HomeMy WebLinkAboutGeotech Study Mar. 6, 1996~ ~~/,~,~~o,~;.~ ~.~.~:~~:~~~;~~~~ ~~~~,~~~~~~~.~-- ~ • Soll Engineering • Testing • ConshucMOn Mofe~lals Tesling • Inborafory TesHng • EnGEN Corporation •EnNronmeMolSltaAssessmenis•HazartlousMOteAo155tteCleanup• Environmenral and Georecbntcal Engfnee,tng Nerwork Corporation • specai inspecnoru • ceoayv • E~yineeer~ ceoagv • March 6, 1998 Max Harrison Westside City Associates I, LLC 41975 Winchester Road Temecula, Cal'rfomia 92590 (909) 693-1430 / FAX (909) 693-1429 RBgeMlflg: GEOTECHNICAL I GEOLOGICAL ENGINEERING STUDY - TPM 24086 Project Number. T1381-GS References: A. Updated Geotechnica! / Geological Engineering Study, Proposed Expansion of Existing Business Cerrter, Paroels 1 through 10 of Parcel Map 24085, Diaz Road, Temecula, Califomia. Prepared by EnGEN Corporadon, dated August 19, 1996, Projed NumberT1075-GS B. Fault Location Investigation, Existing Resficted Use Zone, Parcel Maps 24085 and 24086, City of Temecula, County of Riverside, Califomia. Prepared by EnGEN Corporedon, dated August 29, 1997. C. Schaefer Dixon Associates, Inc., RepoR on Geotechnical Investigafion, Assessmerrt District No. 155, Parce/ Map 24085, 24086, 21029, 21382, and 21383, Rancho CaliPomia, Riverside County, Califomia, dated June 7, 1989. D. Leighton and Associates, RepoR on Preiiminary Geotechnical Investigation, Proposed Industrial / Commercial Site West of Cherty Street and Diaz Road, A. D. No. 155, Rancho Califomia, Riverside County, California, dated June 23, 1986. Dear Mr. Harrison: EnGEN Corporation is currently scheduling the field e~loration and sampling operations for a Geotechniral Engineering Study of the referenced site. Based on the geotechnical work conducted by this firm and others (referenced above), unusual geotechnical conditions beyond that addressed for Parcei Map 24085 are not anticipated at this writing. The scope of work proposed for Parcel Map 24086 will be to locate potential anomalies in the subsurface conditions at the site that may require consideration for site earth work and foundation design criteria. We hope this is sufficient for your present needs. Please direct any questions to this office. Respectfully, EnGFlN~Coiporation • d H. Wayne B i bridge, R 002 -~' President ~ ~ n;:",:~ " ~`'"~' ~,iti.. ;; ;o ~~i~., E~ires 06-30-99 ~ HWB/OB:vjv Corponb OKCs d160] EnterD~se Circle North, Suite 1 TemecNa, CA 9259D Web-page address: www.engenrorp.com (909)6]63095/Faz:B]6-329< E-mailaddress: engencorpQpe.net - --~ Geotechnical Engineer : 09-30-2001 Onng~ Counry OMIu 2615 Oreige Avenue SanU Ane. CA 92]OP Q1<) 546~4051 I Faz:5C64052 ~ ' y~~:~~~i~~,~~~,~:~:~;~.~'ia~~~'i i~w~~~"~- II, ~ EnGEN Corporation •~il EngineeAng • Testing • Conshuctlon MoterlalsTestirg • LoborotoryTestirg • • Environmental Stte Aaessmenis • Hazartlous Matenats Site Cleonup • Environmental and Geotechnical Engineering Neduork Corpotatlon • speciai o-~wecno~s • c,aoioyy • en9ir,eenr,9 ceoi«.~y • ' ' ' ' t I' , ' t ' ~ , ' ' LosAngebsOlfice Pos~ Ofike Box 149] Lancostei, CA 93534 (BOS~ 9a0~ I 200 / F¢< 9d0-1202 ' GEOTECHNICAL REPORT OF ROUGH GRADING Lots 1-10 of Parcel Map 24085 Diaz Road, City of Temecula, Riverside County, Califomia Project Number: T1075-C A.P.N. 909-120-022 Prepared for: Westside City I Associates, LLC 41975 Winchester Road Temecula, Califomia 92590 Corporate Oftice omrge counN ollke 2615 orarge Avenue Santa Ma CA 92707 p14~ 546-4051 / Fmc 546-6052 41607 Enterprise Circle North, Suite 1• Temecula • California 92590 •(909) 676-3095 • Fa~c: (909) 67C3294 ~ , Westside City I Associates, LLC Projed No. T107SC ~ TABLE OF CONTENTS ~ Section Number And Title PAGE 1.0 PROJECT DESCRIPTION ............................................................................................................2 2.0 SITE DESCRIPTION ......................................................................................................................2 2.1 Location .................................................................................................................................2 2.2 Topography and Surface Conditions ....................................................................................2 3.0 SCOPE OF WORK .........................................................................................................................2 3.1 Time of Grading .....................................................................................................................2 3.2 Equipment .............................................................................................................................2 3.3 Grading Operations ............................................................................................................... 5 3.4 Cut 1 Fill Transitions 4.0 TESTING .................................................................................................................................5 4.1 Field Testing ..........................................................................................................................5 4.2 Laboratory Testing ................................................................................................................ 5 4.2.1 Moisture-Density Relationship Test,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, 4 4.2.2 Expansion Index Test,,,,,,,,,,,,,,,,, ,,,,,,,,, ,,,,,,,,, ,,,,,,,,, ................4 5.0 EARTH MATERIALS 1 AS GRADED GEOLOGIC CONDITIONS 6 ' ....................................... 5.1 Compacted Fill 5.2 Native Cut Areas , 6.0 CONCLUSIONS AND RECOMMENDATIONS,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,7 6.1 General 7 , 6.2 Erosion Control Measures .....................................................................................................8 7.0 CLOSURE .................................................................................................................................8 , APPENDIX: 'i ~ FIELD TEST RESULTS LABORATORY TEST RESULTS DRAWINGS ~ ~~ , EnGEN Carporation 3 ' ~~~~~:~:~.~;~f~,~,~.~:~~~;~~;`i;~.~~~.~:~.~-= ~„~-~ ......................_ _,....... ~ ~nV~1V ~OrpOra+l~n ' $oii Engirieenng • iesfing • Caufi~ction MateAolsTesting • LoborotoryTesting • ~• • EnNronmeMal Stte Assessrnents • Hazardous Mafenals Stte Cleonup • Environmental ancl Geotechnical EngirieeringNetwork Cotporation • Speciol Inspecfioru • Geology • Engineenng Geology • ~ November21, 1996 Mr. Max Harrison ~ Westside City Associates I, LLC 41975 Winchester Road Temecula, Califomia 92590 ~ (909) 693-1430 ~ Regarding: GEOTECHNICAL REPORT OF ROUGH GRADING Lots 1-10, Parcel Map 24085, Diaz Rd., City of Temecula, Riverside County, Califomia Project Number T1075-C ~ References: 1. Hector Correa, Rough GradingandErosion ControlPlan, Parcels 1-10 of Parcei Map 24085, Sheets 13 of 3, dated July 10,1996. 2. EnGEN Corporation, lntenm Repod of Set1/ement Monifonng, Grading Operations of Building Pad for Parcei 1 of Parcel Map 24085, Zevo Golf Building, City of Temecula, Riverside County, Califomia, Project No. T1075-C, dated October 10,1996. 3. EnGEN Corporation, Pavement Design RecommendaNons, Westside Business Center, Diaz Road Improvements -113+78.00 to 124+02, Project No. T1075-C,Report dated September 30,1996. 4. EnGEN Corporation, lntenm Repod of Sefflement Monifonng, Grading OperaG"ons of Building Pad for Parcel 1 of Parcel Map 24085, Zevo Golf Building, City of Temecula, Riverside County, Califomia, Project No. T1075-C, dated September 30,1996. 5. EnGEN Corporation, lnlenm Repo~t of Geotechnical Observafions and Tes6ng, Grading Operations of Building Pad for Parcel 1 of Parcel Map 24085, Zevo Golf Building, City of Temecula, Riverside County, Califomia, Project No. T1075-C, dated September 24,1996. 6. EnGEN Corporation, Updated Geotechnical I Geo%gicalEngineenng Study, Proposed Expansion of the Existing Business Center, Diaz Road, City of Temecula, Riverside County, RepoR dated August 19, 1996, Project No. T1075-GS. 7. GeoSoils Report, dated May 4, 1994, Supp/emenla/ Geotechnica/ /nvestigation of Lots 14 through 22, Phase 1 of Tenta6ve Parcel Map 24085, Temecula, Riverside County, Califomia; W.O. 686-A-RC 8. Schaefer Dixon Associates, Inc., Repo~ton ~eotechnicallnvesiiga6on, Assessment District No.155, Parcel Map 24085, 24086, 21029, 21382, and 21383, Rancho Califomia, Riverside County, Califomia, dated June 7,1989. 9. Leighton and Associates, Repod on Preliminary Geofechnical lnves6gafion, Proposed Industrial / Commercial Site West of Cherry Street and Diaz Road, A. D. No. 155, Rancho Califomia, Riverside County, Califomia, dated June 23,1986. Dear Mr. Harrison: According to your request and signed authorization, EnGEN Corporation has performed field observations, sampiing, and in-place density testing during the rough grading operations for the referenced site. Submitted, herein, are the results of the findings and the supporting field and laboratory data. , Los Mgeles orc~e Posl Onke Box 1 A9] Loncastet CA 93534 ~805~ 9A0-I 200 / F~: 9404 202 COTpOTdIC O~CC Oraige County Ofl~e 2615 Orariqe Avenue Sanfa Ma. CA 92707 p14~ 5a6-4051 / Fox: 546-A052 Q. 41607 Enterprise Cirde North, Suite 1• Temecula • California 92590 •(909) 6763095 • Faac: (909) 6763294 Westside City I Associates, LLC Project No. T1075-C November 96 Page 2 1.0 PROJECT DESCRIPTION The grading of the referenced site consisted of preparing 10 graded lots and associated streets for commercial 1 industrial sites. The referenced site was graded to the efevations as shown on the Reference No. 1 plan. 2.0 SITE DESCRIPTION 2.1. Location: The site encompasses approximately 65 acres and is located west of Diaz Road and north of Avenida De Ventas, in the City of Temecula, Riverside County, Califomia. 2.2 Leqal Description: Parcels 1 through 10 of Parcel Map 24085, County of Riverside (APN 909- 120-022). 2.3 Topoaraahv: The topography of the site before grading was relatively flat on the eastem portion of the property and gently to moderately sloping on the west side of the property. A portion of the west side of the property had been previously graded flat and some fill had been stockpiled immediately south of the graded pad. Drainage on the property was toward the northeast. 2.4 Veaetation: Before grading, vegetation across the site was light to moderate and consisted of seasonal grasses, weeds, and bushes. 2.5 Structures: Before grading, there were no existing buildings or other types of structures known to exist on the site. Heavy construc6on equipment was stored on the previously graded pad at the west portian of the property. 3.0 SCOPE OF WORK 3.1 Time of Gradinca: Grading operations were conducted from August 29, 1996 through November 11, 1996. I, ~ 3.2 Eauiament: The grading opera6ons for the lots on Parcels 1 through 10 and the associated streets were performed by American Contracting, Inc. through the use of 10 Terex and Caterpillar ~ EnGEN Corporation S` i ' ~ 3.3 Westside City I Associates, LLC Projed No. T1075-C November 96 Page 3 scrapers, three (3) Caterpillar Trackmounted dozer, two (2) Caterpillar rubber fire dozers, one (1) motorgrader and several water trucks. Gradina Oaerations 3.3.1 Parcel 1: Grading consisted of an overexcavation and replacement operation. Removal of previously existing fill and overexcavation of undisturbed native material (alluvium) was performed to depths determined, by a representative of EnGEN Corporation, in the field. The depth of removals ranged from 2.0 to 8.0 feet below original grade. To ensure a minimum of 10 feet of compacted fill below finish grade elevation, removal of alluvial material was performed to a minimum depth of 4.0 feet below native grade, in the building pad area, and to a distance of 5.0 feet outside proposed perimeter footings. Bottoms, once approved, were moisture conditioned to within 2.0 percent of optimum, processed, and compacted to a minimum of 90 percent relative compaction. Fills, approximately 8.0 feet to 15.0 feet, were placed and compacted to a minimum of 90 percent relative compaction. 3.3.2 Parcels 2 throuah 7: Grading consisted of a cut and fill operation. Excavations were made in the westem portion of each parcel to achieve proposed pad elevations. The materials obtained from the excavation were used to bring Parcels 1, 8, 9,10, the northem portion of Parcel 5, eastem portions of Parcels 2, 3, 6 and 7, Diaz Road between stations 114+50 through 123+00 and Remington Street between stations 10+50 through 17+50 and 26+50 through 39+00. Removal of existing undocumented fill material, slopewash, etc. was pehormed in the areas to receive compacted fill on each parcel prior to placing new fills. The depth of removals on each parcel ranged from approximately 1.0 to 5.0 feet as determined by a representative of EnGEN Corporation. Keys were excavated at the toe of the fill slopes on each parcel as shown on the Rough Grading Report Site Plan presented in Appendix III. The keys were excavated a minimum of 2.0 feet into firm, ~ EnGEN Corporetion Westside City I Associates, LLC Project No. T1075-C November96 Page 4 3.3.3 weathered and/or unweathered bedrock material and were a minimum of 15 feet in width. The limits of the overexcava6on, keys, fill placement, etc. are shown on the Rough Grading Report Site Plan. The overexcavated material was stockpiled and later used as fiil. The overexcavation bottoms were observed, probed, and approved as being in firm, competent materiai suitable for support of fill materials and proposed structure(s). Subgrade materials within the overexcava6on areas were scarified to a minimum depth of 12 inches below the exposed surface and recompacted to a minimum of 90 percent relative compaction. Fill material was placed in lens thicknesses of 6.0 to 8.0 inches and compacted to a minimum of 90 percent relative compaction. Moisture conditioning of the on-site soifs was performed during the compaction process due to the in-situ moisture content of the soils being below optimum moisture content. Benching into firm undisturbed native material was observed during placement of fiil. No import soils were used as fill during the rough grading operations. The parcels were generally graded to the elevations noted on the grading plan. However, the actual pad locations, dimensions, elevations, slope loca6ons and inclinations, etc. were determined by others and should be verified by the project Civil Engineer. Parcels 8. 9 and 10: Grading consisted of an overexcavation and replacement operation. Removal of previously existing fill and overexcavation of undisturbed native material (alluvium) was performed to depths determined, by a representative of EnGEN Corporation, in the field. The depth of removals ranged from 2.0 to 4.0 feet below original grade. Bottoms, once approved, were moisture conditioned to within 2.0 percent of optimum moisture, processed, and compacted to a minimum of 90 percent relative compaction. Fill material was generated from the westem cut portion of the project site to bring the subject parcels to finish grade elevation. Filis, approximately 7.0 to 9.0 feet, were placed and compacted to a minimum of 90 percent relative compaction. Fills were piaced and compacted using the same methods described in Section 3.3.2 of this report. ~ EnGEN Corporation Westside City I Associates, LLC Project No. T107SC November96 Page 5 3.4 CuUFill Transition: Overexcavation was not performed on the cut portion of Parcels 2, 3, 4, 5, 6 and 7. Therefore, cuUfill transitions exist on the subject parcels. It is recommended that overexcavation be performed in the cut portion of the parcels once proposed structure locations are determined. Overexcavation should be performed in accordance with the recommendations given in the Reference No. 6 report. 4.0 TESTING 4.1 Field Testinq: Field observafions and in-place density testing were performed on a full-time and part-time as-needed basis during the grading operations. Where tests indicate failing results, the soils were reprocessed until at least 90 percent relative compaction was achieved in the fill areas. Test Iocations were randomly selected in the areas receiving fill and were recorded using approximate locations and elevations as could be determined in the field. Field in-place density and moisture content testing were performed during the placement of the fill materials during the rough grading operations in general accordance with the following ASTM test procedures: Test Method for Density of Soil and Soil-Aggregate in Place by Nuclear Methods (Shallow Depths) - ASTM D2922-81(1990). Test Method for Water Content of Soil and Rock in Place by Nuclear Methods (Shallow Depth) - ASTM D3017-88. The test results indicate that soils were compacted to a minimum of 90 percent relative compaction.. Test results are presented in Exhibit I in Appendix I. The locations of the in-place density tests are presented on the Rough Grading Report Site Plan in the Appendix. 4.2 Laboratorv Testina: The following laboratory tests were performed as part of our services during the rough grading of the subject site. The test results are presented in the Appendix. 4.2.1 Moisture-Densitv Relationship Test: Maximum dry density - optimum moisture content ~ EnGEN Corpo2tion Westside City i Associates, LLC Projed No. T1075-C November 96 Page 6 4.2.2 5.0 5.1 5.2 rela6onship tests were conducted on samples of the materials used as fill. The tests were performed in generai accordance with ASTM D1557-91 procedures. The test results are presented in the Summary of Optimum Moisture Content / Maximum Dry Density Relationship Test Results. Expansion Index Testina: Soil samples were obtained for expansion potential testing upon completion of rough grading of the subject parcels. The expansion test procedure utilized was the Uniform Building Code Test Designation Standard 29-2. The material tested consisted of silty fine sand with minor amounts of clay, which had an Expansion Indexes of 22 and 50, corresponding to a low expansion potential in accordance with Table 29-C of the Uniform Building Code. The results are presented in the Summary of Expansion Index Results in the Appendix. As a result, construction recommendations for expansive soil purposes should be addressed on a Lot by Lot basis, so that it can be specifically tailored for each proposed structure. No special construction is required for the structure on Parcel 1 since the specified details for tilt-up construction exceed the design needs for expansive soils purposes. EARTH MATERIALS 1 AS GRADED GEOLOGIC CONDITIONS Filt Areas: The material used as fill was generated from cut areas on site and was observed to consist mainly of silty sands and sandy silts with some clay and intermittent gravels and some cobbles. Native Cut Areas: Geologic conditions encountered in native cut areas appeared to be similar to those described in the referenced geotechnical investigations. Pauba Forma6on bedrock consisting of sandstones, siltstones, sandstone - siltsone mixtures, along with scattered lenses of gravei and cobble are exposed in native cut pad and native cut slope areas on the site. Structurally, native cut areas are comprised of massive cuflfili channel deposits with occasional cross bedding and some q EnGEN Corporation Westside City 1 Associates, LLC Project No. T1075-C November 96 Page 7 6.0 6.1 signs of slightly dipping strata to the north-northeast. The cut slopes were evaluated during grading by an EnGEN Corporation Certified Engineering Geologist. Adverse geologic conditions that might affect gross siope stability were not encountered. Local areas that might affect su~ciai slope stability (erosion) were noted. It is recommended that a slope maintenance program (siope protecting vegetation) be implemented as soon as possible to prevent erosion of slope faces. In addition, the lower portion of the fiil over cut slope west of Lot 6 and a porlion of Lot 3 was observed to be saturated with groundwater. Therefore, a 4-inch diameter subdrain was installed at the toe of this slope (see plans) in order to exit excess amounts of water off the pad and slope areas. CONCLUSIONS AND RECOMMENDATIONS General: Based on the obseroations and tests performed during grading, the subject site in the areas noted has been completed in accordance with the project plans and specifications, the Grading Code of the City of Temecula. The graded site in the areas noted as rough graded is determined to be adequate for the support of a typical commercial structure and appurtenant facilities. Any subsequent grading for development of the subject property should be performed under engineering observation and testing performed by EnGEN Corporation. Subsequent grading includes, but is not limited to, overexcava6on of the cut portion of the transition area, and any additional fill placement and excavation of temporary and permanent cut and fill slopes. In addition, EnGEN Corporation should observe all foundation excavations. Observations should be made prior to installation of concrete forms and/or reinforcing steel so as to verify and/or modify, if necessary, the conclusions and recommendations in this report. Observations of overexcavation cuts, fill placement, finish grading, utility or other trench backfill, pavement subgrade and base course, retaining wall backfill, slab presaturation, or other earthwork completed for the development of subject site should be ~p EnGEN Corporadon Westside City 1 Aasociates, LLC Projed No. T1075-C November 96 Page 8 6.2 7.0 performed by EnGEN Corporation If any of the observations and testing to verify site geotechnical conditions are not performed by EnGEN Corporation, liability for the safety and performance of the development is limited to the actuai portions of the project observed and/or tested by EnGEN Corporation Erosion Control Measures: The graded pads are large and will generate significant runoff during rainy weather. Special precaution needs to be taken at the point of runoff discharge to prevent serious erosion at such points of runoff concentration. Care should be taken to protect ea~then berms along the tops of slopes near the discharge area so that these berms do not erode to such a degree that the drainage spilis onto the slope face. CLOSURE This report has been prepared for use by the parties or project named or described above. It may or may not contain sufficient information for other parties or purposes. The findings and recommendations expressed in this report are based on field and laboratory testing performed during the rough grading operation and on generally accepted engineering practices and principles. No further warranties are implied or expressed beyond the direct representations of this report. ~\ EnGEN Corporetlon 1 Westside City I Associates, LLC Project No. T1075-C November 96 ~ Page 9 Thank you for the opportunity to provide these services. If you should have any questions regarding this ~ report, please do not hesitate to contact this office at your convenience. ~ Respectfully submitted, EnGEN Corporation ~ ~j'~r E~~l ~~l''L ; ,~ason D. Gardner sbjom atene, 6 162 ~ Field Supervisor Proje eotechnical Engineer ~ / Exp. 9-30-97 . ,~',-y,A.13-+~~~~Nx .i-- C-~~„_. i / pFESS! omas E. LJewey, CEG 1975 ~ pP oN,~ Project Engineering Geologist Q`~c ppN e~*qT ~Fy , Exp. 11-30-97 (RG5542) ~ ~ ~ ~ ~~m m} •~ ~`~ ~ JDG/OB:sh ;i ~ N0. ~g~ *~I Distribution: (6) Addressee * C o-" i (1) Lusardi Construction sT ~oTpcH~~G~=-~f/ ~ File: D/EnGENIReportslCtt1075WYestside City Assoc. ~TF O~ r p'~ ~i~~ ~ ' ~ I , ~ ' I~ ~~!' EnGEN Corporation `Z Wesbide City I Associates, LLC Projed No. T1075-C APPENDIX FIELD TEST RESULTS (Summary of Field In-Place Density Test Results) ~3 EnGEN Corporetion Westside City I Associates, LLC Project No. T1075-C FIELD TEST RESULTS (Summary of Field In-Place Density Test Results) (Nuclear Gauae Test Method) T~~ No. Test Dale (1996) Test Loca6ons Depth Elev. (FT) ~~~ Ty~ Max Density (PC~ MoisNre Content (%) Dry Density (FC~ Relative Compaction (°~) Required Compaction (y,) 1 8/29 Fault Tmch Slot 1076' B 128.6 15.4 107.1 83.3 90 2 8129 Retestof#1 1016' B 128.6 12.0 118.0 91.8 90 3 8129 Cleanout#1 7019' 1 118.0 14.9 t06.0 89.8 90 4 8129 Cleanout #1 1019' 1 718.0 14.3 109.1 92.5 90 5 8129 Fault Tmch Slot 1018' B 128.6 13.9 1082 84.1 90 6 8-29 Retest pf #5 1018' B 128.6 13.0 119.8 93.2 90 7 8-29 Cleanout #1 1019' 1 118.0 12.1 110.7 93.8 90 8 8-29 Clleanout #3 1020' 1 118.0 12.4 106.8 90.5 90 9 8-29 Cleanout #3 1021' 1 118.0 11.4 110.1 93.3 90 10 8-29 Cleanout#1 1021' 1 118.0 11.6 111.9 94.8 90 11 8-29 Parcel #10 1022' 2 121.2 12.8 109.5 90.3 90 12 8-29 Parcel #10 1022' 2 721.2 14.0 110.9 91.5 90 13 8-29 Parcel #10 1023' 2 121.2 11.6 116.0 95.7 90 14 8-29 Parcel #1 7020' 1 118.0 11.9 112.7 95.5 90 15 8-29 Parcel #1 1022' 1 118.0 12.4 113.8 96.4 90 16 9-3 Parcel #10 1024' 2 1212 12.6 109.8 95.4 90 17 9-3 Parcel #10 1024' 2 121.2 11.9 110.9 95.4 90 18 9-3 Parcel #10 1025' 2 721.2 11.2 114.3 98.0 90 19 9-3 Parcel #10 1026' 3B 118.7 17.6 109.8 95.9 90 20 93 Parcel #10 1019' 2 121.2 12.0 111.3 96.1 90 21 9-3 Parcel #10 1026' B 128.6 12.1 118.0 95.1 90 22 9•3 Parcel #10 1027' B 128.6 10.9 116.0 90.0 90 23 9-3 Parcel #1 1013' 2 121.2 11.1 114.3 93.5 90 24 9-3 Parcel #9 1022' 38 t 18.7 11.3 112.9 92.1 90 25 9-3 Parcel #10 1027' B 128.6 112 122.9 91.5 90 26 9-4 Parcel #9 1023' B 128.6 11.9 116.3 93.3 90 27 9-4 Parcel #9 1023' B 128.6 12.3 115.7 97.4 90 28 9-4 Parcel #9 1024' 1 118.0 12.3 112.9 95.3 90 29 9-4 Parcel #9 1024' 1 118.0 13.3 114.1 97.5 90 30 9-4 Parcel#10 1025' 1 118.0 13.0 1t0.3 97.1 90 31 9-4 Parcel #9 1025' 1 118.0 12.0 112.0 952 90 32 9-4 Parcel #1 1020' 1 118.0 12.4 111.1 95.0 90 33 9-4 Parcei #1 1021' 1 118.0 13.0 109.0 99.3 90 34 9-5 Parcel #1 1022' 1 118.0 11.9 110.7 97.0 90 35 9-5 Parcel#1 1023' 1 118.0 12.6 109.0 83.1 90 36 9-5 Parcel #1 1023' 2 121.2 11.1 111.3 92.1 90 37 9-5 Parcel #1 1024' 2 121.2 11.8 116.0 95.4 90 38 9-5 Parcel #1 1016' 2 121.2 12.6 114.9 98.0 90 39 9-5 Parcel #1 1018' 2 121.2 11.0 116.7 95.9 90 ~~ EnGEN Corporation , Westside City I Associates, LLC ' Project No. T1075-C FIELD TEST RESULTS (Continued) , (Summary of Field In-Place Density Test Resul ts) (Nuclear Gauge Test Method) ' Test Depth Max Moisture Test Soi1 Dry Relative Required Density Content Date Elev. No. TestLocaGons T1'~ Density Compaction Compaction ~1996) (~ (PCF) (~,) (PC~ (%) (%) 40 9-5 Parcel #1 1020' 1 118.0 12.3 110.1 96.1 90 41 9-5 Parcel #1 1021' 2 121.2 13.3 111.7 95.1 90 42 9-5 Parcel #1 1026' 2 121.2 12.3 111.6 90.0 90 43 9-6 Parcel #1 1023' 3B 118.7 13.6 109.4 93.5 90 44 9-6 Parcel#1 1022' 3B 118.7 12.7 110.9 92.t 90 45 9-6 Parcel #1 1024' 1 118.0 11.0 1092 91.5 90 46 9-6 Parce; #1 1026' B 128.6 12.7 118.6 93.3 90 47 9-6 Parcel #1 1025' B 128.6 12.0 116.9 97.4 90 48 9-9 Parcel #1 1027' 2 1212 12.6 109.2 95.3 90 49 9-9 Parcel #1 1028' 2 121.2 152 112.6 97.5 90 50 9-9 Parcel #1 1029' B 128.6 16.0 116.2 97.1 90 51 9-9 Parcel #1 1030' 4 122.7 14.6 112.2 95.2 90 52 9-9 Parcel #1 1018' 3B 118.7 9.2 105.3 95.0 90 53 9-9 Parcel #1 1018' 36 118.7 11.0 104.7 93.5 90 54 9-10 Retest of #53 1018' 3B 122.7 14.5 114.5 92.1 90 55 9-10 Retest of #52 1018' 38 122.7 13.0 113.4 91.5 90 56 9-10 Parcel#1(pad) 1020' B 128.6 11.0 119.3 93.3 90 57 9-10 Parcel#1(pad) 1022' 3B 122.7 13.6 111.1 95.9 90 58 9-10 Parcel #1(pad) 1022' 3B 122.7 14.2 114.8 96.5 90 59 9-t0 Parcel#1(pad) 1023' B 128.6 13.1 116.6 95.9 90 60 9-11 Parcel #1(pad) 1019.5' 4 122.7 12.6 115.3 96.5 90 61 9-11 Parcel#t(pad) 1019' 4 122.7 12.1 112.9 95.1 90 62 9-11 Parcel#1(pad) 1020' B 128.6 11.7 118.3 97.9 90 63 9-11 Parcel#1(pad) 1020' B 128.6 11.2 118.0 95.1 90 64 9-11 Parcel#1(pad) 1020' B 128.6 13.3 123.0 92.5 90 65 9-11 Parcel#1(pad) 1021' B 128.6 13.0 117.6 84.1 90 66 9-12 Parcel#1(pad) 1028' B 128.6 8.0 121.5 94.5 90 67 9-12 Parcel#1(pad) 1024' B 128.6 11.9 115.9 90.1 90 68 9-12 Parcel#1(pad) 1025' 8 128.6 10.8 120.6 93.8 90 69 9-12 Parcel#1(pad) 1024' B 128.6 11.3 120.4 93.7 90 70 9-12 Parcel#1(pad) 1027' 2 121.2 13.8 109.6 90.4 90 71 9-12 Parcel#t(pad) 1027' 2 121.2 13.0 112.1 92.5 90 72 9-13 Parcel#1(pad) 1018.9' B 128.6 13.1 1t9.6 93.0 90 73 9-13 Parcel#t(pad) 1026' B 128.6 14.0 119.3 92.8 90 74 9-13 Parcel#1(pad) 1024' 4 122.7 13.7 114.8 93.6 90 75 9-13 Parcel#1(pad) 1025' 2 121.2 11.5 710.3 91.0 90 76 9-13 Parcel#1(pad) 1023' 8 128.6 11.8 119.8 93.2 90 77 9-13 Parcel#1(pad) 1028' 2 121.7 12.9 1t0.7 91.3 90 78 9-13 Parcel#1(pad) 1027' 2 121.2 13.1 109.9 90.7 90 / ~~ EnGEN Corporation r Westside City 1 Associates, LLC ' Project No. T1075-C ~ FIELD TEST RESULTS (Continued) (Summary of Field In-Place Density Test Results) (Nuclear Gauge Test Method) , Test Depth ~i~ Max Moisture Dry Relative Required Test Dale Elev. Densiry Content Densiry Compadion Compaciion No. (1996) Test Loca6ons (~ TY~ (PC~ (qo) (PC~ (%) (%) , 79 9-16 Parcel#1(pad) 1027.5' 5 130.7 9.9 122.3 93.6 90 80 9-16 Parcel #1(pad) 1022.3' B 128.6 13.0 117.1 91.1 90 Bi 9-16 Parcel #1(pad) 1030.6' B 128.6 11.0 116.2 90.4 90 , 82 9-16 Parcel #1(pad) 1030.6' B 128.6 11.9 120.7 93.8 90 83 9-16 Parcel#1(pad) 1030.6' 2 1212 11.6 109.2 90.1 90 84 9-16 Parcel#t(pad) 1030.6' 2 121.2 12.9 113.7 93.8 90 ' 85 9-16 Parcel#1(pad) 1030.6' 8 128.6 10.8 119.4 92.8 90 86 9-16 Parcel#1(pad) 1030.6' 2 1212 10.7 110.3 91.0 90 87 9-16 Parcel#1(pad) 1030.6' 4 1222 11.7 113.4 92.4 90 , 88 9-17 Par.#1(drv mg) 1021' B 128.6 10.9 118.3 92.0 90 89 9-17 Par. #1(drv mg) 1021' 5 130.7 12.7 1212 92.7 90 90 9-17 Pac #1(drv mg) 1022' 8 128.6 13.3 118.9 92.5 90 91 9-17 Par. #1(drv mg) 1021' B 128.6 12.0 120.6 93.8 90 , 92 9-17 Par. #1(drv mg) 1021' B 128.6 11.1 119.3 92.8 90 93 9-17 Par. #1(drv mg) 1022' 5 130.7 10.6 122.0 93.3 90 94 9-18 Par. #i(drv mg) 1023' 5 130.7 12.2 122.2 93.5 90 , 95 9-18 Par. #1(drv mg) 1023' B 128.6 72.5 118.6 92.2 90 96 9-18 Par. #1(drv mg) 7022' 7 129.2 10.9 123.7 95.7 90 97 9-18 Parcel#1(pad) 1030.6' 2 1212 10.2 111.7 922 90 ~ 98 9-18 Parcel#1(pad) 1030.6' 7 129.2 10.3 120.4 93.2 90 99 9-18 Par. #1(drv mg) 1023' 7 1292 9.3 119.6 92.5 90 100 9-18 Remington Ave. 1021' B 128.6 8.1 120.9 94.0 90 , 101 9-18 Par. #1(drv mq) 1024' 4 122.7 10.3 113.7 92.7 90 702 9-18 Remington Ave. 1020' B 128.6 12.3 118.6 92.2 90 103 9-18 Par. #1(drv mg) 1025' B 128.6 12.4 118.3 92.0 90 , 104 9-18 Remington Ave. 1022' 7 1292 10.0 121.3 93.9 90 105 9-18 Diaz Rd(120+50) 1019.4' B 128.6 14.7 119.7 93.1 90 106 9-18 DiazRd(118+50) 1019.4' B 128.6 15.5 113.5 88.3 90 ~ 107 9-18 Diaz Rd(116+00) 1018.8' 1 118.0 12.0 113.5 90.5 90 108 9-18 Diaz Rd(118~00) 1018.4' B 128.6 11.7 1167 90.7 90 109 9-18 Par. #1(drv mg) 1026' 6B 125.4 11.8 115.6 92.2 90 ~ 110 9-18 Par. #1(drv mg) 1026' 6B 125.4 12.9 114.8 91.5 90 111 9-20 Rem.Ave.30a90 1023' B 128.6 11.0 117.4 91.3 90 112 9-20 Par. #1(drv mg) 102T 4 122.7 15.0 110.7 90.2 90 113 9-20 Par. #1(drv mg) 102T 4 122.7 14.1 112.3 91.5 90 , 114 9-20 Rem.Ave.32+25 1023' B 128.6 10.1 119.8 93.2 90 115 9-20 Par. #1(drv mg) 1028' 4 122.7 12.2 111.3 90.7 90 116 9-23 Par.#t(drv mg) 1028' S 130.7 7.9 124.1 95.0 90 , 117 9-23 Par. #t(drv mg) 1029 5 130.7 8.8 123.0 94.1 90 ' , EnGEN Corporetion \6 r Westsi de City I Associates, LLC ' Project No. T1075-C FIELD TEST RESULTS (Continued) ~ (Summary of Field In-Place Density Test Results) (Nudear Gauge Test Method , Test Oepth Max Moisture ~ ~ Dry Rela6ve Required Test Date Elev. Density Content ~ Density Compaction Compaction N0. (1996) Test LOC260nS (~ TYPe (PC~ (%) (PCF) (%) (%) ~ - 118 9-23 Par. #1(drv mg) 1029' S 7307 9.1 119.0 91.0 90 119 9-23 Par.#1(drv mg) 1030' 6 127.6 10.3 115.1 90.2 90 120 9-23 Par. #1(drv mg) 1030' 6 127.6 10.9 114.8 90.0 90 121 9-23 Par. #t(drv mg) 1030' 6 127.6 9.1 116.8 91.5 90 122 9-23 Rem.Ave(35+00) 1024' 6 127.6 11.0 118.0 92.5 90 123 9-24 Par. #t(drv mg) 1025' 4 122.7 12.0 110.9 90.4 90 124 9-24 Par.#1(drv mg) 1026' 6 127.6 10.3 117.9 92.4 90 125 9-24 Par.#1(drv mg) 1028' 6 127.6 9.0 119.1 93.3 90 126 9-24 Diaz Rd(115.fi0) 1019' 6B 125.4 7.4 118.9 94.8 90 127 9-24 Diaz Rd(117+00) 1020' 6B 125.4 7.8 118.3 94.3 90 128 9-24 Diaz Rd(118+75) 1021' 6B 125.4 8.4 119.5 95.3 90 129 9-24 Diaz Rd(120+50) 1022' 6B 125.4 8.1 117.9 94.0 90 130 9-25 Diaz Rd(116+00) 1019' 68 125.4 10.5 119.6 95.4 90 131 9-25 ~iaz Rd(117+20) 1021' 6B 125.4 12.0 117.6 93.8 90 132 9-25 Diaz Rd(119-00) 1022' 68 125.4 11.1 118.0 94.1 90 133 9-25 Rem.Ave.27•50 1020' 4 122.7 11.9 115.0 93.7 90 134 9-25 Rem.Ave.29+50 1022' 68 125.4 10.1 119.9 95.6 90 135 9-25 Rem.Ave.28.60) 1023' 68 125.4 112 120.9 96.4 90 136 9-25 Remington Ave. 1024' 6B 125.4 10.3 120.0 95.7 90 137 9-25 Rem.Ave.(282) 1025' S 130.7 10.7 124.3 95.1 90 138 9-25 Parcel #3(Fill) 1046' 6B 118.0 16.5 106.3 90.1 90 139 9-26 Par. #1(drv mg) 1028' 6 127.6 12.0 120.0 94.0 90 140 9-26 Par. #1(drv mg) 1029' 6 127.6 12.0 1192 93.4 90 141 9-26 Parcel #8 &#9 1021' 6 127.6 9.9 121.1 94.9 90 142 9-26 Parcel#7 1022' 4 122.7 11.0 115.0 93.7 90 143 9-26 Parcel #8 1022' 4 122.7 102 116.9 95.3 90 144 9-26 Parcel#8 1023' 4 i22.7 9.6 118.0 962 90 145 9-26 Parcel#3(upper) 1048' 5 130.7 9.2 124.0 94.9 90 146 9-26 Parcel #3(lower) 1050' S 130.7 9.0 125.1 95.7 90 147 9-26 Parcel#7 1024' 1 118.0 13.3 107.2 90.8 90 148 9-27 Parcel#8 1024' 4 122.7 14.0 110.7 90.2 90 149 9-27 Parcel #7 1026' 8 128.6 8.3 116.0 902 90 150 9-27 Parcel #8 1025' 6 127.6 12.1 115.5 90.5 90 151 9-27 Parcel #7 1028' 7 1292 7.0 121.5 94.0 90 152 9-27 Parcel #8 1025.6' 6 127.6 11.9 114.9 90.0 90 153 9-30 Parcel #8 1024' 2 121.2 12.0 111.0 91.5 90 154 9-30 Parcel #7 1030' 6 127.6 10.2 115.6 90.6 90 155 9-30 Parcel #8 1024.5' 4 t22.7 11.0 114.8 93.6 90 156 9-30 Parcel #8 1024.5' 6 127.6 9.0 116.7 91.4 90 ~~ EnGEN Corporeqon ', Westside City I Associates, LLC I , Project No. T107SC FIELD TEST RESULTS (Continued) ' (Summary of Field In-Place Density Test Resul ts) (Nuclear Gauge Test Method) , Test Depih Max Maslure Soil Dry Relative Required Test Date E~y~. Density Cantent Density Compaction CompacYion No. (1996) Test Locations (~) TYPe (p~~ ~%) ~p~~ (ya) ~q,) ^ _ 157 9-30 Parcel #8 1025' 6 127.6 7.4 117.4 92.0 90 158 9-30 Parcel #8 1020' 2 121.2 12.1 111.6 92.1 90 159 9-30 Parcel #8 1026' 2 121.2 9.0 112.4 92.7 90 160 9-30 Parcel #8 1026.5 B 128.6 10.7 119.7 93.1 90 161 10-t Parcel #8 102T 6 127.6 9.0 114.8 90.0 90 162 10-1 Parcel #9 1026' 6 127.6 10.6 113.0 88.6 90 163 10-1 Parcel #9 102T 4 122.7 12.0 111.9 91.2 90 164 10-t Retest of #162 1027' 6 127.6 9.1 115.7 90.7 90 165 10-1 Parcel q8 1028' 7 129.2 9.4 121.4 94.0 90 166 10-1 Parcel #7 1028' 7 129.2 10.8 121.6 94.1 90 167 10-1 Parcel #7 1029' 7 129.2 9.0 123.0 95.2 90 '168 10-2 Parcel #8 1029' 4 1227 4.0 112.1 91.4 90 '169 10-2 Parcel#8 1030' 4 122.7 6.0 106.9 87.1 90 '170 10-2 Retestof 1030' 4 122.7 10.0 112.8 97.9 90 '171 16-2 Parcel #7 1033' 4 122.7 5.7 111.6 91.0 90 `t72 10-2 Parcel#8 1031' 7 129.2 11.0 121.9 94.3 90 173 10-3 Parcel #5 102T 7 129.2 9.7 119.9 92.8 90 174 10-3 Remington Ave. 1061' 7 129.2 8.9 121.1 93.7 90 175 10-3 Remington Ave. 1029' 7 129.2 7.9 121.3 93.9 90 176 10-3 Parcel #5 1056' 7 129.2 9.9 120.4 93.2 90 177 10-3 Parcel#5 1058' 7 1292 10.5 122.1 94.5 90 178 10-3 Parcel #5 1062' 7 1292 10.6 110.2 85.3 90 179 10~ Parcel #5 1066' 4 122.7 9.7 111.5 90.9 90 180 10-4 Parcel #9 1025' 4 122.7 10.4 112.2 91.4 90 181 10~ Retest of #178 1062' 7 129.2 11.1 119.8 927 90 182 10~1 Parcel #9 1026' 7 129.2 10.6 116.9 90.5 90 183 10-0 Parcel #5 1067' 7 129.2 8.9 117.3 90.9 90 184 10-7 Parcel #9 1027' 7 129.2 11.1 118.5 91.7 90 185 10-7 Parcel #5 1062' 4 122.7 11.9 111.7 89.1 90 186 10-7 Parcel #5 1064' 4 122.7 10.6 110.5 90.1 90 187 10-7 Parcel#5 iW0' 7 129.2 9.1 117.0 90.6 90 ~gg NoTest 90 189 10-7 Parcel #9 1026' 6B 125.4 8.1 174.0 90.9 90 190 10-7 Parcel#5 1068' 68 125.4 10.8 116.4 92.8 90 191 10-8 Parcel #5 1072' 68 125.4 8.0 118.0 94.1 90 192 10~ Parcel #9 1030' 7 129.2 9.9 113.5 96.6 90 193 10-8 Parcel#8 1024' 7 129.2 7.6 119.1 92.2 90 194 10-8 Parcel #5 1070' 6 127.6 9.8 116.6 91.4 90 795 10-8 Parcel#8 1026' 6 127.6 9.4 116.1 91.0 90 ~a EnGEN Corporetion , Westside City i Associates, LLC I' Project No. T1075-C ~ , FIELD TEST RESULTS (Continued) (Summary of Field In-Place Densiry Test Resuits) (Nudear Gauge Test Method) T~~ No. Test Date ~19~~ TestLoca6ons Depth Elev. (~~ Soi1 Ty~ Max Oensity (PC~ Moisture Content (%) Dry Density (PCF) Rela6ve Compaction (%) Required Compadion (%) 196 10-8 Parcel #8 1024' 6 127.6 11.6 118.2 92.7 90 197 10-9 Parcel #9 1023' 6 127.6 9.7 117.4 92.0 90 198 10-9 Parcel #8 1028' 6 127.6 12.7 114.2 90.0 90 199 10-9 Parcel#8 7028' 3B 118.7 14.5 109.9 92.6 90 200 10-9 Parcel#8 1029' 6 127.6 11.5 117.7 92.2 90 201 10-9 Parcel #8 1031' 6 127.6 9.8 114.6 90.0 90 202 10-9 Parcel #9 1029' 7 129.2 12.5 116.8 90.4 90 203 10-9 Parcel #9 1029' 6 127.6 11.4 116.1 91.0 90 204 10-9 Rem.11+50 1063' 7 129.2 10.9 116.8 90.4 90 205 10-9 Rem.15100 1065' 7 129.2 11.6 1167 90.3 90 206 10-9 Parcel #6 1055' 6 127.6 11.0 114.1 90.2 90 207 10-9 Parcel #6 1058' 6 127.6 10.3 118.0 92.5 90 208 1040 Pac3 Cyn Area 1053' 6 127.6 13.5 107.6 867 90 209 1040 Retest 208 1053' 6 127.6 12.7 116.1 91.0 90 210 10-10 Parcel #3 1054' 2 121.2 11.1 111.3 91.8 90 211 10-10 Parcel #3 1055' 2 121.2 12.6 113.3 93.5 90 212 1D-10 Parcel#9 1025' 2 121.2 16.2 1112 91.2 90 213 10-10 Parcel#3 1055' 2 i21.2 14.5 107.8 89.0 90 214 70-10 Parcel#3 1056' 2 121.2 17.0 108.7 90.0 90 215 10-10 Retest 213 1055' 2 121.2 16.4 1097 90.5 90 216 10-10 Par.3 Slp shouldr . 1056' 2 121.2 7.9 113.7 93.8 90 217 10-10 Par. #9 SE q1030' 6 127.6 11.5 120.0 94.0 90 278 10-10 Par. 8 Middle 1029' 6 127.6 7.8 116.0 90.9 90 219 10-11 Rem.Sta 28+50 1028' 4 122.7 11.4 113.2 92.3 90 220 10-14 Par. #9 SW 1030' 7 1292 6.1 119.0 92.1 90 221 10-14 Par.#8 1030' 7 129.2 6.7 119.8 92.7 90 222 10-14 ParB&9 Mid Bor. 1028' 7 129.2 10.1 122.0 94.4 90 223 10-15 Par.3 SE Com. 1050' 4 122.7 11.9 117.6 95.9 90 224 10-15 Parcel #9 South 1030' 4 127.6 14.9 115.0 90.1 90 225 10-15 Parcel #10 West 1026' 4 127.6 7.9 124.5 97.6 90 226 10-15 Parcel #9 East 1027' 4 127.6 8.6 122.1 95.7 90 227 10-16 Pac 9610 Center 1028' 68 125.4 9.7 1132 90.2 90 228 10-16 Parcel #8 SW 1030' 68 125.4 8.8 115.1 91.8 90 229 10-16 Parcel #8 SE 1030' 68 125.4 9.8 117.1 93.4 90 230 10-16 Parcel #9 Mid 1030' 68 125.4 9.1 117.9 94.0 90 231 10-22 Parcel #10 S 102T 7 7292 8.4 118.7 92.0 90 232 10-22 Parcel #10 Cv E 1026' 6B 125.4 9.8 113.2 90.3 90 233 10-22 Parcel #10 NW 1027' 7 129.2 7.8 123.5 95.6 90 234 10-22 Par.10 Wto Ctc 1027' 6B 125.4 8.9 116.7 93.1 90 235 10-22 Par. 3 E Slope 1050' 6 127.6 9.0 115.1 902 90 236 10-29 Parcel #9 E 1030' 68 125.4 11.0 112.8 90.0 90 237 10-29 Parcel #9 CV 1031' 68 125.4 5.9 117.7 93.8 90 238 10.29 Parcel #9 W 1031' 68 125.4 6.5 120.8 96.4 90 ~~ EnGEN Corporation '~ , ' ' ' est No. est Date (1996) st Locations Westside City I Associates, LLC Projed No. T1075-C FIELD TEST RESULTS (Continued) (Summary of Field In-Place Density Test Results) (Nuclear Gauge Test Method) Depth ~.~ Max Moisture Dry Relative Required Elev. Density Content Density Compaction Compaction (~) TY~ (PCF~ (~e) (PC~ (%) (%) 239 10-29 Parcel #9 SW 1032' 6B 125.4 7.4 113.7 90.7 90 ' 240 10-29 Par.S Upper Cyn 1075' 6B 125.4 7.8 1142 91.1 90 241 10-29 Parcel #5 NW 1073' 68 1292 5.9 125.3 97.0 90 242 10-29 Parcel #5 SW 1073 68 125.4 5.6 114.6 91.4 90 ' 243 11-5 Zevo Dr 11+00 1082' 68 125.4 12.2 111.7 90.0 90 244 11-5 2evo Dr 13~20 1078' 68 125.4 13.3 112.2 90.0 90 245 11-5 Zevo Dr 15+50 1073' 6B 125.4 13.1 116.1 92.6 90 ' 246 11-5 Zevo Dr 18+80 1061' 6B 125.4 10.9 116.5 92.9 90 247 11-5 Par. 8 NE cmr 1031' 6 127.6 14.9 104.8 82.1 90 248 11-5 Parcel #8 CV 1033' 6 127.6 11.7 118.2 92.6 90 249 11-5 Par. 8 W Ctr 1034' 6 127.6 12.2 118.7 93.0 90 ' 250 11-5 Win.RNZevo Dr 1084' 6 127.6 10.1 114.8 90.0 90 251 11~ Retest247 1031' 6 127.6 8.0 124.7 97.6 90 252 11$ Par.6 E Slope 1057' 6 127.6 7.8 117.6 92.2 90 ~ 253 11-11 Parcel #3 1058' 6 127.6 7.9 114.9 90.0 90 254 11-11 Parcel #3 1055' 6 127.6 10.2 115.7 90.7 90 255 11-11 Parcel#3 1057' 6 127.6 9.0 115.1 90.2 90 ' 256 71-11 Parcel #6 1057' 66 125.4 8.1 116.9 93.2 90 257 11-11 Parcel #6 1059' 6 127.6 8.0 118.4 92.8 90 258 11-11 Parcel5/4 1076' 6 127.6 9.4 117.6 92.2 90 ' 259 it-it Rem.10+80 1068' 6 127.6 9.8 115.5 90.5 90 260 11-11 Rem.11~0 1071 6 127.6 10.6 118.9 93.2 90 ~ ' ' (BG) i ndicates Base Grade. (SG) i ndicates Sub Grade (SM) i ndicates -ASTM Soil Type ' (AB) indicates - Aggregate Base 'indicates-Sand Cone test ' , ' EnGEN Corporetion ~ Westside City I Associates, LLC Projed No. T1075-C LABOR,4TORY TEST RESULTS (Summary of Optimum Moisture Content / Maximum Dry Density Relationship Test Results) (Summary of Expansion index Test Results) ~ EnGEN Corporation Westside City I Associates, LLC Project No. T1075-C SUMMARY OF OPTIMUM MOISTURE CONTENT / MAXIMUM DRY DENSITY RELATIONSHIP TEST RESULTS ASTM D1557-91 SOIL TYPE SOIL DESCRIPTION. (USCS Symbol) B Brown Silty Sand(SM) 1 Dark Brown Silty Fine Sand (SM) 2 Brown Sandy Silt (ML) 3 Brown Sandy Silt (ML) 4 Dark Brown Sandy Silt (ML) 5 Brown Silty Sand (SM) 6 Dark Brown Silty Sand (SM) 6B Brown Silty Sand w/Clay (SM) 7 Brown Fine to Coarse Sand (SM) 8 Brown Silty Sand (SM) MAXIMUM OPTIMUM DRY DENSITY MOISTURE CONTENT (PCF) (%) ~2a.s 118.0 121.2 118.7 122.7 130.7 127.6 125.4 129.2 132.4 9.5 13.0 13.3 13.9 12.4 8.5 9.7 10.7 8.5 8.1 2v EnGEN Corporetion Westside City I Associates, lLC Project Na. T1075-C SUMMARY OF EXPANSION INDEX TEST RESULTS (UBC 29-2) SOIL DRY MOISTURE CONDITION EXPANSION TYPE DEPTH SURCHARGE DENSITY BEFORE TEST AFTER TEST INDEX (FT) (PSF) (PCF) (%) (°/a) Parcels No. 1. 7. 8 and 9 1 1.5 144 97.4 12.8 25.9 22 Parcels No. 2. 3. 4. 5. 6 and 7 2 1.5 144 113.4 8.4 18.3 50 ?~ EnGEN Corporetion ' , ' , , ' ' 1 ' ' i 1 1 1 1 1 1 1 1 . DRAWINGS (Rough Grading Report Site Plan) Westaide City I Associates, LlC Project No. T1075-C EnGEN Corporstion ~~