HomeMy WebLinkAboutTract Map 3883 Lot 467 Field Density Testing . " . REPORT of OBSERVATION and FIELD DENSITY TESTING for RESIDENTIAL GRADING Lot 467; TR 3883 APN 919-280-017 Log #: LD 99-215GR November 5, 1999 Prepared for: Mr. Richard Zinsmann 7488 San Reno Tr. Yucca Valley, CA 92284 Phone: 760/365-3638 Prepared by: Gunvant Thakkar, P.E. 45712 Classic Way Temecula, California 92592 (909) 676-7541 ~~ \...en 4C. 1 RECEIVED NOV 1 5 1999 CITY OF TEMECULA ENGINEERING DEPARTMENT \ "- . . GUNVANT THAKKAR, PROFESSIONAL ENGINEER 45712 Classic Way, Temecula, California 92592 909)676-7541 November 5, 1999 RECEIVED NOV 1 5 1999 CITY OF TEMECULA ENGINEERING DEPARTMENT Mr. Richard Zinsmann 7488 San Reno Tr. Yucca,Valley, CA 92284 Phone: 760/365-3638 Project: Compaction Testing Report Lot 467; TR 3883 APN 919-280-017 Log #: LD 99-215GR Dear Mr. Zinsmann: In accordance with your request, we have prepared this compaction report for the subject property. The report represents a summary of the observations and compaction testing of the fill placed on the proposed grading pad. Field testing and observations indicate the compaction of the soil was performed properly. The soil should perform satisfactorily for the expected usage. The included findings and recommendations have been derived in accordance with generally accepted professional principles and practices in the fields of soil mechanics and foundation engineering. This warranty is in lieu of all other warranties, either expressed or implied. 2- . . INTRODUCTION In accordance with your request, tests have been performed on the fill placed on the rough graded residential pad. The excavation, fill placement, compaction and testing associated with this phase of the grading was performed during October 28 through November 4, 1999. This report presents a summary of the testing services provided. PROJECT DESCRIPTION The ,site will have a single family residence with attached garage constructed on it with associated landscaping and access drive. These structure could consist of a one or two story, wood framed residence founded on a continuous perimeter footings foundation system. GRADING PROCEDURES The observations and test results indicated that the grading was performed in the method consistent with the project specifications. All areas to receive fill were stripped and cleared of vegetation and soft soil prior to placement of soil fill. Keying and benching into natural ground was completed in general compliance with the Uniform Building Code, Appendix Chapter 33. The'minimum acceptable degree of compaction content was 90 percent of the maximum density. FlEW DENSITY TESTING Field density testing was performed in accordance with ASTM D1556-64 (Sand Cone Method). The results of the field density tests are presented in Table I of this report. The approximate location of the tests are shown on the Plot Plan, Plate 1. MAXIMUM DENSITY DETERMINATIONS Maximum density 1 optimum moisture determinations were made from representative samples of on-site soils used in the fill operations. The tests were performed in accordance with ASTM D1557- '78 Method. ..3 '" . . LIMITATIONS The findings and recommendations of this report were prepared in accordance with contemporary principles and practices in the field of geotechnical engineering. No other warranty or guarantee is either expressed or implied. Only a portion of the subsurface soils and conditions were evaluated or observed and the conclusions are based upon an interpretation of the soils conditions encountered in the field tests. Conclusions are also based on the assumption that these findings do not vary appreciably in the adjacent areas. However, minor variations may occur: should soil conditions significantly different be encountered in the future, an assessment of the impact on subsequent recommendations should be made. All futtlre grading and fill placement should be performed under the inspection and testing of a registered civil engineer. SUMMARY Our:description of grading and backfill operations, as well as testing services, were limited to those grading operations performed during October 28 through November 4, 1999. The conclusions and recommendations contained herein have been based upon our observation and testing as noted. It is our .opinion that the work performed in the areas denoted has generally been accomplished in accordance with U.B.C. Appendix Chapter 33 specifications. No conclusions or warranties are made for areas not tested or observed. . ,I} / /. . . GUNVANT THAKKAR, PROFESSIONAL ENGINEER 45712 Classic Way, Temecula, California 92592 (909) 676-7541 Mr. Zinsmann: Maximum Density Optimum Moisture Content (pcf) 1%) 129.0 10.5 Eleva- Max.Dry Water Dry Relative Method Tion Density Content Density Com pac- (Feet) (pcf) (%) (pcf) Tion (%) 1. Key 129.0 10.5 117.4 91 SC 2. Key 129.0 10.2 118.7 92 SC 3. 4 129.0 9.8 119.9 93 SC 4. 6 129.0 10.2 121.3 94 SC 5. 8 129.0 9.9 123.8 96 SC 6. 10 129.0 10.1 122.5 95 SC 7. FS 129.0 10.3 121.3 94 SC 8. FS 129.0 10.2 118.7 92 SC 9. FS 129.0 9.9 119.9 93 SC 10. FS 129.0 9.8 118.7 92 SC ~ ~ . . l~, J. b(rS1'/IVQ !_L_. it oeL Ilf'/ ROllO -P..~~ ~~ PAtlEJ) JeOAf) IJIlY J /.2? Ct1HC: onv./!. IlPP/{(J4Of FEJ! Glry OF I' It rE.111er:UlA S7!). P4'~ "0. ?tJ7 ~ " , , ::1 1'/ &4.;1'1&1'/1 __ ~.."~,-,,_..-4,, /.D~._,. >>: '~''-' o!: - - - II :'.--:--:-..~--- ~ _ ,... :.t- , ' I i, r: . 'I "''".-. . _.... , I f:I C.UT tur& It: : I , , I 11 I , '- ~_.--- '-"., " ~ ;, -'. - '. ., t -~" - ( I I I l, '~L:- \., /~<"~, ~ . - ~~. '~ / - I ~ r 1 I \ ' , I~ I'll , " , , , /...., I' .~. ~~' ,r . 1~ " ,I ~ l:' ., w . ~ 'I I I . .~~ n; ~, ,. ~ . : PPO ElE .. 1172 ... .; tC..-: .12>7!!: ~ , :\:f\O . ' '" , ~ trlUl GU ~t'Tr<:""I'I.t- It. LEGEND APPROXIMATE TEST LOCATION DATE: ~Y4q TEST LOCATION PLAN '5' ..;. . DATE: \'IJ ~ ),. !h9lYc. a I' IS . '5i Q( ClJt.lF()IeNdl . PRtJJEcr S'rTE J2t> . SITE LOCATION PLAN ~. ("'- ....,-,-~ c' I ,.., ) /t I '.--G.....l.-'"'-'" G.