HomeMy WebLinkAboutParcel 1-5 Geotech & Compaction
:~EN
I August 16, 2002
I
I
I
I
I
I
I
I
I
I
I
I
I
A'l) c/O-I"' 1<:':;Z df:j;--
COfl~oration
. Soil Engineering and Consulting Services . Engineeril1{JGeology- Compaction Testing
-Inspections. Construction Materials Testing -laboratoryTesting. Percolation Testinll
e Geology. Water Resource Studies . Phasel&JIEnvironmenlalSileAssessmenls
ENVIRONMENTAL & GEOTECHNICAL ENGINEERING NETWORK
'Margarita Canyon, LLC
27311 Jefferson Avenue, Suite 103
Temecula, California 92590
(909) 296-0444 I FAX (909) 296-0448
Attention:
Regarding:
References: 1.
Dear Mr. Grimes:
Mr, Fred Grimes
GEOTECHNICAL REPORT AND COMPACTION TEST RESULTS
POST GRADING OPERATIONS
Margarita Canyon, LLC
Assessor's Parcel Number: 922-110-005
Parcels 1 through 5 of Parcel Maps 28627-1 and 28627-2
Front Street and Western Bypass
City of Temecula, County of Riverside, California
Project Number: T1546-C '
2.
EnGEN Corporation, Pavement Design Recommendations, Margarita
Canyon, LLC, Assessor's Parcel Number: 922-)10-005, Parcels 1 through 5
of Parcel Maps 28627-1 and 28627-2, Front Street and Western Bypass,
City of Temecula, County of Riverside, California, Project Number: T1546-C,
report dated June 24, 2002.
EnGEN Corporation, Geotechnical Report and Compaction Test Results,
Sewertine Trench Backfill, Margarita Canyon, LLC, Assessor's Parcel
Number: 922-110-005, Parcels 1 through 5 of Parcel Map 28627-1 and
28627-2, Front Street and Western Bypass, City of Temecula, County of
Riverside, California, Project Number: T1546-C, report dated May 8, 2002.
Utility Specialists, Inc., GTE Califomia Plans, Front Street and Highway 79,
Work Order 0573-3, plans dated June 15, 2001.
Lohr & Associates, Inc., Street Improvement Plan, Parcel Map No. 28627-
1, City of Temecula, plans dated July 12, 2001.
Lohr & Associates, Inc., Sewer and Water Improvement Plan, Parcel Map
28627-1, City ofTemecula, plans dated December 10,1998.
3.
4.
5.
Pursuant to your request and signed authorization, EnGEN Corporation has performed field
observations, sampling, an~i6H~,lpce density testing on an on-call basis at the above referenced
'>'~
site from May 7, 2002 through ,4,ugust 8, 2002.
, .
" .
~ \ - -. - \
. -
, '
-' - -. I
,
" __. I
, ,
'/ '- ,,/' -' / .... ./
I __ _ ~ I __
,
-
\ ~ ' ,
, .
, .
, '
, "
" .
-' -- ,
" '" "-: \-,~: ~_~~",;;~~~~~~~i:;:1~<I;:;_:<',~'~~::~:~::!~
;..miilli~~i!l!l!i!iiiliiiiii;1iiii;iiiiiiiiiilli iSli1i iiliiiii~iiliiiiii5i
R1l_M_:~==~::~_.!IU!!ll=~~~:;=~Mlft~=M~~~~~~~~~~~~
- 'e::' . "'"f --~." ._.,..~-"'"'-=_._~
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
II
Margarita Canyon, LLC
Project Number: T1546-C
August 2002
Page 2
The following testing was performed during post grading operations:
. Waterline Trench Backfill . Dry Utility Trench Backfill
. Sidewalk Subgrade . Driveway Approach Subgrade
. Curb and Gutter . Driveway Approach Aggregate Base
. Front Street and Western Bypass . Front Street and Western Bypass
Subgrade Aggregate Base
Maximum dry density/optimum moisture content tests were conducted on samples of the native
earth materials and imported aggregate base. The tests were performed in general accordance
with ASTM D 1557-91 (1998) procedures. The results are presented in the Appendix of this
,report. Relative compaction testing was performed in general accordance with ASTM D
2922-96 and ASTM D 3017-96 procedures for determining in-place density and moisture
content, respectively, using nuclear density gauge equipment. Test results are presented in the
Appendix and the approximate test locations are shown on the site plan, also presented in the
Appendix of this report.
In-place density test results indicate a minimum of 90 percent relative compaction for the
Sidewalk subgrade, the curb and gutter subgrade and trench backfill areas of the site, and 95
percent relative compaction for the driveway approach subgrade, Front Street and Western
Bypass subgrade, and in the aggregate base. The native soils encountered on the site
consisted of brown silty sand as well as dark brown sandy silt. Import earth materials consisted
of gray sandy gravel aggregate base.
Based on the observations and tests performed in the areas noted as test locations, the post
grading operation has been completed in accordance with the Referenced NO.1 Report and the
grading code of the City of Temecula, California.
EnGEN Corporation
-z"
I
I
I
I
II
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Margarita Canyon, LLC
Project Number: T1546-C
August 2002
Page 3
Thank you for the opportunity to provide these services. If you should have any questions
regarding this report, please do not hesitate to contact this office at your convenience.
Respectfully submitted,
EnGEN oration
SRW/OB:hh
Distribution: (4) Addressee
FILE: EnGEN/Reporting/CfT1546-C Margarita Canyon, Post Grading
EnGEN Corporation
.?>
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Margarita Canyon, LLC
Project Number: T1546-C
Appendix Page 1
APPENDIX:
TEST RESULTS
EnGEN Corporation A...
II
I
Margarita Canyon, LLC
Project Number: T1546-C
Appendix Page 2
FIELD TEST RESULTS
(Summary of Field In-Place Density Test Results)
(Nuclear Gauge Test Method)
(5. G.) = Subgrade / (F. G.) = Finish Grade
Test
Date
(2002)
Test Locations
Depth
Elevation
(FT)
Soil
Type
Max
Density
(PCF)
Moisture
Content
(%)
Dry
Density
(PCF)
Relative
Compaction
(%)
Required
Compaction
(%)
1 05-07 Waterline STA 17+69 8.G, A3 123.5 13.0 114.2 92,5% 90.0%
I 2 05-07 Waterline STA 18+92 8.G. A1 131.6 9.3 120.1 91.3% 90.0%
3 05-07 Waterline STA 19+12 8.G. A3 123.5 11.6 116.5 94,3% 90.0%
I 4 05-16 Waterline STA 17+11 -2 A3 123.5 9.5 119.4 96.7% 90.0%
5 05-16 Waterline STA 17+60 -2 A3 123.5 9.1 112.1 90.8% 90.0%
6 05-16 Waterline STA 18+20 -2 A3 123.5 8.2 117.8 95.4% 90.0%
7 05-16 Waterline STA 17+20 8.G. A3 123.5 9.1 112.1 90.8% 90.0%
8 05-16 Waterline STA 17+75 -2 A3 123.5 9.9 119.3 96.6% 90.0%
9 05-16 Waterline 5T A 16+56 -1 A3 123.5 11.9 112.1 90.8% 90.0%
10 05-29 Dry Utilities -1 A1 131.6 9.8 121.1 92.0% 90.0%
11 05-29 Dry Utilities -1 A1 131.6 9.3 120.7 91.7% 90.0%
12 05-30 Dry Utilities -1 A1 131.6 9.1 121.7 92.5% 90.0%
13 05-30 Dry Utilities -1 A1 131.6 8.6 120.7 91.7% 90.0%
14 05-31 Dry Utilities 8.G. A1 131.6 10.0 118.6 90.1% 90.0%
15 05-31 Dry Utilities 8.G. A3 123.5 6.8 114.1 92.4% 90.0%
16 06-03 Dry Utilities -2 A2 127.5 11.5 118.4 92.9% 90.0%
17 06-04 Dry Utilities -1 A3 123.5 14.8 108.3 87.7% 90.0%
18 06-04 Retest #17 -1 A3 123.5 13.5 112.6 91.2% 90.0%
19 06-04 Dry Utilities -1 A3 123.5 15.1 113.2 91.7% 90.0%
20 06-04 Dry Utilities -1 A3 123.5 14.0 114.0 92.3% 90.0%
21 06-04 Dry Utilities 8.G. A1 131.6 7.2 120.0 91.2% 90.0%
22 06-04 Dry Utilities 8.G. A1 131.6 8.1 119.5 90.8% 90.0%
23 06-06 Dry Utilities -1 A3 123.5 8.4 113.2. 91.7% 90.0%
24 06-06 Dry Utilities 8.G. A3 123.5 10.2 114.0 92.3% 90.0%
25 06-07 Dry Utilities 8.G. A1 131.6 9.2 122.7 93.2% 95.0%
I 26 06-07 Retest #25 8.G. A1 131.6 13.4 125.3 95.2% 95.0%
27 06-07 Dry Utilities 8.G. A1 131.6 13.2 123.0 93.5% 95.0%
28 06-07 Retest #27 8.G. A1 131.6 12.3 125.0 95.0% 95.0%
29 06-07 Dry Utilities Base C1 138.4 5.8 133.7 96.6% 95.0%
30 06-07 Dry Utilities Base C1 138.4 6.2 131.8 95.2% 95.0%
I 31 06-11 Curb & Gutter 8.G. A3 123.5 10.7 111.8 90.5% 90.0%
32 06-11 Curb & Gutter 8.G. A3 123.5 8.9 117.5 95.1% 90.0%
33 06-11 Curb & Gutter 8.G. M 132.0 8.5 124.5 94.3% 90.0%
I
II
EnGEN Corpomtion
~
I
I
Margarita Canyon, LLC
Project Number: T1546-C
Appendix Page 3
FIELD TEST RESULTS
(Summary of Field In-Place Density Test Results)
(Nuclear Gauge Test Method)
I (5. G.) = 5ubgrade / (F. G.) = Finish Grade
Test Depth Soil Max Moisture Dry Relative Required
I Test Date Test Locations Elevation Density Content Density Compaction Compaction
No. (2002) (FT) Type (PCF) (%) (PCF) (%) (%)
I 34 06-11 Curb & Gutter S,G. A1 131.6 7.3 119.5 90.8% 90.0%
35 06-11 Curb & Gutter S.G. A1 131.6 7.4 123.8 94,1% 90.0%
36 06-11 Curb & Gutter S.G. A1 131.6 7.7 120.1 91.3% 90.0%
I 37 06-11 Curb & Gutter S.G. A1 131.6 6,8 115.0 87.4% 90.0%
38 06-11 Retest #37 S.G. A1 131.6 8.7 119.1 90.5% 90.0%
I 39 06-11 Dry Utilities S.G. A1 131.6 7.8 124.2 94.4% 95.0%
40 06-11 Retest #39 S.G. A1 131.6 10.7 125.1 95.1% 95.0%
41 06-11 Dry Utilities Base C1 138.4 7.2 132.4 95.7% 95.0%
I 42 06-11 Dry Utilities Base C1 138.4 3.4 125.6 90.8% 95.0%
43 06-11 Retest #42 Base C1 138.4 6.8 134.5 97.2% 95.0%
I 44 06-12 Dry Utilities S.G. A1 131.6 8.9 120.4 91.5% 95.0%
45 06-12 Retest #44 S,G. A1 131.6 7.8 125.8 95.6% 95.0%
46 06-12 Dry Utilities Base C1 138.4 6.8 133.1 96.2% 95.0%
I 47 06-12 Dry Utilities Base C1 138.4 7.2 134,8 97.4% 95.0%
48 06-12 Driveway Approach S.G. A4 132.0 8.9 115.0 87.1% 95.0%
I 49 06-13 Driveway Approach S.G. A5 128.3 7.8 124.8 97.3% 95.0%
50 06-13 Retest #48 S.G. A5 128.3 12.6 122.6 95.6% 95.0%
I 51 06-13 Driveway Approach S.G. A5 128.3 7.4 125.1 97.5% 95.0%
52 06-13 Dry Utilities -1 A3 123.5 14.3 111.2 90.0% 90.0%
53 06-13 Dry Utilities S.G. A3 123.5 12.3 119.8 97.0% 95.0%
I 54 06-13 Dry Utilities Base C1 138.4 9.1 133.2 96.2% 95.0%
55 06-14 Dry Utilities -2 A5 128.3 12.6 116.8 91.0% 90.0%
I 56 06-14 Dry Utilities S.G. A1 131.6 8.9 127.7 97.0% 95.0%
57 06-17 Front Street S.G, AS 128.3 8.9 125.0 97.4% 95.0%
58 06-17 Front Street S.G. A3 123.5 14.9 117.3 95.0% 95.0%
I 59 06-17 Front Street Base C2 132.8 7.7 130.8 98.5% 95.0%
60 06-17 Western Bypass Base C2 132.8 6.3 130,2 98.0% 95.0%
61 06-18 Driveway Approach Base C2 132.8 6.2 128.9 97,1% 95.0%
I 62 06-18 Driveway Approach Base C2 132.8 6.7 130.8 98.5% 95.0%
63 06-18 Cross Cutter Base C2 132.8 6.1 128.0 96.4% 95.0%
I 64 06-20 Dry Utilities Base C2 132.8 7.3 126.3 95.1% 95.0%
65 06-20 Dry Utilities Base C2 132.8 9.2 128.3 96.6% 95.0%
66 06-20 Dry Utilities Base C2 132.8 5.7 127.1 95.7% 95.0%
I
I
~
EnGEN Corpuratioll
Margarita Canyon, LLC
Project Number: T1546-C
Appendix Page 4
FIELD TEST RESULTS
(Summary of Field In-Place Density Test Results)
(Nuclear Gauge Test Method)
(5. G.) = 5ubgrade / (F. G.) = Finish Grade
Test
No.
Test
Date
(2002)
Test Locations
Depth
Elevation
(FT)
Soil
Type
Max
Density
(PCF)
Moisture
Content
(%)
Dry
Density
(PCF)
Relative
Compaction
(%)
Required
Compaction
(%j
67 06-20 Dry Utilities Base C2 132.8 5.8 128.3 96.6% 95,0%
I 68 06-21 Dry Utilities 5.G. A5 128.3 6.9 117.3 91.4% 90,0%
69 06-21 Dry Utilities 5.G. A5 128.3 8.1 118.1 92.0% 90,0%
I 70 06-21 Dry Utilities 5.G. A5 128.3 9.2 119,6 93.2% 90.0%
71 06-24 Dry Utilities -1 A5 128.3 9.7 116.9 91.1% 90.0%
72 06-24 Dry Utilities 5.G. A5 128.3 10.1 115,9 90.3% 90.0%
73 06-26 Dry Utilities 5.G. A5 128.3 10.9 117.2 91.3% 90.0%
74 07-01 Front Street 5.G. A4 132.0 8.8 129,3 98.0% 95.0%
I 75 07-01 Front Street 5.G. A4 132.0 9.8 126.0 95.5% 95.0%
76 07"01 Front Street 5.G. A5 128.3 9.9 121.9 95.0% 95.0%
I 77 07-01 Front Street 5.G. A3 123.5 9.9 117.9 95.5% 95.0%
78 07-01 Front Street 5.G. A3 123.5 9.8 103.4 83.7% 95.0%
79 07-02 Retest #78 5.G. A3 123.5 9.9 117.9 95.5% 95.0%
I 80 07-02 Western Bypass 5.G. A5 128.3 9.7 122.4 95.4% 95.0%
81 07-03 Western Bypass 5.G. A3 123.5 10.1 117.7 95.3% 95.0%
I 82 07-03 Western Bypass 5.G. A3 123.5 11.7 117.3 95.0% 95.0%
83 07-03 Western Bypass 5.G. A3 123.5 9.4 120.1 97.2% 95.0%
84 07"08 Front Street Base C3 134.7 8.7 128.3 95.2% 95.0%
I 85 07-08 Front Street Base C4 126.0 9.1 122.3 97.1% 95.0%
86 07-08 Front Street Base C4 126.0 8.7 121.5 96.4% 95.0%
I 87 07-08 Front Street Base C4 126.0 9.2 120.8 95.9% 95.0%
88 07-08 Front Street Base C4 126.0 9.7 123.8 98.3% 95.0%
89 07-08 Western Bypass Base C4 126.0 8.2 119.9 95.2% 95.0%
I 90 07-08 Western Bypass Base C4 126.0 10.6 123.0 97.6% 95.0%
91 07-08 Western Bypass Base C4 126.0 9.5 119.8 95.1% 95.0%
I 92 07-08 Western Bypass Base C4 126.0 11.6 125.4 99.5% 95.0%
93 07-08 Drive Approach 5.G. A3 123.5 9.6 117.3 95.0% 95.0%
94 07-09 Sidewalk 5.G. A5 128.3 10.8 117.7 91.7% 90.0%
I 95 07-09 Sidewalk 5.G. A5 128.3 9.7 118.2 92.1% 90.0%
96 07_09 Sidewalk 5.G. A5 128.3 9.9 116.9 91.1 % 90.0%
I 97 07-09 Sidewalk 5.G. A5 128.3 9.8 118.5 92.4% 90.0%
98 07-09 Sidewalk 5.G. A3 123.5 9.4 114.4 92.6% 90.0%
99 07'09 Retest #73 5.G. A3 123.5 10.1 111.4 90.2% 90.0%
I
I
EnGEN Corpor.\tion
'\
I
I
Margarita Canyon, LLC
Project Number: T1546-C
Appendix Page 5
FIELD TEST RESULTS
(Summary of Field In-Place Density Test Results)
(Nuclear Gauge Test Method)
(5. G.) = Subgrade / (F. G.) = Finish Grade
Test
Date
(2002)
Test Locations
Depth
Elevation
(FT)
Soil
Type
Max
Density
(PCF)
Moisture
Content
('!o)
Dry
Density
(PCF)
Relative
Compaction
('!oj
Required
Compaction
('!oj
100 07-09 Sidewalk S.G. A3 123.5 11.4 111,8 90.5% 90.0%
101 07-09 Sidewalk S.G. A3 123,5 9.7 117,2 94.9% 90,0%
102 07-09 Sidewalk S.G. A3 123.5 9.0 111.2 90.0% 90.0%
103 07-10 Western Bypass Base C4 126.0 9.3 121.5 96.4% 95.0%
104 07-10 Western Bypass Base C4 126.0 8.6 123.8 98.3% 95.0%
105 07-10 Western Bypass Base C4 126.0 7.0 122.9 97.5% 95.0%
106 07-10 F rant Street Base C4 126.0 8.9 124.6 98.9% 95.0%
107 07-10 F rant Street Base C4 126.0 8.0 121.9 96.7% 95.0%
108 07-10 Front Street Base C4 126.0 7.9 120.5 95.6% 95.0%
109 07-10 Front Street Base C4 126.0 8.9 121.8 96.7% 95.0%
110 07-10 Western Bypass Base C4 126.0 9.2 120,0 95.2% 95.0%
111 07-10 Western Bypass Base C4 126.0 8.3 121.0 96.0% 95.0%
112 08-08 Dry Utilities -2 A5 128.3 7.9 117.6 91.7% 90.0%
113 08-08 Dry Utilities Base C3 134.7 7.2 128.9 95.7% 95.0%
114 08-08 Dry Utilities Base C3 134.7 6.7 130.1 96.6% 95.0%
I
I
I
I
I
I
I
I
I
EnGEN Curporation
B
-,
! '.
I
-.
J
,
I
I
I
I
I
I
I
I
I
I
I
I
I
Margarita Canyon, LLC
Project Number: T1546-C
Appendix Page 6
SUMMARY OF OPTIMUM MOISTURE CONTENT
MAXIMUM DRY DENSITY RELATIONSHIP TEST RESULTS
ASTM D 1557-91 (1998)
Maximum Optimum
Soil Description (USCS Symbol) Soil Type Dry Density Moisture
(PCF) Content (%)
Silty Sand, Brown (SM) A1 131.6 9.2
Silty Sand, Brown (SM) A2 127.5 9.7
Sandy Silt, Dark Brown (ML) A3 123.5 11.5
Silty Coarse Sand, Brown (SM) A4 132.0 10.3
Silty Coarse Sand, Brown (SM) A5 128.3 9.7
Sandy Gravel, Gray (GW) C1 138.4 . 7.5
Sandy Gravel, Gray (GW) C2 132.8 7.7
Sandy Gravel, Gray (GW) C3 134.7 8.2
Sandy Gravel, Gray (GW) C4 126.0 10.7
EnGEN Corporation
l\
I
I
I
'1
I
I
I
I
I
I
I
I
I
I
! I
I
! I
I
I
Margarita Canyon, LLC
Project Number: T1546-C
Appendix Page 7
APPENDIX:
DRAWINGS
. \0
EnGEN CorpomtlOo