Loading...
HomeMy WebLinkAboutTract Map 9833 Lot 2-5 Geotechnical Report & Compaction Results I I I I I I ,I I I I I I I I I I I I "I ~iEnGEN ~CORPORATION ~~-Cj~6t< /l( qf? 33 nr-S- :August 2, 2006 IMr. Paul Gupta ,41636 Enterprise Circle North ITemecula, California 92590 (951) 296-3397/ FAX (951) 296-3398 :Attention: Mr: Paul Gupta -Regarding: GEOTECHNICAL REPORT AND COMPACTION TEST RESULTS POST GfW)ING OPERATIONS Goyal and Gupta Residences APNs 959-010-001 and 959-010 -004, Lots 2 & 5, Tract 9833 Jedediah Smith Road and Calle de Vellardo - City of T emecula, Riverside County, California Project Number: T3065-C References: 1. EnGEN Corporation, Gentechnical Report and Compaction Test Results, Rough Grading Operations, Goyal and Gupta Residences, Assessor's Parcel Numbers: 959-010-001 and 959-010-004, Lots 2 and 5 of Tract 9833, Jedediah Smith Road and Calle de Velardo, City of Temecula, County of Riverside, California, Project Number: T3065-C, dated March 17,2005. 2. Bratene Construction & Engineering, Precise Grading, Erosion and Sediment Control Plans, Goyal and Gupta Residence, Lots 2 and 5 of Tract Map No. 9833, Jedediah Smith Road, Temecula, California, plans dated November 5, 2004. Dear Mr. Gupta: . In accordance with your request arid signed authorization, EnGEN Corporation has performed field observations, sampling, and in-place density testing on an on-call basis at the above referenced site from January 25, 2006 through July 25, 2006. The following testing was performed during post grading operations: . Driveway Subgrade . Driveway Approach Subgrade . Driveway Aggregate Base . 'Gutter Subgrade Maximum dry density/optimum moisture content tests were conducted on samples of the native materials and imported aggregate base. The tests were performed in general accordance with ASTM D 1557-02 procedures. The results are presented in the Appendix of this report. Relative compaction testing was performed. in general accordance with procedures. for determining in-place density and moisture content; respectively, using nuclear density gauge \ .2S759 Jefferson AvenuE', ,\1urriN;l, Cllifornia 0256) -I'hnne: i9~ 1: l;.HSnDO. f"", .:',lS 1) 8J.19001 I I I I I I I I I I I I I I I I I I -I Gupta Residence Project Number:T3065-C August 2006 Page 2 .equipment. Test results are presented in the Appendix and the approximate test locations are :shown on the site plan, also presented in the Appendix of this report. In-place density test results indicate a minimum of 90 percent relative compaction for the .driveway subgrade and the curb and gutter subgrade areas of the site, and 95 percent relative compaction for the approach subgrade and in the aggregate base. The native soils encountered on the site consisted of Light Brown Silty Sand. Import earth materials consisted :of Brown aggregate base. Based on the observations and tests performed in the areas noted as test locations, the post ,grading operation has been completed in accordance with the grading code of the City of Temecula. Thank you for the opportunity to provide these services. If you should have any questions regarding this report, please do not hesitate to contact this office at your convenience. Respectfully submitted, EnGEN Corporation Distribution: (4) Addressee FILE: EnGEN/ReportinglCfT3065-C Goyal and Gupta Residence EnGEN Corporation 1-- I I I I I I I I I I I I I I I I I I I Gupta Residence Project Number: T3065-C Page 1 APPENDIX: TEST RESULTS ~ EnGEN Corporation I I I I I I I I I I I I i I 'I I I 1 I ~I Gupta Residence Project Number: T3065-C Page 1 FIELD TEST RESULTS (Summary of Field In-Place Density Test Results) (Nuclear Gauge Test Method) (S. G.) = Subgrade I (F. G.) = Finish Grade Test Test Depth Max Moisture Dry Relative Required No. Date Test locations Elevation Soil Type Density Content Density Compaction Compaction (2005) (FT) (PCF) (%) (PCF) (%) (%) 1 01'25 Driveway SG A2 127.2 7.8 124.0 97.5% 90.0% 2 01'25 Driveway SG A2 127.2 7.6 122.5 96.3% 90.0% 3 01;25 Driveway SG A2 127.2 7.6 123.8 97.3% 90.0% 4 01'25 Driveway SG A2 127.2 6.8 121.8 95.8% 90.0% 5 01-25 Driveway SG A2 127.2 8.1 123.9 97.4% 90.0% 6 01'25 Curb and Gutter SG A2 127.2 10.6 118.3 93.0% 90.0% 7 01,25 Curb and Gutter SG A2 127.2 10.4 118.3 93.0% 90.0% 8 01'25 Driveway SG A2 127.2 9.9 118.8 93.4% 90.0% 9 02'02 Curb and Gutter SG A2 127.2 7.2 119.0 93.6% 90.0% 10 02,0~ Curb and Gutter SG A2 127.2 7.7 117.5 92.4% 90.0% 11 02'02 Driveway SG A2 127.2 7.6 121.1 95.2% 90.0% 12 02-02 Curb and Gutter SG A2 127.2 5.5 118.3 93.0% 90.0% 13 02-02 Curb and Gutter SG A2 127.2 7.8 124.0 97.5% 90.0% 14 02.02 Curb and Gutter SG A2 127.2 8.5 122.8 96.5% 90.0% 15 02-02 Curb and Gutter SG A2 127.2 8.5 123.8 97.3% 90.0% 16 02-02 Curb and Gutter SG A2 127.2 7.4 116.4 91.5% 90.0% 17 02-02 Curb and Gutter SG A2 127.2 8.5 110.7 87.0% 90.0% 18 02-27 Retest #18 SG A2 127.2 5.7 117.5 92.4% 90.0% 19 02-27 Driveway SG A2 127.2 6.1 124.4 97.8% 90.0% 20 03-08 Driveway Base C1 132.1 5.8 128.0 96.9% 95.0% 21 03-08 Driveway Base C2 132.1 5.5 128.7 97.4% 95.0% 22 03-08 Oriveway Base C3 132.1 6.7 127.4 96.4% 95.0% 23 03-08 Driveway Sase C4 132.1 6.4 128.3 97.1% 95.0% 24 03-08 Driveway Base C5 132.1 6.5 126.7 95.9% 95.0% 25 03-08 Driveway Base C6 132.1 6.1 127.1 96.2% 95.0% 26 07-25 Dr. Approach Jedediah Smith SG A2 127.2 7.2 121.5 95.5% 95.0% 27 07-25 Dr. Approach Jedediah Smith SG A2 127.2 6.8 121.4 95.4% 95.0% ~ EnGEN Corporl;\tion .... II I I I I I I I I I I I , I I !I I I I 1 Gupta Residence Project Number: T3065-C Page 1 SUMMARY OF OPTIMUM MOISTURE CONTENT MAXIMUM DRY DENSITY RELATIONSHIP TEST RESULTS ASTM D 1557-02 Maximum Optimum Soil Description (USCS Symbol) Soil Type Dry Density Moisture (PC F) Content (%) Silty Sand Light Brown (SM) A2 127.2 9.4 Sandy Gravel Brown (GW) C1 132.1 7.4 s EnGEN Corporation