HomeMy WebLinkAboutTract Map 9833-3 Lot 12 Compaction Results Rough Grading I ~ . . ... 11. l:i I · ......, 'lI':" .. . .... EN I Corporation -Soil Enllineering and Consulting Services. EngineeringGeology- CompaclionTesting -lnspections-ConslruclionMaterialsTesting-laboratoryTesting.Percolalion Tesling -GeologyeWaterResoUlceSludies . Phase I & II Environmental Site Assessments ENVIRONMENTAL & GEOTECHNICAL ENGINEERING NETWORK I I GEOTECHNICAL REPORT AND COMPACTION TEST RESULTS ROUGH GRADING OPERATIONS Vasant Residence Lot 12 of Tract 9833-3, 43775 Calle De Velardo City of T emecula, County of Riverside, California LD 99-112GR Project Number: T1850-C I I November 4, 1999 I I I I I I I Prepared for: I I Krishna Vasant clo Peter-Built Homes " 30647 Calle Pin a Colada Temecula, California 92591 , , " ,- - - \ .- ~ "' .- , ' I' .- / " ,,1_' , " \ - - - \...- ,,- ,'" - \ / \- " -- , / / '- ?/ , /' ,- -- \ ,,- ,'" - . F __ I ,. / " -- , , ,.. F I _" _ ~ - \... -. ' / " ,,/ -' '/ " ,- -- \,,"- " -" ~~::.'- _/_,-=:. " __ I I I I I , I I I I I I I I I I I I I I I Krishna Vasant clo Peter-Built Homes Project Number. T1850-C TABLE OF CONTENTS SECTION NUMBER AND TITLE PAGE 1.0 SITE/PROJECT DESCRIPTION AND LOCATION ......................................................................1 1.1 PROJECT LOCATION ............. ....... ..... ............ ................................... ..... ................ ........ .....1 1.2 PROJECT DESCRIPTION ........... .... .......... ................................ ... ... ..... .................... .......... ...1 1.3 SITE DESCRIPTION ... .... ............ .... ...... ... ... .... ... ... .................. .... ........ ................ .... ........ .....2 2.0 SCOPE OF WORK ..............................................................................................................2 2.1 TIME OF GRADING .......... .......... .... ...... .......... ...... ........ .......... ...... ...... .... ........ .... ............ .....2 2.1 CONTRACTOR AND EQUIPMENT.. ..... ..... ... .......... ... ... .......... ..... ... ........ ........ ........ .... ......... ....2 2.2 GRADING OPERATIONS......................................................................................................2 3.0 TESTING ...........................................................................................................................3 3.1 FIELD TESTING PROCEDURES .. ..... ........ ... ............. .... .... ....... ... ...... .............. ...... .... ........ .....3 3.1.1 LABORATORY TESTING.....................,.........................................................3 3.1.2 MOISTURE-DENSITY RELATIONSHIP TEST ....................................................3 3.2 EXPANSION INDEX TEST ....... .... .... ..... ................... .... .... .......... ...... ............ ..... ... .... ........ .....3 4.0 EARTH MATERIALS ...........................................................................................................3 5.0 CONCLUSIONS AND RECOMMENDATIONS ............................................................................3 5.1 GENERAL ......... .... ..... ..... .............. .......... .... ... ... ... ............... ... ... ........ ...... ... ... .......... ...... ...4 6.0 CLOSURE ..................,......................................................................................................4 ApPENDIX TEST RESULTS DRAWINGS EnGEN Corporation 1- :~EN I I I I I I I I I I I I I I I; : - i~r.1 , Corporation . Soil Ellgineeringand ConsultillgSePliceS. Engil1€eringGeology. CompaclionTestlng -Inspections- ConslruclionMaterialsTesting-laboratoryTesling. PercolalionTesling . Geology. Water Resource Studies . Phase I & II Environmental Site Assessments ENVIRONMENTAL & GEOTECHNICAL ENGINEERING NETWORK November 4, 1999 Krishna Vasant c/o Peter-Built Homes 30647 Calle Pina Colada Temecula, California 92591 (909) 676-2056 Attention: Mr. Peter Pacitto Regarding: GEOTECHNICAL REPORT AND COMPACTION TEST RESULTS ROUGH GRADING OPERATIONS Vasant Residence Lot 12 of Tract 9833-3, 43775 Calle De Velardo City of Temecula, County of Riverside, California LD 99-112GR Project Number: T1850-C References: EnGEN Corporation, Limited Geotechnical Study, Proposed Single Family Residence, Lot 12 of Tract 9833-3, 43775 Calle de Velardo, City of Temecula, County of Riverside, California, Project Number: T1850-LGS, report dated September 10, 1999. Manning Engineering, Grading Plan, Lot 12 of Tract 9833-3, Assessors Parcel Number: 945-150-012, plans undated. 1. 2. Dear Mr. Pacitto: According to your request and signed authorization, EnGEN Corporation has performed field observations, sampling, and in-place density testing at the above referenced site. Submitted, herein, are the test results and the supporting field and laboratory data. 1.0 SITE/PROJECT DESCRIPTION AND LOCATION 1.1 PROJECT LOCATION The subject site consists of 3.0 acres, located on the west side of Calle de Velardo in the City of Temecula, County of Riverside, California. 1.2 PROJECT DESCRIPTION Prior to gradingoperation~topographY and surface conditions of the site were moderately sloping with surface drainage to the northwest at a gradient of less than 15 percent. " ~ / -' '/ ..... /" I ... _ '/ ,r \ _ _ _ \ __ " ~ I " " , " - , - - , , / . - / / "" -- \,,"" / ,- " ' I _" _ \.r"" , "/ '- ," I "' \ _ _ _ \ ,,- ,,- < / " "" - I " ,_ _ _ \..- , " , , ~ / .... /, / I" ,_ __ \ , ' - , ' ' I I I I I I I I I I I I I I I I I I I 1.3 2.0 2.1 2.1 2.2 Krishna Vasant clo Peter-Built Homes Project Number. T1850-C November 1999 Page 2 SITE DESCRIPTION It is understood that the subject site is to be developed with a single family residence with slab-on-grade concrete floors. SCOPE OF WORK TIME OF GRADING This report represents geotechnical observations and testing during the construction operations from October 1, 1999 through October 6, 1999. CONTRACTOR AND EQUIPMENT The grading operations were performed by "One Tractor Doze It AU" through the use of one (1) J.D. 850C track-mounted dozer. GRADING OPERATIONS Grading within the subject site consisted of a cut/fill operation. . Grasses and weeds were removed prior to fill placement. Fill material was generated from the eastern portions of the site, and used to bring the western and northeastern portions of the site to finish grade elevation. Removal of alluvium, slopewash, etc., was performed to a depth of 3.0-feet below original elevation. Over-excavated earth material was stockpiled and later used as fill. Bottoms were observed, probed and found to be into competent bedrock by a representative of this firm. Keying and benching into competent bedrock was observed during the grading operations. Over-excavation was performed in the cut portion of the building pad to a depth of 3.0-feet below finish grade elevation and to a distance of 5.D-feet outside the proposed structure. The exposed bottoms were scarified and moisture conditioned to a depth of 12-inches then compacted to 90 percent. Fill was placed in lens thicknesses of 4 to 6-inches, thoroughly moisture conditioned to near optimum moisture content, then compacted to a minimum of 90 percent relative compaction. Moisture conditioning of the on-site soils was performed during the compaction process, through the use of a water hose attached to a fire hydrant. The pad area was generally graded to the elevations noted on the Grading Plan. However, the actual pad location, dimensions, elevations, slope locations and inclinations, etc. were surveyed and staked by others and should be verified by the Project Civil Engineer. EnGEN Corporation ~ I I I I I I I I I I I I I I I I I I I Krishna Vasant c/o Peter-Built Homes Project Number. T1850-C November 1999 Page 3 3.0 TESTING 3.1 FIELD TESTING PROCEDURES Field in-place density and moisture content testing were performed in general accordance with ASTM-D-2922-81 (90) and ASTM-D-3017-88 procedures for determining in-place density and moisture content, respectively, using nuclear gauge equipment. Relative compaction test results were within the 90 percent required for all material placed and compacted. Test results are presented in the Appendix of this report. Fill depths and test locations (by station numbers when applicable) were determined from review of the referenced grading plans. 3.1.1 LABORATORY TESTING The following laboratory tests were performed as part of our services during the grading of the subject site. The test results are presented in the Appendix of this report. 3.1.2 MOISTURE-DENSITY RELATIONSHIP TEST Maximum dry density - optimum moisture content relationship tests were conducted on samples of the materials used as fill. The tests were performed in general accordance with ASTM D1557-91 procedures. The test results are presented in the Appendix (Summary of Optimum Moisture Content I Maximum Dry Density Relationship Test Results). 3.2 EXPANSION INDEX TEST A soil sample was obtained for expansion potential testing from the building pad area upon completion of rough grading of the subject site. The expansion test procedure utilized was the Uniform Building Code Test Designation 18-2. The material tested consisted of silty sand, which has an Expansion Index of O. This soil is classified as having a very low expansion potential. The results are presented in the Summary of Expansion Index Results in the Appendix of this report. 4.0 EARTH MATERIALS The natural earth materials encountered on-site, generally consisted of silty sand, brown. 5.0 CONCLUSIONS AND RECOMMENDATIONS No conditions were encountered which would cause a change in the previously provided design and construction recommendations. As a result, design and construction should adhere to the recommendations provided in the Referenced No. 1 Limited Geotechnical Study. ..... EnGEN Corporation ? I I I I I I I I I I I I I II I I I I I Krishna Vasant c/o Peter-Built Homes Project Number: T1850-C November 1999 Page 4 5.1 GENERAL Based on the observations and tests performed during grading, the subject site in the areas noted has been completed in accordance with the the Referenced No. 1 Geotechnical report, or as amended in the field based on conditions encountered, the project plans, and the Grading Code of the City of Temecula. The graded site in the areas noted as graded is determined to be adequate for the support of a typical residential development. Any subsequent grading for development of the subject property should be performed under engineering observation and testing performed by EnGEN Corporation. Subsequent grading includes, but is not limited to, any additional fill placement and excavation of temporary and permanent cut and fill slopes. In addition, EnGEN Corporation should observe all foundation excavations. Observations should be made prior to installation of concrete forms and/or reinforcing steel so as to verify andlor modify, if necessary, the conclusions and recommendations in this report. Observations of overexcavation cuts, fill placement, finish grading, utility or other trench backfill, pavement subgrade and base course, retaining wall backfill, slab presaturation, or other earth work completed for the development of subject site should be performed by EnGEN Corporation. If any of the observations and testing to verify site geotechnical conditions are not performed by EnGEN Corporation, liability for the safety and performance of the development is limited to the actual portions of the project observed and/or tested by EnGEN Corporation. 6.0 CLOSURE This report has ,been prepared for use by the parties or project named or described above. It mayor may not contain sufficient information for other parties or purposes. The findings and recommendations expressed in this report are based on field and laboratory testing performed during the rough grading operation and on generally accepted engineering practices and principles. No further warranties are implied or expressed beyond the direct representations of this report. EnGEN Corporation ~ I I I I I I I I I I I I I I I I I I I Krishna Vasant c/o Peter-Built Homes Project Number. T1850-C November 1999 Page 5 Thank you for the opportunity to provide these services. If you should have any questions regarding this report, please do not hesitate to contact this office at your convenience. Respectfully submitted, EnGEN Corporation (JIM_ ~ ALA- '--{f::::n D. Gardn;;7~ Field Operations Manager JDG/OB:ch Distribution: (4) Addressee FILE: EnGEN/Reporting/CfT1850C Vasant Residence, care of Peter-Built Homes EnGEN Corporation 1 I I I I APPENDIX FIELD TEST RESULTS (SUMMARY OF FIELD IN-PLACE DENSITY TEST RESULTS) (NUCLEAR GAUGE TEST METHOD) Krishna Vasant c/o Peter-Built Homes Project Number. T1850-C Appendix Page 1 Iil'est No. Test Date (1999) il'est Locations Depth Elev. (Fil') Max Density (PCF) Moisture Content (%) Dry Density (PCF) Soil il'ype 1 1 10-1 West Facing Fill 130' A1 123.8 14.4 105.9 2 10-1 Retest of #1 130' A1 123.8 12.2 100.9 I~ 10-1 Retest of #2 130' A1 123.8 11.6 109.9 10-1 Retest of #3 130' A1 123.8 12.8 114.2 I~ 10-1 Slope Adjacent Pad 132' A1 123.8 12.2 116.5 10-1 Slope Adjacent Pad 132' A1 123.8 12.8 114.7 7 10-1 Slope Adjacent Pad 134' A1 123.8 11.9 114.3 I: 10-4 West Slope Fill Area 136' A1 123.8 6.0 113.2 10-4 West Slope Fill Area 137' A1 123.8 7.1 111.8 ! 10 10-4 West Slope Fill Area 139' A1 123.8 9.0 111.3 111 10-6 West Slope Fill Area 141' A1 123.8 10.0 111.7 12 10-6 West Slope Fill Area 143' A1 123.8 10.6 116.8 113 10-6 West Slope Fill Area 145' A1 123.8 11.1 117.0 14 10-6 Building Area F.G. A1 123.8 11.0 111.7 15 10-6 Building Area 145.5' A1 123.8 6.9 114.3 116 10-6 Building Area 146.5' A1 123.8 10.3 111.4 I (F.G.) Indicates Finish Grade. I 1 I I I I Relative Compaction (%) Required Compaction (%) 85.7 90 81.7 90 88.9 90 92.6 90 94.3 90 92.8 90 92.5 90 91.4 90 90.3 90 90.0 90 90.2 90 94.4 90 94.5 90 90.2 90 92.3 90 90.0 90 EnGEN Corporation ~ I I I I I i I I I I I I I I II I I I I I Krishna Vasant c/o Peter-Built Homes Project Number. T1850-C Appendix Page 2 SUMMARY OF OPTIMUM MOISTURE CON1TENT I MAXIMUM DRY DENSITY RELATIONSHIP TEST RESULTS ASTM 01557-91 Optimum Soil Maximum Moisture Soil Description Dry Density Content Type (USCS Symbol) (PCF) (%) A1 Silty Fine Sand, Brown (SM) 123.8 10.0 SUMMARY OF ExPANSION INDEX TEST RESULTS UBe 18-2 Soil Type Moisture Condition Before Test (%) Expansion Index Moisture Condition After Test (%) Depth (FT) Dry Density (PCF) 111.4 A1 1.5 8.1 15.1 o EnGEN Corporation q I Krishna Vasant c/o Peter-Built Homes Project Number. T1850-C I Appendix Page 3 , I I DRAWINGS I I I I I I I I I I I I I I EnGEN Corporation \0 I