HomeMy WebLinkAboutTract Map 3883 Lot 101 Rough Grading T .FI~E. Soils Co., lnc_ 'Phone: (951) 894-2121 FAX: (951) 894-2122 41548 Eastman Drive, Unit G . Murrieta, CA 92562 . \l2. ~ !A" le\ E-mail: thesoilsco@aol.com . September 29,2005 Mr. Karl Lowry Lowry Construction 9550 Hermitage Lane Riverside, California 92503 SUBJECT: REPORT OF ROUGH GRADING Proposed Single-Family Residential Pad Lot 101 of Tract No. 3883 Carmelita Circle City of Temecula, Riverside County, California Work Order No. 945501.22 REFERENCES: WAC Geotechnical, Inc., dated February 26, 2004, "Subsurface Soils Engineering Investigation for Proposed Residential Building Construction and Foundation Evaluation for Property Located at Carmelita Circle, Temecula, California", Project Number 04-660. R.C. Enterprise, dated June 8, 2004, "Precise Grading, Erosion & Sediment Control Plan, Karl Lowery, Lot 101 - Tract 3883, Temecula, California", Sheets I & 2 of 2, Scale: 1"=20'. Dear Mr. Lowry: INTRODUCTION In accordance with your request, we have prepared this "Report of Rough Grading" presenting the results of our observation and testing during rough grading operations for the proposed single- family residential pad located at the above referenced parcel I of PM 25715. All compaction test results are included in Appendix B of this report. In accordance with Section 3317.8 of the 2001 California Building Code (CBC), effective August 15, 2005, T.H.E. Soils Company, Inc. became the Engineer of Record for the subject site. Rough grading operations were performed in accordance with the requirements of the City of Temecula and the 2001 CBC. Highpoint Grading contractors performed rough grading operations. The 20-scale "Precise Grading, Erosion & Sedimentary Control Plan" for the subject site, prepared by R.C. Enterprise of Hemet, California, was utilized during grading to locate our field density tests and was utilized as a base map for our test locations presented as Plate 1. THE SOILS COMPANY, INC. W. O. No. 945501.22 \ -'-_.~---- ....._-,~..- - "-='-."'~- - . . Mr, Karl Lowry Lowry Construction September 29, 2005 Page 2 Proposed Development It is our understanding that the subject site is proposed for the construction of a two-story single- family residencf' with slab-on-grade foundation and conventional footings. Typical cut/fill grading was utilized to establish design grade, Grading included clearing, grubbing, overexcavation, and placement and compaction of fill material to prepare the site. Site Description The subject site (Lot 101 of Tract No. 3883) is located along the south side of Carmel ita Circle in the city of Temecula in southwest Riverside County, California. The site is bordered by large parcel residential development. The geographical relationships of the site and surrounding features are represented on the attached Site Location Map, Figure 1. Prior to rough grading, the portion of the subject property proposed for development consisted of moderate sloping terrain with natural gradients that varied from approximately 5 to 25%. Prior to grading, drainage was generally accomplished by sheetflow to the south-southwest toward a moderately incised drainage course. Overall relief on the subject parcel in the vicinity of the proposed grading was approximately :t24-ft. Vegetation on the subject site consisted of a low growth of annual weeds and grasses. GRADING PROCEDURES Site Preparation Prior to the commencement of grading, the subject site was cleared of vegetation and debris, which wa~ disposed of off-site, The proposed building pad was overexcavated a minimum of 4 to 5-ft below natural ground and to a minimum of 5-ft outside of the building footprint as staked by the contractor. Medium dense to dense sedimentary bedrock units, that are free of pinpoint pores and fine roots were exposed throughout the overexcavation. The exposed bottom was scarified a minimum of l2"inches, brought to near optimum moisture content, and compacted to at least 90% relative compaction. Overexcavation was accomplished utilizing a Caterpillar 0-8 dozer. The fill materials were leveled and mixed with the Cat. D-8 dozer. Compaction was achieved by wheel rolling with a loaded and unloaded front end loader and water truck. Moisture conditioning was achieved utilizing a water truck. TilE SOILS COMPANY INC W. O. No. 945501.22 Z- o 0 ~;'.!l'~' ~'. , "",-v,. \)~'~'Y~": ~~~~lii/7r(~~4;i~~, ..:o.~~ 'j--' ,1:; ;' -" ,_2?sI "-G-1?'~~r,~~~;() '- rr-J:"'Y'Ju\!C'.' I~' /' ,'l~~L1:~\,':':-,.,~;:;~;,'---- ..<>-"~~ OI",z);r'~zJ .~f o. 1 ~/:1'\~-~ \\"~..i.-:./ "I'\~~ .- . ~~,..( '1/ :~I(r-c> J~""~~r 'V' '1/1 l)~: .,-. ..../1 ~"-'- U;,!/r'iY',;:;d;o.-::-:1~ ,cP.~~sh f. :,,~, . ~~:Jlv/24l'7', .....: '.l!!f~ L,"!;;'_.,:Wt~fL-~:,:; ,-: ~" ,}-J _ -......... -"(L~~~~ I"'~".- -., ........-.....-;;;0 ....i ~ ......( h -~~\.~ :..:;;., !~ '-.~- ,\ In' '" ~./ 1'.0 r ,~~ F-:...) .... <# . ~:;:;'-=/t'A I _"~.~-_9..t-..r --- ; '"" ",I X; ,\ I~ /::=:.) -i-"'j _,,' ~I M'. -',,,, '<-, "....1..0':.,:1 ~ =;/rvt '~JCV: "- ~?1 / <' / r Fi f(~ " ,~~c...-r:., 1,0 ,:, >.~ <'~'-;","':.;',1k. I~)fl[ ~~q]0~'41~~~~ ?;1~,,~~~1~ '1C.1r-/J'*~_::_;,J:1;'~l\<<;~~ ~~14(,~ ,c/Jr/[~ lO ~:"::" J~\ b~~~ffl~'~?~~]l~~ 't~!j '.. "illj, S i:' Ik \ ~t~! ~ 1'1 '- ;: >~\.-.-- 'V,;~ ~.:/i 'i/: 2 \ ---- ,:' ", ,L= .,' ,:1;: L f" '/'Y;J 7rV, ."--oYIL I..,:: ~ 1 k -:/,L II ,-,_,,/ J!J,:,.; ;'p' " ---.<'\ ~-'-'/~~;' *;f>-,:j::(f,".,)5'V~"oW '__ '-.-> kt f<t;7 -, I ~.:: ;>;"..,~: J:i~'/,k ~l -,@~'..)"'(./-- ~:,: ~(~~ ~ ,f! .j;; ,:,~.{:;, ."-(~ . \/V/.' ,I...,~), : ~ "(~"""'...-"'" '{-"c.': '" ,', -, b-,.'..'-' :/r;,/ /, ,~''hi ' : ""0'1<.... """'""I () __'-- ::tr,f~tJj; 'oPi/ 'J" >-'.'" . . '/~ ./ ---:, ~ ",V <:.$", . -) ',. jOliOD ( '-~0JJf$O\ . ,., ~~~~ __ ~ ~l' ): T ,\,~.~\'?&~::\,:,:'_,>\~ )./ 11~ "~ft'l "..' W~?21~ - ,.t.'~, L'~<'l-~<-~>;~;~;; ~~ij/I~a i",'/'; '\,A'~~" ~R. >.. ',\ u '" ~ ',~":.. ;.<". ,.~J1 ~:\ ",'<,,:;:/ ~o~I~JrJI,--i/ ,,(?y;; '-~,,;...-:' 'j,q-;:",,>;:;~.i1:----~-"\'{~; /1,)/ r.,'l. 4 /,~ r-;;>.:~-J~~~#"." ..-,;.~.. -. ~- I ~~ (f;~'" t. 'It ~ !c;('~ " A . 1~~,,t;Si~~~ _\;J~~ .... ,:" rrY7 ~ .. . f'\;---~~:::?;..~...t ~ It--- '~(-~ ~;..."?< lOl'/: ~~;,';' M'\~}2' D / J /'1fH r ,I,::,., 1:'2!~:i;':.'i;,' 1:.\ .~. --.' .'~'''''~ fl',' . >""""'-. .. ' ~./ ~ ....",--"..Gl:i. ':~~.:, 'i":_ ,,-', 0-...,-,," " . : . . J, / IT~_\?' .!!~ "-' , ~' ..'..:' ,'I/W" cl~11l: = '/ h""'" ~ I <-;~'::.:;::(;- "~ i--~f:---~ ~ ..;,..! ~("&""""-.\'V}'/~~~. 1lJ-/;~~~~~~~t~:F:'~~~:~~;i?p&:';:;~jJ:~;?~ ;,." .... , i\)fi I ~ 12",,-~ll~' .-~ "'f( ." d- ~/ ItOO .;. ~ . ",:;'~,r ~ ...1 I L ~~:::....~. L-' j'~:.:-J"~~~~;.'~:':;:;. J)r::: >~>'(~ ::..,j;:~~~_, ,~ [)~__ ".:. 1- ,~~~ II~ I,::'~~.~. ;t:::.,::, t:.~:;; ';:7 :,~' ", A~~_:_~ .(If'. ~......~ ~II~~\.~ ~~.,'>rc,:"v/~'-I~ . .. \ / .J. : ~ r l(.c; p.....:...;;; \ :/r!200~ '...._--JI ~.. ,,%",- - :;-\ ~/" ~\)< '--' ' ::;" If: ~'- ': --"<"1;,r:;~~;, . ~.\~ fht -. ~ - l -r:.----~.-h1'-o~.'m~~:..;~t.~~..- (f...u~~ ~ . _j.~'-~:.:c:(~~$'!::"J<..r " .. / 'J " """.. I .". . ," " , '" ' D' -' / :.'/ " .- 11- ~l,-n,''f..':'~_\).f YL \ -'~."'~:J__ CO >--=~:lf o. _,-:~.,.."r;\~;r-~~rr~il;;~'~:\'~~- ~, "~flUf/'. . ,"'>-...;;, -~ fI ..,.y-:,;- .,k'l\ '''-'./.-. /l.\ .. ,.- - "...i~'. ' t",z8",-"i"'i~II"""'GN:'J?:"""'~iI(d/ . IC 'iF " ., , , ";{,,, ~, iJ'- " I, ~ ."~,..\.' .:,'C" ~. .J' - -Q: ~ .f....(d!1~~ i ~ _ ~.._~~,- , . " 'J/ .\ _ '?" ,'-C.~ ~ili'!S~-..) . ~~ 'I .\~"~'!jt~ -;<--'VS:':c(f;f- Yi '-, ' "%~ ~ '-.:: -.-::: 0 ~'&,\ ( ~ C .- t-: 'if{'f- ~:'g:,:-- (,~~~;7 -..tj' -' --~\-9~_ ~'<PI'_'-.,c _'-":<:n~.'.> I< ~ = ~1: _, .~!v,~r ~,:;'~:;( ~ (- ~~~-,j ,~"-- ~. _'>" ~.'r:- d I IF'. ,i).' ",- /G ',--, -.' - , '0 /1'./, r ,,-,r r;:. I V. ;.; .. ",r " .--!,:.r.-: ;..7",:':-: 'i)_/( -," .. ...-.:. --1 c:;s ::::>::'";<1"- #- u'" ' , " ..[U~ -- ~ "~~ a:j;~~~, ' ~yo1 - ,-; -:_:,->:,:~ ,r:,'I!!-,/J:J'/-,4' '.. rl . ..... JOg I?y' , ,I~. II "'.-.~jr;il' ,;;'p-:~-- '. ", "V'/ .. '.. t..... ,. I ' "(II' :~ +', : -", ", /-'..--:" , ' ,"1: -, 'ROAD', ,';' '-''',,'~ ...,'-' . +~ - . #., ,.... A( r' ./1. r-...' .11 -" I II '--::.:.,- _,:,,__6'~/- ,- ~~~"\~,/i"- ~~. ,/] ~~ ~~~'7 ~~lt;:;:,~:::;2"~~'~('c-[i"~~~~ ~~-,,'\::, :_'"'\,~/~/r\'~'c '" ~.. ~t::~~~~I~':"~\'~-;:~'~')~i:\~""';'2 ..l:'../ '_'r/;~'". .~~~~.-i:~ '" l '\..,. ~'~ 1\\'., .....""' ._..S,~.t' .' ':r. &'''- ~ \1 ":'.~';'\I '\..1 ....", ~'" ."- "!~'{"~(~:Bf;}B:>';'~'-::'['':;''J~\ " ~,,"\:\ .~t ...~~.~~~~ ., _,_ ~- .... '-1: ,,~:'~.:~lt~(N~:"\"'/i.,.."":lV? WTopoQuodoCopyrlzlltC>I",DeLenl,V_oad1,ME04096 s..-Dota:USGS I 1II000n ScoIe:I:Z5,OOO DdoII,1J.O o.o.:WGSN FIGURE 1 .3 . . Mr. Karl Lowry Lowry Construction September 29,2005 Page 3 Fill Placement Fill was placed in thin loose lifts approximately 6 to 8 inches thick, brought to near optimum moisture content, and compacted to at least 90% relative compaction (ASTM DI557). Compaction was achieved by wheel rolling with a front end loader and a water truck. The maximum laboratory dry density, as determined by ASTM Dl557 Test Method A (Appendix A, Table I), was utilized as the standard for field compaction control. ' Fill Soils Soils utilized for compacted fill typically consisted of onsite dark brown silty sands (Unified Soils Classification-SM) derived from the onsite sedimentary bedrock and colluvial materials. Test results are presented in Appendix B, Table I. Cnt/Fill Transitions Rough grading operations at the site included overexcavation of the building pad to a minimum of 4 to 5-ft below natural ground and a minimum of 5-ft. beyond the building footprint, therefore, eliminating the cut/fill transition as staked by the contractor, TESTING PROCEDURES Field Density Testin2 Field density testing was performed in accordance with ASTM Test Method D2922 (nuclear gauge). Areas failing to meet the minimum compaction requirements were reworked and retested until the specified degree of compaction was achieved. The elevations and the results of the field density tests are presented in Appendix B, Results of Compaction Tests, Table 1. The approximate locations of the tests are shown on the Density Test Location Map, Plate 1. Maximnm Density Determinations Maximum Density/Optimum Moisture determinations were performed in the laboratory on representative samples of onsite soils used in the fill operations, The tests were performed in accordance with ASTM 01557-91, Test Method A. The test results, which were utilized in determining the degree of compaction achieved during fill placement, are presented in Appendix A, Table 1. THE SOILS COMPANY,'NC w. 0, No 945501.22 ~ ". ',' . - ...__.... - ..~ - ___._._ o. r I 11'"\ :'-:.':'~':::::~<::-:""-:;~\~~:"~~'''''-''---,'' I { , ~ ~' R: . -u i~ :~ . -',. I J'. : ;~l . - 'j';~ iJ,"'--~:m...... ~ ! ~ 1 ifij.!; Q :'~ , ...po.- '~' ;;l:-= Ef '............ f"ri .f>. r- ~ : !.p g GJ ("""1 ! !\:SMl1'Z i ;...........~--ItlID . ~.:a: ;' . O'l \)_~ fl , '1 '",",)J>';' ('T)" , ~.;p.. r..J ;;ID l ; I . 6~ i..J ffiWM ., 'l~ :' ,~ N tTl C) , '" '\1\<11,0 ..t,.t:I~;' ' ~ J> 1'1 'Iis.it,-. ...J:::>. Z UJ <rn1 ;' rtl if) :"-'\ ~ z ~~ !" , . : tI:t~ ~ ~ ~ ~: ; ~ ~ ;:;, Ii !l~ : i..:.,. . <.,'{:f' I' .'~ " J,. [~;..: 'F.'j .;~. ~~~~ ,"::' ;: ".; ...~ ::: i !'1 ~ .:i ~ ~ ~ ~ " 'ii ;lO ~ O::!! Il!i' ~ ~~: ~j ~ a ;f:.'~..::~ ~j' : 1"1 ~ ' II. . I::I~ l ~ a. !;' ~ ~ ;) 1 ~ r ~: . . ~ ~ ; ;n,' ... o ~ li--'~ 0>..........;) , ~ f51C I ~ ........'" ~: ~ g )>~: g .j>o. 1>~: w' <: ~ ffl: ~ i: t;l ~ 1 o , . ~. ~ ~ j ~ j ,_ ~~~- 1 i~ ! : ij .! ~ I;l i i; ! ~~,l~ ! ~:: '\ ~ f:,J ~ , f 01 "i , -d' ~ fl'l t' f'I ~I -"r ~ ~1 ~~ ~ C l ~_ .~ r-1-1 co;;o;;;!ij )>j, ~Il>~, i - ~~ I o::tlrA' ~l>ola l' 'T1~~ ~ ~ I ~(..l~!2 ~ t ;:J zco-<.... i! I n >~ ~ ~ j ~ ;;j ......:1"1 p ~5 "0 'O! I'll ~ ~] f; (5 !o , ~ '" ' I ::6 1:,0 ! 1_0t~ o'~l .'~--_!~:..;: :~. ~ \1\ ,:;::0' 0: rrJ. Z: -i' rrJ: :;::Oi l.J :;::0 (J) rrl g @~ ->: 0 ~ 3. ' ~ . ~ I~ ~ ~ '" . - ~ ~~ == . " t" o " ~ g ~oo~ '" l=! ~~ e n ~.S I'i~a 8 ~ ~ ~ ~ ~ ~~~n Sl 8 ~ . ~~ 51 n ' ~ . 9 ~ ~ ~ ~ ('> ; ~ .. ~ . ~.~~ 'G~ ;::~~ ~~ I ,~~ ~~- a'~ if'~ ;~~[;l;~ ~i;~ ll- " '. .. ;.r ..... .:..' - I (,. .- _'"_'_"__""__...___',~ ~~.,~..~~u..~..__ _~__... ' ~. ~ CJ EJ --... ------- --... "- '''-, ',,- , , '-, ''-, " , , , , , "- , , "- , , "- , , " . , , " , , . , , \ , , \ , , \ , \ \ ~, .,~ ,.Ii . ' ~ -, : 4 !. ~ ~ \ , \ I"~~ ~ i I~ ~I~ U ::;0 ~~!\ ~ f1l f1l , ii'~ :1111 i n~~ I I ('T) AJ () ~ai1 8 ~ a)>- ;;e 0 ~ g:;; g: 0 = b~~ s !Q U) ;r . I m > II rl~ .. .~~~ . I G 0 .. a;i>- Z C) :!:! , z i ~..~ ~ i 8 :::tJ ~:i j ,~11 ~ ' ~ . z () )> . U , -.j 0 0 I i i ~ 0 i2 z z ~j~ 11 fIl -,j C) ;;; ;r .~ )Q g ~ U 1 . )> z Ir~ fIt; HIml;: !p: "IUl: ~fiHitP' r i~f; $ in: 1: fmr 11': 1m: illw lig'!; rUt; -~~~" tlt~r. i!l~! l!lImnlll! I~ll Wli!!Il ~ illl" ~iil ~I~ll :ijtlmf l!!~ n~, l'!ll ~f;~ ~ j P n 1 ijl j~~!,~! l~!i ~IUllmn ~ w,'jl~ 11~1 f.lli~ ll~! ~,!ll ~~ ~~ I, j'!i 1,',11 i !i~ II i f- hr ~ h J .th.w-i I II ..U !~, ~.j r ti! I ; ~.' '1., 'I :!l. ,:1 : ifj u .Lj q 1 . J ii~ Pili 1 q " t i' j! 'f! ~l W i k'!i i1 ~:~ . . ... --- .- .....--.--- ,_.~-- . . , Mr, Karl Lowry i Lowry Construction , September 29,2005 , Page 4 RECOMMENDATIONS ! Expansion Testinl!: I Expansion index testing was performed on a representative sample of the upper 3-ft of the earth , materials exposed at the pad surface, The test results yielded an expansion index of 29, which indicates a low expansion potential (21 to 50 Table l8-I-B, 2001 CBC), Test results are presented , in Appendix A, Table II. . elasticity Index Testinl!: Plasticity Index testing was performed on a sample of the upper 3-ft of the earth materials exposed , at the pad surface that yielded an expansion index greater than 20 (per 2001 CBC). The results yielded a plasticity index of 0.17, Test results are presented in Appendix A, Table III. : Soluble Sulfate Content It is anticipated that, from a corrosivity standpoint, Type II Portland Cement can be used for , construction. A representative sample of the earth materials exposed on the pad surface has been , obtained for testing. Owing to the time constraints of this report, soluble sulfate test results were not available at the completion of this report, which will be forwarded as an addendum once they , are received. Babcock & Sons, Laboratory of Riverside, California is performing the soluble sulfate testing. Slope Construction Cut slopes were constructed to a maximum height of approximately l8-ft at a 2:1 (horizontal:vertical) slope ratio, We anticipated the cut slopes constructed at a 2: I slope ratio to a maximum height of 30-ft to be both surficially and grossly stable. Spread Foundation It is anticipated that the foundation elements should be founded entirely in compacted fill materials, T.H.E. Soils Company, Inc, should perform a footing inspection, prior to placement of reinforcement, to insure the proposed footing excavations are in conformance with the job specifications. The recommendations presented in the referenced report (WAC, 2004) should be adhered to during site development and are reiterated in the following sections, A conventional shallow foundation system is considered suitable for planned residential and ancillary structures, Type II cement is acceptable for construction, THE SOILS COMPANY, INC. W, O. No. 945501.22 " . . , Mr. Karl Lowry Lowry Construction , September 29, 200S Page S . Foundations mav be desiened based upon the followine values: Allowable Bearing: 1,600 lbs./sq. ft Lateral Bearing: 147 lbs./sq. ft. per foot of depth to a maximum I,SOO lbs./sq, ft, Sliding Coefficient: 0.23 Allowable bearing may be increased to 20% of the above designated value for each additional foot of depth, up to three times the designated value additionally, an increase of 1/3 shall be permitted when considering load combinations, including wind or earthquake loads, as permitted by 2001 CBC Section 1612.3 ,2. Lateral bearing may be increased by the designated value for each additional foot of depth not to exceed I,SOO psf, per 2001 CBC Table 18-I-A, Modified, Other Desien Recommendations: Footing Depth Exterior - l2-inches below lowest adjacent grade (in approved compacted fill materials) Interior - 12-inches below lowest adjacent grade (in approved dense compacted fill materials) Footing Width Exterior - 12-inches minimum for one-story, IS-inches minimum for 2-story Interior - 12-inches minimum for one and IS-inches for 2-story, respectively. Footing Reinforcement Exterior & interior - all continuous: four No.4 bars, two near the top, two near the bottom for exterior and two No.4 bars one near the top and one near the bottom for interior, Concrete Slabs - slab thickness: 4-inches reinforced with No.3 bars at l6-inch on center each way or approved equivalent. Under-Slab Treatment Living Areas - 6mil visqueen; cover with at least 2 inches of sand, Sub-grade soils should be presoaked to contain at least optimum moisture content immediately prior to placing visqueen and to be verified by the soils engineering consultant. The sand cover should be moistened prior to placing concrete, Grade Beam - A grade beam reinforced continuously with the garage footings should be constructed across all garage entrances, tying together the ends of the garage footings. This grade beam should be embedded at the same depth as the adjacent perimeter footings. THE SOILS COMPANY,INC. W, 0, No 945501.22 L . . Mr, Karl Lowry Lo'WTY Construction September 29,2005 !Page 6 : Garage Slab - Optimum moisture content in sub-grade soil verified by the soils engineering consultant. I Fireplace Footings - fireplace footings shall have a minimum embedment depth of 24-inches measured from the lowest recommended adjacent grade founded into competent soil and should be an integral part of the building foundation system. Fireplace slabs shall be treated in the same manner as the living area slabs, Prior to pouring, footings should be re-moistened and field approved by the project soils engineering consultant or his representative. The settlement of properly designed and constructed foundations supported on approved earth I materials, carrying maximum anticipated vertical loadings, are expected to be within tolerable ; limits. Estimated total and differential settlements should be no more than % and Y2-inch, I respectively. Resistance to Lateral Loads Resistance to lateral loads can be restrained by friction acting at the base of foundations and by passive earth pressure. Nle maximum lateral passive earth pressure is recommended not to exceed 1,500 pounds. For design, lateral earth pressures of local soils when used as level backfill may be estimated from the following equivalent fluid density: Active: 48 pcf Passive: 200 pcf At Rest: 69 pcf l!Jtilitv Trench Backfill Utility trench backfill should be compacted to a minimum of 90% of the maximum dry density, as determined by the ASTM 1557 test method, It is our opinion, that utility trench backfill consisting of on-site or approved sandy soils can best be placed by mechanical compaction to a minimum of 90% of the maximum dry density, All trench excavations should be conducted in accordance with Cal-OSHA standards, as a minimum, Fill materials should be placed in 6 to 8-inch lifts, brought to near optimum moisture content and compacted to a minimum of 90% of the maximum laboratory dry density, as determined by the ASTM 1557 test method, No rocks larger than 6-inches in diameter should be used as fill materiaL Rocks larger than 6-inches should either be hauled off-site or crushed to a suitable dimension and used as fill materiaL THE SOILS COMPANY, INC. w. O. No. 945501.22 8 . . Mr, Karl Lowry Lowry Construction September 29, 200S Page 7 Surface Drainal!:e Surface drainage should be directed away from foundations of buildings or appurtenant structures, All drainage should be directed toward streets or approved permanent drainage devices. Where landscaping and planters are proposed adjacent to foundations, subsurface drains should be provided to prevent ponding or saturation offoundation~ by landscape water. Construction Monitorinl!: Continuous observation and testing, by T.H.E. Soils Company, Inc. is essential to verify compliance with recommendations and to confirm that the geotechnical conditions encountered are consistent with the recommendations of this report. T.H.E, Soils Company, Inc. should conduct construction monitoring, at the following stages of construction: . During excavation of footings for foundations. . During fill placement. . Eluring trench backfill operations. SUMMARY Our description of rough grading operations, as well as observations and testing services, were limited to those' rough grading operations performed between September 2, 200S and September 9, 200S and observed and tested by our field personnel. The conclusions and recommendations contained herein have been based upon our observation and testing as noted, It is our opinion, the work performed in the areas denoted has generally been accomplished in accordance with the job specifications and the requirements of the regulating agencies. No conclusions or warranties are made for the areas not tested or observed. This report is based on information obtained during rough grading. No warranty as to the current conditions can be made. This report should be considered subject to review by the controlling authorities, LIMITATIONS This report is issued with the understanding that it is the responsibility of the owner, or his representative, to ensure that the information and recommendations contained herein are brought to the attention of the project architect and engineer. The project architect or engineer should incorporate such information and recommendations into the plans, and take the necessary steps to see that the contractor and subcontractors carry out such recommendations in the field. This firm does not practice or consult in the field of safety engineering. We do not direct the contractor's operations, and we cannot be responsible for other than our own personnel on the site; therefore, the safety of others is the responsibility of the contractor. The contractor should notify the owner if he considers any of the recommended actions presented herein to be unsafe, THE SOILS COMPANY, INC. W 0 No, 945501.22 '\ Mr. Karl Lowry Lowry Construction September 29, 200S Page 8 . . This firm did not provide any surveying services at the subject site and does not represent that the building locations, contours, elevations, or slopes are accurately depicted on the plans. The findings of this report are valid as of the report date, However, changes in the conditions of a pr9perty can occur with the passage of time, whether due to natural processes or the works of man on this or adjacent properties, In addition, changes in applicable or appropriate standards may occur, whether they result from legislation or the broadening of knowledge. Accordingly, the [mdings of this report may be invalidated wholly or partially by changes outside our control. Therefore, this report is subject to review and revision as changed conditions are identified, This opportunity to be of service is sincerely appreciated, If you have any questions, please call. Very truly yours, P.e~ B oject Geologist rnU.E. Soils Company, Inc. . Reinhart, RCE 23464 Civil Engineer, Expires 12-3l-0S :JPF/JTR/JRH:jek ACCOMPANYING MAPS AND APPENDICES Location Map - Figure I Density Test Location Map (20-scale) - Plate I Appendix A - Laboratory Test Results Appendix B - Results of Compaction Tests THE SOILS COMPANY, INC. W,o. No, 945501.22 \0 THE SOILS COMPANY, INC. . APPENDIX A Laboratory Test Results . w. O. No. 94550122 \\ . . TABLE I Maximum Density/Optimum Moisture 0/0 Description Lbs/Fe Moisture I Medium Brown Sand 132.5 8.2 2 Medium Brown Silty Sand 126.0 11.0 3 Dark Brown Silty Sand 128,2 9.5 I TABLE II I EXPANSION INDEX TEST LOCATION EXPANSION INDEX EXPANSION POTENTIAL , Pad Surface 0-3-ft 29 Very Low TABLE III Plasticity Index , TEST LOCA nON PI , Pad Surface 0-3-ft 0.17 , THE SOILS COMPANY, INC. w, 0, No, 94550122 \Z-- TilE SOILS COMPANY,INC . APPENDIX B Results of Compaction Tests . W O. No. 945501.22 \,2> . . TABLEt RESULTS OF COMPACTION TESTS Lowry Construction DATE: September 2005 .W.O. No. 945501.22 Test Test Elevation Moisture Unit Dry Relative Soil Test Location No. Date Depth Content Density Compaction Type (Feet) (%) (pCF) (%) 1 9-02-05 1128 11.1 120.1 94N-NG 3 See Plate 1 2 9-02-05 1130 12.2 119.0 93N 3 " 3 9-02-05 1132 11.4 119.7 93N 3 " 4 9-07-05 1134 12.9 120.5 94N 3 " 5 9-07-05 1136 12.7 119.2 93N 3 " 6 9-09-05 1137.5 10.7 116.2 91N 3 " 7 9-09-05 1132 11.3 115.6 92N-NG 2 " 8 9-09-05 1134 11.0 117.1 91N 3 " 9 9-09-05 1136 11.8 116.6 91N 3 " 10 9-09-05 1138 10.5 119.0 90N 1 " 11 9-09-05 FG 10.2 119.9 90N 1 " 12 9-09-05 FG 11.1 116.5 91N 3 " 13 9-09-05 FG 11.0 116.5 91N 3 " 14 9-09-05 FG 10.9 117.0 91N 3 " SEE PLAN FOR TEST LOCATIONS SC - Sand Cone ASTM 01556; DC-Drive Cylinder ASTM D2937; Ii-Nuclear ASTM 3017; NG-Natural Ground + 85% = Passing Test; FG-Finish Grade **TEST FAILED, SEE RETES TilE SOILS COMPANY, INC. w. O. No. 945501.22 '^