:August 2, 2006
IMr. Paul Gupta
,41636 Enterprise Circle North
ITemecula, California 92590
(951) 296-3397/ FAX (951) 296-3398
:Attention: Mr: Paul Gupta
-Regarding: GEOTECHNICAL REPORT AND COMPACTION TEST RESULTS
POST GfW)ING OPERATIONS
Goyal and Gupta Residences
APNs 959-010-001 and 959-010 -004, Lots 2 & 5, Tract 9833
Jedediah Smith Road and Calle de Vellardo -
City of T emecula, Riverside County, California
Project Number: T3065-C
References: 1. EnGEN Corporation, Gentechnical Report and Compaction Test Results,
Rough Grading Operations, Goyal and Gupta Residences, Assessor's
Parcel Numbers: 959-010-001 and 959-010-004, Lots 2 and 5 of Tract
9833, Jedediah Smith Road and Calle de Velardo, City of Temecula,
County of Riverside, California, Project Number: T3065-C, dated March
17,2005.
2. Bratene Construction & Engineering, Precise Grading, Erosion and
Sediment Control Plans, Goyal and Gupta Residence, Lots 2 and 5 of Tract
Map No. 9833, Jedediah Smith Road, Temecula, California, plans dated
November 5, 2004.
Dear Mr. Gupta: .
In accordance with your request arid signed authorization, EnGEN Corporation has performed
field observations, sampling, and in-place density testing on an on-call basis at the above
referenced site from January 25, 2006 through July 25, 2006.
The following testing was performed during post grading operations:
. Driveway Subgrade
. Driveway Approach Subgrade
. Driveway Aggregate Base
. 'Gutter Subgrade
Maximum dry density/optimum moisture content tests were conducted on samples of the native
materials and imported aggregate base. The tests were performed in general accordance with
ASTM D 1557-02 procedures. The results are presented in the Appendix of this report.
Relative compaction testing was performed. in general accordance with procedures. for
determining in-place density and moisture content; respectively, using nuclear density gauge
\
.2S759 Jefferson AvenuE', ,\1urriN;l, Cllifornia 0256) -I'hnne: i9~ 1: l;.HSnDO. f"", .:',lS 1) 8J.19001
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
-I
Gupta Residence
Project Number:T3065-C
August 2006
Page 2
.equipment. Test results are presented in the Appendix and the approximate test locations are
:shown on the site plan, also presented in the Appendix of this report.
In-place density test results indicate a minimum of 90 percent relative compaction for the
.driveway subgrade and the curb and gutter subgrade areas of the site, and 95 percent relative
compaction for the approach subgrade and in the aggregate base. The native soils
encountered on the site consisted of Light Brown Silty Sand. Import earth materials consisted
:of Brown aggregate base.
Based on the observations and tests performed in the areas noted as test locations, the post
,grading operation has been completed in accordance with the grading code of the City of
Temecula.
Thank you for the opportunity to provide these services. If you should have any questions
regarding this report, please do not hesitate to contact this office at your convenience.
Respectfully submitted,
EnGEN Corporation
Distribution: (4) Addressee
FILE: EnGEN/ReportinglCfT3065-C Goyal and Gupta Residence
EnGEN Corporation
1--
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Gupta Residence
Project Number: T3065-C
Page 1
APPENDIX:
TEST RESULTS
~
EnGEN Corporation
I
I
I
I
I
I
I
I
I
I
I
I
i I
'I
I
I
1
I
~I
Gupta Residence
Project Number: T3065-C
Page 1
FIELD TEST RESULTS
(Summary of Field In-Place Density Test Results)
(Nuclear Gauge Test Method)
(S. G.) = Subgrade I (F. G.) = Finish Grade
Test Test Depth Max Moisture Dry Relative Required
No. Date Test locations Elevation Soil Type Density Content Density Compaction Compaction
(2005) (FT) (PCF) (%) (PCF) (%) (%)
1 01'25 Driveway SG A2 127.2 7.8 124.0 97.5% 90.0%
2 01'25 Driveway SG A2 127.2 7.6 122.5 96.3% 90.0%
3 01;25 Driveway SG A2 127.2 7.6 123.8 97.3% 90.0%
4 01'25 Driveway SG A2 127.2 6.8 121.8 95.8% 90.0%
5 01-25 Driveway SG A2 127.2 8.1 123.9 97.4% 90.0%
6 01'25 Curb and Gutter SG A2 127.2 10.6 118.3 93.0% 90.0%
7 01,25 Curb and Gutter SG A2 127.2 10.4 118.3 93.0% 90.0%
8 01'25 Driveway SG A2 127.2 9.9 118.8 93.4% 90.0%
9 02'02 Curb and Gutter SG A2 127.2 7.2 119.0 93.6% 90.0%
10 02,0~ Curb and Gutter SG A2 127.2 7.7 117.5 92.4% 90.0%
11 02'02 Driveway SG A2 127.2 7.6 121.1 95.2% 90.0%
12 02-02 Curb and Gutter SG A2 127.2 5.5 118.3 93.0% 90.0%
13 02-02 Curb and Gutter SG A2 127.2 7.8 124.0 97.5% 90.0%
14 02.02 Curb and Gutter SG A2 127.2 8.5 122.8 96.5% 90.0%
15 02-02 Curb and Gutter SG A2 127.2 8.5 123.8 97.3% 90.0%
16 02-02 Curb and Gutter SG A2 127.2 7.4 116.4 91.5% 90.0%
17 02-02 Curb and Gutter SG A2 127.2 8.5 110.7 87.0% 90.0%
18 02-27 Retest #18 SG A2 127.2 5.7 117.5 92.4% 90.0%
19 02-27 Driveway SG A2 127.2 6.1 124.4 97.8% 90.0%
20 03-08 Driveway Base C1 132.1 5.8 128.0 96.9% 95.0%
21 03-08 Driveway Base C2 132.1 5.5 128.7 97.4% 95.0%
22 03-08 Oriveway Base C3 132.1 6.7 127.4 96.4% 95.0%
23 03-08 Driveway Sase C4 132.1 6.4 128.3 97.1% 95.0%
24 03-08 Driveway Base C5 132.1 6.5 126.7 95.9% 95.0%
25 03-08 Driveway Base C6 132.1 6.1 127.1 96.2% 95.0%
26 07-25 Dr. Approach Jedediah Smith SG A2 127.2 7.2 121.5 95.5% 95.0%
27 07-25 Dr. Approach Jedediah Smith SG A2 127.2 6.8 121.4 95.4% 95.0%
~
EnGEN Corporl;\tion ....
II
I
I
I
I
I
I
I
I
I
I
I
, I
I
!I
I
I
I
1
Gupta Residence
Project Number: T3065-C
Page 1
SUMMARY OF OPTIMUM MOISTURE CONTENT
MAXIMUM DRY DENSITY RELATIONSHIP TEST RESULTS
ASTM D 1557-02
Maximum Optimum
Soil Description (USCS Symbol) Soil Type Dry Density Moisture
(PC F) Content (%)
Silty Sand Light Brown (SM) A2 127.2 9.4
Sandy Gravel Brown (GW) C1 132.1 7.4
s
EnGEN Corporation