HomeMy WebLinkAboutBridge Fencing � EXISTING SIGN ON ELECTROLIER Z
CL OVERLAND DRIVE 15+69..33 STA 23+50 ±
1-15 330+06-58 co
h�
Z
�j
72 13 14 15 16 17 18--- 19 20 Z� 22
23
OVERLAND RIVE 24 EXISTING ELECTROLIER
?S STA 25+25 ±
EXISTING SIGN ON ELECTROLIER 2
STA 12+25 _ ?6
1
BEGIN CHAIN LINK RAILING
STA 11 +19.00 NOTE: FENCE POST SPACING
SHALL BE 6'-0" MAX END CHAIN LINK RAILING
FROM STA 14+00 TO 17+00 STA 25+75.00
CONSTRUCTION NOTES
O CONSTRUCT
HAIN LINK BRIDGES ONLY RAILING
PER CALOUTH
SDE OF BOTHTRANS
PLAN : OVERLAND DRIVE BRIDGE STANDARD PLANS B11-52, CHAIN LINK RAILING
SCALE,: 1"= 100" TYPE 7 MODIFIED TO REFLECT POST
ANCHORAGE DETAIL AS SHOWN ON PLANS.
( 2) WHERE EXISTING ROADSIDE SIGNS WILL BE
OBSTRUCTED BY THE INSTALLATION OF THE NEW
CHAIN LINK RAILING, CONTRACTOR SHALL USE
STANDARD PLANS DRAWING RS4, MODIFIED (ONE
SIDE ONLY) MULTIPLE SIGN INSTALLATION DETAIL.
PROVIDE OPENING IN MESH TO ACCOMMODATE SIGN
u�
BRACKETS.
ti
CL
ti
RANCHO CA ROAD 262+96,05 ± co
1-15 263+13,92 ± W
ti
2
261 RANCHO 262 CALIFORNIA 263 ROAD /2�6 4 15 1
5
STANDARD PLANS
DATED DULY, 2002 , �
NB ENTRANCE RAMP �J'\ �p
RS4 ROADSIDE SIGNS TYPICAL 9
INSTALLATION DETAILS NO. 4 �
�
VICINITY MAP
81 1-52 CHAIN LINK RAILING TYPE 7 U���F� �s �
`s0 � NO SCALE
BEGIN CHAIN LINK RAILING � � ~ti
AT END OF EXIST END CHAIN LINK RAILING 9L F�
BARRIER STA 261+15-18 + EXISTING ELECTROLIER AT END OF EXIST
STA 262+45 ± BARRIER STA 264+17,46 ± O MARGARITA RD
O�
SNOALL BE 6TE* FENCE 0P
OST MAX
THROUGHOUT
LOCATION OF RANCHO
PLAN : B
CONSTRUCTION CALIFORNIA RD
RANCHO CALIFORNIA ROAD RIDGE
OVERLAND D R
SCALE: 1"= 40' LOCATION OF
CONSTRUCTION
RANCHO CALIFORNIA RD
Caltrans Encroachment Perm it Number: 08 - 06 — N — FN - 0024
...............
CONSTRUCTION RECORD DATE BY REVISIONS ACC'D DATE BENCH MARK SEA � ��E Designed By Drawn By Checked By /[ py Drawing Na.
------- SCALE � Q A Christopher Krler . Karen McParttand Jack Abcarlus RECaMMENDED BYE _L ✓ � DATES �� CITY [IF TEMECULA DEPARTMENT OF PUBLIC WORKS
12
Contractor Horizontal � e� �G � Plans Prepared Under Supervision Of /
Inspector
Varies
� �p 0459 7'^ = ACCEPTED BY. "V�- ➢ATE. 3-22-e(. BRIDGE FENCING PROJECT PW05-09
r" J ack AbCaY'lU5 Dq-te 2/22/06 WILLIAM G. HUGHES, DIRECTOR OF PUBLIC WORKS/CITY ENGINEER RANCHO CALIFORNIA ROAD OVERCROSSING BR, N0. 56-0655
Vertical $ "@ OVERLAND DRIVE OVERCROSSING BR. NOS. 56-0792 & 56C-0449
sl C(Vll ati� � '`
Sheet of
�°ta0"�'� e� Varies � y 9tf Of CA�t``�� R.C.E. No. 40459 Expires 3/31/07 R.C.E. No. 3661...7 Expires, 06/30/06 �;' GENERAL PLAN � 2
ILI,
LENGTH FOR PAYMENT OF CHAIN LINK RAILING TYPE 7 (MODIFIED) CL EXIST.
ELECTROLIER OR SIGN
g° 5'-01P M IN — 10`-0 19 MAX * A 51—0° MIN — 10'-0" MAX * I P—0 is 1$-0"
* FOR FENCE POST SPACING SEE 1'-0" SEE "SPLICE OR
"GENERAL PLAN" SHEET EXPANSION JOINT
DETAILto
CHAIN LINK RAILING 10 NZ XX
o 0 0 0 0 0 0 o O o 0 0
TYPE 7 (MODIFIED) �
-H BULGE FABRIC
FABRIC CONTINUOUS AT
EXPANSION JOINTS AND AT ELECTOLIER
0 ELECTROLIERS OPENING a
� 6'-0" WIDE, CHAIN LINK 0 FABRIC 1"' MESH. TS 3to X 2" X .1 875" SECURE FABRIC O
SEE "POST ANCHORAGE - KNUCKLED SALVAGE TOP (TYP ALL POSTS) TO INTERMEDIATE
DETAIL" BELOW C C AND BOTTOM POSTS WITH y"0
(A AA� HEX HEAD SELF—
NCHOR W6"O GALV CABLE AT PROVIDE OPENING IN TAPPING SCREWS o
END POSTS AND POST ADJACENT TO MESH AS REQUIRED WI TH YV X W" X
ELECTROLIER OPENINGS OR DECK OR 0'-1YV PL WASHER
N WALL JOINTS WITH STUD SOCKET @ 14" MAXL 3 YF X 92 X Y�
� 0 ASSEMBLY OR YFO WELDED EYE � OVER END POST
BOLT AND CRIMPED SLEEVE CLAMP. 7 GAGE TENSION WIRE
EXISTING No CLEAR PROVIDE 1)V MIN TAKEUP AT 9" M I N IN PANEL ACROSS
TYPE 25 TO ANGLE EACH ANCHORAGE. I EXPANSION JOINT
BARRIER _Xxxxls�
EYEBOLT 9 GAGE STEEL WIRE
TIES @ 12" TO TENSION
WIRE AND CABLE Vie" ¢ GALV CABLE
THREADED THROUGH
Vp 0 HOLES
TYPICAL SECTION ANCHORELECTROLIER BOLTS INTERMEDIATEIN POSTS
NO SCALE OMIT CHAMFER
AT ELECTROLIER
$ END POST DECK OR WALL JOINT ELECTROLIER OR SIGN
1X2., 2Y2. Z y2, ��.,
PL %so x 8)sx $)pRt ELEVATION, NOTES
� NO SCALE 1, RAILING ASSEMBLY EXCEPT CHAIN LINK
)02' '0 VENT HOLE � � CONNECTION DETAILS SIMILAR TO SECTION A—A FABRIC TO BE GALVANIZED AFTER FABRICATION.
TS So X 2" X .18 7 5" TWOLEGS } V2, POSTS SHALL BE VERTICAL AND EQUALLY SPACED.
OF ANGLE HEX HEAD
BOLT WITH PLAIN
� �� CO WASHER 3. RAILING SHALL CONFORM TO HORIZONTAL
r� �I HOLE FOR I � 2Y2' .H 021" AND VERTICAL ALIGNMENT. WHEN RAILING IS
THREADED ROD N PLACED ON A CURVED HORIZONTAL
L 4"X 3"X Y4' � L 4"X 3"X )/I ALIGNMENT WITH RADIUS OF 150' OR LESS,
THREAD TH E Yid��i CABLE THROUGH hipo
� �yl s" C A P P O
WELDED EYE RODS EMBEDDED 4" INTO THE
3/g� L � TOP OF THE CONCRETE PARAPET AND EQUALLY
MAX CLEAR CAP P � � SPACED TO LIMIT THE MIDORDINATE DISTANCE
PLAN VIEWw Q PL �"x2Y2'x0p-10%'" BETWEEN THE Xid0 CABLE AND THE CURVE
W X 1y)) SLOTTED 0
TO 1" MAXIMUM. HORIZONTAL ANGLE SHALL BE
HOLE IN ANGLE 3 Z X"O ROUND HEAD BENT TO CONFORM TO HORIZONTAL ALIGNMENT
Y8'0± CLEAR � � MACHINE SCREWS IF RADIUS IS 150P OR LESS AND MAY BE ON 10'
CL TACK WELD �"�l HEX in ? WITH �b" XlY2" X 0'-1Yz" CHORDS IF RADIUS IS OVER 150po
TS 3" X 2" X .1875" TS 3' X 2' a PL, WASHERS, LOCK WASHER
Yap NUT TO CAP PL OR X A 875��
DRILL AND TAP HOLE � AND HEX NUT@ 18" MAX 4. HORIZONTAL ANGLE SHALL BE CONTINUOUS
CHAIN LINK IN PL OVER NOT LESS THAN TWO INTERMEDIATE POSTS,
RAILING TYPE 7 EXCEPT THAT A SHORTER LENGTH IS PERMITTED
3Y2�� (MODIFIED) END POST ELEVATION SECTION A — A SECTION B — B AT EXPANSION JOINTS, ELECTROLIERS AND OTHER
MORTAR PAD NO SCALE NO SCALE NO SCALE RAIL DISCONTINUITIES.
LEVELING NUT — Y411 HEX HEAD 5, WHEN RAIL IS ON SLOPE, PLACE FABRIC PARALLEL
SELF-TAPPING SEE NOTE 9 TO SLOPE.
SCREWS WITH �Y2of LOCK WASHERS BOLTED ALTERNATIVE 5is2it 6. ALTERNATIVE DETAILS MAY BE SUBMITTED BY CON
Q 14" C-C MAX T S 311 X 211 C09P0 HEX HEAD BOLT V-0 HEX HEAD BOLT TRACTOR FOR ENGINEER'S APPROVAL.
ad �Y� 2 1Y2 X�DRILL AND BOND - X ,1g75�� WITH PLAIN AND LOCK WITH 2 PLAIN WASHERS,
4 — 99) 0 THREADED `O WASHERS AND HEX NUTS LOCK WASHER AND HEX NUT 7. SEE GENERAL PLAN FOR LIMITS OF CHAIN LINK
RODS IN 1)6" � HOLES I I 00 Y411 � FINGER TIGHT, PEEN RAILING TYPE 7 (MODIFIED).
6" DEEP i MIN THREADS
TYP 8. PROVIDE THIMBLES AT ALL CABLE LOOPS.
N 9. EXPANSION JOINT SAME DIMENSION AS EXPANSION
Old
EXISTING TYPE _ JOINT IN DECK OR WALL. INCREASE SLOTTED HOLE
25 BARRIER Ya^ 3LENGTH AND SPLICE BAR LENGTH CORRESPONDINGLY.L 31/2" X 21/2" X 1/4" � 2�i" X .5" X 0'-10Y4" SPLICE
BAR WITH V X 1" SLOTTED
y"0 GAL V 13/011 36"Jd"HOLES FOR BOLT.
ELEVATION TENSION ROD � ff HEX HEAD SEE NOTE 9
SELF TAPPING
POST ANCHORAGE DETAIL, SECTION C — C SCREWS WITH
LOCK WASHERS SPLICE OR EXPANSION JOINT DETAIL
NO SCALE NO SCALE @ 14" C-C MAX NO SCALE
Caltrans Encroachment Permit Number: 08 - 06 — N —,FN - 0024
CONSTRUCTION RECORD DATE BY REVISIONS ACC'D DATE BENCH MARK SCALE SEALS `� f� Designed By Drawn By Checked By /( YV
Drawing No.
Christopher Krier Karen McPartland Jack Abcarlus RECOMMENDED BY. _/ / � DATE. Y� 0� CITY 0 F TEMECULA DEPARTMENT OF PUBLIC WORKS
Contractor
Horizontal � �e G� � Plans Prepared Under Supervision Of
Inspector
Varies o.� 04� ACCEPTED BY, — `-- DATE. BRIDGE FENCING PROJECT PW05-09
-�2•DS`
Jack Abcarlus 2/22/06 RANCHO CALIFORNIA ROAD OVERCROSSING BR. NO. 56-0655
XP Date WILLIAM G. HUGHES.. DIRECTOR OF PUBLIC WORKS/CITY ENGINEER
➢ote fmpete7
Varies R.C.E. No. 40459 Expires 3/31/07 R.c.E. No. 36617 Expires 06/30/06 �,,,�;o CHAIN LINK RAILING TYPE 7 RETROFIT sheet z of 2
IIf