Loading...
HomeMy WebLinkAboutTract Map 9833 Lot 25 Soils DllJCO. ENGINEERING, INC. SOIL & GEOLOGIC INVESTIGATIONS FIll. CONTROL - SOIL TESTING 20938 CURRIER RD. - WALNUT, CA 91789 . (909)594-7414 . FAX (909) 594-3853 REPORT OF SOILS INVESTIGATION PROPOSED PRIVATE RESIDENCE LOT 25, TRACT 9833. i EL FARO PLACE TEMECULA, CALIFORNIA FOR: Mr. and Mrs. Sean Browning 28234 Corte Malbino Temecula, CA 92592 May 24,1999 Job No.: 99-25 \ Page One May 24,1999 Job No.: 99-25 Introduction This report presents the results of a geotechnical investigation for a residential parcel of land to be developed in the City of Temecu1a, California. Figure No. 1 presents a plot plan of the site-showing the soils data and surface features deemed pertinent to this report. The object oethis investigation was to gather information and test data regarding the surface and subsurface soils conditions existing on the site upon which to base our recommendations for the safe and economical site preparation, grading and construction of the proposed structure. The results of our field and laboratory investigations, which form the basis of our recommendations, are included as a part of this report. Site Conditions The subject site occupies approximately 2.66 acres of an irregularly shaped parcel of property located at the western end ofEI Faro Place in the City of Temecula, California. Topographically, the site is characterized by a gentle to moderately sloping, south trending ridge, which has been altered by previous grading to create a level pad along the ridge crest. Fairly uniform (1.5:1 to 2:1) natural slopes descend to the east and west. The overall relief is approximately thirty-six (36) feet on the west and fifty-six (56) feet on the east. The existing natural slope gradients on the site vary from nearly level on the graded pad area to as steep as 1. S: 1 locally on the flanks of the ridge. Current site drainage is by sheetflow toward the east to El Faro Place and to the west into a south flowing drainage course, Surface vegetation currently consists of moderate to locally heavy assemblages of native and volunteer weeds, grasses and shrubs on the undisturbed area of the lot and a light to locally heavy assemblage of weeds and grasses on the cut pad area.. The soils encountered in the test holes consisted of soft to fairly firm topsoils composed of clayey silts and silty clays varying between three (3) and four (4) feet in thickness, overlying dense to very dense silty to clayey, coarse to medium sands with scattered gravel, silty fine to very fine sands and coarse to fine sandy silts of the Pauba Formation. z. Page Two 'May 24, 1999 iJob No.: 99-25 'No ground water or appreciable caving of the side walls were encountered during the . excavation of the test holes to the depths explored. I Prooosed Develooment 'The subject parcel is proposed to be developed by conventional cut and fill grading procedures to construct an access drive from EI Faro Place and to create a building pad suitable for the construction of a single family residential structure with raised foundations, . a barn, tennis court and a future swimming pool. Fill soils will be generated by lowering the existing pad grade as needed and the cutting of a 2: 1 to 3: 1 slope on the east flank of the ridge. The majority of the fill will be placed to construct the driveway and tennis court. The structure will be constructed on natural . ground. No grading will take place on the west slope of the property. I Field Investil!ation the subsurface soils conditions were explored by excavating seven (7) engineering test holes to depths of six (6) to seven (7) feet with a backhoe using an eighteen (18) inch wide . bucket. The approximate location of each test hole is shown on Figure No. 1. , Relatively undisturbed samples and disturbed, bulk samples of the typical soils ,encountered in the test holes were obtained to be subjected to laboratory testing and . analysis. A continuous log of each test hole was kept in the field at the time of excavation. These test hole logs, reflecting the condition and classification of each soil strata encountered, . based on the Unified System of Soil Classification, as devised by A. Casagrande, are presented as a-part of this report as Figure Nos. 2 through 8. , Laboratory Investil!ation In-situ moisture and density tests were performed on the undisturbed samples and the results of these tests are shown on the appropriate test hole logs at the depths sampled. Also shown are results of calculations made to determine the relative compaction of the samples compared to the maximum density determined in accordance with ASTM test method D1557-94T. The expansion potential of the onsite soils was determined in accordance with the UBC test standard 18-2. The results of the laboratory tests performed on the typical bulk soil . samples are summarized as follows: .3 Page Three May 24,1999 . Job No.: 99-25 Soil Tvoe Maximum Densitv Ootimum Moisture Exoansion Index A-Clayey silty crse. to med. sand 130.6 oct: 8.0"10 IS B-Silty crse. to med. sand 129.3 oct: 8.0"10 15 C-Silty very fine sand 118.5oef. 12.3% 65 D-Silty fine to med. sand 119.9 oct: 11.3% - E-Crse. to finesandy silt 121.9ocf 10.5% - F-Slightly clayey med. to crse. sand 129.4 net: 7.8% 21 Direct shear tests were performed on selected samples of the undisturbed soils. The , samples were tested in a state of saturation in order to duplicate extreme field moisture ,conditions. The results of these tests, showing peak and ultimate values are shown : graphically on Figure Nos. 9 and 10. The results of consolidation tests, indicating the load-settlement characteristics of the , typical subsurface soils are shown on the Consolidation Test Reports, presented as Figure Nos. 11 through 14. : Conclusions and Recommendations , Development of the site, as proposed, is considered to be feasible from a geotechnical engineering standpoint, based on the implementation and incorporation of the ,recommendations which follow into the site preparation, grading, design and site development, . The preliminary results of the geotechnical investigation indicate that the site may be developed by conventional grading procedures. the eighteen (18) foot high 2: 1 to 3: 1 cut ,slopes in the area proposed will result in a stable slope condition. General recommendations for site grading are as follows: . Site Preoaration and Gradinl! . Prior to any grading, all existing surface vegetation, including brush and shrubs, not to remain, shall be stripped and hauled off site to the satisfaction of the geotechnical engineer. 4 Page Four May 24,1999 Job No.: 99-25 The resulting cavities shall be cleaned of roots and loose soils, processed as specified by the geotechnical engineer, and brought to grade with compacted fill if not entirely removed in a proposed cut or removal area. Any fill soils encountered within the proposed grading area shall be removed to expose the underlying natural ground, as determined by the geotechnical engineer. These materials may be incorporated into the compacted fill, when cleaned of any decomposable substances. Prior to the placing of any fill soils, the existing topsoils shall be removed to a minimum depth of two (2) feet to expose the underlying approved natural ground. On slopes steeper than 5: 1 a minimum fifteen (15) foot wide by two (2) foot deep shear key (measured into approved ground on the downslope side) shall be excavated at the toe of slopes. The shear key shall be approved by the geotechnical engineer prior to filling. If any retaining walls are to be constructed prior to starting a fill slope, the excavation should be brought to the original ground elevation with compacted fill and the wall tootings shall be excavated into the compacted fill. All retaining walls shall be allowed to cure properly prior to surcharging with fill. As the compacted fill placement progresses upslope, all topsoils shall be removed to expose the underlying, competent natural ground and adequately sized, horizontal benches shall be excavated into the bedrock to receive the compacted fill. Prior to placing any compacted fill, the exposed surface of the approved natural ground shall be thoroughly. scarified to a depth of six (6) inches, moisture conditioned as necessary and shall be precompacted to the minimum requirement specified herein. The fill soils shall be. spread in six (6) to eight (8) inch thick, loose lifts, watered or dried back as necessary to provide near optimum moisture content and shall be compacted to a minimum of 90% of the maximum density determined in accordance with ASTM test method DI557-94T. The cut portion of the tennis court shall be undercut and recompacted to a depth of three (3) feet. As the fill slopes progress upwards the surface shall be backrolled at maximum four (4) foot vertical intervals using a sheepsfoot roller and the finished slope surface shall either be grid or track rolled to provide 90% compaction to the slope surface or the slope shall be overfilled sufficiently to allow for trimming back to expose the compacted inner core. -s Page Five May 24, 1999 Job No.: 99-25 The estimated subsidence anticipated to occur during the processing of the natural ground I to accept fill will be on the order of 0.1 foot. The anticipated shrinkage in soils volume expected to occur during the removal and 1 recompaction of the topsoils and bedrock will be on the order of 10"10 to 15% for the : topsoils and 0% to 5% for the bedrock. The actual shrinkage will depend on the average , degree of compacted obtained. . Any imported fill soils required to be brought to the site for use as structural fill shall be . approved in advance of importation by the geotechnical engineer. I Foundation Recommendations The recommended soil bearing value for continuous and square footings a minimum of , fifteen (15) inches in width and embedded a minimum depth of eighteen (18) inches below the lowest adjacent ground surface shall be 2000 psf. and 22S0 pst: respectively. This ,value may be increased by 20"10 for each additional foot in depth and/or width to a maximum value of 3000 pst: Lateral value may be computed at 250 pst: per foot of depth to a maximum value of 3000 pst: 'The anticipated maximum settlement for foundations designed in accordance with the foregoing recommendations, is on the order of 0.40 inch with maximum differential settlement on the order of 0.20 inch. i Exoansive Soils Recommendations I The expansion potential of the existing onsite topsoils and bedrock is are considered to be low to moderate. It is assumed that the topsoils and bedrock materials will be blended during grading and will be similarly expansive. The recommended remedial construction measures required to minimize the affects of this condition are shown on Figure No. 15. A final determination of the expansion potential should be made upon the completion of . grading. Additional reinforcement of the foundations and any floor slabs should be made in . consideration of structural strength requirements of the structural engineer. c.. Page Six May 24,1999 Job No.: 99-25 Soil Corrosivitv Studv Laboratory tests were conducted on the near surface soils to determine if these soils may have deleterious effects on underground utilities and concrete floors and slabs. The results of these tests are as follows: Soluble Sulfate per Soluble Chloride Minimum pH CA. 417 per Resistivity per CA. CA.422 643 'Bor. #1 90: oom 54 oom 2774 ohm-em 6.8 'Bor. #4 100.oom 64 oom 1416 ohm-em 6.6 Based on the results of the above tests, the onsite soils are considered to be moderately corrosive. It is recommended that all metal pipes should be wrapped with poly-sleeves or other appropriate materials. As an added precaution the metal pipes in trenches should be backfilled with.clean sand. Type I or II cement may be used in concrete poured in direct contact with onsite soils. Site Drainal!e ;Recommendations All surface runoff shall be conducted away from the top of the slopes onto approved drainage devices. The residence shall have roof gutters to collect runoff and conduct it to approved, non.,erodable drainage areas. Retaininl! Wall Recommendations When properly drained and backfilled, any proposed retaining walls shall be designed for the following equivalent fluid pressures: Slope of Retained Surface Recommended Equivalent Fluid Pressure Level Surcharlle 35 oct: 3: 1 Surface Gradient 38 oct: 2: 1 Surface Gradient 45 oct: All retaining walls shall be provided with adequate weep holes or sub drains to preclude the build-up of hydrostatic pressure. 1 I Page Seven 'May 24, 1999 Job No.: 99-25 Backdrains Sha11 consist of a four (4) inch diameter, perforated pipe, with perforations . down. The pipe shall be surrounded by twelve (12) inches ofo/. inch gravel wrapped in an approved filter fabric to minimize the infiltration of soil particles. The drains shall be , graded to flow to a suitable outlet or controlled disposal system which will not result in . erosion or saturation of the slope surface. A coefficient offiiction of 0.35 may be used between the concrete poured in direct contact with the compacted fill or bedrock. , It is the opinion of this firm that once the site has been satisfactorily graded in accordance , with the recommendation contained in this report, the site will be free from the hazard of landslide, settlement or slippage and will not adversely affect the geologic stability of the . adjacent properties. . The recommendations contained in this report are based on the results of our field and , laboratory investigations, combined with the principles of modern soil mechanics and . sound engineering judgment. Should any unusual conditions or should drastic design changes be contemplated, this 'firm shall be notified inunediately in order that proper modification to the recommendations contained herein may be made as deemed necessary. If you have any questions with regard to this report or the recommendations contained , herein, please contact this office. Respectfully submitted, DUCO ENGINEERING, INC. ~&~ Ronald Cobine Approved by: ~ c. ~ ~ J " " ........l! ,tl\ ;" t l' " ~\ :, : : :' ,; !flC'~ \ . -~ T ..:::..- .,.:'-: .; t",,' , It ~ if j (, _. r~_~ ,~I , ~ 1~ .1~ \'1\ . \ ,- ~. j', -::. ~ j, ,- -' 'if-' -, ,;1".-1 /1 -~ :",t / ", c :r / ~ , '.~ li /~1 b ..~. t / , . l \ d6S~~~ ~ . ' ,_..-~../ , 00-'" / ~-_. _.._..~/.-,.....-._-- ./ " " "" /-..... .-.. .~~ i ,,x> "~. ~ !; _/ :::~~=-=:~~~:-,. '....... /.., ..,,---_.._.~._- /-......-.------ , ~ \ :'/ ".' 't;.~~ n" : i ~ C i c: ~ n ~ 0 :II ~ m '? Z G) - Z \! m c m i!l :II :D z _ > ! Z i G) . . ~ v " o " . " ~ :0 ~ !Z ~ ''I: 170<>- --.---... . -! ~ -l , '" 0 (II n -l . :c ~ o 0 ,. z l'ilo ." , i I , I / j / o,v,~ /(;;<00. " 0& <? ." c...'CIJ Cion emJ> ;nz' !TIO'" Z - 0-1)" . .j) 6'> _,0 ~ 't ...." \\ ' ." ;)ijf\ /; ./ ' 'I '. \., i '11'{; .". ..; < i. I~ ~/ rS'~ J' I 00 ..,~ ,,"I .. ~' /' .~ ,l' ~-.L . ~ ~ KEY TO SYMBOLS Symbol Description Strata symbols mIl - ~ ~ [[[ill IIIIi1 llilliilllillJ [IT] l2J ~ Poorly graded clayey silty sand Silty sand and gravel Clayey sand Silt Silty sand Poorly graded sand Clayey gravel Soil Samplers . California sampler Notes: 1. Exploratory test holes were excavated on April 21, 1999 using a conventional rubber-tired backhoe with an 18 inch wide bucket. All test holes. were immediately backfIlled upon the completion of the logging and sampling. 2. No free water was encountered at the time of excavation. 3. Test hole locations were extrapolated from existing features and the elevations extrapolated from an assumed datum elevation. 4. These logs are subject to the limitations, conclusions, and recommendations in this report. 5. Results of tests conducted on samples recovered are reported on the logs. \0 SOIL EXPLORATION LOG PROJECT: Browning Residence - EI Faro, Temecula JOB NO.: 99--25 CLIENT: Sean Browning LOCATION: See Figure No. 1 LOGGED BY: RDC EXCAVATING EQUIPMENT: DEPTH TO WATER: None Encountered CAVING: TEST HOLE NO.: DATE: 4.21-99 ELEVATION: 1172.0 Backhoe None Encountered SUMMARY OF SUBSURFACE CONDITIONS: This log is pan of the repon prepared by Duco Engineering, Inc. for this project and should be read. together with the report. This summary applies only to the location of the test hole at the time of the excavation. Subsurface conditions may differ at other locations and may change at this location with the ! DasS3.lie of time. The data presented is a simclification of the actual conditions encountered. SAMPLEOATA f;; '~ ,,; U ~~ ~Z t:l"' U ~o DESCRIPTION i": go ~~ g 0,. w~ ~ UJ',e ,,; '"~ c. ..'" 0- ",0 ::i CC ,.'! 8 u 0 -'~ 15~ ~o ~.. 0 SM-SC lm1Bt Clayey Silty Coarse to Medium Sand - brown to light brown - top 12" loose ~ A .. then firm . damp to moist - scattered --.J 30 gravel 5.6 107.5 82.3 5 GM-SM I Silty Coarse to Medium Sand with Gravel IS B - tan brown. firm - moist 8.4 112.1 86.7 .. , .. Bottom of Test Hole 10 15 20 25 30 DUCO ENGINEERING, INC. FIGURE NO.: 2 ~\ SOIL EXPLORATION LOG PROJECT: Browning Residence - El Faro, Temecula JOB NO.: 99--25 CLIENT: ,sean Browning LOCATION: See Figure No.1 LOGGED BY: RDC EXCAVATING EQUIPMENT: DEPTHTO WATER: None Encountered CAVING: TEST HOLE NO.: 2 DATE: 4-21-99 ELEVATION: 1214.0 Backhoe None Encountered SUMMARY OF SUBSURFACE CONDITIONS: This log.is pan of the report prepared by Duco Engineering, Inc. fur this project and should be read together with the report. This summary applies only to the location of the test hole__3t the time of thC?__~~cavation. Subsurface conditions may differ at other locations and may change at this location with the passa~e of time. The data nresented is a simnlification of the actual conditions encountered. SAMPLE DATA fti "' 0 ~ ~~ ~.... ...l'" :to ~u:: eZ -0, U ~3 DESCRIPTION 0,.. ~ ",<I' ...l::> ~~ .; "'" 0; .." 0- <oe ;:i 0" ,..,! 8 u 0 -'~ ~:3 ",0 ~.. 0 '.;<." . Clayey Coarse to Medium Sand - sc ';;z:;-: ..... . brown to light brown -top 12" soft .".. . then fairly dense - damp to moist - ..... . scattered gravel . .. .. . - A ./'x 30 '/':/ 5.4 111.6 85.5 5 GM-SM ..... . ., Silty Coarse to Medium Sand with '. : scattered Gravel - tan brown - firm - .. moist .. - .. 10 B I 9.3 108.2 83.7 ~ ,. 10 Bottom of Test Hole 15 20 25 30 DUCO ENGINEERING, INC. FIGURE NO.: 3 \Z- SOIL EXPLORATION LOG PROJECT: Browning Residence - EI Faro, Temecula JOB NO.: 99--25 CLIENT: Sean Browning LOCATION: See Figure No.1 LOGGED BY: RDC EXCAVATING EQUIPMENT: DEPTH TO WATER: None Encountered CAVING: TEST HOLE NO.: 3 DATE: 4-21-99 ELEVATION: 1182.0 Backhoe None Encountered SUMMARY OF SUBSURFACE CONDITIONS: This log is part .of the report prepared by Duco Engineering, Inc. far this project and should be read together with the report. This summary applies .only ta I the location .of the test hole at the. time .of the ~xcavation. Subsurface conditions may differ at ether locations and may change at this location with the InaSS3lJe ohime. The data "resented is a simnlification of the actual conditions encountered. SAMPLE DATA ~1? '" ,; Sl ~~ ,~.... ....'" U :I: " z": :05 -"- ~3 DESCRIPTION 0> w~ ~ ",<Il I~O lil1:: ,; "'~ o. ..'" Cl~ ;:i 00 >'" 0 , u " -'~ ~:3 u !!l0 ~.. 0 SC ... ... Clayey Coarse to Medium Sand - ..... . brown to light brown - top 12" soft ." ... then dense - damp to moist - ... ... scattered gravel I- A . .. .. . ~ :25 ... ... 6.8 109.7 84.0 ::/:z' 5 ... . Bottom of Test Hole 10 15 20 25 30 DUCO ENGINEERING, INC. FIGURE NO.: 4 \~ SOIL EXPLORATION LOG PROJECT: Browning Residence - EI Faro, Temecula JOB NO.: 99--25 CLIENT: Sean BrowninJ; LOCATION: See Figure No.1 LOGGED BY: RDC EXCAVATING EQUIPMENT: DEPTH TO WATER: None Encountered CAVING: TEST HOLE NO.: 4 DATE: 4-21-99 ELEVATION: 1210.0 Backhoe None Encountered SUMMARY OF SUBSURFACE CONDITIONS: Tbis log is part of the report prepared by puco Engineering, Inc. for this project and should be read together with the report. This summary applies only to the location of the test hole at the time of the excavation. Subsurface conditions may differ at other locations and may change at this location with the oassali!:e of time. The data Dresented is a simolification of the actual conditions encountered. SAMPLE DATA E% '" .,; U ~~ ~,.. diE u 51" ffiu: oZ ~3 DESCRIPTION 0,.. ~ ",<ll ,..,;:J Sl~ .,; ~'" 0; ,,~ 0- CQ:O ;:i 00 ,..\,> 0 u " ~~ ~j u ~o ~" 0 ML Silty Very Fine Sand - yellow tan top 12" fractured then very dense - C damp i 32 8.4 108.9 91.9 5 6" thick coarse sand lense @ 5.5' depth , 25 D SM Silty Fine to Medium Sand - tan grey - 22.8 102.4 85.4 dense - damp scattered coarse sand lenses 10 SP : Coarse to Medium Sand - grey and tan - .. : .. dense - damp 15 .- Bottom of Test Hole 20 25 30 DUCO ENGINEERING, INC. FIGURE NO.: 5 'A SOIL EXPLORATION LOG PROJECT: Browning Residence - EI Faro, Temecula JOB NO.: 99--25 CLIENT: Sean Browning LOCATION: See Figure No.1 LOGGED BY: RDC EXCA VA TING EQUIPMENT: DEPTH TO WATER: None Encountered CAVING: TEST HOLE NO.; 5 DATE: 4-21-99 ELEVATION: 1229.0 Backhoe None Encountered SUMMARY OF SUBSURFACE CONDITIONS: This log i~ part of the report prepared by D.uco Engineering, Inc. for this project and should be read together with the report. This summary applies only to the location (lfthe test hole at the time of the ~xcavation. Subsurface conditions. may differ at other locations and may change at this location with the passage of time. The data "resented is a simnlification of the actual conditions encountered. SAMPLE OATA ~;; '" '" U ~~ ~.... =~ U 51" ffiti OZ "'0 DESCRIPTION 0>- ~ "'~ ",::> 5l~ .; ;:l'" ~" cd ..~ 0- <00 ;:i 00 >-!i 0 U " ~~ ~:i u ~o ~.. 0 SC :9% Coarse Sandy Clay - reddish brown - finn to dense - damp ML Coarse to Fine Sandy Silt - tan - dense to very dense - moist ----. E scattered coarse to medium sand lenses 42 8.6 121.3 99.5 5 Bottom of Test Hole 10 15 20 25 30 DUCO ENGINEERING, INC. FIGURE NO.: 6 '6 SOIL EXPLORATION LOG PROJECT: Brownin2 Residence - EI Faro, Temecula JOB NO.: 99--25 CLIENT: Sean Browning LOCATION: See Figure No.1 LOGGED BY: RDC EXCAVATING EQUIPMENT: DEPTH TO WATER: None Encountered CAVING: TEST HOLE NO.: 6 DATE: 4-21-99 ELEVATION: 1228.5 Backhoe None Encountered SUMMARY OF SUBSURFACE CONDITIONS: This log is pan of the report prepared by Duco Engineering, Inc. for this project and should be read together with the report. This summary applies only to the location of the test hole at the time of ,the excavation. Subsurface conditions may differ at other locations and may change at this location with the I Dass3l!:e of time. The dati -"-resented is a simnlification of the actual conditions encountered. SAMPLE DATA '" 0 u ~o ~f-< ::I'" ~o .i! 015 ~~ u "'0 0; ;23 Q- "'u ;:i " 0 sc //.;: ML DESCRIPTION ~~ 0>- ~" 00 ~~ ,"0 ~.. ffiLi 0; >-'< ~:3 ~ ..~ o u Coarse Sandy Clay - reddish brown - dense - moist Coarse to Fine Sandy Silt - tan - dense -damp 5 i 40 E scattered silty coarse sand lenses 12.4 113.9 93.4 i 40 E 7.1 108.8 89.3 10 Bottom of Test Hole IS 20 25 30 DUCO ENGINEERING, INC. FIGURE NO.: 7 \(, SOIL EXPLORATION LOG PROJECT: Browning Residence - El Faro, Temecula JOB NO.: 99--25 CLIENT: Sean Browning WCATION: See Figure No. 1 WGGED BY: RDC EXCAVATING EQUIPMENT: DEPTH TO WATER: None Encountered CAVING: TEST HOLE NO.: 7 DATE: 4-21-99 ELEVATION: 1229.0 Backhoe None Encountered SUMMARY OF SUBSURFACE CONDITIONS: This log i~ part of the report prepared by Duca Engineering, Inc. for this project and should be read together with the report. This summary applies only to the location of the test ho!e_~t the time of the excavation. Subsurface conditions may differ at other locations and may change at this location with the Dassae:e of time. The data presented is a simplification of the actual conditions encountered. SAMPLE DATA ~'ii' . '" .; s. ~~ ~.e- d'" c3 S;" ffili OZ Sl~ DESCRIPTION o~ ~ "'~ ....::> .; ;;is ~~ 0, ~~ o~ 010 ::> 00 ~" 0 u " ,.,~ 2S~ u ",0 u:~ 0 GC ~ Slightly Clayey Medium to Coarse Sand ~ with scattered gravel - reddish tan - dense - moist f-- F f-- ,30 8.8 108.2 83.6 5 ~ Bottom of Test Hole 10 , 15 20 25 . , . , . 30 DUCO ENGINEERING, INC. FIGURE NO.: 8 \1 I 900 'i" t I ~~ (fJ (fJ 600 Q. Q. " " :J '- :J 0 ~ 0 w u.. f- -'" 300 <{ 0 '" " H 0- f- .J ~ 0 0 900 750 ~ (fJ a. 600 (fJ (fJ " L 450 ~ ''''1 (/) L 0 300 " .<: (/) 150 0 0 300 5 10 15 Strain, % SAMPLE TYPE: Undisturbed DESCRIPTION: Clayey Si I ty Sand SPECIFIC GRAVITY= 2.65 REMARKS: JT Fig. .No.: q 600 pst 4>, deg TAN <l> 1200 900 Normal Stress. psf SAMPLE NO. : 3 WATER CONTENT, % ~ DRY DENSITY. pet ~ SATURATION, % !i VOID RATIO H . DIAMETER. In HEIGHT, in WATER CONTENT, % f- DRY DENSITY, pet (/) W SATURATION, % f- f- VOID RATIO <{ DIAMETER, in HEIGHT in NORMAL STRESS, pst Peak Fa i I ure I psf STRAIN, % ULTIMATE tai lue. pst STRAIN, % Strain rate, in/min 2 20 CLIENT: Sean Browning Peak 128 37.2 0.76 ULTIMATE 122 35.9 0.72 1500 24.4 8.6 94.6 109.3 86 . 5 44 . 3 0.749 0.514 2.50 1.00 17.6 94.6 62.4 0.749 2.50 1.00 260 321 6.9 303 11,7 0.0532 PROJECT: Proposed Residence El Faro, Temecula SAMPLE LOCATION: Baring #1 Sample #2 @ 5,5' PROJ. NO. 99-25 2.50 1.00 16.1 109.3 82.8 0.514 2.50 1.00 520 532 10.1 514 11.2 0.0532 2 1800 3 8.4 111.0 45.3 0.491 2.50 1.00 15.8 111.0 35.4 0,491 2.50 1.00 780 716 9.6 679 12,8 0.0532 DATE: 5-17-99 DIRECT SHEAR TEST REPORT DUCO ENGINEERING, INC. \~ I 1800 'i" t I -- CIl CIl 1200 0. ,0. ., ., OJ L OJ o ._ - 0 w"- 600 r- .y. <{ 0 ::> ., HO- r- ..J :0 0 0 1200 1000 - CIl 0. 800 CIl CIl Q) L 600 ~ (f) L 0 400 Q) ;: (f) 200 600 1200 1800 2400 Normol Stress, pst SAMPLE NO. : WATER CONTENT, % ~ DRY DENSITY, pet f-:i SATURATION, % 'i VOID RATIO H DIAMETER, in HEIGHT in WATER CONTENT, % r- DRY DENSITY, pet (f) W SATURATION, % r- r- VOID RATIO <{ DIAMETER, in HEIGHT, in NORMAL STRESS, pst Peak Fai lure, psf STRAIN, % ULTIMATE tai lue, pst STRAIN, % S t ro i n ra t e . i n/m i n 5 10 15 20 Strain, % SAMPLE TYPE: Undisturbed DESCRIPTION: Clayey Silty Sand CLIENT: Sean Browning PROJECT: Proposed Residence EI Faro, Temecula SAMPLE LOCATION: Boring #5 Sample #1 @ 4.0' SPECIFIC GRAVITY= 2,65 REMARKS: JT Fig, No.: PROJ, NO.: 99-25 Peak 388 41.2 0.87 ULTIMATE 110 31.7 0.62 3000 3600 2 3 2.50 1.00 20.8 115.8 128.4 0.429 2.50 1.00 520 844 4.8 440 12,2 0.0532 DIRECT SHEAR TEST REPORT 10.4 13.7 10,2 114.7 115,8 116,6 62.4 84.9 64,4 0.442 0.429 0.419 2.50 1.00 18.7 114.7 112.3 0.442 2.50 1.00 260 294 6.4 266 7.3 0.0532 2.50 1.00 17.6 116.6 111. 1 0,419 2.50 1.00 780 1082 4.3 587 9.6 ".0532 DATE: 5-17-99 /0 OUCO ENGINEERING. INC. \, 3.0 CONSOLIDATION TEST REPORT 2.0 Water Added --.. '" ... .... "" "- \ \ 1\ , \ \ .01 .05 0.1 0.2 0,5 1 Appl ied Pressure - tsf 2 5 10 1.0 SWELL 0.0 <l> COMPRESSION " [j] ""- 1 .0 c 0 {Jl (Jl I]) 2.0 L 11- E 0 U ... 3.0 c <l> 0 L <l> 11. 4.0 5.0 6.0 7.0 Clpse. Nat. Nat. Dry Dens. % Sa t . Ma i st. ( pc f ) o . 3 48 . 8 % 9. 3 % 1 09 . 8 TEST RESULTS LL PI Sp . Gr. In i t i a I va i d ra t i a 2.650 0.5065 MATERIAL DESCRIPTION Project Na,: 99-25 Praiect: EI Fara, Temecula Loc~tion: Boring #7 Sample #1 @ 3.0 feet Date: 4-29-99 CONSOLIDATION TEST REPORT Medium ta Caarse Gravelly Clayey Sand Class: GP-SC Remarks: JT DUCO ENGINEERING, INC. 1P Fig. No. -JI_ Clpse. No t . Not. Dry Dens. LL % Sat, Mo i st. (pc f) 0.3 53.8 % 8.6 % 116.3 TEST RESULTS Project No.: 99-25 Project: EI Faro, Temecula Location: Boring #5 Sample #1 @ 4.0 feet Date: 5-7-99 CONSOLIDATION TEST REPORT 1.0 SWELL 0.0 COIAPRESSION 1.0 OJ ;, V1 " 2.0 c 0 Ul Ul OJ 3.0 I... Q. E 0 0 +' 4.0 c OJ 0 I... OJ 0- 5.0 8.0 CONSOLIDATION TEST REPORT 2.0 Water Added -.... '" .... ... '" 1'00.. ~ .... ~ ~, ..... ... ~ \ I'-..... r\ I' , .... ... \ " \ ~ '" ...... ..... ... 6.0 7.0 .01 .05 0.1 0.2 0.5 1 Appl ied Pressure - tsf 2 5 10 PI Sp.Gr. Initial void ratio 2.650 0.4240 MATERIAL DESCRIPTION Coarse to Fine S i I ty Sand Class: SM Remarks: JT -z,\ DUCO ENGINEERING, INC. Fig. No. If!... Clpse. Not. Not. Dry Dens. LL % Sat. Mo i st. (pcf) 0.2 68.2 % 14.8 % 105,2 TEST RESULTS COMPRESSION 2.0 Q) ~ (J) "- 3.0 c 0 Ul Ul Q) 4.0 L Q. E 0 U +- 5.0 c Q) 0 L Q) Q. 6.0 9.0 1.0 CONSOLIDATION TEST REPORT 0.0 I Water Added -- ..... r-. " I'r-o, ... ...... '" 1\ ...... .... " \ ~ \ ..... l' , f' \ " "" \ '" l' , .... ..... " SWELL 1.0 7.0 8.0 ,01 .05 0.1 0.2 0,5 1 Appl ied Pressure - tsf 2 5 10 PI Sp. Gr. Initial void ratio 2.650 0.5732 MATERIAL DESCRIPTION Coarse to Fine S i I ty Sand Closs: SM Remarks: JT Project No. :99-25 Project: EI Faro, Temecula Location: Boring #6 Sample #1 @ 5,0 feet Date: 5-11-99 CONSOLIDATION TEST REPORT DUCO ENGINEERING, INC_ F i , No. I.J ~ CONSOLIDATION TEST REPORT 6.0 Water Added . - ~ '" " ~ \ \ " , \ 4.0 2.0 SWELL 0.0 II) COI.4PRESSION ~ (/) '- 2.0 c 0 Ul Ul II) 4.0 '- D- E 0 () +' 6.0 c II) u '- II) D- 8.0 10.0 12.0 14.0 ,01 .05 0.1 0.2 0.5 1 Appl ied Pressure - tsf 2 5 10 Clpse. Not. Not. Dry Dens. % Sat. Moist. (pcf) 44 . 0 % 9. 4 % 105 . 6 TEST RESULTS LL PI Sp.Gr. Initial void ratio 2.650 0.5662 MATERIAL DESCRIPTION Project No,: 99-25 Project: EI Faro, Temecula Location: Boring #1 Sample #2 @ 5,5 feet Date: 5-13-99 CONSOLIDATION TEST REPORT Coarse to Medium Gravelly Si I ty Sand Class: GP-SM Remarks: JT DUCO ENGINEERING, INC. Fig, No. /'1 1--7 RECOMMENDATIONS FOR CONSTRUCTION IN EXPANSIVE SOILS D~pth of Base Rock Slab Thickness or washed Depth of Continuous footings EXPANSION footing below Slab Reinforcement concrete Subgrade for all bearing walls INDEX lowest sand with Saturation In and a grade beam adjacent Foundation moisture Slab Areas across the garage UBC 18-2 finished dirt Reinforcement barrier door opening grade membrane o to 20 Nominal 4 Inches 12.0 Inches None required None Not Required Not Required Very Low Required None required Nominal 4 Inches 4 Inches of 21 to 50 6X6-10/10 Welded Base - or 12.0 Inches wire mesh In center 6 mil. In 12 Inches Required I Low One #4 rebar In the center of top and In the bottom sand Full 4 Inches thick 4 Inches of 61 to 90 6X6~/6 Welded wire Base - or 18.0 Inches mesh In center 6 mil. In 18 Inches Required Moderate Two #4 rebar In the center of top and In the'boltom sand Full 6 Inches thick 6 Inches of 90 to 130 6X6~/6 Welded wire Base - or . 18.0 Inches mesh In center 6 mil. In 18 Inches Required 'High Two #5 rebar In the center of top and In the bottom sand Full 6 Inches thick wI 6 Inches of Above 130 #3 rebar 18 Inches O.C. Base - or 24.0 Inches each way dowelled Into 10 mil. In 24 Inches Required Ve,rylHigh the cont. footings. center of Two #5 rebar In the top sand and In the bottom DUCO ENGINEERING, INC. Job No,: 99-25 ']A Figure No.: IS ,