Loading...
HomeMy WebLinkAboutParcel 2 Geotechnical & Compaction I I I I I I I I I I :. I I I I I I 'I I I @~orp~JJ~ GEOTECHNICAL REPORT AND COMPACTION TEST RESULTS ROUGH GRADING OPERATIONS Industrial Condominiums of T emecula Assessor's Parcel Number: 909-370-024 Parcel 2 of Parcel Map 28657-1 Remington Avenue City of Temecula, County of Riverside, California Project Number: T3144-C May 10, 2006 Prepared for: Industrial Condominiums of Temecula, LLC 13007 Kirkham Way, Suite A Poway, California 92064 .' 5 7",~ ~'.'1--T_L _...c.,.... c 0.' 'oJ 2.:. '_'''~ C.-.' :" 9 ':..:,. !.".< .';is diJ ~,,_tJl \ I I I ,I II I I I I I I I I I I I I I I I Industrial Condominiums of Temecula, LLC Project Number: T3144-C TABLE OF CONTENTS SECTION NUMBER AND TITLE PAGE 1 ~O SITE/PROJECT DESCRIPTION AND LOCATION ..................................................................... 2 1.1 PROJECT LOCATION .................................................................................................2 1..2 SITE DESCRIPTION...................................................................................................2 1.3 PROJECT DESCRiPTION..... ........... .............. ............ ................... ....... ...... ......... ...... ...2 2.0 SCOPE OF WORK ............................................................................................................. 2 2.1 TIME OF GRADING....................................................................................................2 2.2 CONTRACTOR AND EQUIPMENT .................................................................................2 2.3 GRADING OPERATIONS ............................................................................................2 2.4 FIELD TESTING PROCEDURES.... ............. ........ ........... .............. ................ .................3 2.5 LABORATORY TESTING .................... .................... ........................................ .... ...... ...3 2.5.1 MOISTURE-DENSITY RELATIONSHIP TEST ................................................... 3 2.5.2 EXPANSION INDEX TEST ............................................................................ 3 2.5.3 SOLUBLE SULFATE TEST ........................................................................... 4 3.0 EARTH MA TERIALS........................................................................................................... 4 4,0 CONCLUSIONS AND RECOMMENDATIONS ........................................................................... 4 4: 1 GENERAL 4 5.0 CLOSURE......................................................................................................................... 5 APPENDIX: TEST RESULTS DRAWINGS EnGEN Corporation '}, I II I I ,I I I I I II II I I I , I I I I I @ ~Orp~A~'!~ May 10, 2006 Industrial Condominiums of Temecula, LLC 13007 Kirkham Way, Suite A Poway, California 92064 (858) 391-9009 I FAX (858) 391-3093 Attention: Mr. Norm Turoff Regarding: GEOTECHNICAL REPORT AND COMPACTION TEST RESULTS ROUGH GRADING OPERATIONS Industrial Condominiums of Temecula Assessor's Parcel Number: 909-370-024 Parcel 2 of Parcel Map 28657-1 Remington Avenue City of Temecula, County of Riverside, Califomia Project Number: T3144-C References: 1. EnGEN Corporation, Supplemental Geotechnical Engineering Study, Remington Avenue II, Assessor's Parcel Number: 909-370-024, Parcel 2 of Parcel Map 28657-1, Remington Avenue, City of Temecuia, County of Riverside, California, Project Number: T3144-SGS, dated April 26, 2004. 2. EnGEN Corporation, Response To County Review Comments, County Geologic Report No. 1353, City of Temecula Project No. PA 04-0361, Remington Avenue II, Assessor's Parcel Number: 909-370-024, Parcel 2, Parcel Map 28657-1, Remington Avenue, City of Temecula, County of Riverside, California, Project Number: T3144-CS, dated October 8,2004. . 3. EnGEN Corporation, Review Of Proposed Building Locations With Respect To Restricted Use Zone, Industrial Condominiums of Temecula, Assessor's Parcel Number: 909-370-024, Parcel 2, Parcel Map 28657-1, Remington Avenue, City of Temecula, County of Riverside, California, Project Number: T3144-CS1, dated March 1, 2005. 4. Spear and Associates, Inc, Precise Grading and Erosion Control Plan, Industrial Condominiums of Temecula, Parcel 2, Parcel Map 28657-1, PA 05- 0127, City ofTemecula, plans dated April 18, 2006. Dear Mr. Turoff: In accordance with your request and signed authorization, EnGEN Corporation has performed field observations, sampling, and in-place density testing at the above referenced site. Submitted, herein, are the test results and the supporting field and laboratory data. "',1',-' ,'-". _ ,. .."\ ,~,~.,'..._ 'I', .....,. t ,", ,',.. r-.l.; '~:...!. 1,'.., H.J'J' c.. '/'1,' I, \4.... .:~;' ? I I I II I I I I I I I I I I I I I I I Industrial Condominiums of Temecula, LLC Project Number: T3144-C May 2006 Page 2 1.0 SITE/PROJECT DESCRIPTION AND LOCATION 1.1 PROJECT LOCATION The subject site consists of approximately 5.43-acres, located on the northeast side of Remington Avenue southwest of the intersection of Remington Avenue and Diaz Road in the City of Temecula, County of Riverside, California. 1,.2 SITE DESCRIPTION Based on the Referenced NO.1 Supplemental Geotechnical Study, the site was previously rough graded and is underlain by approximately 14 to 17-feet of previously engineered fill material. Prior to current grading operations, topography and surface conditions of the site were relatively flat with surface drainage to the east at a gradient of less than 2 percent. 1.3 PROJECT DESCRIPTION It is understood that the subject site is to be developed with three (3) commercial! industrial buildings with slab-on-grade concrete floors supported on conventional continuous and pier footings, with associated driveway as well as hardscape and landscape improvements. 2.0 SCOPE OF WORK 2.1 TIME OF GRADING This report represents geotechnical observations and testing during the construction operations from May 1, 2006 through May 4, 2006. 2.2 CONTRACTOR AND EQUIPMENT The grading operations were performed by Mike Sampo, Inc. through the use of one (1) CAT 613 scraper, one (1) skip loader, one (1) backhoe with sheeps foot compaction wheel, one (1) motor grader and one (1) water truck. 2.3 GRADING OPERATIONS Grading within the subject site consisted of a cut/fill operation. Grasses and weeds were removed prior to fill placement. Fill material was generated from the parking lot and driveway portions of the site, and used to bring the building pad portions of the site to finish grade elevation. Bottoms were observed, probed and found to be into competent previously engineered fill material by a representative of this firm. EnGEN Corporation A I I I I I I i I I I I I I I I I I I I I Industrial Condominiums of Temecula, LLC Project Number: T3144-C May 2006 Page 3 Over-excavation was performed in the building pad to a depth of 1-foot below finish grade elevation and to a distance of 5-feet outside the proposed structures. The exposed bottoms were scarified and moisture conditioned to a depth of 12-inches then compacted to 90 percent. Fill was placed in lens thicknesses of 6 to 8-inches, thoroughly moisture conditioned to near optimum moisture content, then compacted to a minimum of gO percent relative compaction. Moisture conditioning of the on-site soils was performed during the compaction process through the use of a water truck. The pad areas were generally graded to the elevations noted on the Grading Plan. However, the actual pad locations, dimensions, elevations, slope locations and inclinations, etc. were surveyed and staked by others and should be verified by the Project Civil Engineer. 2.4 FIELD TESTING PROCEDURES Field in-place density and moisture content testing were performed in general accordance with ASTM 0 2922-03 and ASTM 0 3017-01 procedures for determining in-place density and moisture content, respectively, using nuclear gauge equipment. Relative compaction test results were within the 90 percent required for all material tested, which is an indication that the remainder of the fill placed has been properly compacted. Test results are presented in the Appendix of this report. Fill depths and test locations were determined from review of the referenced grading plans. 2.5 LABORATORY TESTING The following laboratory tests were performed as part of our services during the grading of the subject site. The test results are presented in the Appendix of this report. 2.5.1 MOISTURE-DENSITY RELATIONSHIP TEST Maximum dry density-optimum moisture content relationship tests were conducted on samples of the materials used as fill. The tests were performed in general accordance with ASTM D 1557-02 procedures. 2.5.2 EXPANSION INDEX TEST A soil sample was obtained for expansion potential testing from the building pad area upon completion of rough grading of the subject site. The expansion test was performed in accordance with CBC 18-2. The material tested consisted of brown silty sand, which has an Expansion Index of 9. This soil is classified as having a very low expansion potential. EnGEN Corporation ~ I I I I I I I I I I I I I I I I I I I Industrial Condominiums of Temecula, LLC Project Number: T3144-C May 2006 Page 4 The results are presented in the Summary of Expansion Index Results in the Appendix of this report. 2.5.3 SOLUBLE SULFATE TEST Based on this firm's familiarity with the soils used to construct the building pad, it is our opinion that soluble sulfates are not a concern, and as a result, normal Type II cement can be used in concrete making contact with the native soils. 3.0 EARTH MATERIALS The natural earth materials encountered on-site generally consisted of brown silty sand. 4.0 CONCLUSIONS AND RECOMMENDATIONS No conditions were encountered which would cause a change in the previously provided design and construction recommendations. As a result, design and construction should adhere to the recommendations provided in the Referenced No. 1 Supplemental Geotechnical Engineering Study. 4.1 GENERAL Based on the observations and tests performed during grading, the subject site in the areas noted as test locations has been completed in accordance with the referenced Supplemental Geotechnical Study, the project plans and the Grading Code of the City of Temecula. The graded site, in the areas noted as graded, is determined to be adequate for the support of a typical commercial/industrial development. Any subsequent grading for development of the subject property should be performed under engineering observation and testing performed by EnGEN Corporation. Subsequent grading includes, but is not limited to, any additional fill placement and excavation of temporary and permanent cut and fill slopes. In addition, EnGEN Corporation should observe all foundation excavations. Observations should be made prior to installation of concrete forms and/or reinforcing steel so as to verify and/or modify, if necessary, the conclusions and recommendations in this report. Observations of overexcavation cuts, fill placement, finish grading, utility or other trench backfill, pavement subgrade and base course, retaining wall backfill, slab presaturation, or other earth work completed for the development of the subject site should be performed by EnGEN Corporation. If any of the observations and testing to verify site geotechnical conditions are not performed by EnGEN Corporation, liability for the safety EnGEN Corporation ~ I I I I I I I I I I I I I I I I I I I Industrial Condominiums of Temecula, LLC Project Number: T3144-C May 2006 Page 5 and performance of the development is limited to the actual portions of the project observed and/or tested by EnGEN Corporation. 5.0 CLOSURE This report has been prepared for use by the parties or project named or described above. It mayor may not contain sufficient information for other parties or purposes. The findings and recommendations expressed in this report are based on field and laboratory testing performed during the rough grading operation and on generally accepted engineering practices and principles. No further warranties are implied or expressed beyond the direct representations of this report. Thank you for the opportunity to provide these services. If you should have any questions regarding this report, please do not hesitate to contact this office at your convenience. Distribution: (4) Addressee FILE: EnGEN/ReportinglCfT3144-C Ind. Condos of Temecula, lLC, Rough grading EnGEN Corporation \.. I I I I I I II I I I I I I I I I I I I APPENDIX: TEST RESULTS Industrial Condos of Temecula, LLC Project Number: T3144-C Appendix Page 1 \ EnGEN Corporation ~ I I II I I I I I I I I I I I I I I I I Industrial Condos of Temecula, LLC Project Number: T3144-C Appendix Page 1 SUMMARY OF OPTIMUM MOISTURE CONTENT MAXIMUM DRY DENSITY RELATIONSHIP TEST RESULTS ASTM D 1557-02 Soil Description (USCS Symbol) Soil Type Maximum Dry Optimum Moisture Content Density (PCF) (%) Silty Sand Brown (SM) A1 133.3 6.7 SUMMARY OF EXPANSION INDEX TEST RESULTS CBC 18-2 Dry Moisture Moisture Expansion Soil Type Depth (FT) Density Condition Condition Index (pcf) Before Test After Test E1 -1 114.2 8.0% 16.0% 9 EnGEN Corporation <\ I II I I I I I ,I I I I I I I I I I I I Industrial Condos of Temecula, LLC Project Number; T3144-C Appendix Page 1 FIELD TEST RESULTS (Summary of Field In-Place Density Test Results) (Nuclear Gauge Test Method) (S.G.) = Subgrade / (F. G.) = Finish Grade Test Test Depth Max Moisture Dry Relative Required No. Date Test Locations Elevation Soil Type Density Content Density Compaction Compaction (2005) (FT) (PC F) (%) (PCF) (%) ('!o) 1 05,01 PadA -1 A1 133.3 8.0 120.1 90.1% 90.0% 2 05-01 PadA -1 A1 133.3 7.6 121.2 90.9% 90.0% 3 05-01 PadB -1 A1 133.3 7.9 120.8 90.6% 90.0% 5 05-01 Pad C -1 A1 133.3 7.2 120.6 90.5% 90.0% 6 05-01 PadC -1 A1 133.3 7.3 121.8 91.4% 90.0% 7 05-03 PadB FG A1 133.3 6.8 122.4 91.8% 90.0% 8 05-03 Pad B FG A1 133.3 6.0 123.2 92.4% 90.0% 9 05-04 Pad A FG A1 133.3 4.9 124.4 93.3% 90.0% 10 05-04 Pad A FG A1 133.3 5.1 122.9 92.2% 90.0% 11 05-04 Pad C FG A1 133.3 5.1 121.8 91.4% 90.0% 12 05-04 PadC FG A1 133.3 4.7 121.0 90.8% 90.0% EnGEN Corporation \0 I II I I ,-I , I II I I I I I II I I I I II I APPENDIX: DRAWINGS Industrial Condos of Temecula, LLC Project Number: T3144.C Appendix Page 4 EnGEN Corporation \\'