Loading...
HomeMy WebLinkAboutTract Map 3552 Lot 28 Septic System Feasibility Study . r � ' • A �N,C��� ✓���'/��;� ���=�� e �It�n� En in�ers � Associ�ntes , M g g -� civil engineer5 • planner5 • 5tructural • 5urveyor5 � 5oi15 . ' SEPTIC SYSTEM FEASABILITY STUDY Purpose: To determine the feasibility of utilizing a leach line sewage disposal system for a single family lot that will conform with all the code requirements of the Riverside County Environmental Health Department. Legal Descrintion: Lot 28, P.M. 3552 A.P.N. 922-160-012-5 + - Location: Vallejo Ave Temcula, CA 92590 Owner%Applicant: Michael Ha�C.yes Heartwood Construction Cell (909) 732-� REPORT #: SS O4-250 - Dated: 10/7/04 Q PpFESSIp,�, o p M. Bq � �2 y o N . 611 m r� Exp:6 / * * s �'q�, CIV11. ���" F OF CAl1F� 28441 Rancho California Rd., 5uite. M• Temecula, CA 92590 f'hone: (951) 699-4624 • Fax: (951) 695-5084 • E-mail: mega@ez2.net . �, � • � SS O4-250 - Dated: 10/7/04 Page 1 SOIL DESCRIPTION CHART Hole # Depth (in ) Soil Description 1 S4 Tan-brown coarse to fine sand and silt; 2 64 soils are.moist and loosely compact. 3 66 ° 4 60 15' Deep Excavation The 15-foot excavation was excavated using a rubber-tired backhoe equipped with a 24-inch wide bucket. The existing soil profile description is based on Three Soil Characteristics: 1/ the soil type and grain size, 2/ difficulty of drilling, and 3/ the soil moisture content. SOIL CHARACTERISTICS LEGEND DESCRIPTION 1/ Soil Types (grain si�e) V.C.S. Very Coarse Sand- >l/8 in. C.S. Coarse Sand- 1/8-1/16 in. F.S. Fine Sand- <1/16 in. 2/ Soil Compaction L.C. Loosely compact M.C. Moderately compact T.C. Tightly compact 3/ Soil Moisture Content Dry (D) <2% Moisture Moist (M) 2% - 5% Moisture , Wet (V� >5% Moisture Q PpF ESS/p �� J �p M. Bq � Q � z � `T f1o.36117 r m a Exp: E/30/06 � ��` � �,-5 `. . ��P ( �Vit F � ,, �' � r,. � 1 ;�0 . Art Bananal, .C. . �. y � • • SS O4-250 - Dated: 10/7/04 Page 2 SOIL DESCRIPTION CHART (Continued) 15-Foot Soil Profile: Soil Type Difficultv of Ezcavation Moisture 0 feet � � �"S' - f � C 5 feet � �s-�..5 L. C 10 feet GS �`I G � 15 feet PERCOLATION TEST METHOD Twelve 30-minute percolation test readings were recorded for 6 hours after the test holes were pre-soaked for a minimum of 24 hours. The 8-inch in diameter test holes were first filled with 2 inches of gravel and approximately 10 inches of water and refilled to 10 inches after each 30-minute reading. The slowest 30-minute percolation test reading in all four holes was used to calculate the Design Rate. SUMMARY OF PERCOLATION TEST DATA SHEET Hole No. Hole Depth Time Interval Smallest Drop (in.) DESIGN Square Feet/ (in.) (min.) for 12 Readin�s RATE 100 �als./day 1 54 30 2.00 15 min./in. 35 2 64 30 3.00 10 min./in. 25 3 66 30 3.00 10 min./in. 25 4 60 30 2.25 1 35 Q �,pFESS/p N � ,��� FO M. Bq � �c, J '9 �� '� y G� i `r 17 '7 m ' . , , Banana R.C. . `" � � Exp:6/30/06 � � � \ �s>� T CIV1� ��a� � F OF CAi-�F� �_ =� -- • • � SS O4-250 - Dated: 10/7/04 Page 3 = SEPTIC SYSTEM DESIGN CHART (use 35 square feet/100ga1./day) No. of Septic Square Feet - Lineal Number of Bedrooms Tank (gals ) Bottom Trench Feet 3-Foot Trenches 1 or 2 750 263 88 1 3 1000 350 59 2 4 1200 420 70 2 5 or 6 1500 525 88 2 5 or 6 2000 700 78 3 5 or 6 2250 788 88 3 *Note: The septic tank size is determined by the number of bedrooms and the number of plumbing fixture units. LEACH LINE CONSTRUCTION A standard leach line installation depth is recommended to be between 26-36 inches. The 4-inch leach lines must have a minimum of 2 inches of 3/4-inch crushed rock on top of the pipe, and 12 inches of rock below the pipe. The native soils covering the leach lines should be maintained in an uncompacted state to allow evapotranspiration to take place. These loose soils covering the leach line area should be slightly domed so that settlement, dishing and subsequent inundation do not occur. In general, the leach field area should be kept free of all people, activity, vehicles and livestock traffic to insure the soils remain loose and well aerated. The use of "INFILTRATOR" iype leach line requires no crushed rock and 20% less lineal footage of leach line. �FESS/p � M. Bq /,��'1��" " y� � ��. , � �i:•; ` i:�.36117 r"m �� ' f�::;;:6/30/06 . � � * Art Banan R.C. . � civi� ��' � , ' ��UF CAUF��� i `,! �,, � � SS O4-250 - Dated: 10/7/04 Page 4 CONCLUSIONS AND RECOMMENDATIONS A leach line depth of 36 inches is recommended for this specific septic system design. Based on the data presented in the report and using the recommendations set forth, it is the judgment of this engineer that there is sufficient area on the lot in question to support an individual sewage disposal system that will meet the current codes and standards of the Health Department. Based on the data presented in this report and the testing information accumulated, it is the judgment of the engineer that the groundwater table will not encroach within the current allowable limit set forth by county and state requirements. 1/ .Date of PERCOLATION TESTING � I S�O ¢. 2/ Date of SITE INSPECTION by engineer J o�S�o q�. � t MEGALAND ENGiNEERS & ASSOCIATES Q PpFESS/p�,� ,(i � �� p h�. Qq�,��l ��Q�, r S , F 2 Art Bananal, .C.E. � Q � �' c� � tdo. 3ot t7 r' m � Exp; 6/30/O6 � � � ` CiVi� �� 9rF OF CALIFOF '� `' ,,' t • FIELD PERCOLATION TESTING RESULTS Date of Testing �- �s"�` HOLE 1 Rd TIME INCHES REFILL . HOLE 2 Rd TIME INCHES REFILL DROP DROP DEPTH 1 � 2. r� DEPTH 1 �� �`�v �. � �� ,, 2 7 1 � � 2 . S � 3 2 1 3 3 4 Z, 2 I P`� 4 .� _ Z S �° DESIGN 5 , 2 DESIGN 5 3 Z TE 6 7. '; �' ` RATE 6 . 0 �5�; , � � � . v o � �'. , 7 .� � . 8 Z r l P� 8 ,�i-( �C� P FEET 9 �. FEET 9 3- � REQ'D 10 �%P� REQ'D 10 � E? `� f r} Z 11 . C�d 2 S'� Z 11 .�_ �2 2 c�� �2 3� c�� � HOLE 3 Rd TIME INCHES REFILL HOLE 4 Rd TIME iNCHES REFILL DROP DROP DEPTH 1 ��� ��'� DEPTH 1 J� �.�� ~ 2 ,��� 1 PS �� �� 2 7.`�' C7 lc�—' � 3 �.7� 3 .`'`' t� 4 _ U v 1�° 4 ... �.� � C: DESIGN 5 2 d DESIGN 5 �. ? RATE 6 �_vo t� RATE 6 Z. 2 �° � 1�, <<,, ,c � � �� �� �;� � ; 2: Z� $ -- v � P� 8 7. 2 +� c FEET 9 . � v FEET 9 ' Z 2 REQ'D 10 3 C�b � REQ'D 10 _j� 2 Z � P Z� -'� 11 �jv Z �� 11 1 2 ,2 3-v� � Z5 ,�,o � t.1. Uq�,�ql�, �,Q' v` � �9 � � � y �� �� �' � ", 6117 � m � Art I3an nal, R.C.E. � [xp: 6l30/06 � ��` * �sl9T CIVI� F ,�` P `�OF CAI.�F� I I�"IiC�'�t,�4�/ • � o �: - .._.,. � :, M r � � • -� � L�t�E'�D - — ; ,o �,� %e s �`�m,�e ,t/ o ��'��xcavdf�oe� �;. � � � 0 • a �r� � '� °�� . � �ti� � � � ��� o •� .- _ :,� W �,� � � 0�► Q PpFESS/p�, S � � J �p M. Bq��l� � y R y � u / F' 3 117 m E��3 0 � ' �� � ��'� t `! ;T �CiViL oF �� P �O '�� �F CAL\F y � - �� _ ,� o� � s,� ��� �� �°� �'��o � o� , ,