HomeMy WebLinkAboutTract Map 3929 Lot 254 Observation & Field Density Testing . . REPORT of OBSERVATION and FIELD DENSITY TESTING for BARN & RECREATIONAL PADS Lot 254; TR 3929 30135 Via Monterey Permit No. 97-087 GR " February 1, 2000 Prepared for: Mr. Michael Napolitano 30135 Via Monterey Temecula, CA 92591 909/694-3524 Prepared by: 1 Gunvant Thakkar, P.E. 45712 Classic Way Temecula, California 92592 909/676-7541 ~ .3o,z.tt \..0,23\ \ . . GUNVANT THAKKAR, PROFESSIONAL ENGINEER 45712 Classic Way, Temecula, California 92592 909)676-7541 February 1, 2000 -. Mr. Michael Napolitano 30135Via Monterey Temecula, CA 92591 909/694-3524 Project: Compaction Testing & Report Lot 254; TR 3929 30135 Via Monterey Permit No. 97-087 GR In accordance with your request, we have prepared this compaction report for the subject property. The report represents a summary of compaction testing of the fill placed on the barn and recreational pads. Field testing and observations indicate the compaction and grading of the soil was performed properly. The soil should perform satisfactorily for the expected usage. The included findings and recommendations have been derived in accordance with generally accepted professional principles and practices in the fields of soil mechanics and foundation engineering. This warranty is in lieu of all other warranties, either expressed or implied. 7-- . . INTRODUCTION In accordance with your request, tests have been performed on the fill placed on the barn and recreational pads. The compaction testing associated with this phase of the grading was performed during January 10 through January 22, 2000. This report presents a summary of the testing services provided. PROJECT DESCRIPTION The residence will have a barn and recreational pad constructed on it in the back portion of the property, with associated landscaping and access drive. GRADING PROCEDURES The observations and test results indicated that the grading was performed in the method consistent with the U.B.C. as amended by Ordinance 457. The minimum acceptable degree of compaction was 90 percent of the maximum density. FIELD DENSITY TESTING Field density testing was performed in accordance with ASTM D1556-64 (Sand Cone Method). The results of the field density tests are presented in Table I of this report. The approximate location of the tests are shown on the Plot Plan, Plate 1. MAXIMUM DENSITY DETERMINATIONS Maximum density I optimum moisture determinations were made from representative samples of on-site soils used in the fill operations. The tests were performed in accordance with ASTM D1557- 78 Method. ':? . . LIMITATIONS The findings and recommendations of this report were prepared in accordance with contemporary principles and practices in the field of geotechnical engineering. No other warranty or guarantee is either expressed or implied. Only a portion of the subsurface soils and conditions were evaluated or observed and the conclusions are based upon an interpretation of the soils conditions encountered in the field tests. Conclusions are also based on the assumption that these findings do not vary appreciably in the adjacent areas. However, minor variations may occur: should soil conditions significantly different be encountered in the future, an assessment of the impact on subsequent recommendations should be made. All future grading and fill placement should be performed under the inspection and testing of a registered civil engineer. Due ,to periodic site inspections and testing, footing excavations should be inspected by a registered civil engineer prior to concrete placement to verify proper embedment entirely into competent soils. SUMMARY Our description of testing services, were limited to January 10 through January 22,2000. The conclusions and recommendations contained herein have been based upon our observation and testing'as noted. RECOMMENDATIONS FOR GRADING 1. The soil should perform satisfactorily for the expected usage. 2. /c>~ A, DATE: . . "{ _-l 2.-\-clD SITE LOCATION PLAN <( Z UJ a: UJ U) ! r I > PLATE: 7- }.J~-POLITI'rNO -5 . . I I / / / / ~.. .;. ,.~.' ..~_~:~~_._,_.,...~~~____.__.__.....o---"':;'-:-- _~~., __".\v _~5 ~. AI '~:~:-' I. '.'- '\:, ^, .~.,;.;,.;---.. ....~'r .~ ~.":--. __ _._ 'l!... _ \ \ ',"- .~~~:,",~"""..,,.:~ \ G~S~:::~~~~F.~mJN' pM- ~I'. / I FAD .Ei:.6.~J,5:'.{..... 1 i i .' ".. -r- . . _.;:_, /,,',;,} .-<tll " l7~;:- ... -.l;"." ..> 8 LEGEND APPROXIMATE TEST LOCATION DATE: 2-1-00 TEST LOCATION PLAN PLATE: JVf1f!jLT-T/i-fJ U (p . . GUNVANT THAKKAR, PROFESSIONAL ENGINEER 45712 Classic Way, Temecula, California 92592 (909) 676-7541 Mr. Napolitano , ' Maximum Density Optimum Moisture Content (pcf) (%) 129 10.0 Max.Dry Elevation Density (pcf) Water Content (%) Dry Density (pcf) Relative Method Compac- tion (%) 1. 1156 129 10.2 117.4 91 SC 2. 1157 129 10.5 118.7 92 SC 3. 1158 129 10.2 117.4 91 SC 4. 1158 129 10.3 118.7 92 SC 5. 1159 129 9.8 120.0 93 SC 6. 1159 129 9.7 118.7 92 SC 7. 1160 129 9.9 117.4 91 SC 8. 1150 129 10.1 118.7 92 SC 9. 1150 129 10.5 120.0 93 SC 10. 1152 129 11.0 118.7 92 SC 11. 1153 129 11.1 117.4 91 SC 12. 1154 129 10.9 118.7 92 SC 13. 1155 129 10.5 120.0 93 SC 14. 1155 129 10.2 118.7 92 SC 15. 1155 129 9.9 117.4 91 SC '\