Loading...
HomeMy WebLinkAboutTract Map 21430-1 Lot 61 Geotechnical Report & Gompaction Results11 1 F 91 I lull I 8 B I I v • SoilEn EN Corporation :"iogiloAneeYr ENVIRONMENTAL & GEOTECHNICAL REPORT AND COMPACTION TEST RESULTS PRECISE GRADING OPERATIONS Villa Residence LD 01-027GR Lot 61 of Tract 21430-1 North General Kearny Road City of Temecula, County of Riverside, California Project Number: T2189 -C May 21, 2001 Prepared for: Mr. & Mrs. Julio Villa 32915 Sheila Lane Idomar, California 92595 -- -- t -- -- t -- — CITY FEa ing ng tial Site A99eSunents Mr. and Mrs. Julio Villa Project Number: T2189 -C ' TABLE OF CONTENTS SECTION NUMBER AND TITLE PAGE ' 1.0 SITE/PROJECT DESCRIPTION AND LOCATION.............................................................1 1.1 PROJECT LOCATION................................................................................................. 1 1.2 PROJECT DESCRIPTION............................................................................................2 1.3 SITE DESCRIPTION .... .................. .............................................................._............2 2.0 SCOPE OF WORK....................................................................................................2 2.1 TIME OF GRADING...................................................................................................2 ' 2.1 CONTRACTOR AND EQUIPMENT ................ ............................... ... .............................. .2 2.2- GRADING OPERATIONS............................................................................................2 3.0 TESTING.................................................................................................................3 ' 3:1 FIELD TESTING PROCEDURES .................... 3 3.2 LABORATORY TESTING.............................................................................................3 3.2.1 MOISTURE -DENSITY RELATIONSHIP TEST....................................................3 3.2.2 EXPANSION INDEX TEST.............................................................................3 3.2.3 SOLUBLE SULFATE TEST............................................................................3 3.2.4 PLASTICITY INDEX......................................................................................4 40 EARTH MATERIALS..................................................................................................4 5.0 CONCLUSIONS AND RECOMMENDATIONS...................................................................4 5.1 FOUNDATION DESIGN RECOMMENDATIONS................................................................4 5.2 FOUNDATION SIZE-...................................................................................................4 ' 5.3 DEPTH OF EMBEDMENT............................................................................................4 5.4 5-5 BEARING CAPACITY.................................................................................................5 SETTLEMENT...........................................................................................................5 5.6 5.7 LATERAL CAPACITY..................................:..............................................................5 SLAB -ON -GRADE RECOMMENDATIONS......................................................................6 5.8 INTERIOR SLABS......................................................................................................6 1 5.9 EXTERIOR SLABS.....................................................................................................6 5.10 GENERAL 7 1 6.0 CLOSURE................................................................................................................7 APPENDIX TEST RESULTS ' DRAWINGS EnGEN Corporation Z _ • Soil Engineering and Consulting Services • Engineering Geology • Compaction Testing GEN Corporation speclione • Conslmcl ,=once tudiessling • e I & 11ory Testing • PercolationTesting i:!!. - • GroIoAY • Water flesource Studies • Phase 8 II Environmental Site Assessments ENVIRONMENTAL & GEOTECHNICAL ENGINEERING NETWORK May 21, 2001 ' Mr. & Mrs. Julio ,Villa 32915 Sheila Lane ' Wildomar, California 92595 (909) 678-3841 Attention: Mr. & Mrs. Julio Villa Regarding: GEOTECHNICAL REPORT AND COMPACTION TEST RESULTS PRECISE GRADING OPERATIONS Villa Residence LD 01-027GR Lot 61 of Tract 21430-1 ' North General Kearny Road City of Temecula, County of Riverside, California Project Number: T2189 -C References: 1. EnGEN Corporation, Site Review Letter, Proposed Single Family Residence, Lot 61 of Tract 21430-1, North General Kearny Road, City of Temecula, California, Project Number: 2189-C, report dated November 3, 2000. 2. Fred Jalehician, Grading Plan, Lot 61 of Tract 21430-1, City of Temecula, Drawing No. 0101-1497GP, Sheet 1 of 2, plans undated. Dear Mr. & Mrs. Villa: According to your request and signed authorization, EnGEN Corporation has performed field observations, sampling, and in-place density testing at the above referenced site. Submitted, herein, are the test results and the supporting field and laboratory data. 1.0 SITE/PROJECT DESCRIPTION AND LOCATION 1.1 PROJECT LOCATION The subject site consists of Lot 61, located on the north side of North General Kearny Road in the City of Temecula, County of Riverside, California. J Mr. and Mrs. Julio Villa Project Number: T2189 -C ' May 2001 Page 2 ' 1.2 PROJECT DESCRIPTION It is understood that the subject site is to be developed with a single family residence with ' slab -on -grade concrete floors, supported on conventional continuous and pier footings, surrounded by parking and landscape areas. ' 1.3 SITE DESCRIPTION Prior to grading operations, topography and surface conditions of the site were relatively ' flat with surface drainage to the south at a gradient of less than 5 percent. 2:0' SCOPE OF WORK ' 2:1 TIME OF GRADING This report represents geotechnical observations and testing during the construction operations from May 9, 2001 through May 11, 2001. 2.1 CONTRACTOR AND EQUIPMENT The grading operations were performed by Blackmore Contracting through the use of one (1) CAT D6R track -mounted dozer and one (1) water truck. ' 2.2 GRADING OPERATIONS Grading within the subject site consisted of an overexcavation and replacement operation. Grasses and weeds were removed prior to fill placement. Over -excavation was performed in the entire structure area of the building pad to a depth of 3.0 -feet below finish grade elevation and to a distance of 5.0 -feet outside the proposed structure. Overexcavated earth material was stockpiled and later used as fill. Bottoms were observed, probed and found to be into competent bedrock by a representative of this firm. The exposed bottoms were scarified and moisture conditioned to a depth of 12 -inches then compacted to 90 percent. Fill was placed in lens thicknesses of 2 to 4 -inches, thoroughly moisture conditioned to near optimum moisture content, then compacted to a minimum of 90 percent relative compaction. Moisture conditioning of the on-site soils was performed during the compaction process, through the use of a water truck. The pad area was generally graded to the elevations noted on the Grading Plan. However, the actual pad location, dimensions, elevations, slope locations and inclinations, etc. were surveyed and staked by others and should be verified by the Project Civil Engineer. 0 EnGEN Corporation Mr. and Mrs. Julio Villa Project Number: T2189 -C ' May 2001 Page 3 ' 3'.0 TESTING 3.1 FIELD TESTING PROCEDURES ' Field in-place density and moisture content testing were performed in general accordance with ASTM D 2922-96 and ASTM D 3017-96 procedures for determining in-place density and moisture content, respectively, using nuclear gauge equipment. Relative compaction test results were within the 90 percent required for all material tested, which is an indication that the remainder of the fill placed has been properly compacted. Test results are presented in the Appendix of this report. Fill depths and test locations were determined from review of the referenced grading plans. 12 LABORATORY TESTING ' The following laboratory tests were performed as part of our services during the grading of the subject site. The test results are presented in the Appendix of this report. 3.2.1 MOISTURE -DENSITY RELATIONSHIP TEST Maximum dry density - optimum moisture content relationship tests were conducted on samples of the materials used as fill. The tests were performed in general accordance with ASTM D 1557-91 (98) procedures. The test results are presented in the Appendix (Summary of Optimum Moisture Content / Maximum Dry Density Relationship Test Results). 3.2.2 EXPANSION INDEX TEST A soil sample was obtained for expansion potential testing from the building pad area upon B completion of precise grading of the subject site. The expansion test procedure utilized was the Uniform Building Code Test Designation 18-2. The material tested consisted of silty sand with clay, which has an Expansion Index of 61. This soil is classified as having a medium expansion potential. The results are presented in the Appendix (Summary of Expansion Index Test Results). 3.2.3 SOLUBLE SULFATE TEST Soil samples were obtained for soluble sulfate testing from the building pad areas upon completion of grading of the subject site. The concentration of soluble sulfate was determined in general accordance with California Test Method 417 procedures. The test results are presented in the Summary of Soluble Sulfate Test Results exhibit. The test results indicate a low percentage of water soluble sulfates (0.0046% by weight), as a result no sulfate resistant concretes are necessary. 5 EnGEN Corporation 1 Mr. and Mrs. Julio Villa Project Number: T2189 -C ' May 2001 Page 4 ' 3.2.4 PLASTICITY INDEX Liquid limit and limit testing plastic was performed on samples of the material used as fill. The tests were performed in general conformance with ASTM D 4318-95a procedures. ' The material tested has a Plasticity Index of 10.4. The results are presented in the Appendix (Summary of Plasticity Index Test Results). t4:0: EARTH MATERIALS The natural earth materials encountered on-site generally consisted of silty sand with varying amounts of clay. 5!0 CONCLUSIONS AND RECOMMENDATIONS 5.1 FOUNDATION DESIGN RECOMMENDATIONS ' Foundations for the proposed structure may consist of conventional column footings and continuous wall footings founded upon properly compacted fill. The recommendations presented in the subsequent paragraphs for foundation design and construction are based on geotechnical characteristics and a medium expansion potential for the supporting soils and should not preclude more restrictive structural requirements. The Structural Engineer for the project should determine the actual footing width and depth to resist design vertical, horizontal, and uplift forces. 5.2 FOUNDATION':SIZE Continuous footings should have a minimum width of 12 -inches. Continuous footings should be continuously reinforced with a minimum of two (2) No. 4 steel reinforcing bars located near the top and two (2) No. 4 steel reinforcing bars located near the bottom of the footings to minimize the effects of slight differential movements which may occur due to minor variations in the engineering characteristics or seasonal moisture change in the supporting soils. Column footings should have a minimum width of 18 -inches by 18 -inches and be suitably reinforced, based on structural requirements. A grade beam, founded at the same depths and reinforced the same as the adjacent footings, should be provided across garage door openings and other doorway entrances. 5.3 DEPTH OF EMBEDMENT Exterior and interior footings founded in properly compacted fill should extend to a minimum depth of 18 -inches below lowest adjacent finish grade for the structure. The foundations should be founded in properly compacted fill with a minimum of 24 -inches of compacted fill below the bottom of the footings. L �D EnGEN Corporation Mr. and Mrs. Julio Villa Project Number: T2189 -C ' May 2001 Page 5 5.4 BEARING CAPACITY Provided the recommendations for site earth work, minimum footing width, and minimum depth of embedment for footings are incorporated into the project design and construction, the allowable bearing value for design of continuous and column footings for the total dead plus frequently -applied live loads is 1,500 psf for continuous footings and 1,500 psf for column footings in properly compacted fill material. The allowable bearing value has a factor of safety of at least 3.0 and may be increased by 33.3 percent for short durations of live and/or dynamic loading such as wind or seismic forces. 5.5 SETTLEMENT Footings designed according to the recommended bearing values for continuous and column footings, respectively, and the maximum assumed wall and column loads are not texpected to exceed a maximum settlement of 0.5 -inches or a differential settlement of 0.25 -inches in properly compacted fill. 5.6 LATERAL CAPACITY Additional foundation design parameters based on compacted fill for resistance to static lateral forces, are as follows: Allowable Lateral Pressure (Equivalent Fluid Pressure), Passive Case: Compacted Fill - 150 pcf Allowable Coefficient of Friction: Compacted Fill — 0.30 Lateral load resistance may be developed by a combination of friction acting on the base of foundations and slabs and passive earth pressure developed on the sides of the footings and stem walls below grade when in contact with undisturbed, properly, compacted fill material. The above values are allowable design values and may be used in combination without reduction in evaluating the resistance to lateral loads. The allowable values may be increased by 33.3 percent for short durations of live and/or dynamic loading, such as wind or seismic forces. For the calculation of passive earth resistance, the upper 1.0 -foot of material should be neglected unless confined by a concrete slab or pavement. The maximum recommended allowable passive pressure is 5.0 times the recommended design value. `[ EnGEN Corporation ' Mr. and Mrs. Julio Villa Project Number: T2189 -C ' May 2001 Page 6 ' 5.7 SLAB -ON -GRADE RECOMMENDATIONS The recommendations for concrete slabs, both interior and exterior, excluding PCC ' pavement, are based upon the anticipated building usage and upon a medium expansion potential for the supporting material as determined by Table 18-1-B of the Uniform Building ' Code. Concrete slabs should be designed to minimize cracking as a result of shrinkage. Joints (isolation, contraction, and construction) should be placed in accordance with the American Concrete Institute (ACI) guidelines. Special precautions should be taken during ' placement and curing of all concrete slabs. Excessive slump (high water/cement ratio) of the concrete and/or improper curing procedures used during either hot or cold weather ' conditions could result in excessive shrinkage, cracking, or curling in the slabs. It is recommended that all concrete proportioning, placement, and curing be performed in taccordance with ACI recommendations and procedures. 5.8 INTERIOR SLABS Interior concrete slabs -on -grade should be a minimum of 4 -inches in actual thickness and be underlain by a minimum of 2 -inches of clean coarse sand or other approved granular material placed on properly prepared subgrade. Prior to placing concrete the subgrade should be flooded to attain a moisture content of at least 5 percent above optimum to a ' depth of 18 -inches. Minimum slab reinforcement should consist of No. 3 reinforcing bars placed 18 -inches on the center in both directions or a suitable equivalent as determined by ' the Project Structural Engineer. The reinforcing should be placed at mid -depth in the slab. The concrete section and/or reinforcing steel should be increased appropriately for anticipated excessive or concentrated floor loads. In areas where moisture sensitive floor covering are anticipated over the slab, we recommend the use of a polyethylene vapor barrier with a minimum 6.0 mil in thickness be placed beneath the slab. The moisture barrier should be overlapped or sealed at splices and covered by a 1.0 -inch minimum layer of clean, moist (not saturated) sand to aid in concrete curing and to minimize potential punctures. 5:9 EXTERIOR SLABS All exterior concrete slabs cast on finish subgrade (patios, sidewalks, etc., with the exception of PCC pavement) should be a minimum of 4 -inches nominal in thickness. 1 EnGEN Corporation 0 2 Mr. and Mrs. Julio Villa Project Number: T2189 -C ' May 2001 Page 7 ' Reinforcing in the slabs and the use of a compacted sand or gravel base beneath the slabs should be according to the current local standards. Subgrade soils should be moisture conditioned to at least 5 percent optimum moisture content to a depth of 18 -inches timmediately before placing the concrete. ' 5110 GENERAL Based on the observations and tests performed during grading, the subject site in the areas noted as test locations has been completed in accordance with the Referenced No. 1 Report, the project plans, and the Grading Code of the City of Temecula. The graded site, in the areas noted as graded, is determined to be adequate for the support of a typical residential development. Any subsequent grading for development of the subject property should be performed under engineering observation and testing performed by EnGEN Corporation. Subsequent grading includes, but is not limited to, any additional fill placement and excavation of temporary and permanent cut and fill slopes. In addition, EnGEN Corporation should observe all foundation excavations. Observations should be made prior to installation of concrete forms and/or reinforcing steel so as to verify and/or modify, if necessary, the conclusions and recommendations in this report. Observations of overexcavation cuts, fill placement, finish grading, utility or other trench backfill, pavement subgrade and base course, retaining wall backfill, slab presaturation, or other earth work completed for the development of subject site should be performed by EnGEN Corporation. If any of the observations and testing to verify site geotechnical conditions are not performed by EnGEN Corporation, liability for the safety and performance of the development is limited to the actual portions of the project observed and/or tested by EnGEN Corporation. 6.0 CLOSURE This report has been prepared for use by the parties or project named or described above. It may or may not contain sufficient information for other parties or purposes. The findings and recommendations expressed in this report are based on field and laboratory testing performed during the rough grading operation and on generally accepted engineering practices and principles. No further warranties are implied or expressed beyond the direct representations of this report. EnGEN Corporation I W ' Mr. and Mrs. Julio Villa Project Number: T2189-C ' May 2001 Page 8 ' Thank you for the opportunity to provide these services. If you should have any questions regarding this report, please do not hesitate to contact this office at your convenience. ' Respectfully submitted, E_rl Cor ration ►Jason D. Gardneer� ' Field Operations Manager ' JDG/OB:hh Distribution: (4) Addressee FILE: EnGEN/Reporting/C/T2189-C Villa Residence, Precise Grading EnGEN Corporation 10 I 1 1 1 1 1 1 APPENDIX: TEST RESULTS Mr. and Mrs. Julio Villa Project Number: T2189 -C Appendix Page 1 6nGGN Corporation It Mr. and Mrs. Julio Villa Project Number: T2189 -C Appendix Page 2 ' FIELD TEST RESULTS (Summary of Field In -Place Density Test Results) (Nuclear Gauge Test Method) (S. G.) = Subgrade/(F.G.) = Finish Grade Test No. Test Date (2001) Test Locations Depth Elevation (FT) Soil Type Max Density (PCF) Moisture Dry Content Density (%) (PCF) Relative Compaction (%) Required Compaction o ( /o ) J-1705--171 Overexcavation Area -1.5 Al 129.8 9.7 118.1 91.0% 90.0% 205-11 Overexcavation -2.0 Al 129.8 10.0 119.2 91.8% 90.0% 3 05-11 Overexcavation Area F.G. Al 129.8 8.4 119.6 92.1% 90.0% 4 05-11, Overexcavation Area F.G. Al 129.8 9.9 117.9 90.8% 90.0% 5 05-11 Overexcavation Area F.G. - Al 129.8 9.2 120.8 93.1 % 90.0% C 5 1 1 1 P■ U L FJ 1 EnGEN Corporation �� 1 1 1 1 1 1 1 Mr. and Mrs. Julio Villa Project Number T2189 -C Appendix Page 3 SUMMARY OF OPTIMUM MOISTURE CONTENT MAXIMUM DRY DENSITY RELATIONSHIP TEST RESULTS ASTM D1557-91 Soil Description (USCS Symbol) Soil Type Maximum Dry Optimum Moisture Content Expansion Soil Type Depth (FT) Density (PCF) (a/a) Silty Sand with Clay Brown (SM) Al 129.8 9.5 SUMMARY OF EXPANSION INDEX TEST RESULTS UBC 18-2 SUMMARY OF SOLUBLE SULFATE TEST RESULTS Soil Type Location % By Weight E-1 Structure Area 0.0046 SUMMARY OF PLASICITY INDEX TEST RESULTS ASTM D 4318-95a Soil Type Dry Density Moisture Moisture Expansion Soil Type Depth (FT) Structure Area Condition Condition 10.4 (pcf ) Index Before Test % After Test E-1 1.5 117.6 8.6% 18.2% 61 SUMMARY OF SOLUBLE SULFATE TEST RESULTS Soil Type Location % By Weight E-1 Structure Area 0.0046 SUMMARY OF PLASICITY INDEX TEST RESULTS ASTM D 4318-95a Soil Type Location LL PL PI E-1 Structure Area 30.1 19.7 10.4 \3 EnGEN Corporation APPENDIX: DRAWINGS Mr. and Mrs. Julio Villa Project Number: T2189 -C Appendix Page 4 EnGHN Corporation 1 0 /Volt, G. A t� 6 O P L V p6M pAee,1;56 6 Awl 0AOINC, PLAN `N100dLJ31' TR 21430--1 (1.or,5 5/-61) c/ to Y.5 ­Oq 8 /\10 _tc kFf - WA f, L a t ► r ,C t-OCAI1 O N t�t +rw e. a.y 6 tj Y 40 VP5 11, L r) I/ Q 5 KA �rrl f s F. y r 1� 155 r: A• , _.fes A J. .,,, Vill .�„•_. y'' /' �+ ter' 6PJ8�5 �6//Ott#%J AA6 4 FA0&f talelsp$6, fi(A po ' 0001"ka . CO r r -_w..._ r oration -it 4d1E4 ���r��ix�l�n�cz# EnGEN ifoa 4Y+r�1 I E 4 RE P01111 $1`11141� -N CO.NIPACTION .3 4V I Vu )r V/?AIN PIA IJ ��+ } •�; j� �. t�F�t�J���" NUMBER: . �"����=�� LEOAL E)EURIPTION. �'��(A 2.11 ����L04.04 ��w *-,n+rr• r.....�...'....+_.a.....«wwr...-�•......-:......-_..-..,+r-+:.......,-•...r-..�.:.yh•.._--w......�..+�.. .�.....-r:w�.-'-_•...w•v..._• y.,..:.:y.,..,�„r......:..r+ o . � CLIE r NAME: Jullo R��rI.i I Villa 'I r �« �� (y V ��,% ............w.....°,.._,�..��.,.,....w°.......�.r._..'•...�,r.« �-_--'^.......,..._--,..,...wa-,...w._..........:.....w.�.�.�_...•..-r_...«,-.,...-..,rw..,,.,,,..rr.►'..»°.r.�...._.�.M.•ww.. �.:,.,._.« ,.....+• :.vw-.+�....•w.�..•..�w , 1 Ab VPII lFrAP 0 tl 0,00� 1 __=--' LEGEND APPROXIMATE LOCA'tIUN OF IN-PLAGE DENSITY i.E!sr APPROXIMATE 8UT-1'UM ELEVATION '+r APpFZUXIMA l"E LIMI`i's OF 0UFR-5KCAVXtICUN t � }r f/ /�'' 1 ♦♦♦ / i , do) _ - '�,�i J t~ I �rFrl�1 - _ •w -,,• IAw, t 1� ,� 'A03, 6 A O e- tt _� � � } • � � � r �-..+.«.,.. w.�.,...,,,,,r .."-�r-'+•`w°r'«'i. .�.r.-w....r...•�•4.-..-.r,.n.� �..i.r�,... +.q,.F>...« wr t1� rrrMrr'i�►w+YnY�xr�S.+�v°rr�`"�►'t""'."'r`"`w'. """..� l � ..... r � � -w �. -._� r.._r_rw r�..w+..+_--a .rr_��. r�F.4.w�r..w�tin .rw- M_ �+_'.+wr-+.w_�.wr �.•�ww.•n yn• - � rr� �'�r�r.�^_+++wrw 11W� :.i�..n+P'.�'�r �MY•�Vrrn.+�w•�r.rw,bWl-W_'♦R Ytir'MY'�A.,lop • ("I or �• 1.o Iir 1 APP1 r pf ............ } 6d) r r J �\ Sc 0 WN -.��.ww.•...r rr�.+.r111br+-'►w'w'.i-W ".. Y•,R�r...__ `. _.•..r..wrt...rt.� .r^�+..r�r�iWr+: {.w.�wM..4rrY"r./ t,. # Aool", w A ._A J A A 1111,1111111111P C V, • ,r...r,o ,r i+'.v.'r•r +urwr.r Irr ' w-..w�..w..�_+..rr�._.+-.+•...._... r,..a..--�.. i I Wwwr..w'r w..+w r �rmzrr L 6- � .�Y ,� r r k A r < r� rryyw'�,r���WIT t• yfA fir,IV/ yf . r � q r• � UnderoroundServiceAlert �1 �� + M. '' •► '. I I /V I elk) till ( Vl� r, 1 �% � rs•..�..w....., w.rwwrw�rw; .rwr.ewr.' �� N 1'calif rOLL FREE .► - _� G A Yt�•{•_ 'yr vV W � � -�� r" (��P� `dl.� "� � � I � 1 + 1 � � I � � .� I T � _..�--.....,..,�,,,_ �,� � � r � r � e •r.- _ ' r" ; �� ''�', •� �w+' f� � ' � h hd ' tV f422m4l C 1 11 J Ai1A f ty 4 a..I t �6"( ION 0 2 y 0 01 IWO 11V10FIISING DAYS E.3EFOFIE YOU DIG 1 , a ... � n �.. � � .' V Y' .' � ,. �. � :. „T a .r t �' !' K' Fr• Ori REVI S ICS S 1 :A1C, U I3�..I��["H i�ARK SEALI I � �-- `< SCS X y Ur'� iyn By cr1ec-ked ByF Ai. 'mar rr, TEMECULA DET)AR-RaIEUr OF PUBLIGO WORK coin tr aic tar`IM �.. I �f Y 0 T I I z o n tat Nuns a I S OF J/ + �1°. ,.,�.._.,...�.��w y_.r.._......r,r+._..f.r..r...--�..-ww..•�r..°._.r ._.,^..rrr+."b.rw..'•r..►+.r.+•b•rr+.w- i -r»..'--.,.-...••.w...-,,y•w_„�-« y,'�f'r."9 �,.�..y.._�._.•�•-.r.+_. ._.._«. ,-.-.r. �,.,.a.._'....._ .� �..r^ .. nr...,+.-._..+.....mo�..w....r.......�.-,... .��._ �.�_._�._....•.-�..��...,....•..f,�._...,_,w.._-ww..r_..�._.._...�.._.r IpY��'.. . ..r.._...«_.w.-...r...-....�_ .- t` r..�...rr.«"�..__...._.. y,y * r o �r '•. ♦ J f�L? rrM'•rMr kN :rw 6.p 6ACCEPrEq B�I D�faspVc * Q) r 9 r?r� _ �I y' �.. r TRA D a -,.� _ __. �_. PRI/ ICtr�AL �..rI4,MI[ F R yrr _ .3 � "" � � / I r �' "ww,.r,..«r_. .yµwn rvaw _ __-w� ....r..�r.,...+•+...ry-. _.__.«�.. r *6.g� �...•_ �Y ' r ,+w...�.•�,r-•'.-• ..r_-..�-..� ...r_.w.«w.-._...__.-. w »•r - «..w� w rw-.wM-Ww-. t.•1�.' '., �... n.__rw.r "Rq1.' -r. +_w+r•.�r a-. ae�• . / \erIicatIt Wt 44 09 1. 0 d {A� r�N &18,J�)41 y¢° 9 4; '?1'. �' p' t' - . 1..'.+...-..n..--.,�..-......._-.-.�.,........,..»__..�......«...r.'- ,�IL.. R./r �.�.�,......-..+...........-_�.,.�.._._,...�.T.�.�r�.-.r�...,. _..... .Il � «i ..w....�.....�_......�. .....«,._.ter...• ....-.._._.�- ..., a�� ,'! }�' '1' / 4 �r Elre •ysrMai n. .. , NOW k+ J' y. {4 I