HomeMy WebLinkAboutTract Map 21675-5 Soils ReportPACIFIC SOILS ENGINEERING, INC.
7370 OPPORTUNI TV ROAD, SUITE "N", SAN DIEGO, CA LI FOR NIA 92111
TELEPHONE: (619) 560.1713, FAX: (619) 560-0380
Mesa Homes
27555 Ynez - Suite 200
Temecula, CA. 92591
Attention: Mr. Peter Trevino
CORPORATE HEADQUARTERS
(714) 220-0770
FAX: (714) 220-9589
LOS ANGELES COUNTY OFFICE
(213) 325-7272 or 775-6771
FAX: (213) 325-8854
SOUTH ORANGE COUNTY OFFICE
(714) 730-2122
FAX: (714) 730-5191
April 2, 1992
Work Order 400095H
Subject: Geotechnical Update Letter for
Lots 11 thru 14, inclusive, and
Lots 35 thru 40, inclusive, Tract
21675-5, City of Temecula, CA.
References: 1) Project Grading Report for Tract
21675-5, Lots 1 thru 63,incl.,Rancho
California, County of Riverside,CA.,
dated January 30, 1990 by Pacific Soils
Engineering, Inc. (W. O. 400095H)
2) Geotechnical Grading Plan Review,
Tract 21675-1 thru-6 (Margarita Village),
dated October 1, 1987 by Pacific Soils
Engineering, Inc. (W. O. 400085)
Gentlemen:
Presented herein is Pacific Soils Engineering, Inc. geotechnical
update letter for lots 11 through 14, inclusive and lots 35
through 40, inclusive, Tract 21675-5, in the City of Temecula,
California.
In preparing this letter a representative of this firm conducted
a site walkover of the subject lots and reviewed the reference
reports. Based upon this information, the following recommenda-
tions are presented.
Work Order 400095H
April 2, 1992
Page 2
1. Prior to the placement of concrete, the footing for the
proposed structures should be inspected by the project
geotechnical engineer. Footings should be founded upon
competent bedrock and/or compacted fill and should be free
of any loose and/or deleterious materials.
2. Depending upon the slab subgrade soil conditions, it may be
necessary to presaturate the slab subgrade for the low
expansive lots 13, 14 and 35 through 40, inclusive. Final
determination of presaturation requirements for these lots
should be based upon the actual field conditions as per the
project geotechnical engineer.
Provided that the above recommendations are utilized, lots 11
through 14, inclusive and lots 35 through 40, inclusive Tract
21675-5 are suitable for the intended use, from a geotechnical
viewpoint.
Unless specifically superceded herein, the recommendations as
presented in the project grading report (reference 1) remain
applicable.
PACIFIC SOILS ENGINEERING, INC.
Work Order 400095H
April 2, 1992
Page 3
Should you require any additional information or have any
questions concerning this letter, please contact the
undersigned.
Respectfully s mi
PACIFIC S(Qff*
,{V)pCdkESStp� / B
F .Y EY, .C.E REX P. KETTER, R.C.E.15251/G.E.461
, C' it Engin er Chief Executive Officer
E� egistr ion Ex • 6-30-95
By: 1— yr
JH HAN ON, C.E.G.990
Vic President
Dist: (4) Addressee
JAC/RPK/JAH:kr/H005
PACIFIC SOILS ENGINEERING, INC.