Loading...
HomeMy WebLinkAbout#122 Temecula Regional Center Power Center II M 0 .. o Center m la RegionalTe ecu Power Center II MASTER SIGN PROGRAM ADDENDUM MARGARITA RD. TEMECULA, CALIFORNIA CONDITIONAC'Y APPROVEDby the City of Temecula RECEIVED ,Q Administrative Approval ❑Planning G-ector ❑Piannirn ,r:c., ,.4r1n By ❑City Council on subject to lite Findings contained in Resolution No. and the Conditions of Approval Case No. Vim 0515 Date O _ W E S T E/R N S I G N 601—1— Case tanner TEMECULA REGIONAL CENTER POWER CENTER 11 MASTER SIGN PROGRAM ADDENDUM SEPTEMBER 29,2010 WALL SIGN SPECIFICATIONS MAX SIGN LENGTH = 75%OF SIGN AREA c� w x uj TENANT NAME MD J ONE LINE COPY ONLY WALL SIGNAGE SCALE 1/4'=1'-0' REVERSE-PAN HALO LETTERS 1.PERMISSION TO HAVE AND LOCATION OF WALL SIGNAGE TO BE DETERMINED SOLELY BY DEVELOPER OR LANDLORD. 2.MAXIMUM 4 SIGNS ALLOWED ON BUILDING 2"PEG-OFF nNEARr n[nRv¢m 3.MAXIMUM LETTER HEIGHT•24 INCHES FOR ONE LINE OF COPY ONLY 2 3l4' l /-E om° 4.MAXIMUM LENGTH-UP TO 75%OF ALOTTED SIGN AREA axFETu u uFw �' 5.PERMITTED FONT STYLE-FUTURA HV BT °1R"F"ns AU1CH NO LOGOS SHALL BE ALLOWED COIOUIIWR WtDAMLFW ULASS SIYO O'JIb . 6.APPROVAL OF MATERIALS,CONSTRUCTION,AND INSTALLATION METHOD IS REQUIRED FROM I0-T[10.VNgM1OR mn Wn THE CITY OF TEMECULA PRIOR TO INSTALLATION. - GA[rAERaG GTO NISU[AIE103[FM EUHOORMFR NM FABRICATION SPECIFICATIONS: „uFw 1°e;oxmW�roowE[w " '- L[uNP.l00 � 11'r SM.GfAR{POlIBD1TON. `fE1pM0Wk 1.ALUMINUM REVERSE-PAN HALO LETTERS fciWWiNW pp LM ._ 2.FINISH-PAINT LETTERS GLOSS BLACK 3.ILLUMINATION:30 MA 6500 WHITE NEON TUBING �I,I Wn1 WaoTRu« 4.3/16"CLEAR LEXAN BACKING EGN luexx TIO SGPEw'Wl rl]PIASTIL ANGH[M Af]-ALIA°RIIM LEI I[R RETURN W4L010.0J0'AILW.fACE 1.MEP 011[Op3G0 LT � �- SVAIdIXIPRUARY UL APPROVED INSTALLATION DETAIL REVERSE CHANNEL LETTER WITH REMOTE TRANSFORMER 1'=1'4' W ESTERS I GN I 4 A W N N D TEMECULA REGIONAL CENTER POWER CENTER 11 MASTER SIGN PROGRAM ADDENDUM SEPTEMBER 29,2010 E. PLACEMENT OF WALL SIGNAGE - East Elevation 104'-0" 30'-101/4' 30'-101/4° 23'-0 23'-0" EQ. EQ. EQ. EQ. I 12'NON.ALUM. ADORESS NUMBERS - fCOACRYEICIETTERS 1212 SIGN AREA SIGN AREA 2'-0"c R � I i I }, i i • `` XY Scale:1/8" =1 WESTE�'R � I G N a i A W N I N 0 (y Y TEMECULA REGIONAL CENTER POWER CENTER II MASTER SIGN PROGRAM ADDENDUM SEPTEMBER 29,20104 �v PLACEMENT OF WALL SIGNAGE - West Elevation 104'-0" I 30'-9" 30'-9 I 23'-0" 23'-0" I E0. E0, EQ. EO. 12'NON.ILLUM. ---- - ADDREESNUMBERS - .... FCO ACRYLIC LETTERS 1212 SIGN AREA SIGN AREA 2'-0" Fii I I Scale:1/8" =1' /• ' � 4 WE8TE/QR S IGN 6 A W N I N D TEMECULA REGIONAL CENTER POWER CENTER 11 MASTER SIGN PROGRAM ADDENDUM SEPTEMBER 29,2010 NO WALL SIGN ALLOWED - North Elevation 88'-0 34'-9" - - - 12 NON.ILLUM. - -- - AUORESS NUMBERS. •'-`�•'a^"""' FCO ACPVLIC LCTTFRc\ 1212 I 2�4' l , I Sn Scale 1/8"= 1' WEST-/RN S IGN A A W N I N r TEMECULA REGIONAL CENTER POWER CENTER 11 MASTER SIGN PROGRAM ADDENDUM SEPTEMBER 29,2010 NO WALL SIGN ALLOWED - South Elevation I 88'-0" - I 34'-9" I i 17'NON UN ACD�iFSS NAP[N; hlU FI;NYLII LtIIFHS _ �� N, 12 21.0■ `4 i I i I I � L ' I i I I I ii i I Scale:1/8"=1' WESTER5IGN 6 A TEMECULA REGIONAL CENTER POWER CENTER 11 MASTER SIGN PROGRAM ADDENDUM SEPTEMBER 29,2010 NEW HALO LETTERS AND PUSH THROUGH CANS MOUNTED ON A CMU WALL SCALE:1/2"=1'-0" 12'-9 1/8' MANUFACTURE AND INSTALL(1)SET OF HALO LETTERS AND(4)PUSH THROUGH CANS 6'-4 3i4" 6'-4 3-4'' MEDICAL CENTER:HALO LETTERS BACKS:3/16"CLEAR LEXAN BACKS RETURNS:.040 ALUMINUM PAINT BLACK FACE:.080 ALUMINUM PAINT BLACK ILLUMINATION:WHITE LED'S AND PROPER TRANSFORMERS PUSH THROUGH CANS:ALUMINUM AND ANGLE IRON FABRICATION-PAINTED TO MATCH BLOCK WALL ROUTED ALUMINUM FACES WITH CLEAR ACRYLIC PUSH THROUGH COPY-COVERED IN DUO TONE BLACK TO WHITE VINYL. CANS HAVE REMOVABLE AND INTERCHANGEABLE FACES. ILLUMINATION:WHITE LED'S AND PROPER TRANSFORMERS _. OW NUM pAGUNn �� I �LEU iAN4WPMEn TENANT NAME TENANT NAME o P ELEC,HN,L C—.AAM � ,LLPLMSiIMG 3 T1 TENANT NAME TENANT NAME -� �A,Hz C/N WI REMtnAeLE FA ;,, 1EWf+��NHff.,—1.1 W1,i,wtMAu,MAW11C5 , :. l UL APPROVED INSTALLATION DETAIL REVERSE PAN"NACU'LEI I EH5 WIIH LEU ILLUMINATION&HUSH IHROUGH LEU ILLUMINATED CI IANNEL CAN WITI I REMOVABLE FACES MOUNTED ON A CMU BLOCK WALL FACE INSTALL IN ACCORDANCE WITH THE NEC AND LOCAL ELECTRICAL CODES 281-0" Overall Radius Wall Length ► I N L LO .� O � _ 4* = TENANT NAME TENANT NAME R TENANT NAME TENANT NAME SCALE:3/8"=1'-0 WEST E3N E RN S1 f&A W N I N D TEMECULA REGIONAL CENTER POWER CENTER 11 MASTER SIGN PROGRAM ADDENDUM SEPTEMBER 29,2010 PROPOSED 11Y-TIME CONDITIO TENANT NAME TENANT NAME TENANT NAME TENANT NAME 1 . 1 I NIGHT-TIME CONDITIONS TENANT NAME TENANT NAME TENANT NAME TENANT NAME W E STEN S 1 GN. AAWNI N G TEMECULA REGIONAL CENTER POWER CENTER 11 MASTER SIGN PROGRAM ADDENDUM SEPTEMBER 29,2010 Site Plan l Y ip 1 \ WIZ r a n \ J( 3 6 Signage Wall to replace afisting Tenant Monument Sign(102) I i r y ,\ \ • r \ ` ((tt ;_ Qypy V11yyDy" Legend Wall Sign W E S T E R N S I G N Signage Wall A w G TEMECULA REGIONAL CENTER POWER CENTER II MASTER SIGN PROGRAM ADDENDUM SEPTEMBER 29,2010 • • 0