Loading...
HomeMy WebLinkAboutTract Map 3646 Lot 9 Grading & Compaction Control I I I I I I I I I I I I I I II I I I I GRADING AND COMPACTION CONTROL LOT 9, TRACT 3646 LOS RANCHITOS AREA CITY OF TEMECULA, CALIFORNIA Project No. 8S2WRC-56 May 9, 1991 ~ Prepared for: Mr. Albert Mondone 3366 Calle La Veta San Clemente, Cal1forn1a 92672 Prepared by: CALIFORNIA GEO TEK, INCORPORATED 42030 Aven1da Alvarado, Su1te A Rancho Cal1forn1a, Cal1forn1a 92390 (714) 676-2782 \ I I I I I I I I I I I I I I I I I I I CALIFORNIA GEO TEK, INC. ~..' 42030 Avenida Alvarado, Suite A . Temecula, CA 92390 . (714) 676-2782 May 9, 1991 Project No. 8S2WRC-56 INTRODUCTION The grading permit for this parcel was originally issued by the County of Riverside. Just prior to its expiration, it was renewed by the newly formed City of Temecula. The compacted fill on the subject lot has been tested for compliance with applicable City specifications. The work was authorized by Mr. Mondone and included: (1) inspecting the clearing and stripping, (2) inspecting the bottom of the overexcavation, (3) approving the import materials, (4) inspecting and testing the compacted fill, (5) testing the recompaction of the overexcavation materials, (6) performing a laboratory Expansion Index test on representative materials, (7) performing a laboratory Maximum Density test on representative materials, (8) preparing this report presenting the findings, conclusions and recommendations. Plate 1 - Test Location Plan (40-scale) Appendix A - Laboratory Test Data Sheets 1-- I I I I I I I I I I I I I I I I I I I 8S2WRC-56 Page 2 FINDINGS Prooosed Develooment A single family residence is proposed for construction. One 18 inch diameter CMP (corrugated metal pipe) is proposed to be installed under the driveway leading from East Vallejo Avenue. Document Review The Grading Plan, prepared by Civil Trans, Inc. (Diamond Bar) and surveyed by Elkins & Associates (Chino), indicated the maximum height of the 5:1 fill slope is approximately 4 feet. The pad is located in the northeast quadrant of the lot, and is shaped roughly rectangular with dimensions of approximately 130 feet by 110 feet. The maximum gradient of the driveway is 4 percent. Twelve inch diameter CMP's are proposed to be placed approximately 1.0 feet under the driveways east and north of the residence to allow adequate drainage of the watercourses. The estimated earthwork quantities are 45 cubic yards of cut and 1969 cubic yards of fill with the difference being imported. Site Conditions The parcel is located at the southwest corner of Ynez Road and East Vallejo Avenue. The general terrain of the area is flat, and the site is covered with annual grasses. The pad is constructed in the northeast portion of the lot. The area to the south of the pad is sloping to the south at an approximate gradient of one percent. A 24 inch CMP crosses Ynez Road from northeast to southwest, discharging runoff at the northeast corner of the subject lot. Earthwork Contractor The earthwork was performed by One Dozer Doze It All (Lake Elsinore) from April 22, 1991 through 30, 1991 without the benefit of surveyed construction staking. The equipment used was a Caterpillar D8K dozer, a Caterpillar 433 vibratory sheepsfoot, and the import haul trucks with moisture provided by a water hose and a water truck. GradinQ and Earthwork Ooeration The fill materials were imported from the two areas as noted in the section Import Certification. The soils are Silty and Clayey Sands and were placed in lifts of 6 to 8 inches in uncompacted thickness, moistened and compacted. The maximum fill height (toe to top elevation) is approximately 4 feet. Uniform blending of the import materials was difficult and the City Inspector required specific testing and the subsequent removal of the upper 2 feet of the pad. These materials were removed, remoistened, reblended, and recompacted. 2:> I I I I I I I I I I I I I I I I I I I 8S2WRC-56 Page 3 Imoort Certification It is our understanding that approximately 2000 cubic yards of loose, uncompacted import material was delivered to the site to balance the earthwork quantities. The materials were Silty to Clayey Sands and were approved at the borrow areas by the field technician as being suitable for their intended use and inspected to ensure the materials were free of debris. The import materials were brought in from two borrow sites, one located on Jefferson Avenue north of Murrieta Hot Springs Road and one from the Rancho Water waterline trench at Margarita Road and Ynez Road. The import from the waterline trench was refused by the technician following initial use as the A.C. content was too great and. the blocky nature of the earth materials made compaction difficult. Overexcavation In order to provide a stable foundation of compacted native soil beneath the import fill, overexcavation was performed to a depth of 3 feet below existing grade throughout the entire pad area. The bottom of the overexcavation was scarified 6 inches, moistened, and compacted. An inspection and relative compaction tests, performed by the field technician, determined the bottom of the overexcavation to be competent and suitable for the replacement of the overexcavation material. Laboratorv - Testing Maximum Oensitv A representative sample of the compacted material was tested in accordance with ASTM D1557-78, Method A to determine the maximum density. The results are as follows: Location! Material Maximum Optimum Source Classification Densitv. ocf Moisture. % Native Si lty Sand (SM) 126.0 10.0 Import Clayey Sand (SC) 126.0 10.5 Exoansion Index An Expansion Index test was performed in accordance with UBC 29-2 on a representative sample of the import material approximately 14 inches below finish grade. The result is as follows: Location! Source Deoth. BFG Expansion Index Classification Import 14" 37 LOW t\ I I I I I I I I I I I I I I I I I I I 8S2WRC-56 Page 4 Erosion Control In the event of adverse weather conditions prior to residential construction, measures should be taken to minimize erosion damage. Should damage occur (i.e. gullies, washed out slope, erosion scars, etc.) please contact this firm, or a Registered Geotechnical Engineer, to inspect and recommend corrective measures towards mitigating any problems. Following construction, the fill slopes should be planted as quickly as possible with appropriate vegetation as indicated on the Grading Plan or as recommended by a landscape architect. The irrigation system should be adequately constructed and placed to prevent possible washouts due to line breakage. Comoaction TestinQ The tests were performed in accordance with ASTM D1556-90 (Sand Cone Test Method). The test locations are shown on Plate 1 and the results are summarized below: Test ~ 12/ 22/ 35/ 3A3/5/ 3B3/5/ 45/ 5 67/ 77/ 86/ 8A3/6/ 97/ 104/7/ 114/7/ 12 13 14 Elevation1/ 112.0 112.0 113.0 114.0 113.5 114.0 116.0 117.0 116.0 116.5 116.5 117.6 115.5 116.0 116.5 115.5 116.5 Drv Densitv. ocf Field Max 113.9 114.3 109.6 107.8 117.3 117.2 116.0 113.8 114.9 108.1 120.9 103.3 106.5 106.5 119.2 116.0 113.6 126.0 126.0 126.0 126.0 126.0 126.0 126.0 126.0 126.0 126.0 126.0 126.0 126.0 126.0 126.0 126.0 126.0 Moisture. % Field Oot 9.0 10.0 9.5 10.0 10.6 10.0 10.6 10.0 10.4 10.5 10.0 10.5 10.0 10.5 10.4 10.5 9.6 10.5 10.4 10.0 10.4 10.0 11. 7 10.0 9.3 10.0 12.0 10.0 11.0 10.5 9.2 10.5 12.0 10.5 Relative Comoaction. % 90 91 87 86 93 93 92 90 91 86 95 82 84 84 95 92 90 5 I I I I I I I I I I I I I I I I I I I 8S2WRC-56 Page 5 Test Elevation1/ Drv Densitv. ocf Moisture. % Relative ~ Field Max Field Oot Comoaction. % 15 116.5 112.9 126.0 12.1 10.5 90 16 115.5 106.5 126.0 11.1 10.5 85 16A3/ 115.5 122.2 126.0 11. 0 10.5 97 17 116.5 107.3 126.0 13.0 10.5 85 17A3/ 116.5 116.1 126.0 9.5 10.5 92 18 117.5 118.4 126.0 10.5 10.5 94 19 117.5 119.0 126.0 11.0 10.5 95 206/ 116.0 120.8 126.0 8.2 10.5 96 1/ Elevation, in feet, of test is in reference to the finish grade as shown on the Grading Plan 2/ Overexcavation bottom test 3/ Letter denotes retest 4/ Test taken where requested by City Inspector 5/ Overexcavation backfill test 6/ Driveway fill test 7/ Material represented by test removed and recompacted Test Location Plan The basis of the test location plan (Plate 1) is the Grading Plan prepared by Civil Trans, Inc. The test elevations shown assume the finish grade elevation is 118.0 feet as shown on the Grading Plan and are in reference to that elevation. The test location plan contours do not necessarily coincide with the actual field conditions since surveyed construction staking was not provided. cp I I I I I I I I I I I II I I I I I I I 8S2WRC-56 Page 6 CONCLUSIONS AND RECOMMENDATIONS Conclusions 1. The site was properly stripped prior to the overexcavation of the materials. 2. The vegetation was removed from the overexcavated area and was not used in the backfill of overexcavated materials. 3. The fill and backfill of the overexcavated material have been compacted to a minimum relative compaction of 90 percent based on ASTM 01557-78 (unweighted average = 93.0 percent). 4. The bottom of the overexcavation was properly precompacted and premoistened to a depth of 6 inches prior to replacement of the overexcavated materials. 5. The maximum fill height is approximately 4 feet in vertical dimension. 6. A total of 20 quality assurance tests were performed by the Sand Cone Method (ASTM DI556-82), 5 tests (No.s 6, 7, 9-11) were taken in materials subsequently removed and reworked. 7. Import materials were obtained from: (1) the Rancho Water trench at Ynez and Margarita Roads, and (2) a borrow site on Jefferson Avenue just north of Murrieta Hot Springs Road and were approved by our technician as suitable for their intended use. 8. The soils at pad grade have an Expansion Index of 37 or a LOW potential expansion. Recommendations 1. All footings for single story construction shall be a minimum of 12 inches in width and 12 inches in depth, measured below the lowest adjacent compacted or firm grade. For two-story construction, the footings shall be a minimum of 15 inches in width and 18 inches in depth. 2. All footings shall incorporate a minimum of one No.4 bar, placed top and bottom, running continuously through the footings. The bars shall be lapped a minimum of 30 bar diameters and shall be placed approximately 3 inches from the top and bottom, respectively. 3. Slab-on-grade concrete construction should be 4 inches nominal thickness (3 1/2 inches minimum thickness) and should incorporate 6 x 6 No. 10/No. 10 WWF or No.3 rebar placed 30 inches on center. All steel shall be properly tied and placed on 1 1/2 inch blocks. "Pulling" of the mesh during placement of the concrete shall not be permitted. 4. Where moisture sensitive floor coverings are proposed for the house and garage, a moisture barrier, such as 6 mil Visqueen should be used. This membrane should be protected with a minimum of one inch of sand placed above and a minimum of 2 inches of sand below. 1 I I I I I I I I I I I I I I I I I I I 8S2WRC-56 Page 7 Recommendations (continued) 5. The residential slab and garage slab soils shall be presoaked a minimum of 24 hours prior to the concrete pour, and shall have a moisture content of 4 percent above optimum to a depth of 12 inches below slab subgrade prior to pouring the slabs. 6. A garage door grade beam shall be a minimum of 12 inches by 12 inches and shall be reinforced as in #2, above. 7. All footings shall be extended to a depth sufficient to provide a minimum separation of H/2 from the bottom of the footings to the daylight in any adjacent slope (H is the vertical height of the slope). 8. Compaction tests shall be performed on backfill material placed in the CMP trench following installation of the pipe. Respectfully submitted, -Sc$/4 tU'y,"":"'" Scott A. Wynia Project Manager ~/f~ Bruce R. Lee, P. E. GE 509 SAWlks Distribution: Addressee (4) g . ~ l> "0 "0 ::u o x s: ~ ITI 5 ~~ :...tG> o ITI z Z 00 "TJ (') ~ jg ~ o z -l rn -l ~ ~'" o ~~ ~ ~~ -i "'~ Z ~g <:> S?' .. r-(t"I -lei ~~ . 3 z> r>", ;....~ "'eI YZ ~'" "'", ell); !/:Z ~ 00 (J> I" ~ 7" (," ~ l>r -0 ::;!-I \Jl 0- "'-l -1;;0 mp :3~ r:; Cc>> S;;$ 'l5" /") )> r ." C> ~ P ...... --'0, '... " . ~ 1 ...:' -' ., - ------f ..-..,_.._._~ -~~... -.- ... - - - 4~7.111 N.l\"4PU.IJ. ",' ,,/ !j " I I ~ ,.... ,.... ,t! CJ h ~ ~ l"fi Cl ~ 1'1 iY ~ r:':l -i fTI en -i r o (') ~ o Z -0 r )> z ;;1~~ ;!:Or fTl~." :3 ~~~ ~ l>fTlZ .z- ()- l> ;:D l>Cl ~ ~l> G) ~ CJ l> fT1 ;o~O Zl> -I 'i>;o fT1 l>:;>; <08. !\>' VI(/) _ <Ocz o_() -i. fTl l> t-" "' ROAD YNEZ ~ A ,I :1 I I I I I I I I I I I I I I I I I 150 LOCATION NATIVE BORINGITRENCH NO. 145 BORING I TRENCH DEPTH SOIL CLASS SM 11 140 ASTM D 698 METHOD 1\ ASTM D 1557 METHOD A \ \ 135 MAXIMUM DENSITY 1:>6 0 Ibs/ft3 \ OPTIMUM MOISTURE 10 0 0/0 1\ 130 \ 1\ ~ it r<l, ~ \ \ ..... 125 "- \ vi ~ , 1\ - - >- 120 1\1 ~ \ en .Z 1\ W \ 1\ Cl >- 115 1\ n:: 1\ Cl 110 \ 1\ \ 1\ 105 1\ \ 1'\ 100 1\ S.G.=2.50 I\. j>( S.G. =2.60 ZERO AIR SG.=2.70 VOIDS CURVE I\. 95 , '\ 90 0 5 10 15 20 25 30 35 MOISTURE CONTENT (% OF DRY WEIGHT) DATE: MAXIMUM DENSITY CURVE APPENDIX: ~IA Y 1991 A i PROJECT NO,: I CALIFORNIA GEO TEK INC. ~ r8S2WRC-428 42030 AVENIDA ALV~ SUITE A MONDONE TEMECULA CALIFORNIA 390 \0 II I I I I I I I I I I I I I I I I I I 150 100 \ IMPORT LOCATION BORING/TRENCH NO. BORING I TRENCH DEP !\ SOIL CLASS 1\ ASTM D 698 METHO ! \ 1\ ASTM D 1557 METHO !\ MAXIMUM DENSITY \ OPTIMUM MOISTURE \ \ \ If 111 I 1\ 1\\.1 \ .. 1\ \ !\ 1\ 1\ 1\ " !\ \ I\. 1\ SG.=2.50 I. II.- SG. =2.60 -- SG.=2.70 I\. I\. \. " 0/0 145 TH SC 140 D D A 135 3 Ibs/ft. I?fi 0 10 Ii 130 ~ r<). +- - 125 ....... iii .0 ~ >- 120 f- (j') Z W a >- 115 0:: a 110 105 ZERO AIR VOIDS CURVE 95 90 o 5 ~ ~ w ~ ~ MOISTURE CONTENT (% OF DRY WEIGHT) MAXIMUM DENSITY CURVE 35 DATE: MAY 1991 PROJECT NO.: 8S2WRC-428 APPENDIX: A 11 CALIFORNIA GEO TEK INC. 42030 AVENIDA ALVARADi31_SUITE A TEMECULA CALIFORNIA 9,,->90 \; MONDONE \\