HomeMy WebLinkAboutHydrology(Jan.20,1989) S
MARGARITA VILLAGE RETIREMENT VILLAGE
HYDROLOGIC ANALYSIS ULTIMATE DEVELOPMENT
COUNTY OF RIVERSIDE_,�CAL�FORNIA
TRACT NUMBERS 2 3 3 71 ��'37 2-,.=;;AND 2 3 3 7 3
January 20, 1989
J#10583P
m��.---�- L�
, •„� ��c���a� ` �
Q�pr Ea,,lp� , , I
��o • �F� MAY U n 19g7 '
' �,
�' ' Z O` : r �*�
s:? N�J. 3Z833 z;� g
• o �:
; .
sl .�� CIY1�. .� Q
.�. ,. ,1�
9lF �f �A�-�����
c ---- ! ...._..._.... .�
� � � '�
i �^
Dennis C. Bowlin M�S.�
RCE 32838�; EXP. 6/90
RICK ENGINEERING COMPANY
WATER RESOURCES DIVISION
5620 FRIARS ROAD
SAN DIEGO, CA 921�10
(619) 291-0707
TABLE OF CONTENTS
PAGE
INTRODUCTION 1
PURPOSE
LOCATION
DRAINAGE BASIN DESCRIPTION 2
SUBDIVISION RUNOFF CONTROL 3
DESIGN CALCULATIONS 4
INTRODUCTION
RATIONAL METHOD CALCULATIONS
SYNTHETIC UNIT HYDROGRAPH METHOD
OFF-SITE ANALYSIS
ON-SITE ANALYSIS
CONCLUSIONS 10
REFERENCES 11
FIGURES
1. Location Map (follows page 1).
2. Offsite Basin Map (follows page 5).
APPENDICES
l. Rational Method Calculations - Offsite Areas.
2. Rational Method Calculations - Onsite Areas.
3. Synthetic Unit Hydrograph Method Calculations.
MAPS (Map Pockets)
1. Rational Method Hydrologic Arialysis Ultimate Development Land
Use.
2. Rational Method Hydrologic Analysis Ultimate Development
Design Discharges.
3. Offsite Sub-Basin Map
INTRODUCTION
PURPOSE
This report represents a hydrologic analysis report for ultimate
development of the Margarita Village Retirement Village
(Tentative Tracts 23371, 23372, and 23373) in the County of
Riverside, California. The report was engineered following
guidelines and regulations within the Riverside County Flood
Control and Water Conservation District's (RCFC&WCD) "Hydrology
Manual" (1978).
The report addresses the conveyance of post-development flood
peaks originating within the subdivision. The report also
discusses accommodation of flood peaks originating offsite of the
Margarita Village project site through the site. Hydrologic
design calculations are provided for the storm water conveyance
network within the subdivision. Final design of these drainage
improvements will be analyzed in the final drainage reports for
the individual filings, which will be submitted with the final
construction drawings of the subdivisions.
LOCATION �
Margarita Village Retirement Village is a 473-acre, 2000-unit
mixed use residential and golf course development located within
Township 7 South, Range 2 West in the Rancho California area of
the County of Riverside (Figure 1). The project is bordered by
Rancho California Road on the south, Margarita Road on the west,
and La Serena Way on the north. Future Kaiser Parkway is
proposed on the east border of the project site.
1
Hemet -
74
n
I�
. _� ��� Lake ... ..
74 ��, L2ke� Sk
Lak� 15 . N.TS.
Efsinore � 79 ,Z"t'� .'. :;. ��'� Fi�it
� .
�
�
:�:: �
�c
a
t
�o
n
T e
mec
-
.. �::
�
�
�
::: �
� <::::;: :::;«:<:;>:� �� ... ,
}�>;>���
R
a
n
c
h
O
..�.:�.::: ::>: � .< .... . ...
California ��:-- .. . - 79 -- �'" '� �.
. _.
._� san d�ego c,a
15 �
RICK ENGINEERING COMP�ANY FIC�URE 1
CIV�L ENGINEERS: pLANNING CONSULTANTS: SURVE70RS
5920 FRIAqS HOAD SAN DIEQO. CALIFOANIA 921f0 (619) 291�0707 �
7088 GIO GICO ORIVE CML58AD, GALIFORNIA 9YOOE (E19) 7=9'�08� LOCATION MAP �
785 S. RANCHO SANTA FE RD. $AN NARCOS. CA 9208Y (619) 111V800
DRAINAGE BASIN DESCRIPTION
Margarita Village Retirement Village is located within two
tributary watersheds to Murrieta Creek. Existing runoff is
conveyed mostly within natural channels.
The southerly portion of the site drains into the Long Canyon
channel which traverses the southerly portion of the project.
The Long Canyon channel design through the Retirement Village is
not addressed in this study. The hydrologic analysis of the
watershed for the channel design is shown in "Hydrologic Analysis
and Hydraulic Analysis for Interim Condition (Phase One Grading)
for Margarita Village Tracts 23371,2,3" prepared by Rick
Engineering Company (October 7, 1988). The HEC-2 hydraulic design
for the channel is shown in the hydrologic and hydraulic design
report prepared for the Phase Two grading of Margarita Village
being submitted by Rick Engineering Company concurrently with
this report.
The Long Canyon watershed is approximately 1,210 acres in size at
the east site boundary. The channel flow enters the site in a
natural channel at the location of a culvert under Rancho
California Road (Map 1).
The Long Canyon flow is conveyed through the site in a grass
vegetated open channel drainageway through the golf course.
Three culvert crossings for onsite roadways are proposed within
the Retirement Village. Runoff from the residential areas of the
site will drain into the drainageway through several storm
drains. Runoff from the golf course will typically drain
directly into the channel. Two storm drains under Rancho
California Road originating from offsite areas south of the site
also drain into the channel. The watershed is approximately
1,690 acres in size at the west project boundary. The channel
runoff is collected at the west project limit in an existing
triple 5-foot by 12-foot Reinforced Concrete Box (RCB) Culvert
under Margarita Road.
The northerly portion of the site drains into a natural channel
which traverses the site on the south side of La Serena Way. The
northerly watershed in approximately 390 acres in size at the
east site boundary. The watershed flow enters the site at the
location of a future storm drain under Kaiser Parkway.
The northerly watershed flow is conveyed through the site in a
storm drain system under the streets in the Retirement Village.
Offsite areas east of Kaiser Parkway and north of La Serena Way
enter the storm drain through existing and proposed pipe systems.
The northerly watershed is approximately 620 acres in size at the
westerly project boundary. The Retirement Village storm drain
connects to an existing 102-inch Reinforced Concrete Pipe (RCP)
installed for development of Tract 20881.
2
SUBDIVISION RUNOFF CONTROL
Minor and major storm runoff within the Margarita Village
Retirement Village is controlled with storm drains, streets and
open channels. The RCFC&WCD Hydrology Manual requires that the
minor (10-year) storm runoff shall be contained within the street
curbs without overtopping and the major (100-year) storm runoff
shall be contained within the street right-of-way limits.
Interior streets within the Retirement Village are classified as
private streets with the right-of-way line placed at the back of
curb line. The interior streets have right-of-way widths of
either 41.5 feet, 45.5 feet, or 49.5 feet. The interior streets
within the Retirement Village have either 6-inch high modified
type "C" Rolled Curb and Gutter (See detail on Map 1) or 6-inch
Type A-6 Curb (County of Riverside Standard No. 200). The
collector streets within the Retirement Village also have the
right-of-way line placed at the back of curb line. The collector
streets have right-of-way widths of either 53.5 feet, 65.5 feet
or 71.5 feet. The collector streets have 6-inch Type A-6 Curb.
Streets are used to convey runoff away from individual homes.
The depth of water will not exceed 6 inches in the interior and
collector streets during the 100-year storm event. This will
contain the major storm runoff within the street right-of-way.
Storm drain systems are used to convey flow within the
subdivision when the flow depth reaches top of curb in the
100-year storm event. The dwelling pad elevations will be
established to provide one foot of freeboard above the top of
curb elevation at the street adjacent to each lot.
Runoff within the golf course is controlled with grass vegetated
swales and channels. The minor swales will be placed to collect
localized runoff from the golf course in order to protect the
adjacent homes from inundation, and to protect the golf course
greens and tees. The channels will convey runoff originating
offsite downstream. The channels will also be designed to
protect adjacent homes from inundation and protect the golf
course greens and tees.
The swales and channels will be designed for non-erosive
velocities. The dwelling pad elevations adjacent to the channels
and swales will be selected to provide one foot of freeboard
above the 100-year water surface.
3
DESIGN CALCULATIONS
INTRODUCTION
The hydrologic calculations used for design of the Margarita
Village Retirement Village storm water conveyance system are
presented in Appendices l, 2, and 3. The drainage sub-basins
used in the hydrologic analysis are shown on Map 1(map pocket).
The layout and routing of the storm drain systems are shown on
Map 2. Offsite sub-basins are shown on Map 3.
The RCFC&WCD Hydrology Manual Synthetic Unit-Hydrograph Analysis
was used for analysis of the watersheds in excess of 300 acres in
size. The Rational Method was used for hydrologic design for
drainage facilities with a tributary area of less than 300 acres.
The conveyance of flood peaks originating on the Retirement
Village and accommodation of flows originating offsite through
the site are discussed in this section. The design flows
provided are based upon preliminary grading of the site. Final
hydrologic and hydraulic calculations will be provided with the
Final Drainage Report and construction drawings for the
individual filings within the Retirement Village.
RATIONAL METHOD CALCULATIONS
Rational Method calculations performed for this report are shown
in Appendices 1 and 2. The 100-year design storm is used in the
design flow calculations for the storm water conveyance system.
Soil characteristics were identified using the Soil Conservation
Services Soil Survey for Western Riverside Area and Plate C-1.53
from the RCFC&WCD Hydrology Manual. Rainfall information was
obtained from Plate D4.1 (Murrieta, Temecula and Rancho
California Area) for the site.
The Rational Method runoff coefficients used assume developed
conditions from the Margarita Village Tentative Map for Tract
Numbers 23371, 23372, and 23373. The density of the single
family areas of the Retirement Village is greater than 1/4-acre
lots. Because of the higher density, the single family areas are
modeled using the Condominium Runoff Coefficient Curves from
Plates D5.1 - D5.4. The multiple family unit areas are modeled
using the Apartment Runoff Coefficient Curves. The golf course
area is modeled as Urban Cover-Turf from Plate D5.5. The Runoff
Index obtained from Plate D5.5 is used in Table D5.7 to determine
the Runoff Coefficient. The RCFC&WCD recommended using 5 percent
impervious cover for the golf course.
The Rational Method calculations for the 100-year storm were
performed using a Rational Method program. This program is a
computer aided design program where the user develops a node-link �
model of the watershed. The program can estimate the conduit and
channel sizes needed to accommodate the design storm discharge.
4
The node-link model is developed by creating independent
node-link models of each interior sub-basin and linking these
sub-models together at confluence points. The program allows up
to five streams to be confluenced at each node.
The program has the capability to perform calculations for nine
hydrologic processes. These processes are assigned code numbers
which appear in the printed results. The code numbers and their
significance are as follows:
CODE l: Confluence analysis at a node
CODE 2: Initial sub-area analysis
CODE 3: Pipe flow travel time (computer estimated pipe size)
CODE 4: Pipe flow travel time (user specified pipe size)
CODE 5: Trapezoidal channel travel time
CODE 6: Street flow analysis through a sub-area
CODE 7: User specified information at a node
CODE 8: Addition of sub-area runoff to main line
CODE 9: "V" gutter flow analysis through a sub-area
SYNTHETIC UNIT HYDROGRAPH METHOD
Synthetic Unit Hydrograph calculations performed for this report
are shown in Appendix 3. The 100-year, 3-hour design storm is
used in the design calculations to predict the flood peaks in the
storm water conveyance system. The precipitation value used was
2.27-inches which was taken from Plate E-5.2 from the RCFC&WCD
Hydrology Manual. Soil characteristics were identified using the
Soil Conservation Services Soil Survey for Western Riverside Area
and Plate C-1.53. The Antecedent Moisture Condition of Two was
used as recommended by the RCFC&WCD. The watershed boundaries
for the hydrologic analysis were identified using the RCFC&WCD
200 scale orthophoto mapping for the area. The watershed
boundaries are shown at 2000 scale on Figure 2.
The Synthetic Unit Hydrograph method is used to si2e the storm
drain which intercepts the offsite area of the northerly
watershed. This watershed is to be intercepted by a storm drain
which begins at Kaiser Parkway. The offsite watershed is modeled
for developed land use in the offsite watershed assuming 1/4-acre
lot single family development for the entire area west of
Butterfield Stage Road and 1-acre lot single family development
east of Butterfield Stage. This discharge was compared to the
100-year discharge assuming existing land use with a 25 percent
bulking factor for debris loading applied as specified by the
RCFC&WCD for this watershed (Appendix 3). The 100-year developed
discharge is greater and governs the analysis.
The trunk storm drain which conveys the offsite discharge through
the site also intercepts discharge from the Retirement Village
along its course. This storm drain is located in street "00" for
approximately 1300 feet and then is located in La Serena Way for
its remaining downstream portion. This storm drain is designed
for the 100-year developed flood peak. The storm drain will
connect to the existing 102-inch RCP storm drain south of La
Serena Way. The northerly watershed is divided at two points in
5
. .. �a, ) �.- ` � � � I I _. �{ . O C.' � �\'���\ \.a•` \ � i 'f . 7�t/ 't. ,(i 1 S ` � � - � /
� `� � � i'� � `� \ l / C� ��L�� . ,� �V i /1 \ ��1), � ) J , /�� � ^ i� 1 U\U/� y �c- ��� (( �
� � �� � c" � i � �P /,Y"" • �`_-' ( i �1 ni� �.r��0' ��� �
� �� , I ��x Ol/ I ,.� ` �\ j s \.,)- �' ����i' � � -''7� � - i �" � ' ��-� .:i}., � :' ,. �4�3=U-�� i 1��; �' i !'.l 1?I\�
� r.l �-�- � � , �� � � �� ( � �1 �:�,�,tL h� _ > ) ( � � ( � � � ,� r �:%'� < <i - -- ==�r ��=.:� 1 ( ((?L:-�<<
- - •� � ��. I `.1 I .ii�'� � )1 � l �J� i /. � ` � �r�� , �/_. �J t 't ��t .��-'•" t '.C� � � - �� ��. �1 � � � � � �. ) � ;� , ��
_. - :'.i'� �, �j u ` �!i I . C', - ,.1 15., , •e.� t�� : �''�.i : J � , �, . \j+1; ` � ( `,_ � .`; S �
� � p r )�� , � 7 f - ��i .� ; •- � t ,, � l � • �� r:- �s t � , `I' -�.� L�1 I � �, • ��} �.
��� O �'jl �� �� � ��. i�/�., '�� , � )I (�� � � / /: . \ � ' _ � � �! � /. J i ) n• t, ,��j f ���`�Fl j `` -� ! �/\'� 1`�Jl� I �1�/ ) I�}(/��r' �!J
:a:� � r`:. (` .L'" l i � .�L_ . �� / � , r i / C ,\ i ? i -_ _ r• "� ' �'`��' •,�1' ty� �Y I \ 1 1 � c J _ _/ / (1��j \ �� �
� J , \ , --�,-;, f � ;�. � �. ; ,, ;� _ ; ,�_t � �.> �-�� � Z� ...�t , _ z�.�. `��,.�;�?��=� ,-;� �� 1 �; ����?%_=� ,, �.r `1 :
) 4��..��� � --;��� �'�• ���- .����� (� �l f � • ./' �,�� j ;�)�� � � ��;���ti� ,��� ����. -j � � �� ��/���Zl �c�. `''��_' � Z
�� 1 �,.
. ?i �1);>� I ; '( r' t ,, s � � �� ��.�, , , ,� ,, ,� �t . rrr . �� ���,, � � 1 �<<� _�� `�`�,,,
:..�,�: ��. ��a�,�,�;�r; " , �'' ;� <<<,� ;' � ���p ; � l; � � `� '�_J �� �..� ��� ��� �•�-'':.��;; :.� �- �, � ����; � y C% � �� �� �1���� � C �
� 1 s /, ,� c �i /1 � - �1�. I �� '/.� \ �-•>� , Q f � ,r,�� �� � �� � �'�, r �; f a
, , I ,' t; ,�.-. ,� �� o , ,, V�
, ��,,,. 1. � � - -� ��r:.rv1 �� �l , ,� - � _�c � ol. , �, . �l �. ���. - `', \o � �, � ,l, � 1 ��
��,n l�� � � ��'� > I� r. �� l� - J.� n `� r �\,�.� �� I l �� `� _-�? �'., a ��'•'�� \� �.1' '����' \�� � �"-'� 17 �)\, � �J � �`�/rt�
�1�+'1 •' --' � .` � ` �;..' � ' S �I 1 � C.•i- ,, ; , � ��;1 !I: � �l 1� �,V � ( �r. �� : ��r. � �--- L 1- � / � 1. �., � , _ _ �
�� �, � �� � �� ,, �_� �� o '� � �f.� � � ,,,� _.1� ' � \ �''' 'L;� `� ��`� _ � ��', m
� , s l � rl � � Q
�� 8' �r: � �C _ '1 ` ! C �`� � 1
� :� J � � .� ��.� .�•� �) r ! i �� :0 1}� ' \�t � � ;T' � �• �;% M �. c,..3 j �),.�`\� �� •_C \� �/��>>
--r ,. < <�- lI) ° I , � �-� ` �� N
.� , ,.` > .�� �� � J � � �� 1�.,�� �.�,�::���� �. �� ;�,� �.. �_
�����,..; -.. :`,. � �\,1,� �`� 1 Il� t� I� �� ��j • � �I��� I \ V� ` S � i• �J (� � � ��� � ;'C��� � `�\\ \� �1`��`�
!�: R .r.` .. - c � `! �\ C` , � � 1 �' �I., �/ ,� L, � 1 � � l.l "�) � � --- O ° �
. ! � � ,. ' 1 -- �� r J� � )) ? � z. � r � � �a� l �. � `I� , , ,; �_ < v � • jfi�>, �� � ::; ' ::�.� , � � �=-•� � -J 1 � W
'� "•,`� � i ,\ ? _!� �-- I i ; t II \� / � � 11 I ; J J 1'v � . 1 � � � t' ` , t t ' ! ��-� ` ' o
"l. ; � � � ),�� � / I ( 1` � � ) ?� \� � � ,� �y�� .1----� , c � , ./ �
\�\ ,u'�� � . `.��. ) ,'1 ) //;: . � � �,l � ���� i ' �/ � �� : � l�A�1�� ��.� � ' -' �;�-� 2 ����. � ��� � � ' �j� t: � � � ���_ r� � � � � � �
?�:�� ��,; � -�'/ ((�IQ' �� � ��'�,,�� �.��� �� '�i � �.1��1����- � � � � � ( �`��,��>.; � � c--� �� 1(, �).�� ��
,� � ��� l >> ;� � � � . �' .� ,� , � . -�, � , ; � , -��� 11 , � V�
�� ,A �; , ,� ���� , o . ��� �� ;��:,;���� ;, ,�, � 1 �,�;:- �; ��,� � �;� =� ��� �,� <<ti� z�� _ �
�� - ` .1 � ''� ��� � , _ E ° :,� � l : � 1 � �
�~�� E'� . �`. , ti` �i���I . � i%Ci^ n) � � t ,} l�-i �m �L\ � I�� � �i �,_ll �,L ���-�
`�1• ' .. )�- �
�� � . 1 ��j , � { �� ^)
�•� �,;� �/ 3 � - 1 \• � ( �((' / �! ��' i �1� � � { � 1 >: � . r ? S � � ` ��5 �, �/�) .\ `' �.� � • �� N \ . \`�� \\ 1 � r � • • J � ,. '�\. j/' �1 C _� �.
, ,�. t. � \ ��; �, ( � ,��� . � 1 � ( , 8� � , -� 1,� �„`. . 5 \ ,l � � �� � , _ , _ _� . , � 1.�.
s ��,,.{ 1 ` 1r' �t /�o // e ) i S : °� l �r l I I �''_ i i �� �� �%i � � i "(�,S�i 1 ! ` � " ,\ � �:�,. �:. ,.�i ��' I �- `�-
, `:\ ���; i �. �, �� _, � r ij i �, ,1 E: � �; 'S <;. ( r '� � �, .- J l' � _ 9 � ��tJ� J� O
� � � , � � i � ; � i ` � 1 � � \ �� �`� � � . . � )�� , � � -�,�; � t
�� � E� � ��\ � l�, , � -� )"l;i � �; l !: 1 ��� j� `', .'.; :.,� _✓, ;'��? ` '� I ��,���_, --'� � .:�
�� ��� �� �� � I � L' � ��'��� ' � � °� �?��-�- J� / ��� 1 \ �c c,P . , � . �� �.,
�.(i o� ` � � �, (�r �i � ( j. ��� � 1� � l io�� � � � ;A.�� 1j �� � ✓ _� �<< / tL'=�'��' �i � �� �� I p �„ �� � �
;1.. p � i .,1 \ • ,�� \��.� >5:�. \1 � ' I �'o \ i� 1� r � - �\ J � �'>��� � ' \ ? l ' ��1�� �� . r ll; �\ ) p o ° e
' � _ ! � // m I � .� '�..\~ l / � � ) � �.. ��/ � �L. r•.i' '� � � � � 4 d :
� \. i c � � \S'
�� )'��� � ��o)) �� � � Q• � �� ��� � k,�.''�� �(��� .� �� ��l � (�• �� � ���.� ���::'�� ,) � a n � ^
�.) :. � � � ,, t. ��, `� ,,. , � � � � ���\ �� 1 '_ `:\, Q� q
�1 � ' I °i �:; � ( ' � i � � � . 1 i A� � � , �' � i ; � A'_ '_ � �� , � �-� )� ��� � � � � � _ •� 1:, -' i . �,, a. ^ °, ;°.
3 �1r` ! ,�i� `I ' I I� � �� ) I (��i'?'S�\ �\�\ � �( � � �� - L \ lo� � ( � :J I ,��'`' �) 1 �\ � ' 3� 4 �, \ oI 2i � \ � � a ° g
� ��f� , /� d� -� % � o � _ _�� i �F�, , � �t.. ��� �-� _ ,}y� > >, � ;r:, n '„� . G � � � t-\��, c-��-J V � - g a
i " I ,�.F � �z°. :f � ���'1 ;_:� !� �\ ,� ti '. t� 1�D� " , <<_ � � u p . ,- 1'�'Q. � � � ---- �.a ° �
� �;' If '• _. %��; _- "/���� 1 S � N ;':�•�. '�; '} �`; ,��� ��o � � �%;.j � � `J 1 � 1 . I � ' , �' . � = Q y
,��:. _ , �� � < G; : 1 r �` r ;A ' / ) -� n .:. o � � „ S f �=,J_1 .f I �� �� G, o L � rri J � � � � a o °
., ,
' ,,� ( f / j 1 ��� ;,,� �!� ( , � ( ( � S � .. V 1 l ��l �,, • � I [ ��') �l / � `) ���(� --` J� `1 \ � �.,-- \ `v F ^'( f ` ( p LL p j ¢
1\ �' � l l , r ) r � \ •� 1 ) � � I \ J l) � Z
\,i ��� , I ��,l� .�o \ .I�) l � -� j �, . ���. I'; . i � r�, ���� /�'��� �`L- l�_ L / V 7 t�.i =
�� ', . �;� l�.` �� � ' ._ l �`/�;�,;,. �. ;� , ,� ,�A,1� ` � .\/%. � ( ( 1 ( r ,1 ���c�,..� �.'' �\ ��' j�'�,v) i "�J�� �(9U z
, ,.- , o ; , ,� , � j �, ��,� . ���� ),'� � L �1�� ��{`�, �� WZ <�
� (� � ��/ -" W = ° m
z G^ ,. i
\ � � \ • / J a�� Z ` � I \ ) �l'- ./l �` O J
, `�` . —� . � , r �- , � S ' � % �. �' �, • � � , � , �. �4� � �_ ° � r �-? � " a
�, � ��
i � . ° �1 I /� � :.� ; �l: J ��a, � . Tj ' I: f ��� ��i4 i � � / �� � 'J� � �r"� �.� � � t C � �� - f �� • .f`. p z c�i LL
� .
; .. �� (� . , ' ) <
: �. n � � � � � f ��� �.) � y' � .1� - � ���. �, - �. "� :� . � ., .-�- w
h�J! )' 1��.T 3 ("� � ? � •�i; � -�'��r..��� �)1- ;��� . �l/ ,, 'l �� �
'� " �. �� ��� , � ¢ ���. .�/�� �1. � < ��� � - � � - �� ��� �� , �� ��l � _ .� �� � � � .�� Z��\ �.� ��'.> l �� � ��� x � < � �
I � � � \\ il.� � � � � i� .. _ /� j (.i ) ..� I (�.` !`'. �..� �I (�� ' � . O �►Tl l� � '�� (- > C �1;�.1�Y� � _�� `� W = N u �
Ol � ��.�, l� /r�' �� ` S , . ��.� /':� ��;. ���� ' c•��'= ?< < 1 � 1 � \, .� 1 �� � j ? � , �� ``� � ¢°U
' �_ � °_ _ - _- , ,-- . � � �. ; � ' ( > ' � � �� y ���' ' �r� 'S� ` ' �� _ ' . � � � "� '• c ; _� �L W <_ o i
___-__��-^__ = ° ci = _ ; � __ � .ro i ( , +' i "'.�'�il /1 ! �� i � ( ��� 1 il � C �1'" , �� j 1' �r��. ��� � �.il •'-� • �' J V d '�'' ° a
\ _ � `� / o _ � o --- _� 1 '� � � I ��, ro� �;�; :,1 0���1 li( I 1 - . � �n �_, � r• - 1�. (j '• f � � � l ] , � ^ �. �•1 _�i, 1 � - � � m c m
�> q ( \ 4 '� � <�_�� ��� '@) I4/�f�_=2..,y� # c, _ � I =zc� � � 1 � _i� 1<,� � ) �� _ 1 'd6 �� S� �-- U �
\ , I� - �\o f ) ,� .��. 1� `1 (1�I�C�3 O �_ 1 "�I �� � _ 1 = ��- � � - ?_L`� �, ---- ( ' j � � -� -.)��--
m �� i � ! t���I ^. l .. ji C� �• l �%� "'l� _...�.-� �'/ 1 �� i� �� -�1 (`' �- -=�a. j �\,. N-P � 1 ��, > �� • �
Y' : r ��, . " 7� / li I � �•1 / i . , <�.... �'� .�1� ,�� � � � Z -\ , `�ryll; 7 � � ` �\�`� � ,/�� �
� 1 �' r �,� � ;�� � �
,--� 1 � ` �1� \ " � ) � i ,� ; _,,> , > '� ro _ s r ,� ��., .. ,. � i � ��' l � �� �,
, . , _
�r ( � 1 1 I t I`
1 � / J I � l� l.�'1 \' ��./ ` _� I � / . �, �� , �) 1 � 1 <<—, //�h� r � c � .�1 �--�.���. ` ( ��<�-w-�o/1�� l�
— i � Y-� F � , ) � , ->-� ' f_ �� �� S` �n , d� S�� �� � -- �-l�.t v __ ? I '
; � -.. � }- �, I I r n — ) � -c- 1 . ,, „ a .� � ` , �
�� i�. �! ' _ i� - 11� �� l 4� �`I 11 (� ! � l i � '�� ��'�? �!.� � I ��� � ,� �-rl�� -- ' __ ��il i� , �
� ,�:
i /,J � il'� ��� �� � f\ \ \�.� �T 1 � � � �j� 1%1'�\��i\ '�1 I i r l � (; � � ) U �1 � Sl - "���_-�a/J ��� i 1 �-,�' �•
addition to the offsite area (Figure 2). The storm drain design
discharge is determined between the design points by prorating
the discharge entering the storm drain by the contributing area.
OFF-SITE ANALYSIS
Analysis of the remainder of the offsite sub-basin areas which
are less than 300 acres in size were analyzed using the Rational
Method program. The offsite sub-basins were identified using the
RCFC&WCD orthophoto mapping as a basis. This information was
supplemented by design plans and tentative maps prepared by other
consultants, and field observations. Inlet and catch basin
sizing is not addressed as part of this analysis. At points
where inlets or catch basins are required to meet the design
criteria, the entire flow at the node is conveyed downstream from
that point within a pipe. Inlet sizing will be completed at the
time of final design and will account for inlet bypass, if
applicable.
Runoff originating on the offsite areas are conveyed through the
Margarita Village Retirement Village within storm drains except
for the major drainageway in the golf course north of Rancho
California Road. This drainageway is designed in separate
reports mentioned previously in this report and is not addressed
in this study.
The offsite areas south of Rancho California Road are discharged
onto the Retirement Village site through two storm drains. These
pipes will be extended and discharged onto the golf course. The
westerly storm drain has inlet flows from six onsite inlets
adding to the pipe flow.
In addition to the large offsite watershed analyzed using the
Synthetic Unit Hydrograph method, there are two sub-basins east
of Kaiser Parkway which discharge onto the site (Map 3). One
offsite sub-basin is approximately 14 acres in size and will be
intercepted at the intersection of Kaiser Parkway and Street "NN" .
(System 1910). This storm drain will run south within Kaiser
Parkway and connect to the northerly watershed trunk storm drain.
The other offsite sub-basin east of Kaiser Parkway is
approximately 49 acres in size and will be intercepted at the
intersection with La Serena Way (System 1900). This storm drain
will run westerly within La Serena and connect to the trunk storm
drain at the intersection with Camino Corto. An additional
offsite sub-basin 17 acres in size from the school site north of
La Serena will add to the storm drain. The sub-basin runoff will
be intercepted with the existing catch basin and 18-inch CMP, and
additional street inlets. These inlets will be connected to the
storm drain.
Three other sub-basins north of La Serena Way will be collected
by the trunk storm drain. One sub-basin is approximately 11
acres in size and consists of existing single family land use.
The runoff from this sub-basin will be intercepted with street
6
inlets and connected to the trunk storm drain. There is an
existing 5-foot inlet and an 18-inch CMP west of Camino Corto
which will intercept a portion of this sub-basin runoff and
connect to the trunk storm drain. Another sub-basin is
approximately 40 acres in size and consists of existing single
family land use. This area is serviced by seven large (10-foot
to 12-foot) inlets north of La Serena in the vicinity of Via
Puerta and has a 42-inch CMP outlet pipe. These existing inlets
are assumed to be adequate for the majority of the street flows
upstream of La Serena. The existing 42-inch CMP will connect to
the trunk storm drain. The westerly sub-basin north of La Serena
is approximately 4 acres in size and will drain directly onto the
north gutter of La Serena Way and be intercepted by street
inlets. These inlets will be connected by laterals to the trunk
storm drain.
Another significant offsite sub-basin is the area covered by the
existing trailer park north of General Kearny Road (Map 2). The
runoff within the trailer park is conveyed in the asphalt access
driveways. A small existing inlet at the intersection of General
Kearny will intercept only a minor portion of the 100-year flood
peak. The remainder of the 100-year runoff from the trailer park
will be intercepted by additional street inlets in General Kearny
at this location. The inlets will be connected to a storm drain
in General Kearny which will run west to the intersection with
Street "Z". This storm drain will intercept two other offsite
basins at this point. It will connect to the extension of the
existing 30=inch storm drain at La Serena Way and General Kearny
from a sub-basin approximately 24 acres in size from existing
Tract 20735. The collector storm drain at General Kearny and "Z"
street also intercepts runoff from an 11 acre offsite sub-basin
from the park north of General Kearny. From the intersection of
General Kearny, the storm drain is located within "Z" Street
through the Retirement Village site.
ON-SITE ANALYSIS
Analysis of the onsite sub-basin areas within the Margarita
Village Retirement Village site which are less than 300 acres in
size were analyzed using the Rational Method program. The onsite
sub-basins were identified using the preliminary grading plan for
the site prepared for the Tentative Map. The sub-basins used in
the onsite analysis are shown on Map l. Inlet and catch basin
sizing is not addressed as part of this analysis. At points
where inlets or catch basins are required to meet the design
criteria, the entire flow at the node is conveyed downstream from
that point within a pipe. Inlet sizing will be completed at the
time of final design and will account for inlet bypass, if
applicable.
Runoff originating on the Retirement Village site is conveyed
through the site within streets, storm drains channels and
swales. Storm drains used in the Retirement Village will be RCP.
The street layout and preliminary layout of the storm drains are
shown on Map 2.
7
The onsite areas in the south-central portion of the site
(systems 1000, 1100, 1600 and 1700) are each collected by a
separate storm drain system (Map 2). These storm drains collect
runoff entirely from the Retirement Village site and discharge
onto the major drainageway on the golf course. System 1000
collects runoff from 51 acres in the easterly portion of the
large single family area in the center of the site and discharges
onto the golf course channel at Street "B". System 1100 collects
runoff from 11 acres in the westerly portion of the same single
family area and discharges onto the golf course channel at Street
"E". System 1600 consists of two separate small storm drains
collecting runoff from the multiple family area in the south
portion of the site backing up to Rancho California Road. These
storm drains also discharge onto the golf course channel. The
six inlets along Street "D" connect to the storm drain from the
offsite area south of Rancho California Road. System 1700
collects runoff from a 17-acre area including the south portion
of the clubhouse building and parking lot, single family use east
of the clubhouse area, and runoff onto Streets "B" and "C".
System 1700 discharges into a box culvert on the golf course
channel downstream of Street "B".
The multiple family and commercial areas in the southeast portion
of the site (systems 1200 and 1400) are collected by storm drains
which discharge into the Long Canyon channel (Map 2). System
1200 collects runoff from 51 acres which includes the multiple
family north of Street "C" and the commercial area at the
northwest corner of Rancho California Road and Kaiser Parkway.
System 1200 discharges into Long Canyon south of Rancho
California Road. System 1400 collects runoff from a 17-acre area
from the multiple family area along Rancho California Road west
of the commercial area. System 1400 discharges into the Long
Canyon.box culvert crossing under Rancho California Road.
The central and westerly.portions of the site (system 1500) are
collected by a storm drain which discharges into the north cell
of the existing triple 5-foot by 12-foot RCB Culvert under
Margarita Road (Map 2). System 1500 collects runoff from a
227-acre watershed including some offsite areas north of General
Kearny Road and La Serena Way. The beginning of the system 1500
storm drain collects runoff from the single family and golf
course areas east and north of the clubhouse. This storm drain
connects to a storm drain across the golf course downstream of
Street "B". The runoff is conveyed through the golf course in
the storm drain along the south side of the M.W.D. right-of-way
and intercepts runoff from the north portion of the clubhouse
area, and the golf course along its path. The golf course storm
drain connects to a storm drain in Street "Z" which intercepts
runoff from the north. The storm drain in Street "Z" collects
runoff from offsite areas (see the "Off-Site Analysis" section of
this report) and from the multiple family area in the northwest
corner of the Retirement Village site. After the two systems
combine, the storm drain traverses west and south from Street "Z"
along the right-of-way line of Margarita Road. The storm drain
8
also collects runoff from the single family area in the west
portion of the site before discharging into the triple RCB
Culvert.
The northerly portion of the Retirement Village is collected by
the trunk storm drain from the offsite area east of Kaiser
Parkway. The design discharge for this trunk storm drain is
discussed in the "Synthetic Unit Hydrograph Method" section of
this report. The lateral storm drains from the north portion of
the site (systems 1300, 2000, 2021, 2028, 2035, 2200, and 2300)
connect to this trunk storm drain and are designed using the
Rational Method. System 1300 collects runoff from the northerly
portion of the multiple family area along Kaiser Parkway and the
adjacent golf course. System 1300 connects to the trunk storm
drain at Kaiser Parkway near the trunk storm drain starting
point. Systems 2000, 2021, 2028, and 2035 collect runoff from
the northeast single family portion of the site and connect to
the trunk storm drain along Street "00". Systems 2200 and 2300
collect runoff from the north central single family and multiple
family portions of the site and connect to the trunk storm drain
along its reach in La Serena Way. The trunk storm drain also
collects runoff from offsite areas as discussed in the "Off-site
Analysis" section of this report and from street inlets along La
Serena Way before connecting to the existing 102-inch storm drain
near the west boundary of the Retirement Village.
9
CONCLUSIONS
The storm water conveyance system for the Margarita Village
Retirement Village includes a storm drain network, a open channel
system and a street system. Design calculations in this report
show required systems to provide protection for the dwelling pads
within the project during the major (100-year) storm. Provisions
are made to accommodate developed runoff originating offsite
through the site.
Final hydraulic calculations for the individual filings within
Margarita Village Retirement Village following the design
presented in this study will be provided in the Final Drainage
Reports submitted with the construction drawings of the filings.
10
REFERENCES
l. Riverside County Flood Control and Water Conservation
District, 1978; Hydrology Manual.
2. Riverside County, California, 1982; County Road Improvement
Standards and Specifications.
3. Rick Engineering Company, 1988; Hydrologic Analysis and
Hydraulic Analysis for Interim Condition (�Phase One Grading) for
Margarita Village Tracts 23371,2,3.
4. County of Riverside Flood Control and Water Conservation
District Orthophoto Mapping; various dates.
5. San Diego County Regional Standards Committee, 1986; Regional
Standard Drawings.
6. Rick Engineering Company, 1988; Hydrologic Analysis and
Hydraulic Analysis for Phase Two Grading for Margarita Village
Tracts 23371,2,3.
7. Robert Bein, William Frost and Associates, 1987; On
Hydrology and Hydraulics Report, Margarita Village, Tract 20881.
8. U.S. Department of Agriculture Soil Conservation Service,
1971; Soil Survey for Western Riverside Area.
11