Loading...
HomeMy WebLinkAboutWienerschnitzel #126STOP a TEMECULA PARKWAY SCALE: NTS 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 SIGN SCOPE OF WORK / DESCRIPTION PROJECT TITLE 0 (D 0 0 MANUFACTURE AND INSTALL A TOTAL OF (4) INTERNALLY ILLUMINATED LOGOS MANUFACTURE AND INSTALL A TOTAL OF (4) INTERNALLY ILLUMINATED CHANNELIZED LETTERS MANUFACTURE & INSTALL (I) DOUBLE FACED, NON - ILLUMINATED DIRECTIONAL SIGN MANUFACTURE & INSTALL (I) DOUBLE FACED, NON - ILLUMINATED DIRECTIONAL SIGN MANUFACTURE AND INSTALL A TOTAL OF (2) INTERNALLY ILLUMINATED CANOPIES INSTALL (I) MENU BOARD INSTALL (I) SPEAKER POST INSTALL (I) PRE SELL MENU BOARD PPROvED SUBJECT, TO BUILDING DEPT. APPROVAL CITY OF TEMECUL A PLANNING DEPT. PROJECT MEETS ZONING STANDARDS PERMITS ARE REQUIRED SIGNATURE. nATF.%1F0 •/3 WIENERSCHNITZEL 0815 32080 TEMECULA PKWY TEMECULA, CA Jos NUMBER 47934 Soles COREY NORTHCOTT Drarnnbp NICOLE Dat. 3 -21 -13 Soar AS NOTED Felder S/ SKETCFES /W /WIENERSCHNITZEL /TEMECULA 815 Al. 47934R4.cDR Design/ 001 REVISIONS Dat. By ORIGINAL NG Dat. By 3 -22 -13 CM 8 -14 -13 NG APPROVAL This proof drawing is for customer review and approval before fabrication begins. Encore Image will not be responsible for problems or discrepancies that could have been reasonably prevented by the proper review of this document. • The customer shall provide accessibility to remote transformers and /ar ballasts for installation, final 'inspection and service. • Dedicated 120 Volt sign circuits with a ground wire to be provided within 6' of the display(:) by the customer. • Sketch may vary from specified colors, Photos are for visual reference only, size and placement of signs may vary. Sien.tur• Dat. rrint•d Homo tltl. KO All sled ical signs shall comply with National Electrical Code (Article 600) and manufactured according to Underwriters Laboratories U.L. 40 standard and appropriately labeled. cOPYRIGHT 2013 This drawing, and all images therein, are the sole property of Encore Image and may nal be reproduced, displayed or transmitted, in full or in port, to anyone without the written permission from an officer of Encore Image Inc. (Encon! G 64 1(799. (54 372 ,,lam Slrcel 90 0. 9297 Oan.- Cpli(ornia 91762 600. 791_1187 F;» 909 - ?g8 -6376 9f[TE LICPNSF '997727 ,�w.v c. _. cimagc,com 42' -6" FRONT EQ r EQ EQ= 'TRITER 31?EE 115 "11111 falttlt ••• •it r•.11 NORTH ELEVATION 61' -8" SIDE EQ , EQ WEST ELEVATION EAST ELEVATION 0 000 RENDERINGS OF ELEVATIONS WITH PROPOSED SIGNS CL SOUTH ELEVATION 0 TES $Z 0 • SCALE SUBJECT TO BUILDING DEPT. APPROVAL CITY OF TEMECULA PLANNING DEPT. PROJECT MEETS ZONING STANDARDS PERMITS ARE REQUIRED SIGNATURE C DATE 9._:_g` NTS PROJECT TITLE WIENERSCHNITZEL #815 32080 TEMECULA PKWY TEMECULA, CA JOB NUMBER 47934 Sales COREY NORTHCOTT Drawn by NICOLE Date 3 -21-13 Scale AS NOTED Folder S/ SKETCHES /W /WIENERSCHNITZEL /TEMECULA 815 File 47934R3.CDR Design# 002 REVISIONS Date By ORIGINAL NG Date By 3 -22 -13 CM 8 -14 -13 CM APPROVAL _ _ This proof drawing is for customer review and approval before fabrication begins. Encore Image will not be responsible for problems or discrepancies that could have been reasonably prevented by the proper review of this document. The customer shall provide accessibility to remote transformers and /or ballasts for installation, final inspection and service. • Dedicated 120 Volt sign circuits with a ground wire to be provided within 6' of the display(s) by the customer. • Sketch may vary from specified colors. Photos are for visual reference only, size and placement of signs may vary. Signature Date P r i n t e d N a m e T i I l e IONMILIIMI All electrical signs shall comply with National Electrical Code (Article 600) and manufactured according to Underwriters Laboratories U.L. 48 standard and appropriately labeled. CAI cOPYRIGHT 2013 this drawing, and all images therein, are the sole property of Encore Image and may not be reproduced, displayed or transmitted, in full or in part, to anyone without the written permission from an officer of Encore Image Inc. 4 IC5C Encore I M A GE 303 West Main Slreel RO.Bax 9297 Ontario, California 91762 800-791-1187 Fax 909-988-6376 STATE LICENSE #947727 w,.vw.e nc are1 m oge. tom o Na- •ls 74" (A. FRONT VIEW MANUFACTURE & INSTALL (4) INTERNALLY ILLUMINATED LOGOS. FRONT VIEW 21.5 SQ. FT. SCALE: 3/4" = I' -0" .040" ALUM. LETTER RETURN. .063" WHITE ALUM. BACK (4) 3/8 "X 4" BOLTS AND TOGGLES 118" PAN FORMED FACE TRANSFORMER LED MODULES CAP OF FORMED FACE EXTERNAL ON /OFF SWITCH SPECIFICATIONS 2" 5" 1 1„ WEEP HOLES - 111111111111!11 HJ J SCALE: NTS APPROVED SUBJECT TO BUILDING DEPT APPROVAL CITY OF TEMECULA PLANNING DEPT. PROJECT MEETS ZONING STANDARDS PERMITS ARE REQUIRED SIGNATUiti _ P P• -- _ C ATE. ' 13 L E G E N D ALUMINUM -I POLY 5" DEEP PRE -COAT RED ALUMINUM RETURNS POLYCARBONATE FORMED FACE W/ CAP PAINT -2 PAINT -3 PAINTED SECOND SURFACE 230 -33 PAINTED SECOND SURFACE WHITE LED INTERNALLY ILLUMINATED USING WHITE LED SCALE: NTS PROJECT TITLE WIENERSCHNITZEL #815 32080 TEMECULA PKWY TEMECULA, CA JOB NUMBER 47934 Sales COREY NORTHCOTT Drawn by NICOLE Date 3 -21 -13 Scale AS NOTED Folder S/ SKETCHES /W /WIENERSCHNITZEL /TEMECULA 815 File 47934R3.CDR Design# 003 REVISIONS Date By ORIGINAL NG Date By APPROVAL This proof drawing is for customer review and approval before fabrication begins. Encore Image will not be responsible for problems or discrepancies that could have been reasonably prevented by the proper review of this document. The customer shall provide accessibility to remote transformers and /or ballasts for installation, final inspection and service. • Dedicated 120 Volt sign circuits with a ground wire to be provided within 6' of the display(s) by the customer. • Sketch may vary from specified colors. Photos are for visual reference only, size and placement of signs may vary. Signature Date P r i n t e d N a m e T i t l e [O, All electrical signs shall comply with National Electrical Code (Article 600) and manufactured according to Underwriters Laboratories U.L. 48 standard and appropriately labeled. cOPYRIGHT 2013 This drawing, and all images therein, are the sole property of Encore Image and may not be reproduced, displayed or transmitted, in full or in part, to anyone without the written permission from an officer of Encore Image Inc. (4!- ncore M A G E 4 ICSC 303 West Main SIreet P.O.Bax 9297 Ontario, California 91762 800- 791.1/87 Fax 909 - 968.6376 STATE LICENSE #947727 www.encOroimage.cam 91" 'TASTE Ft 1711 FRONT VIEW MANUFACTURE AND INSTALL (4) INTERNALLY ILLUMINATED CHANNELIZED LETTERS ALUMINUM IACRYLIC ALUMINUM ACRYLIC TRIM CAP FILM LED COLOR SCHEDULE r FILM LED L E GE .N:.. P. 5" DEEP WHITE ALUMINUM RETURNS WHITE ACRYLIC FACES RED TRIM CAPPED FACES 230 -36 BLUE FILM OVERLAY INTERNALLY ILLUMINATED USING WHITE LED SCALE: NTS ATTACHMENT DETAIL V A SCALE: II /2" = 1' APPirolED SUBJECT To BUILDING DEPT. APPROVAL CITY Y OF TEMECULA PLANNING DEPT. PROJECT MEETS ZONING STANDARDS PERMITS ARE REQUIRED SIGNATLRE.7 DATE `1Z' SCALE: NTS 13 PROJECT TITLE WIENERSCHNITZEL #815 32080 TEMECULA PKWY TEMECULA, CA Job NUMBER 47934 Sales COREY NORTHCOTT Drawn by NICOLE Date 3 -21 -13 Scale AS NOTED Folder S/ SKETCHES /W /WIENERSCHNITZEL /TEMECULA B15 File 47934R3.CDR Design# 004 REVISIONS Date By ORIGINAL NG Date By APPROVAL This proof drawing is for customer review and approval before fabrication begins. Encore Image will not be responsible for problems or discrepancies that could have been reasonably prevented by the proper review of this document. • The customer shall provide accessibility to remote transformers and /or ballasts for installation, final inspection and service. • Dedicated 120 Volt sign circuits with a ground wire to be provided within 6' of the display(s) by the customer. • Sketch may vary from specified colors. Photos are for visual reference only, size and placement of signs may vary. Signature Date Printed Name Title All electrical signs shall comply with National Electrical Code (Article 600) and manufactured according to Underwriters Laboratories U.L. 48 standard and appropriately labeled. [C* cOPYRIGHT 2013 This drawing, and all images therein, are the sole properly of Encore Image and may not be reproduced, displayed or transmitted, in full or in part, to anyone without the written permission from an officer of Encore Image Inc. 4 IcsC Encore I M A GE 303 West Main Street P.O. Box 9297 Ontario, California 91762 800- 791 -1187 Fox 909-988-6376 STATE LICENSE #947727 www.encoreimoge.com O 5" DEEP ALUMINUM RETURN QTRIM CAP Q ACRYLIC FACES QLED ILLUMINATION Q 14 AWG WIRE }0 I/ 4"0 DRAIN HOLES 0 #10 SCREWS WITH ANCHORS Mwm Q LED POWER PACK fO ALUMINUM LETTER BACKS PRIMARY ELECTRICAL SOURCE rip DISCONNECT SWITCH SCALE: NTS 13 PROJECT TITLE WIENERSCHNITZEL #815 32080 TEMECULA PKWY TEMECULA, CA Job NUMBER 47934 Sales COREY NORTHCOTT Drawn by NICOLE Date 3 -21 -13 Scale AS NOTED Folder S/ SKETCHES /W /WIENERSCHNITZEL /TEMECULA B15 File 47934R3.CDR Design# 004 REVISIONS Date By ORIGINAL NG Date By APPROVAL This proof drawing is for customer review and approval before fabrication begins. Encore Image will not be responsible for problems or discrepancies that could have been reasonably prevented by the proper review of this document. • The customer shall provide accessibility to remote transformers and /or ballasts for installation, final inspection and service. • Dedicated 120 Volt sign circuits with a ground wire to be provided within 6' of the display(s) by the customer. • Sketch may vary from specified colors. Photos are for visual reference only, size and placement of signs may vary. Signature Date Printed Name Title All electrical signs shall comply with National Electrical Code (Article 600) and manufactured according to Underwriters Laboratories U.L. 48 standard and appropriately labeled. [C* cOPYRIGHT 2013 This drawing, and all images therein, are the sole properly of Encore Image and may not be reproduced, displayed or transmitted, in full or in part, to anyone without the written permission from an officer of Encore Image Inc. 4 IcsC Encore I M A GE 303 West Main Street P.O. Box 9297 Ontario, California 91762 800- 791 -1187 Fox 909-988-6376 STATE LICENSE #947727 www.encoreimoge.com 4 CO c. N 180" 1 r WHITE SHOW THRU COPY 7230 -33 RED FILM THE WORLD'S LARGES HOT DOG CHAIN it-) SIZE MANUFACTURE a INSTALL (3) INTERNALLY ILLUMINATED CANOPIES 27" 1 1 1 SIDE VIEW J —J Q SCALE: NTS YELLOW LED STRIP ALUMINUM COVER - ALUMINUM FRAMING -- WHITE ACRYLIC FACE WITH RED FILM OVERLAY, CUT OUT COPY - FOR WHITE SHOW THRU COPY PTM #230 -15 YELLOW 800 MA FL LAMPS YELLOW LED STRIP ki,, I I I I l l I i I I I I I I I I I i. ATTACHMENT DETAIL - SECTION VIEW WHITE EGG -CRATE LENSES SCALE: 3/4 " =I' -0" 11/2" X I1/2" X 36" ALUMINUM ANGLE (QTY 2) 3/8" THRU BOLTS (QTY.4) 1/4" ALUMINUM PLATE EXISTING 2" X 4" BEAM LED POWER SUPPLY 3/8 "X5" LAG SCREWS INTO STUDS (MIN OF 6) APPROVED SUBJECT TO BUILDING DEPT. APPROVAL CITY OF TEMECULA PLANNING DEPT. PROJECT MEETS ZONING STANDARDS PERMITS ARE REQUIRED 4 DATE ? -/2 )3 SIGNATIJ9F SCALE: NTS PROJECT TITLE WIENERSCHNITZEL #815 32080 TEMECULA PKWY TEMECULA, CA Jos NUMBER 47934 Sales COREY NORTHCOTT Drawn by NICOLE Date 3 -21 -13 Scale AS NOTED Folder S/ SKETCHES /W /WIENERSCHNITZEL /TEMECULA 815 File 47934R3.CDR Design# 007 REVISIONS Date By 3 -22 -13 CM Date By 8 -14 -13 NG APPROVAL This proof drawing is for customer review and approval before fabrication begins. Encore Image will not be responsible for problems or discrepancies that could have been reasonably prevented by the proper review of this document. The customer shall provide accessibility to remote transformers and /or ballasts for installation, final inspection and service. • Dedicated 120 Volt sign circuits with a ground wire to be provided within 6' of the display(s) by the customer. Sketch may vary from specified colors. Photos are for visual reference only, size and placement of signs may vary. S i g n a t u r e D a t e Printed Name Title All electrical signs shall comply with National Electrical Code (Article 600) and manufactured according to Underwriters Laboratories U.L. 48 standard and appropriately labeled. 1E4cOPYRIGHT 2013 This drawing, and all images therein, are the sole property of Encore Image and may not be reproduced, displayed or transmitted, in full or in part, to anyone without the written permission From an officer of Encore Image Inc. ICSC CSA r. 303 West Main Street P.O.Box 9297 Ontario, California 91762 800- 791 -1187 Fax 909 -988 -6376 STATE LICENSE #947727 www.encoreimoge.com NOTES 1) Housing Constructed of Aluminum Extrusion Welded 2) Door Frames Will Be Extruded Aluminum 3) Door Flex WII Be 1/8" Hardcoat Polycarbonate 4) Entire Board Powder Coat Red 5) Graphics Load Into Qaphic Holder Supported BV Matte Acrylic Panels in Front and White Acrylic in Back NOTES MATBALS All Joints To Be Welded All Around Grade A36 Steel Slepes Grade A500 B Steel Tube Grade A325 Fastener Bolls DriveThru Amps: 3.4 Amps ®120%oItsAC Ballast (2) FulhanWH7 -120 -L Electronic Ballast Lamps: (8) F48T8/TL841 /HOIf10 Adder Amps: .98 Amps C 120/oltsAC Ballast (1) FulhanWH5.120 -L Electronic Ballast Lamps: (2) F48T8 /TL841 /HOOD 39" 18" .093 THK ALUMINUM EXTRUDED HOUSING WELDED CONSTRUCTION 711A" 601 /4" HIGH OUTPUT ELECTRONIC BALLASTS (2) 5/8 -11 x2" HEX HEAD BOLTS (8) GMENU BOARD - INSTALL (I) EXISTING MENU BOARD *24" 5/8"x 5 "x 36" STEEL PLATE 4 "x 1/4 "WALL STEEL TUBE �- 5/8 "x 7 "x 10" STEEL PLATE AvPROVED SUBJECT TO BUILDING DEPT APPPO !Al, CITY OF TEMECU . PL NN!,,C PROjECT S!1; s.7 -- `� SIGNATURE 7 DATE 9 I4j�3 48"T8 HIGH OUTPUT FLUORESCENT LAMPS (8) HIGH OUTPUT %'ELECTRONIC BALLAST (1) ALUMINUM MTG.STEEL SHROUD 1 ELECTRIC SF/VICE by others *60" *24" — ANCHOR BOLTS (4) 5/8" x 30" w /6" to SCALE: 3/4" = 1' -0" *NOTE These are approximate foundatio n measurements. The soil bearing capacity at the erection site must be considered when designing the foundation. The sign manufacturer is not able to predetermine the specific needs of each location. Consult a local engineer for design specifications. *60" !log 539/16" 171A" *24" -J PROJECT TITLE WIENERSCHNITZEL #815 32080 TEMECULA PKWY TEMECULA,CA Jos NUMBER 47934 Sales COREY NORTHCOTT Drawn by NICOLE Dale 3 -21-13 Scale AS NOTED Folder S/ SKETCHES /W /WIENERSCHNITZEL /TEMECULA 815 File 47934R3.CDR Design# 009 REVISIONS Date By Date By 3 -22 -13 CM APPROVAL This proof drawing is for customer review and approval before fabrication begins. Encore Image will not be responsible for problems or discrepancies that could have been reasonably prevented by the proper review of this document. ■ The customer shall provide accessibility to remote transformers and /or ballasts for installation, final inspection and service. • Dedicated 120 Volt sign circuits with a ground wire to be provided within 6' of the display(s) by the customer. • Sketch may vary from specified colors. Photos are for visual reference only, size and placement of signs may vary. S i g n a t u r e D a t e P r i n t e d N a m e T i t l e [O All electrical signs shall comply with National Electrical Code (Article 600) and manufactured according to Underwriters Laboratories U.L. 48 standard and appropriately labeled. [SI cOPYRIGHT 2013 This drawing, and all images therein, are the sole property of Encore Image and may not be reproduced, displayed or transmitted, in full or in part, to anyone without the written permission From an officer of Encore Image Inc. 4 ICSc Encofir I M A E 303 Wes! Main Street P.O.Box 9297 Ontario, California 91762 800- 791 -1187 Fax 909-988-6376 STATE LICENVSE #947727 www.oncoreimogo.com Cwrww.4 . STEEL BACK COVER REMOVABLE FOR SERVICE STEEL DIVIDERS FOR SPEAKER /M IC PLACEMENT 10 GA. STEEL FABRICATED BOTTOM MOUNTING PLATE 47" FABRICATED 18 GA. STEEL HOUSING 30 "* SPEAKER POST INSTALL (I) EXISTING SPEAKER POST = _ EXISTING ELECTRIC SERVICE 16,,* ANCHOR BOLTS 141 /4" 83/16" ---1 a t 9 1 II II II II II II II II 121 181i" ALUMINUM GRAPHIC HOLDER FIDNTVIEW APPROVED SUBJECT TO BUILDING DEPT APPROVAL CITY OF TEMECULA PLANKING DEPT. PROJECT MEETS ZONING STANDARDS PERMITS S €ARE REQUIRED DATE 9 /4 %3 SIGNATURE 5/a" Hole 77 /8" 0 41 /4" 77 /8" 11/z" Hole SCALE: II /2" = I' -O" PROJECT TITLE WIENERSCHNITZEL #815 32080 TEMECULA PKWY TEMECULA, CA JOB NUMBER 47934 Sales COREY NORTHCOTT Drawn by NICOLE Date 3 -21 -13 Scale AS NOTED Folder S/ SKETCHES /W /WIENERSCHNITZEL /TEMECIILA 815 File 47934R3, CDR Design# 010 REVISIONS Date By 3 -22 -13 CM Date By APPROVAL This proof drawing is for customer review and approval before fabrication begins. Encore Image will not be responsible for problems or discrepancies that could have been reasonably prevented by the proper review of this document. • The customer shall provide accessibility to remote transformers and /or ballasts for installation, final inspection and service. • Dedicated 120 Volt sign circuits with a ground wire to be provided within 6' of the display(s) by the customer. • Sketch may vary from specified colors. Photos are for visual reference only, size and placement of signs may vary. Signature Date Printed Name T i i l e All electrical signs shall comply with National Electrical Code (Article 600) and manufactured according to Underwriters Laboratories U.L. 48 standard and appropriately labeled. cOPYRIGHT 2013 This drawing, and all images therein, are the sole property of Encore Image and may not be reproduced, displayed or transmitted, in full or in part, to anyone without the written permission from an officer of Encore Image Inc. 4 IcSc Egw9re I AM1 A G E 303 West Main Street P.O.Box 9297 Ontario, California 91762 800- 791.1187 Fax 909- 988 -6376 STATE LICENSE #947727 www.encareimage.com .093 THK ALUMINUM EXTRUDED HOUSING WELDED CONSTRUCTION HIGH OUTPUT ELECTRONIC BALLAST ALUMINUM MTG. STEEL SHROUD - 1 71 /2 191/4 191/4 539/16 167/8 APPROVED SUBJECT TO BUILDING DEPT APPROVAL CITY OF TEMECULA PLANNING DEPT. PROJECT MEETS ZONING STANDARDS PERMITS ARE REQUIRED SIGNATURE -/' DA C3'12_629/32 10 GA. STEEL INNER BRACKETS 48 T8 HIGH OUTPUT FLUORESCENT LAMPS (2) ALUMINUM MTG. STEEL SHROUD T 318 x 5 x 8 STEEL PLATE 3/8 -16 x 1 1/2 HEX HEAD BOLTS 36 * 24 * PRE SELL MENU BOARD INSTALL (I) EXISTING PRE SELL MENU BOARD EXISTING ANCHOR BOLTS EXISTING ELECTRIC SERVICE 3 x 3 x 3/16 STEEL TUBE 1/2 x 10 x 7 STEEL PLATE 5" 16 * NOTES: 1) Housing Constructed of Aluminum Extrusion Welded 2) Door Frames Will Be Extruded Aluminum 3) Door Plex Will Be 1/8 Hardcoat Polycarbonate 4) Entire Board Powder Coat Red 5) Graphics Load Into Graphic Holder Supported By Matte Acrylic Panels in Front and White Acrylic in Back NOTES: MATERIALS: All Joints To Be Welded All Around Grade A36 Steel Shapes Grade A500 B Steel Tube 10 7 *NOTE: These are approximate foundation measurements. The soil bearing capacity at the erection site must be considered when designing the foundation. The sign manufacturer is not able to predetermine the specific needs of each location. Consult a local engineer for design specifications. SCALE: NTS PROJECT TITLE WIENERSCHNITZEL #815 32080 TEMECULA PKWY TEMECULA, CA Jos NUMBER 47934 Sales COREY NORTHCOTT Drawn by NICOLE Date 3 -21 -I3 Scale AS NOTED Folder S/ SKETCHES /W /WIENERSCHNITZEL /TEMECULA 815 File 47934R3.CDR Design# 011 REVISIONS Date By 3 -22 -13 CM Date By APPROVAL This proof drawing is for customer review and approval before fabrication begins. Encore Image will not be responsible for problems or discrepancies that could have been reasonably prevented by the proper review of this document. The customer shall provide accessibility to remote transformers and /or ballasts for installation, final inspection and service. • Dedicated 120 Volt sign circuits with a ground wire to be provided within 6' of the display(s) by the customer. • Sketch may vary from specified colors. Photos are for visual reference only, size and placement of signs may vary. S i g n a t u r e D a t e P r i n t e d N a m e T i t l e All electrical signs shall comply with National Electrical Code (Article 600) and manufactured according to Underwriters Laboratories U.L. 48 standard and appropriately labeled. [o4 cOPYRIGHT 2 01 3 This drawing, and all images therein, are the sole property of Encore Image and may not be reproduced, displayed or transmitted, in full or in part, to anyone without the written permission from an officer of Encore Image Inc. cEnc ore 4 Ices M A 6 E M A G E 303 West Moir] Street P..O.Box 9297 Onlorio, California 91762 800- 791.1187 Fax 909- 988 -6376 STATE LICENSE #947727 www.enco reimuge.tom 11. 1111.1 1 11111111-1 27" 12" Drive Thru 1111111111I111I 111111111111111 0 SIZE MANUFACTURE & INSTALL (1) DOUBLE FACED, NON- ILLUMINATED DIRECTORY SIGN W/ CUT OUT FOR SHOW THRU RED ' — FILM -2 0© SPECIFICATIONS SIGN AREA SQ FT: 3 Drive Thru —I FILM -2 1 FILM -I ALUM INUM -I PAINT -2 SCALE: I " =I' -0" W/ CUT OUT 1 FOR SHOW J THRU RED 27" 12" 1111111111111II 1111111111111 SIZE SIGN AREA SQ FT: 3 MANUFACTURE & INSTALL (I) DOUBLE FACED, NON- ILLUMINATED DIRECTORY SIGN APPROVED SUSJECT ?'i -i rtLIIL.PING DEPT APPROVAL CITY OF T EMECU A PLANNING r'EPT. PROJECT MEET i.: ZONING STANDARDS PERMITS ARE REQUIRED SIGNATURE-r- DATE 2. /Z 13 LEGEND t, ALUMINUM -I ALUMINUM POLE COVER ALUMINUM -2 21/2" DEEP ALUMINUM CABINET FILhM 230 -25 SUNFLOWER YELLOW FILM FILM -2 280 -10 WHITE REFLECTIVE FILM PAINT -I PTM 230 -33 RED SATIN FINISH PAINT -2 PTM BEIGE BUILDING COLOR W/ sUEDE FINISH SCALE: NTS FOOTING N 18" (DIA) GRADE 2" STANDARD ALUMINUM SO. TUBE CONCRETE FOOTING SCALE: I " =1' -0" SCALE: NTS WIENERSCHNITZEL *815 32080 TEMECULA PKWY TEMECULA, CA 47934 Sales COREY NORTHCOTT Drawn by NICOLE Date 3 -21 -13 Scale AS NOTED Folder S /SKETCHES /W /WIENERSCHNITZEL /TEMECIAA 815 �w 47934R4.CDR Design* 012 Date By 9 -5 -13 NG Date By 9 -6 -13 NG This proof drawing is for customer review and approval before fabrication begins. Encore Image will not be responsible for problems or discrepancies that could have been reasonably prevented by the proper review of this document. The customer shall provide accessibility to remote transformers and /or ballasts for installation, final inspection and service. Dedicated 120 Volt sign circuits with a ground wire to be provided within 6' of the displar(s) by the customer. Sketch may vary from specified colors. Photos are for visual reference only, size and placement of signs may vary. Signature Date Printed Name Title Rd All electrical signs shall comply with National Electrical Code (Article 600) and manufactured according to Underwriters Laboratories U.L. 48 standard and appropriately labeled. cOPYRIGHT 2013 This drawing, and all images therein, are the sole properly of Encore Image and may not be reproduced, displayed or transmitted, in full or in part, to anyone without the written permission from an officer of Encore Image Inc. I CSC Encore I Ji A G E 303 West Main Street P.O.Box 9297 Ontario, California 91762 800 -791 -1187 Fox 909 - 988 -6376 STATE LICENSE #947727 virivi.encoreimage.com