HomeMy WebLinkAboutTract Map 9833-3 Lot 6 Field Density Testing
,
REPORT of OBSERVATION
and FIELD DENSITY TESTING
for RESIDENTIAL GRADING
Lot 6; TR 9833-3
Ln 90-I17GR.
December 20,1999
Prepared for:
Mr. Robert Doyle
43399 Calle De Valardo
Temecula, CA 92590
Fax: (909) 926-1998
Prepared by:
Gunvant Thakkar, P.E.
45712 Classic Way
Temecula, California 92592
(909) 676-7541
\
GUNVANT THAKKAR,
PROFESSIONAL ENGINEER
45712 Classic Way, Temecula, California 92592 909)676-7541
December 20, 1999
Mr. Robert Doyle
43399 Calle De Valardo
Temecula, CA 92590
Fax: 926-1998
Project:
Compaction Testing & Report
Lot 6; TR 9833-3
Dean Mr. Doyle:
In accordance with your request, we have prepared this compaction report for the subject property.
The report represents a summary of the observations and compaction testing of the fill placed on
the slope repair. Field testing and observations indicate the compaction and grading of the soil was
performed properly. The soil should perform satisfactorily for the expected usage. The included
findiljlgs and recommendations have been derived in accordance with generally accepted
professional principles and practices in the fields of soil mechanics and foundation engineering.
This warranty is in lieu of all other warranties, either expressed or implied.
The opportunity to be of continued services is sincerely appreciated. If you should have any
questions or require further information, please contact me at your convenience.
7,-.
INTRODUCTION
In accordance with your request, tests have been performed on the fill placed on the slope repair.
The excavation, fill placement, compaction and testing associated with this phase of the grading
was performed in September, 1999. This report presents a summary of the testing services
provided.
PROJECT DESCRIPTION
The existing site has a single family residence with attached garage constructed on it with
associated landscaping and access drive. The fill slope was prepared for erosion control and
recompacted.
GRADING PROCEDURES
The observations and test results indicated that the grading was performed in the method
consistent with the U.B.C, as amended by Ordinance 457. All areas to receive fill were stripped and
c1eaEed of vegetation and soft soil prior to placement of soil fill.
Keying and benching into natural ground was completed in general compliance with the Uniform
Building Code, Appendix Chapter 33.
The minimum acceptable degree of compaction was 90 percent of the maximum density.
FIELD DENSITY TESTING
Field density testing was performed in accordance with ASTM D1556-64 (Sand Cone Method). The
results of the field density tests are presented in Table I of this report. The approximate location of
the tests are shown on the Plot Plan, Plate 1.
MAAIMUM DENSITY DETERMINATIONS
Maximum density / optimum moisture determinations were made from representative samples of
on-site soils used in the fill operations. The tests were performed in accordance with ASTM D1557-
78 Method.
'7
,
,
LIMITATIONS
The findings and recommendations of this report were prepared in accordance with contemporary
prindples and practices in the field of geotechnical engineering. No other warranty or guarantee is
either expressed or implied. Only a portion of the subsurface soils and conditions were evaluated or
observed and the conclusions are based upon an interpretation of the soils conditions encountered
in the field tests. Conclusions are also based on the assumption that these findings do not vary
appredably in the adjacent areas. However, minor variations may occur: should soil conditions
significantly different be encountered in the future, an assessment of the impact on subsequent
recommendations should be made.
All future grading and fill placement should be performed under the inspection and testing of a
registered civil engineer.
SUMMARY
Our description of grading and backfill operations, as well as testing services, were limited to those
grading operations performed in September, 1999. The conclusions and recommendations
contained herein have been based upon our observation and testing as noted. To the best of my
knowledge, the work within my area of responsibility is in accordance with applicable provisions of
U.B.C. as amended'by Ordinance 457.
~
-
GUNVANT THAKKAR, PROFESSIONAL ENGINEER
45712 Classic Way, Temecula, California 92592 (909) 676-7541
Mr. Doyle
Maximum Density Optimum Moisture Content
(pcf) (%)
129.5 10.5
Eleva-
Tion
(Feet)
Max. Dry
Density
(pcf)
Water
Content
(%)
Dry
Density
(pcf)
Relative Method
Compac-
tion (%)
1. Key 129.5 10.2 118.0 91 SC
2. Key 129.5 10.3 119.2 92 SC
3. 5 129.5 10.1 116.7 90 SC
4. 7 129.5 10.5 120.5 93 SC
5. 10 129.5 10.2 119.2 92 SC
6. FS 129.5 10.3 118.0 91 SC
7. FS 129.5 10.4 120.5 93 SC
-5
--
--
I
I
I
I
I
I
I
I
I
I
I
I
I
,
I
h
,~
I'~
:1
\, I',
'<I' I .~.
, I
~
I
-
\------"'--
\ --
\ --
--
\ --~~
, -~'
.... ------
\ - ---...a.
\ ---
--
'" ',,-
.'\" ~1>
\
,
\
\
",:0.
":;;'%.
~~~\.
'f:.~:.~.
"
-.,,:..
"",~
';';':"
..'!>o.....
.~
~
(S>
!
.;?'~.
....;.,
'~~:c.,c..
-, -
./r~l.
<~
/
~'f. /
--:~
\
\
\
'.~f
\
~<.~
~1",
A
"
~~
>lit'
\
,
'1:....
,
.'
: \ I '
, . ,," '\" i _".
\.\ III ~~ -",
\J...-e ..-"' 1-;: ....
\-.- !t~'-~\~fi~~ \
'\ ". /f~ "'.-~-f "--
" ',cZ .
.... I!f .~.
LEGEND
APPROXIMATE TEST LOCA nON
DATE: It 11 c I <) 5
TEST LOCATION PLAN
PLATE: I
06'( I e
(p
,
r~ SITE I
~l "l
\ / )
\~ t)
f. ~.,,------------
\ 1 ~9t'Y
\ 0 ~
\ . /
\ [I ~00~/
\ :r: <(0
\ ~I
\1?, ~}y/
.~ Vl 0'<- /
- 1~
"'-----..
\ ~4,.
. '0'
\
,
,
,
,
~\
\ ~
'-. ~\
'-. D.\
--~~\
,\
'\~
-?o"lo
~
.<
,
.>
I
,
N.T,S.
OATE: 1111.01')'3
SITE LOCATION PLAN
L-:
. ','
.
00'1: