf (92,6% relative compaction) to 122,6 pcf (93,2% relative compaction) at depths of 3,5 - 4.0 feet, 7.0 GROUND WATER , No ground water seepage was encountered on the site to a depth of 6.8 feet. Historic high ground water is expected to be 57-60 feet at the lowest elevations at the rear of the lot based on historic ground water in nearby wells (DWR, 1978), No evidence of seepage was seen in the natural slope faces surrounding the property. 8.0 FLOODING According to the Federal Emergency Management Agency and the County of Riverside, the pad site is not located within the boundaries of a 100-year flood plain.. The large swale area just north of the rear property line had evidence of previous running water in a channel approximately 110 feet horizontally and 12 feet vertically below the northern lot line. No flooding potential exists at the site, ~ . I I I I I I I I I I I I I I I I I I I 21315-01 Page 6 9.0 GEOLOGY. The entire proposed building pad area is underlain at depths below 4 -5 feet by sedimentary bedrock identified as the pauba Formation (Mann, 1955; Kennedy, 1977). The poorly-developed bedding was oriented N15-20E and dipping 4-6 degrees NW, No evidence of slope instability exists at the site or in the adjoining cut slopes along Via Norte. The site is not included in any state or County fault hazard zone for active faulting. 10.0 SEISMIC SETTING/GROUND MOTION PARAMETERS The regional seismic setting is shown on Plate 2. The nearest active faults to the site include the wildomar Fault of the Elsinore Fault Zone which is located approximately 5.3 miles to the southwest, The Casa Loma branch of the San Jacinto Fault is located 22 miles to the northeast. The Elsinore Fault zone because of its proximity and seismic potential to the site is the design fault when evaluating the site seismic parameters. 11.0 HISTORIC SEISMICITY During the last 100 years in the San' B~rnardino/Riverside area, the greatest number of moderate to large earthquakes (greater than 6,0 M) have occurred along the San Jacinto Fault (Hileman, Allen and Nordquist, 1974; P~terson, et all, 1996). The most significant earthquake epicenter of magnitude 6,OM on the Elsinore Fault occured 12+ miles to the northwest in 1910 in Lake Elsinore. Several earthquakes of magnitude 6.8M and 7.0M have occurred on the Casa Loma and San Jacinto faults approximately 20-22 miles northeast. 12.0 SEISMIC EXPOSURE Although no precise method has been developed to evaluate the seismic potential of a specific fault, 'the available information on historic activity may be projected to estimate the future activity of the fault. This is usually done by plotting the historic activity in terms on number of events in a given time interval versus magnitude of the event, Based on such plots, recurrence intervals for earthquakes o~ given magnitudes may be estimated. A probabilistic evaluation of potential seismicity for the site utilizing FRISKSP (Blake f998) indicates a 10% probability of exceedance of 0.62g in ~O years assuming all seismic sources. . ~ . I I I I I I I I I I I I I I I I I I I 21315-01 Page 7 We have utilized strain rates of 5.0 rom/year for the Elsinore Fault suggested by Peterson, .et al (19~6) to estimate the maximum moment earthquake. We estimate the maximum moment magnitude or "design earthquake" to be 7.5 magnitude with a 10% possibility of exceedance in 50 years. This is in agreement with the probabilistic model by Blake, (1998). 12.1 1997 U.B.C. Seismic Parameters: The following UBC seismic parameters should be incorporated into seismic design: Nearest Active Seismic Source (Type B Fault) - 8.5 km Soil Type* - SD Near Source Factor N, - 1.0 Near Source Factor N, - 1.1 * Soil type may be Sc but requires, additional field work to verify. 13.0 GROUND MOTION CHARACTERISTICS The ground motion characteristics which could affect the site during the postulated maximum moment magnitude of 7,5 were estimated. Available information in the literature about maximum peak bedrock acceleration and its attenuation with distance (Joyner and Borzognia, 1994), the effects of site-soil conditions on surface ground motion parameters (Seed & Idress, 1982), and site response criteria (Hays, 1980) were utilized, The predominant period of bedrock acceleration is expected to be 0.30 seconds with 24 seconds of strong ground shaking (Bolt, 1973) . 14.0 SECONDARY SEISMIC HAZARDS The dense well-cemented nature of the underlying sedimentary bedrock in the area of the existing pad at depths as shallow as 4.0 feet, and the historic depth to ground water over 50 feet precludes such secondary seismic hazards as liquefaction, lateral spreading or settlement of the ground the house is being placed upon, No rockfall hazard exists at the:building site, The potential for seismically-triggered landslides is discussed in detail under the slope stability sectidn. e, . I I I I I I I I I I I I I I I I I I I 21315-01 Page 8 15.0 CONCLUSIONS AND RECOMMENDATIONS 15.1 Foundation Desiqn A strip and spread footing foundation system should provide an adequate foundation for one and two-story buildings in this site. All exterior footings should be founded a minimum of 18 inches below adjacent finished grade for two-story buildings, and 12 inches for one-story buildings. Interior footings may be founded a minimum of 12 inches below finished grade. When the footings are founded in properly compacted fill or dense bedrock, an allowable bearing capacity ,of 1800 psf for 15 inch wide footings is acceptable for dead plus live load. This value may be increased by one-third for short term wind and seismic loading conditions. When foundations are placed in natural soils, no cobbles over 6 inches should be left within the base of the foundation. A typical foundation design is included in Appendix C, Two No, 4 bars, 1 top and 1 bottom is recommended as a minimum design. 15.2 Settlement Our subsurface investigation revealed that the underlying sedimentary bedrock are dense and moisture conditioned, Based on soil strength values and in-place densities, footings should experience less than 1-inch settlement with less than 1/2 inch differential settlements between adjacent footings of similar sizes and loads over a distance of 50 feet horizontally,. This settlement is based upon grading of up 'to 25 feet of engineered and compacted fill, If thicker fills are proposed, settlement could be greater and should qe evaluated prior to placement. 15.3 Concrete Slabs-On-Grade Sufficient fine-grained materials exists within near surface earth materials to possible create moisture problems, Therefore, we recommend that a moisture barrier b~ placed under any concrete slabs that might receive a moisture-sensitive floor covering. This moisture barrier should consist of a 10-mil polyethylene vapor barrier sandwiched between a 2-i~ch layer of sand, top and bottom, to prevent puncture of the bar~ier and enhance curing of the concrete. Reinforcement of the slabs with 6x6-6/6 welded wire mesh centered in the 4 1nch slab is recommended, The subgrade below the slab should be moisture conditioned and properly compacted prior to placement of concrete. q . I I I I I I I I I I I I I I I I I I I 21315-01 Page 9 15.4 Expansive Soils - Soluble Sulfate' Expansion testing of near-surface silty sand soils (T-1 ; 0-3 feet) possible at finished grades indicate that the soils in the pad area are very low expansion. This is in accordance with the U.B.C. Table 18-B-1. No special design provisions are necessary for the foundation or concrete flatwork to resist expansion forces. The soluble sulfate content was 62 ppm allowing normal Type II concrete with 2500 psi strength. 15.5 Earthwork Shrinkaqe and Subsidence Shrinkage of the colluvium will occur during grading, estimated as 8-10 percent when recompacted to compacted fill standards. The sedimentary bedrock is expected to bulk 3-5% when placed as compacted fill, 15.6 Retaininq Wall Desiqn Retaining walls should be designed using the following parameters: ! o o o Active pressure Active pressure Active pressure (level backfill) (2:1 backfill) . (1 1/2:1 backfill) 42 lb/ft /ft 52 lb/ft /ft 58 lb/ft/ft For purpose of lateral resistance, a value of 0.35 may be used for frictional resistance. A value of 275 lb/ft /ft may be used for passive resistance for footings placed into properly compacted fill. Frictional and passive resistance may be combined, provided the later is reduced by one-third, , Special loads for dead plus actual loads should be considered in the driveway/parking area that is retained, 15.7 Lateral Loads Lateral loads in the near-surface soils are: Active At Rest Passive - 42 pounds per square foot of soil depth (psf/ft) - 58 psf/ft - 275 psf/ft (for wood shoring) 350 psf/ft (for concrete footings) Active means movement of the structure away from the soil; at rest means the structure does not move relative to the soil (Such as a loading dock); and Passive means th~ structure moves into the soil. The coefficient of friction between the bottom of the footings and the native soil 'may be taRen as 0.35, , \0 . I I I I I I I I I I I I I I I I I I I 21315-01 Page 10 15.8 Trench stability The near-surface soil to a depth of 5 feet should stand vertically when excavated, however, trenches in excess of 5 feet in depth should have the sides laid back at 1:1 in accordance with OSHA requirements. 15.9 SloDe stability The proposed graded slopes are 8 and 12 feet respectfulyly for cut and fill at finished face inclinations of 2:1 or flatter, The high strength values allow 2:1 (horizontal to vertical) cut and fill slopes up to 40 feet without gross or surficial instability. Selection of Shear Strenqth Parameters The following shear strength parameter utilized for our slope stability analysis was determined by our laboratory test results as presented below: Material (Cut or Fill) Friction Angle (Deqree) Cohesion Ib/ft2 Anticipated On-site Fill 27,0 350 We have utilized values of 27.0 degrees and 350 Ib/ft2 for bedrock cut slopes although it represents a conservative number, determined from a remolded saturated sample. Bedrock is expected to be 20% + stronger (Coduto, 1989). Even more critical to overall cut slope performance is the orientation of joints and fractures and bedding. All measured vague poorly-defined bedding was at a low angle, No evidence of slope instability exists on the site and adjoining areas, The bedrock and low angle into slope bedding orientation make all the natural slopes stable. Drainage and terracing should be in accordance with Uniform Building Code Appendix Chapter 33 requirements. At no time should water be diverted onto the slope face in an uncontrolled and erosive fashion. Rapid erosion and rutting of the fill slopes could occur, and they should be 'planted with drought resistant landscaping as soon as possible. \~ . I I I I I I I I I I I I I I I I I I I 21315-01 Page 11 16.0 GENERAL SITE GRADING 16.1 Clearinq and Grubbinq Any heavy brush and grasses or remaining trees that exist at the time of grading should be stripped from any areas to receive fill and removed off-site or stockpiled in landscape areas. 16.2 Preparation of Buildinq Pad Areas The proposed building pad is underlain by a 2.5-3.0 feet of loose soil/colluvium that should be removed. The pad is shown in transition from cut to fill, and the cut areas should over excavated to a depth of 3 feet to a distance of 5 feet outside building foundation lines to a remove the transition. 16.3 Preparation of Surface to Receive Compacted Fill All sufficiently dense (90 percent relative compaction) surfaces which are to receive compacted fill should be scarified to a depth of 6 inches, brought to near optimum moisture content and compacted to 90 percent relative compaction. other softer areas must be overexcavated to sufficiently dense material and recompacted, " 16.4 Placement of Compacted Fill Compacted fill is defined as'ttiat material which will be replaced in the areas of removal due to root removal, the placement of footings and paving, and also wherever their grade is to be raised. All fill should be co~pacted tol a minimum of 90 percent based upon the maximum density obtained in accordance with ASTM D 1557-00 procedure. The area to be filled will be prepared in accordance with the preceding section. Fills placed on natural slopes 'of 5:1 (horizontal to vertical) or steeper will require a key a~dbenching as shown in Appendix C. 16.5 Pre-Job Conference Prior to the commencement of grading, a pre-job conference should , be held with representatives of the owner, developer, contractor, architect and/or engineer in attendance. The purpose of this meeting shall be to clarify any questions relating to the intent of the grading recommendations and to verify that the project specifications comply with recommendati.ons of this report, 16.6 Testinq and Inspection During grading, density testing should ,be performed by a representative of the soil engineer in:order to determine the \~ . I I II I I I I I II I I I I I I I I I I I I ... 21315-01 Page 12 degree of compaction being obtained. Where testing indicates insufficient density, additional compactive effort shall be applied with the adjustment of moisture content where necessary, until 90 percent relative co~paction is obtained, Inspection of critical grading control procedures such as keys, installation or need for subdrains, should be made by a qualified soils engineer. Import soils to be utilized for fill should have very low expansion potential equal to that of on-site native soils. 16.7 Development Impact Provided the recommendations of this report are incorporated into the design and construction of the residential project, both the proposed development and off-site areas will be safe from geotechnical hazards, including earth slippage and settlement. 17.0'GENERAL: All grading should, at a minfmum, follow the "Standard Grading and Earthwork Specifications" as outlined in Appendix C, unless otherwise modified in the text of this report, The recommendations of this report are based on the assumptions that all footings will be founded in dense,native, undisturbed soil or properly compacted fill soil. All footing excavations should be inspected prior to the placement of ,concrete in order to verify that footings are founded on satisfactory soils and are free of loose and disturbed materials and fill, All grading and fill placement should be performed under the testing and inspection of a representative of the soil engineer. The findings and recommendations of this report were prepared in accordance with contemporary engineering principles and practice, Our recommendations are based on an interpolation of soil conditions between trench locations. Should conditions be encountered during grading, that appear to be different that those indicate by this report, this office should be notified. Services FJ/WLS:ss Distribution: (3) Addressee \? ........ - - - -.\,...- - - - - - ---. '(1;"0) (0 0/ " \ ~~ 0j, /' ~I- ~ 0 .e: .....__. " ", /' 11fI:jiI1ll\'~~, , , I L__J:.. __~ ,~..(J A~:r 'dlf3-d/(j i It;tlff Z Sm ~ ' Qr/ - l.m~..? JJ1-~ ' Z-1Y<"Z.p i'I/- 'B[YQ~ ",>- :::l';UCl \\'''L~ -.n";:~ -r ~'. ... II i~~' , - - --- --- ' '0. --- -- --- "r - ~..........,~)- - - --- -- " :::;.. \1 ~ _ It"- ~ ,G);~ -- '-... " " -- ... .. ..... , -- . I L--. :;;..-- ,{\tYc,\) ... '-... 'JNI ) I) ~ \'~:'~.:;B' I~. /lffsol0V ,q cl ,l J. 'I;' r. is'~b) _ .,WIiI ']51)(3 ,,'I> \ :z. \ ~'b<olb :A. ~ ., '''';'l^!ld ;9 ;?:: .> t-' ..\: ~\ l-' :3 - - 11\- - 8J \:"1. C S~ .....,\ ", ~,~ - <. , ~N_ (O\PI) . II ~ - - ..,JU" W - .:...!.:: ..,.. - ~-_c-/' I '-4' , 191:hi/ . ~<hl~ Fift.rv,?/(lf(; 'J , - - ~u,/ ~/H ::7iV\) . I: . t<. \ - ~;X \ , ':flj'l";I.>:a, ..... > . > 7 4'>-) ~ \.. ~v ..:f1Y .,J" ,~ w V), ,.f) J+o -Q V3d t'OWllddV "3(ll(q '.l')('/fj ~). \ '0\\ '.' : k'i . I,g", =..L I SO....'Z/ =1 /Qo:.s8p. : (;J""" /" lI~MS.i>1 ~ V __'.(.,.- '7'1- -l.: _ /"l., locol) ',.. . ..,_ Il.''''} ?~6 \ . _ '~l\. .' , <00(1) , ' <;~ "'8 ~. ~ :nJYl,L\Iaj ~W1 3c:M8aWj 'J~ . (~J) ) " ... Od~ 'so "', e>- \. / ill ~'~ '. --. .~ - - . . ~ :/~ . --;1.\J~()N - \IlK ... c;O'.J'I- . ~. .~., ,~ H:JN3lJ1 AlJ01\flJOldX3 --- ~-l. NOll VN'd1dX3, "M.rn "S'l.'~ '.8 'VIIirnO, .!I 0 10lDVd lZ6 ') . \. b7.l:,~ :'7JJ 199J1-8v9 (606) 61.8l6 V::> 'VNOHO::> '3A" .L'l:ilA3S00H OZS AHdHflW 'S H~3NNIDI CIW ~~N'.ilrfJ , 0.::- "A,~j 'j;f I <t'\. - HS-SH OJI ,1: VS VINHO!II'lV::> , 'Y'Ifl::>:tl.WU .!IO .\1.1::> 3~liON VIA 0688~ 6t6E .L::>VlU 61 ~O'1 :ssallGUV aJlS l..-8Wttt (606~ :xv..! -t:167,:->>t (606) l..8St6 v::> 'IDIV'l NOANV::> S"llS 'avOH NOhNV::> aVOH'lIVH OZSIt: DNnI:iI':!INlDN':!I :rnOHS':!I)IV'l 0/;) tOOtlOEl9'cIX:iI 't>>t.t: :!I:lH DNOA N:iI.!l r;(g mlHVd:>lHd NV'ld \. 3l.~d ~o..g,IQ.\Z . I I I I I I I I I I I I I I I I I I . ---- \.m, \. 1'91'1 ZS;61 Sf'... .... MQlS~n18"', -i)'" ..... ..,"111:;......... ...>.... ~" ..,". ..(0- ..... "..... '" ~..... ~'\:::". ~'O)~ ~...~~ ~\ ". ~~ ~ ?.s. 0...;>'- ',. '). 'OJ>" O"d-~" . , ',," ", I '/ , i' . " '/' , /~' ,'....:::/ . I ~.,~ \ I . I, :\1> :;;j ~- :~ 8 .i:'-nvr'~o . /'''If:) \ - J.-(l"l~ Z"91'1/ L~61 , , H N ----. --- 1- ,0 --' ~. ~oo ~"91'1 =<:: Z~6.x~ !i~'\ -'It t!.~i " , to ""'" ~.~ ,,' "....o~ ~,~ ., ............5- "j S'kllldS I\OllU..ooo... . ...",~ I , '. I "0, I \ .... ~--,-- \\..i . " . " ~>;".~. o1o~ ~+'\ ( --- ----- ~ ..1..... ""iirWT'- l' ........ ~"91'1 ....>. l&:~61 ",.'1,6- .~ PUDI'~ DU/ID/OJ DllIDS <'. '" '" " 01 oq S3'IW Jl ~.'. I "- j 3~ld3 +O'91i'J ~niO.LSIHiO.9-6...l'Ir~.:. .L1nU ~\t I IHI ;'>-lj-&.. 966~-OQ9~ SH3J. d. 0+ (t:L61 - ~:3:'l ':ll:~ON VI" V 1 (l-;)3W3.J.. CON 'O'M :3l.'tO 10/6 ~ 3.LYld : 3>Jn91~ ..s:\ IO-c:.\<i:\Z I I I I I I I I I I I I I I I I I I I APPENDIX A \'-' ~. . I GEOTECHNICAL TRENCH LOG I Project PrOject Neme MURPHY Number 21315-01 Elevation 1089 + / - E I t' CASE 590 SUPER L BACKHOE qu pmen Trench No, T -1 I I I I I I I I I I I I I I I I I ~ c i I .l! GEOTECHNICAL DESCRIPTION - . I:: ~ L, "i - ~ - g i . t r: .! u~ =.. i 0 ii . . W.L. SHERLING ~ .u Logged c ; . . by Date 9/25/01 I:: - . . -. 0 D- o u . f: - "i :> 14.L. SHERLI NG Do E ! . to j - ~ ~ Sampled by t- . I . .. 0 .. 0 0 - MO B 14~8 4.2 ,SOIL/COLLUVIUM - Light yellow brown 10YR 6/4 sandy silt. - c~ OS U GS- L 87.2 I Soft, dry porous. Sand increases at lower contact. - c~ EI K \ Gradational lower contact. I - S04 22.6 6.1 - 93~2 j! 5- BEDROCK - PaubaFormation - Very pale brown 10YR 7/4 to r - yellow 7/6. Interbedded sandy silts and silty sands - - (40%). Very dense, sl.damp. Vague bedding nearly - - ; horizontal., Occ. thin layers of clean medium sand w/.5% - - fine gravel to l;;". I - - 10- LD. 5.3' ~ - No Water / Mottling - - - - - - - 15- ~ - - - - - - GRAPHIC LOG trend - scale: 1"" - - · Test Symbols - - - - B - SUlk Somplo - - R - Ring Semplo I I I I , I I I SC - Soncl Cone I I I I I I I I I I I I MD - Moxlmum Donllty - - - - GS - Groin Size - - SE - Soncl Equl......t - - E I - Expanolon Index (90) - Rolollve Compaction - - - - - - Ear h - - . I I , I , I I I I I I ~ .echnics I I I . I , . - ~-~ - ~~ - ~ ~ \1 - . I GEOTECHNICAL TRENCH LOG Elevation 1081 + /- CASE 580 SUPER L BACKHOE Trench No. Equipment T-2 I Project Project Name MURPHY N b 21315-01 um er I I I I I I I I I I I I I I I I I ~ " i I R GEOTECHNICAL DESCRIPTION - . 6: l~ 'i - i ~ i '" . ! ~ it! . . u.,. i W.L. SHERLING :- Cl .. . u Logged by Date 9/25/01 " ; . . 6: '0 . . -. Q. ~ Cl - U . 6: E . :l - W.L. SHERLING ! . e j - - ~ Sampled by ~ . I :l .. Cl 0 w .., 12.5 3.8 SOIl/COLLUVIUM - Pale brown 10YR 6/3 silty fine sand and - c- sandy silt (30%). Soft, dry, porous. Sandier at lower 85.5 - contact., Grad. lower contact. c- 21.8 5.7 .15:( 92.6 - 5- -5 - - - BED'DCK - P',,, F' - V"y p']' b,,," 1DY' 1/4 '0 Y']lO'~ =- ~ 1/6 "'''''dd,d ,i'dy ,f1t "d ,11 ty '"d (40%). M1 '" - , clayey sand in 5-6 foot interval 1-3" thick. Occ. - layers 1-2" thick clean to s1. silty sand w/5% fine - 10- gravel. Dense to very dense, sl. damp. -<< - - - LD. 6.8' - No Water / Mottling - - 15- ~ - - - - - - GRAPHIC LOG trend - scale: 1"" - I- * Test Symbols - I- - I- B - Bulk Sample I- R. Ring Sampla I , , I I I I . SC - Sand Cone I I I I , , I , I I I I MD - Maximum o.nllty - - - - as" Oraln SIz. - - S E" Sand Equl...... - - E I . Expaftllon Index (90l" Ralallve ~n - - - - - . - Ear h - - , I I , I I I I I , I I ~ ~echnic5 I I I I . I I , - I- ~ ~~y-,.... - I- ~--- 7 . - I- ~ \~ - ... . I I I I I I I I I I I I I I I I I I I APPENDIX B \q - I I I I I I I I I I I I I I I I I I I MAXIMUM DENSITY - OPTIMUM MOISTURE DETERMINATION The maximum density was determined in accordance with ASTM standard D1557-78. The result by full laboratory curve is Sample Location Depth (Feet) Soil Description Maximum Drv Densitv Optimum Moisture T-1 0-3 (Soil Type A) Soil light brown silty sand with 5% gravel 131. 6 10.2 SUMMARY OF EXPANSION TESTING U.B.C. METHOD 29-2 Sample Location Depth Expansion'Index Expansion Potential T-1 0-3' 12 Very Low SAND EOUIVALENT TESTING Sample Location Depth Sand Equivalent T-1 0-3' 22 ~ - I I I I I I I I I I I I I I I I I I I Project: Murphy Job Number: 21315-01 Date: Direct Shear Test Data Earg:c~hnll ~C. 9/28/01 . 5 . ./ V ./ / V --- ...- .... l- lL d I1J Ui c. S2 . . III III Gl .. ... I1J Cl c:: .;: l'Il Gl .c:: I1J o o Normal Pressure-Kips/SQ, FT. 5 Excavation Number: T-1 Depth: 0-3' Saturated Test t/J = 27.00 Degrees c = 350 P.8.F. . Actual Values - Best-Fit Line :l.\ - - V"ln':l3\1'13j.. 3..l..'2IOI'I 'VI ^ \ O-C;l'<:\Z 'N'r 10/6 8100 $11\\ i~8 - NOl.ln81~.LSla 3ZIS NI~HE> - .lH~13M A8 ~3NI.:l .IN:3~3d - 0 el ~ ~ g 113 .." g: 0 el b (J) fT1 < fT1 (J) N fT1 (J) I c (J) (J) -l )> Z o )> :u o CD <3 c;; '" o s g '" 8 '" ~ o 8 'U l> ::0 ...; (") r ITI o l> s: ITI ...; ITI :u I s: r r s: ITI ...; ITI :u lJl €.g 11381'1nN ~181HX3 -zz 0 fTl -0 --i t :I: G) ::0 Z l> 0 < fTl r 0 -\ I \ 01 ....' -- 'Tl 0 (1)0 ;"'l l>l> Z::O 0(1) fTl :or- ,-- :-r (I)'Tl l>- ZZ ofTl -- l>C , Z "'- !Il2! 5!? :I:fTl !:i 90 00 rr l>l> (1)(1) (1)(1) -- 0 r l> -< ; I I I I I I I I I I I I I I I I I I I APPENDIX C :2-3 ,,;;,;;c. I I I I I I I I I I I I I I I I I I I - STANDARD GRADING AND EARTHWORK SPECIFICA nONS These specifications present Earth Technics Inc., standard recommendations for grading and earthwork. No deviation from these specifications should be permitted ul1less specificaIly superseded in the geotechnical report{)fthe projector by written communication signed by the geotechnical consultant. 'Evaluations performed by the gyotechnical consultant during the course of grading may result in subsequent recommendations which could supersede these specifications or the recommendations of the geotechnical report, 1.0 Generai 1.1 The geotechnical consultant is the owner's or developer's representative on the project. For the pwpose of these specifications, observations by the geotechnical consultant include observations by the soils engineer, geotechnical engineer, engineering geologist, and those performed by persons employed by and responsible to the geotechnical consultant. 1.2 All clearing, site preparation, or earthwork performed on the project shall be conducted and directed by the contractor under the supervision of the geotechnical consultant. 1.3 The contractor should be responsible for the safety of the project and satisfactory completion of all grading. During grading, the contractor shall remain accessible, 1.4 Prior to the commencement of grading, the geotechnical consultant shaIl be employed for the purpose of providing field, laboratory, and office services for conformance with the recommendations of the geotechnical report and these specifications. It will be necessary that the geotechnical consultant provide adequate testing and observations so that he may determine that the work was accomplished as specified. It shall be the responsibility of the contractor to assist the geotechnical consultant and keep him apprized of work schedules and changes so that he may schedule his personnel accordingly. 1,5 It shaIl be the sole responsibility of the contractor to provide adequate equipment and methods to accomplish the work in accordance with applicable grading codes, agency ordinances"these specifications, and the 2J'\ I I I I I I I I I I I I I I I I I I I 2,0 . STANDARD GRADING AND EARTHWORK SPECIFICATIONS PAGE 2 approved grading plans. If, in the opinion of the geotechnical consultant, unsatisfactory conditions, such as questionable soil, poor moisture condition, inadequate compaction, adverse weather, etc., are resulting in a quality of work less than required in these specifications, the geotechnical "., . consultant will be empowered to reject the work an~ recommend that' ..' construction be stopped until the conditions are rectified. 1.6 It is the contractor's responsibility to provide access to the g(lotechnical consultant for testing and/or grading observation purposes. This may require the excavation of test pits and/or the relocation of grading equipment. 1.7 A final report shall be issued by the geotechnical consultant attesting to the contractor's conformance with these specifications, SITE PREPARATION 2.1 All vegetation and deleterious material shall be disposed of off-site, This removal shall be observed by the geotechnical consultant and concluded prior to fill placement. 2.2 Soil, alluvium, or bedrock materials determined by the geotechnical consultant as being unsuitable for placement in compacted fills shall be removed from the site or used in open areas as determined by the geotechnical consultant. Any material incorporated as a part of a compacted fill must be approved by the geotechnical consultant prior to fill placement. 2,3 After the ground surface to receive fill has been cleared, tit shall be scarified, disced, or bladed by the contractor until it is uniform and free from ruts, hollows, hummocks, or other uneven features which may prevent uniform compaction. ~-s I I I I I I I I I I I I I I I I I I I I - STANDARD GRADING AND EARTHWORK SPECIFICATIONS PAGE 3 The scarified ground surface shall then be brought to optimum moisture, mixed as required, and compacted as specified, If the scarified zone is greater than twelve fuches in depth, the excess shall be removed and placed in lifts not to exceed six inches or less. ' Prior to placing fill, the ground surface to receive fill shall be observed, tested, and approved by the geotechnical consultant. 2.4 Any underground structures or cavities such as cesspools, cisterns, mining shafts, tunnels, septic tanks, wells, pipe lines, or others are to be removed or treated in a manner prescribed by the geotechnical consultant. . 2.5 In cut-fill transition lots and where cut lots are partially in soil, colluvium or unweathered bedrock materials, in order to provide uniform bearing conditions, the bedrock portion of the lot extending a minimum of 5 feet outside of building lines shall be overexcavation a minimum of3 feet and replaced with compacted fill. Greater overexcavation could be required as determined by geotechnical consultant where deep fill of20+ feet transitions to bedrock over a short distance. Typical details are given on Figure D-1. 3.0 COMPACTED FILLS 3.1 Material to be placed as fill shall be free of organic matter and other deleterious substances, and shall be approved by the geotechnical consultant. Soils of poor gradation, expansion, or strength characteristics shall be placed in areas designated by geotechnical consultant or shall be mixed with other soils to serve as satisfactory fill material, as directed by the geotechnical consultant. uo I I I I I I I I I I I I I I I I II I I STANDARD GRADING AND EARTHWORK SPECIFICATIONS PAGE 4 3,2 Rock fragments less than twelve inches in diameter may be utilized in the fill, provided: 1, They are not placed in concentrated pockets, 2. There is a minimum of75% overall of fine grained material to surround the rocks, J, The distribution of rocks is supervised by the geo~echnical consultant. 3.3!Rocks greater than twelve inches in diameter shall be taken off-site, or placed in accordance with the recommendations of the geotechnical consultant in areas designated as suitable for rock disposal. (A typical detail for Rock Disposal is given in FigureD-2. 3.4 Material that is spongy, subject to decay, or otherwise considered unsuitable shall not be used in the compacted fill. 3.5 Representative samples of materials to be utilized as compacted fill shall be analyzed by the laboratory of the geotechnical consultant to detennine their physical properties. If any material other than that previously tested is encountered during grading, the appropriate analysis of the is material shall be conducted by the geotechnical consultant as soon as possible, 3.6 Material used in the compacting process shall be evenly spread, watered, processed, and compacted in thin lifts not to exceed six inches in thickness to obtain a unifonnly dense layer. The fill shall be placed and compacted on a horizontal plane, unless otherwise approved by the geotechnical consultant. 3.7 If the moisture content or relative compaction varies from that required by the geotechnical consultant, the contractor shall rework the fill until it is approved by the geotechnical consultant. 3.8 Each layer shall be compacted to 90 percent of the maximum density in compliance with the testing method specified by the controlling governmental agency or ASTM 1557-70, whichever applies. '2.1 - I I I I I I I I I I I I I I I I I I I STANDARD GRADING AND EARTHWORK SPECIFICA nONS PAGE 5 If compaction to a lesser percentage is authorized by the controlling governmental agency because of a specific land use of expansive soil condition, the area to receive fill compacted to less than 90 percent shall either be delineated on the grading plan or appropriate reference made to the area in the geotechnical report, 3,9 All fills shall be keyed and benched through all topsoil, colluvium alluvium, or creep material, into sound bedrock or finn material where the slope receiving till exceeds a ratio of five horizontal to one veI1icaJ, in . accordance with the recommendations of the geotechnical consultant. 3.10 The key for side hill fills shall be a minimum width of 15 feet within bedrock or firm materials, unless othelWise specified in the geotechnical report, ( See detail on Figure D-3. ) 3. I I Subdrainage devices shall be constructed in compliance with the ordinances of the controlling governmental agency, or with the recommendations of the geotechnical consultant. (Typical Canyon Subdrain details are given in Figure D-4, ) 3.12 The contractor will be required to obtain a minimum relative compaction of 90 percent out to the finish slope face offill slopes, buttresses, and stabilization fills. This may be achieved by either over building the slope and cutting back to the compacted core, or by direct compaction of the slope face with suitable equipment, or by any other procedure which produces the required compaction approved by the geotechnical consultant. 3,13 All fill slopes should be planted or protected from erosion by other methods specified n the geotechnical report. 3.14 Fill-over-cut slopes shall be properly keyed through topsoil, colluvium or creep material into rock or firm materials, and the transition shall be stripped of all soil prior to placing fill. (See detail on Figure D-3. ) Zf> - I I I I I I I I I I I I I I I I I I I STANDARD GRADING AND EARTHWORK SPECIFICATIONS PAGE 6 4.0 CUT SLOPES 4.1 , The geotechnical consultant shall inspect all cut slopes at vertical intervals not exceeding ten feet. 4.2 If any conditions not ?.nticipated in the geotechnical report such as perched water; seepage, lenticular or confined strata of potentially adverse nature, unfavorably inclined bedding, joints or fault planes encountered during grading, these conditions shall be analyzed by the geotechnical consult;mt, and recommendations shall be made to mitigate these problems. (Typical . details for stabilization of a cut slope are given in Figures 0-3a and 0-5, ) 4.3 Cut slopes that face in the same direction as the prevailing drainage shall be protected from slope wash by a non-erodible interceptor swale placed at the top of the slope. 4.4 Unless otheIWise specified in the geotechnical report, no cut slopes shall be excavated higher or steeper than that allowed by the ordinances of controlling governmental agencies, 4.5 Drainage terraces shall be constructed in compliance with the ordinances of controlling governmental agencies, or with the recommendations of the . geotechnical consultant. 5,0 TRENCH BACKFILLS 5, I Trench excavations for utility pipes shall be backfilled under the supervision of the geotechnical consultant. 5.2 After the utility pipe has been laid, the space under and around the pipe shall be backfilled with clean sand or approved granular soil to a depth of at least one foot over the top of the pipe. The sand backfill shall be uniformly jetted into place before the controlled backfill is placed over the sand. 5.3 The on-site materials, or other soils approved by the geotechnical consultant shall be watered and mixed as necessary prior to placement in lifts over the sand backfill. 2.'\ - I I I I I I I I I I I I I I I I I I I STANDARD GRADING AND EARTHWORK SPECIFICATIONS PAGE 7 5.4 . The controlled backfill shall be compacted to at least90 percent of the maxiinum laboratory density as determined by the ASTI D 1557-70 or the controlling governmental agencies. 5,5' Field density tests and inspection of the backfill procedures shall be made by the geotechnical consultant during backfilling to see that proper moisture content and uniform compaction is being maintained" The contractor shall provide test holes and exploratory pits as required by the geotechnical consultarit to enable sampling and testing. 6,0 GRADING CONTROL 6.1 Inspection of the fill placement shall be provided by the geotechnical consultant during the progress of grading. 6,2 In general, density tests should be made at intervals not exceeding two feet. of fill height or every 500 cubic yards of fill placed. This criteria will vary depending on soil conditions and the size of the job. In any evedt, an adequate number of field density tests shall be made to verifY that the required compaction is being achieved, 6,3 Density tests should also be made on the surface material to receive fill as required by the geotechnical consultant. 6.4 All clean out, processed ground to receive fill, key excavations, subdrains, and rock disposals should be inspected and approved by the geotechnical consultant prior to placing any fill. It shall be the contractor's responsibility to notifY the geotechnical consultant 'when such areas are ready for inspection. ~ I I I II I I I I I I I I I I I I I I I STANDARD GRADING AND EARTHWORK SPECIFICATIONS PAGE 8 7.0 CONSTRUCTION CONSIDERATIONS 7.1 Erosion control measures, when necessllI)', shall be provided by the contractor during grading and prior to the completion and construction of permanent drainage controls. 7.2 Upon completion of grading and termination of inspections by the geotechnical consultant, no further filling or excavation, including that . . necessllI)' for footings, foundations, large tree wells, retaining walls, or other features shall be preformed without the approval of the geotechnical consultant. 7.3 Care shall be taken by the contractor during [mal grading to preserve any berms, drainage terraces, interceptor swales, or other devices of permarient nature on or adjacent to the property, ~\ - I I I I I I I I I I I I I I I I I I I TRANSITION LOT DETAILS CUT-FILL LOT NATURAL GROUND \ . --- -- - - -- -- .- --- -- u , UNWEATHERED BEDROCK OR . 1 r-- MATERIAL APPROVED BY . ~ f THE GEOTECHNICAL CO.NSULTANT CUT LOT - ..-- NATURAL GROUND ~-- --- -- -- -- . -- --- - .- -- -- -- -- - REMOVE __ --- __ _ _ -- ~UNSU1TABLE ______ _ - . 5' I, _:..- _ .MATERIAL _ MIl'!-, r; ::::-::::_=_=_~_=:_--=-_-:_-:_-_-_-::_-_:..--~--: :------T---------:::--------: :: _ __ ____."...-_,..y, V\ I^ . -COMPACTED :=-------=:-- \ ~~~~~~~~ OVEREXCAVATE AND RECOMPACT --- UNWEATHERED BEDROCK OR f r-- MATERIAL APPROVED BY . t THE GEOTECHNICAL CONSULTANT NOTE: ,?eeper ov.erexcavalion and recamoactian shaH be p~rformed If de!ermmed -0 be neces.scry by the geotec:,,,iccl consultant. 3Z- . I II I I I I I I I I I I I I I I I I I . BENCHING DETAILS '" -------------""':.....: _-_-_~_:= CaMP ACTED .------:...---. -------=-==F1LL ..:..----=------=-- ---------- ------- --------------------- -=---:==-:::=:::=:=~ ::::~:~-:-~--:=-~~ _______ __:..r__ __ ____ _________~4-------...-~...;.~... . ------------~---~ - . ---------------=-----;..::-:...-------1 'I"r^' , PROJECTED PLANE . _-_=_?=:::-::.::-z-:;::---::.,-~-- I to I maximum from roe _-=-_=__-_=_-=---;2'"'-=------=-;~~ \,A""':- . of slope to aporoved gr-ound _-_=__-_=_...:z-.E----=--=-;.=-:--=--=- \ ' , __-_=__=_-=-...:;:=----=--=--=-~ ! - - ,,,,;~ REMOVE , ___________..._ UN<:'JITAB' C __.,~_____.,....--_. _I' L.._ _,;.-..c-----....;::'::":--- .~ , . ;~_-_-_=__-_=__.__,~ - ~ MATERIAL -------.--- ~ 4 _ -_-.;::--=--=-- 4' MIN. ", --=-r--=--=---;...-~-------=- B,ENCH BENCH t -r_=_;~-=----=--------=--=- I HEIGHT -I- _:~~2% 'MTN:::---::- (typical) VARIES T ------=:;;;..:---=-- ~^~ '^V 2' MIN.\ 15' MIN. I KEY h-OWEST BENCH-, DEPTH. (KEY) F1LL SLOPE NATURAL GROUND\ I'" _-: COMPACTED :::::-:-:;::::- FILL OVER CUT SLOPE ----------:F1LL.:---...;:-~----- -' __-:=E:=:~=~~~~;t~ _-=-~=-==: =-=---:-=:.?i 4 :~/;:- -----------~-~ I _-:.;::-~_-_-_--_=_..-----2 .... REMOVE. N -- ~, - --?:::""'_-_-_-_--..c:; ,~" -\ UNSUIT ABLE A I uKAL :z~--=-_-_-..::;:.7_~-_-:i GROUND ----- - .' J MATC~IAL '\ __ __ __ ~ -:_--f!J;-~Jf.j '8"" L~~~~~; I ~~1~~ _ ~ _ __ ~2%MIN_'::::-' \. (;ypiCGI~ \j~?IES _ _ _ _ \ ___ ___ "A..,'V!"" 1 .'11'....... . ,>\--- -- ~I 5' MIN.--J ___ .- --- . I LOW:=ST BENCH \ --- CUT FACE To be constructed prior to fill plccement .- -- "",""i'< NOTES: LOWEST BENCH: Depth and width subject to fidd change based Co" cOClsultant's inspecliOCl. S~!:'QRAl~JAGE:. e",;: c~,:.:":; r.1<:y bo:: ro::quired at tho:: __..~~~; th.- ........r"ltt"'cnnirnt rnn~\1ttnn~_ 3>3> I I FOUNDATION AND SLAB RECOMMENDATIONS FOR EXPANSIVE SOILS (ONE AND TWO-STORY RESIDENTIAL BUILDINGS) I EXPANSION INOEX 0-20 VERY lOW EXPANSION EXPANSION INDEX 21 -: 60 LOW EXPANSION EXPANSION INOEX 51 - gO MEDIUM .EXPAHSION EXPANSION INDEX ;1 - 130 HIQH EXPANSION I 1-IIOftY fOOTtHOa ALL FOOTING' 12 IHCHU DEEr. ,00ItHO. CONTtHUOUI. NO ITlll IlfOUtftlD FOil UPAN:S10fC fOften. All fOOTlNOI 12 IHeHEI 0[('. rCOTIMOI . . COtCTltfUOUI. '-NO." ."', TO' AND lono... UUftlOft fOOTINOI " IHCHE_ DEE,.. IMTEft'Oft fOOTINOI 12 IHCHE. DEE'. '-NO. .. U." TO" AND lonow. IEXTEftlOft FOOTINGS 14 IHCttt:1 our. II(TE'UOft fOOTlNOS .12 IMeHU DEEI'. '-NO. I IAIl 10" AND .OTTO.... I ,-nor'" f0011N0S All ,.OOTINOS " ,"eHU our. FOOTINGS COKTINUOUS. NO nUL ftEQUlftEO fOft UrANSlON FOften. All fOOTlNOS 11 tHeHEI OU:,. fOOTINOI CONT,"UOUS. '-NO. .. u..I'I Tal' AND .OTTO.... ALL fOOTlNOS .. 'NCHES OEEI". fOOTINO' CONTINUOU'. ,-HO. .. 'A'" Tal" AND .OTTO.... EXTEIlIOIl fOOTlNOS I. ,HCMEI OUI". 'NTUIO" FOOTINOS " ,HCHEI DEE!". I-HO. . 'AIl TDI" AHD lonow. I OA"AOE 000" O"ADE .EA... HOT RlQOlMO. t2 INCHES DEEI". '-HO. ~4 'A" Tal" AHD .OTTO.... ,- " 'HCHES DEE'. '-HO. . 'AR TO' AHD 'OTTOW. U INt;HU OH'. '-HO. 15 UfI. TO'.AHD 10TTOw. I LlVIHO A~.A FLOOR aLAIS ~ 112 INCHES THICI(. HO "UH S 112 INCHES THtCK. a 112 IHCNEI THICI(. . IHCHU THICK. . X I-III e,., fl.EOUIRED fOf! U'AH3lOH I I '-'0110 WlfIlE WEIH AT . X 1-'01t0 WIRE IoIEIH AT WIRe WEIN AT 1,IID-HEIOHT. fO"CES. NO USE RlOVtf{ED. IoUD-HEIOHT.2 IHCHES WIO-HEIOt:1. . INCHES NO. a DOWELLS f"OW. fOOTlNO . loll\.. VlaOUIfEN 1oI0lSTUftt GII."VEl 011. 'ANO ."SE. . OIl."VEL 01, 'AHD "ASE. . TO SlAl AT S' IHCHU ON 'AIIIAIE" I"LUS , IHCH 'AND. loll\.. Y1SQUf;EN 1010" TUII.E lollL VlaOUEEN lolOISTURE CENUII.. . INCHEI GAAVEl 0" ."II.'UfA )olUI , IHCH IANO. 'A"fl.IE" PLUS' INCH lAND. 11..1'40 lASE. I IolIL VISOVEEH lolOISTUftE SARAIE" 'lUS , IHCH lAND. GA"AGE flOOR alAI a S "2 INCHEI THICK. NO WEIH S 112 IHCHES THICK. a 112 INCHES THICK. <I INCHES THICK. I X I -III REOutAEO fOA U""HSlOH . X 1-'0110 WlftE IoIESH 011. . X '-'0/'0 WIRE welH OA WIRE WESH OR QUA-II.TEA fOftCU. NO S"SE AEOUlAEO. OUAkTE'" alA. I. ISOLATE QUARTER aU.as. ISOLA.TE aLAIS. ISOLATE FROlol ITEW NO IoCOISTURE BURIE" FROW ITEW WALL FOOTINOl. FRO,", STEIoC WALL FOOTlNOS. WALL FOOTINOS. .. INCHES "EOUIREO. 2 INCHES "OCI(. Oll,AVEl OR ." INCHES. ROCK. ORAVEl OR ROCI(. ORAVEL 0" S"'ND ."'SE. S"ND ."se. NO WOISTVRE S"'ND ....SE. HO 1ol0"TURE NO 1ol0lSTUAE ''''RRIEII; I...RRIER REQUIRED. ....RRIER REQUIRED. REOUlREO. "u:-aOU:'INQ or llVINQ NOT REOUlRED. 1ol0lSTEM SO"'K 10 U IHCHES DEPTH aOAK TO 11 INCHES OE"TH SO"'K TO 2. IHCHES OEPTH TO AflE'" AHO QAII.AQE aLAI 'RIOR TO "OURIHO TO .... ABOVE OPTIMUM TO 6"1. A'OVE OPTll,IUl,I 6" "'60VE OPTIl,IlJU ..OISTURE IOlll COHCRETE. 1ol0lSTURE COHTENT. ,",OISTURE CONTENT. CONTENT. I I I I I NOTES: 1) "'lL OE'THS "'RE REl...TlVe'TO SLAI 3UBGR"'OE. 21 SPECI"'l oeSION IS REOUIREO FOR VERY HIGHLY [X..",HSIVE SOilS. I FOUNDATION AND SLAB DETAIL (NOT TO SCALE) I DOWEl 3tA,e SUBGAA,OE\ ..,:::O[ ";:S.._\ (WHEN REOUIREOl,. \ St"', / o~: . ...::.,..:...:.....:..,."...,- ~....:;..) -:-:::'..-.:).n.,,'-!'b j-S"N'Jl"YEOI / /.V'",OUEEI'( / /. rQRA,VEl OR s"..a '''Sl I.....'.. ;::0..::,,'01(0) / I /.,"...., : . . .~'- '-8. g. '":.:',.v...... f\~"':'. ,01'."'\'." ;'\" ,"0 'r",,'. .'-. ..~.:..~'. ~~ 0" '. I DEPTH or EXTERIOR I " I "EINfOIllCINO 1"'1'1 DEPTH OF (WH(M REOUIAEOI Il-ITERIOA OEPTH Of FOOTlNQ PRE-SO"I((O I ' lOlL ~ l_____.NH.,=:~:..._____ I FOUNDATION AND SLAB RECOMMENDATIONS I JOB NO.: 'DATE: FIGURE NO.: - EARTH TECHNICS I I I I I I I I ! I I I I I I I I I I I I APPENDIX D , ' "7;>-5" - I II I I I I I I I SURFICIAL SLOPE STABILITY S,F. = H (/fa) cos2o<tan ~ + c lis H Sin C<<. coso<. Sino) ~ 044G. Co-(.1o( ~ 0.89 S 14n91 ~ 0.(;10 zone of saturation o == 2b.S I I I I S.F. = I I I I I H = Depth of saturation zone ~a = Bouyant weight of soil ! - -I 25's = Total wet weight of soil = ~ = Angle of !internal friction = C = Cohesion = H' S.L 2- '3.85 - <'\ '2. I') -, - := 1(::,,0 172,4 21,D :JS" = p-s "- H(lO,ol(o.801)(O,C;lo)+ 350 It (1:>,24)( b, 44q (0,l\~0) H (28~) +%0 t:=s ~ H (52.. II) ) Project No.: Calc. by: Chk. by: Date: 2-\'7;1'5-0 I ww F-J 9/"-'7/0 I ~ I I I I I I I I I I I I I I I I I I I APPENDIX E 3>1 . I I I I I I I I I I I I I I I I I I I PUBLISHED REFERENCES Blake, T.F" 1998, Computer Services Software, A Computer Program for the Probabilistic Evaluation Horizontal Acceleration from California Faults, FRISKSP, July 1998 Blake, T,F., 1998, comnputer Services Software, A Computer Program to Determine Historical Seismicity from Digitized California Faults, EQSEARCH, July 1995 Bolt, B.A., 1973, Duration of Strong Ground Motion: Proc, Fifth World Conference on Earthquake Engineering, Paper No. 2927 Clark, M,W., Harms, K., et al., 1984, Preliminary Slip-Rate and Map of Late-Quaternary Faults of California, U,S.G.S. Open-File Report 84-106, 12 p. Coduto, D.P., 1987, Down to Earth Soils Engineering, Volume 4, Slope Stability, Cal. Poly University, Pomona , I DWR, 1971 Water Wells and Springs in the Western Part of the Upper Santa Margarita River Watershed, 'Riverside and San Diego Counties, California", Bull, No. 91-20; 377 Hart, E.W., 1998, Fault Rupture Hazard ,Zones in California, C,D.M.G. Special Report No, 42, 25p Hays, W,W., 1980, Procedures for Estimating Earthquake Ground Motions, U.S.G,S. Professional Paper 1114, 77p Kennedy, M.P., 1977, Recency and Character of Faulting Along the Elsinore Fault Zone in Southern Riverside County, California, C.D.M.G. Spec, Report 131, 12 pages Peterson,M.P., Bryant, W. A., Cramer, C.H., Reichle, M.S., 1996, Probabilistic seismic Hazard Assessment for the State of California, C.D.M.G. Open-File Rept. 96-08 Ploessel, R.J., and Sloson, J.E., 1974, "Repeatable High Ground Accelerations from Earthquake", in California Geology, Sept, 1974 Seed, H,B" and Idriss, I.M., 1982, Ground Motion and Soil Liquefaction During Earthquakes, E.E.R.I. Nomograph, 134p, Berkley Press Weber, F.H. Jr" 1977, Seismic Hazards ,Related to Geologic Factors, Elsinore an d Chino Fault Zones, Northwestern Riverside County, California, CDMG Open-File Report 77-5 LA, 96 pages ~ ...