HomeMy WebLinkAboutParcel Map 30404 Soils ReportT.H.E. Soils Co., In& • Phone: (951) 894-2121 FAX: (951) 894-2122 E-mail: thesoilsco@a0ol.com 41539 Kalmia St., Suite 101 • Murrieta, CA 92562 June 2, 2010 Mr. Erik Halter Santiago Estates, LLC 5824 East Sandstone Court Orange, California 92869 SUBJECT: REPORT OF SITE IMPROVEMENTS Density Testing During Street Improvements along Santiago & Ormsby Roads Parcel Map 30404 30270 Santiago Road City of Temecula, Riverside County, California Work Order No. 14441001.23 REFERENCES: T.H.E. Soils Company, Inc., 2007, "Report of Rough Grading, Proposed 2 - Single -Family Residential Parcels, 30207 Santiago Road, APN: 945-080-009, Temecula, Riverside County, California", Work Order No. 1 1 9770 1.22, dated August 31, 2007. Dear Mr. Halter: W.C. Hobbs, Consulting Engineer, 2002, "Preliminary Soil Engineering Evaluation, Tentative Parcel Map 30404, Portion of Lot 6 of PM 6807, 30207 Santiago Road, City of Temecula, Riverside County, California", Project No. 02019-1, dated April 24, 2002. INTRODUCTION In accordance with your request, we have prepared this Final Report of Site Improvements presenting the results of our observation and testing during site improvements for the subject site including ribbon gutter, dry utilities backfill, water line backfill, curb & gutter subgrade, drive approach, handicap ramp, street subgrade and base grade testing. All compaction test results are included in this report in Appendix B, Tables I thru VII. The subject site was graded in accordance with the preliminary soils report, the requirements of the City of Temecula, and the current Uniform Building Code (UBC) at the time of street improvements. For our investigation and observation and testing of the above mentioned site improvements, we utilized a copy of the 40 -scale "Santiago and Ormsby Road Improvement Plan" prepared by the City of Temecula to locate our field density tests. Reduced not -to -scale copies of the street improvement plans were utilized as base maps for our Density Test Location Maps, Plates 1 and 2. T.H.E. Soils Company. Inc. W. O. No. 14441001.23 Mr. Erik Halter • • Santiago Estates, LLC June 2, 2010 Page 2 Proposed Development Proposed development included street improvements along Ormsby and Santiago Roads adjacent to Tentative Parcel 30404. Site Description Prior to development, the area of the street improvements was located along the northwest corner of Santiago and Ormsby Roads in the city of Temecula, southwest Riverside County, California and consisted of improved dirt roads. The geographical relationships of the site and surrounding area are shown on our Site Location Map, Figure 1. BACKFILL AND STREET IMPROVEMENT OBSERVATIONS & TESTING Water Line & Dry Utility Trench Backfill The onsite water line and dry utility connections located along Santiago and Ormsby Roads were properly compacted to a minimum degree of compaction of 90% as determined by ASTM D 1557. The materials used for backfill consisted predominately of onsite dark brown silty Sands (Unified Soil Classification - SM). Following placement of the pipe, fill placement and compaction was achieved utilizing a rubber -tired backhoe with compacting wheel and a water truck (as needed). The fill was placed in 6 to 8 inch thick lifts and moisture conditioned, as needed, to bring the material to near optimum moisture content, and was then properly compacted. A minimum degree of compaction of 90% was required as determined by ASTM D 1557. Ribbon Gutter and Curb & Gutter Prior to the placement of Class II aggregate base within proposed ribbon gutter extension in Santiago Road, the exposed subgrade materials were scarified to a depth of 12 -inches, moisture conditioned to near optimum moisture, if necessary, and re -compacted to +95 percent of the maximum dry density, as determined by ASTM D 1557, Test Method C. The Class 11 aggregate base within proposed ribbon gutter extension in Santiago Road were compacted to +95 percent of the maximum dry density, as determined by ASTM D 1557, Test Method C. Prior to the placement of Portland Cement concrete within proposed curb and gutters along Santiago and Ormsby Roads, the exposed subgrade materials were scarified to a depth of 12 -inches, moisture conditioned to near optimum moisture, if necessary, and re -compacted to +90 percent of the maximum dry density, as determined by ASTM D 1557. Drive Approaches and Handicap Ramp Prior to the placement of Portland Cement concrete within proposed drive approaches along Santiago and Ormsby Roads and the access ramp at the intersection of Santiago and Ormsby Roads, the exposed subgrade materials were scarified to a minimum depth of 12 -inches, moisture conditioned to T.H.E. Soils Company, Inc. W. 0. No. 14441001.23 j w - 4507, 7, a 4. Mr. Erik Halter Santiago Estates, LLC June 2, 2010 Page 3 near optimum moisture, and re -compacted to +95 percent of the maximum dry density, as determined by ASTM D 1557, Test Method A. Street Subarade Testing Prior to the placement of Class II Base, the exposed subgrade materials along Santiago and Ormsby Roads were scarified to a minimum depth of 12 -inches, moisture conditioned to near optimum moisture, and re -compacted to +95 percent of the maximum dry density, as determined by ASTM D 1557, Test Method A. Street Base Grade Testing Prior to the placement of asphalt concrete, the exposed base materials along Santiago and Ormsby Roads were moisture conditioned and compacted to +95 percent of the maximum dry density, as determined by ASTM D 1557, Test Method C. TESTING PROCEDURES Field Density Testing Field density testing was performed in accordance with ASTM Test Method D 6938-06el (nuclear gauge). Areas failing to meet the minimum compaction requirements were reworked and retested until the specified degree of compaction were achieved. The elevations and the results of the field density tests are presented in Appendix B, Results of Compaction Tests Table I. The approximate locations of the tests are shown on the Compaction Test Location Map, Plates 1 and 2. Maximum Density Determinations Maximum Density/Optimum Moisture determinations were performed in the laboratory on representative samples of onsite soils and imported Class II Base materials used in the fill operations. The tests were performed in accordance with ASTM - D 1557, Test Methods A & C. The test results, which were utilized in determining the degree of compaction achieved during fill placement, are presented in Appendix A, Table I. 6YIlu lu I\;i'I Our description of our observations and testing services, were limited to those site improvements that were observed and tested by our field personnel between April 4, 2007 and October 26, 2007. The conclusions and recommendations contained herein have been based upon our observations and testing as noted. It is our opinion the work performed in the areas denoted has generally been accomplished in accordance with the job specifications and the requirements of the regulating agencies. No conclusions or warranties are made for the areas not tested or observed. This report is T.H.E. Soils Company, Inc. W. 0. No. 14441001.23 0 0 EXISM MATCH CURB 8 GUTTER CURE TO REMAIN IN PLACE EftTING DRNEWAY APRONS TO REMAIN 63°41'40" E A N T A G Ol4.fiLtItANDFEATHR rwmes luf — --_ MATCH EIOSTNO PAVE1Bif. .h-�`t+'"'eta '%V J• /�. / i % / - (1094) 0 T.H.E. Soils Company, Inc. DENSITY TEST LOCATION MAP 1 DENSITY TESTING DURING STREET IMPROVEMENTS ALONG SANTIAGO 8 ORMSBY ROADS. PARCEL MAP 30404 30270 SANTIAGO ROAD Y CITY OF TEMECULA, RIVERSIDE COUNTY. CALIFORNIA PALL YRA .YIF.ME �EIUQOMOL.ULfMf OAPPROSYAIE LOCAIIDNd RNpI OVTTER iFn. O- APPIIOtWATE LOCATION Of M TER LINE TESTS 10 ' A^R°IUERTE L°cAnaN d clnu a aIrtTER Tun OA PPROFWATE LOCATION OF DRNE APPROACH a HANDICAP RAMP TESTS 72 APPROXIMATE LOCATOR OF STREET SUROIIADE TESTS O- AMIOMMATE LOCATION Of STREET 4SE GRADE TESTS I�I R: II •• n •-Yam 1 M t NOW yr ly RM...R_•an1lMiw -- — —� .---M,.MN YJ�����1�:.1r1✓- JEW 1 S; TA1M-152=1411 t4:�ifJ s;�.l•:� �►�l!�,���O���A ume�a�,.�� .h-�`t+'"'eta '%V J• /�. / i % / - (1094) 0 T.H.E. Soils Company, Inc. DENSITY TEST LOCATION MAP 1 DENSITY TESTING DURING STREET IMPROVEMENTS ALONG SANTIAGO 8 ORMSBY ROADS. PARCEL MAP 30404 30270 SANTIAGO ROAD Y CITY OF TEMECULA, RIVERSIDE COUNTY. CALIFORNIA PALL YRA .YIF.ME �EIUQOMOL.ULfMf OAPPROSYAIE LOCAIIDNd RNpI OVTTER iFn. O- APPIIOtWATE LOCATION Of M TER LINE TESTS 10 ' A^R°IUERTE L°cAnaN d clnu a aIrtTER Tun OA PPROFWATE LOCATION OF DRNE APPROACH a HANDICAP RAMP TESTS 72 APPROXIMATE LOCATOR OF STREET SUROIIADE TESTS O- AMIOMMATE LOCATION Of STREET 4SE GRADE TESTS FXIBTIG •" - RESIDENCE - _ Gn G y O CI t p N T.H.E. Soils Company, Inc. �� EXISTING g DENSITY TEST LOCATION MAP TOP OF SLOPE I I I III a rc DENSITY TESTING DURING STREET IMPROVEMENTS I I EiaBnrlO XAC OVER ALONG SANTIAGO 8 ORMSBY ROADS, PARCEL MAP 30404 I I CRUSHED AGGREGATE 30670 SANTIAGO ROAD ORA9 APPROVED BY CRY. CITY OF TEMECULA, RIVERSIDE COUNTY, CALIFORNIA `ry ` F.�NNmFn.Iw,mn TF. w„e xM Far> 9 _ _ �— O APPMOYIAIE LOGTXMI OF MNMOII OUTI®11FAT5 • ,, 1'2 Y Ong 19 • • • • 14 00 s=i% 15 1 I00 O •APPROSM ATE LOCATNNI OF LATER LINE TESTS o.AhIIUUMAIE LODATIOM OF CURB L GUTTER TESTS ! . _ ! EXI9T1NG P SIGN CONCRETE AND LTDE STING -� EMOTING ACDIKE j --- y -- O . APPROMMATE LOCATION OF DRIVE APPROACH A HANDICAP RAMP TESTS 6 { CR ER CURB A GUTTER TO BE REMOVED m I _ Yv CURB O . ± N - . TO REMAIN IN PLACE T2 . APPROXIMATE LOCATION OF nREEr weeTux TESTS N _ CLDn LENGTH=483.77 1t EXISTING AC PAVEMENT 12+80 ORMBBY Fr�J 'TrT� O .APPROXIMATE LOCATION OF STREET BASE GRADE TESTS EX TO REMAIN IN PLACE- 10+00VIAELOEL p ACPAVENQfT D77 0 Mr. Erik Halter Santiago Estates, LLC June 2, 2010 Page 4 0 based on information obtained during site improvements. No warranty as to the current conditions can be made. This report should be considered subject to review by the controlling authorities. LIMITATIONS This report is issued with the understanding that it is the responsibility of the owner, or his representative, to ensure that the information and recommendations contained herein are brought to the attention of the project architect and engineer. The project architect or engineer should incorporate such information and recommendations into the plans, and take the necessary steps to see that the contractor and subcontractors carry out such recommendations in the field. This firm does not practice or consult in the field of safety engineering. We do not direct the contractor's operations, and we cannot be responsible for other than our own personnel on the site: therefore, the safety of others is the responsibility of the contractor. The contractor should notify the owner if he considers any of the recommended actions presented herein to be unsafe. This firm did not provide any surveying services at the subject site and does not represent that the building locations, contours, elevations, or slopes are accurately depicted on the plans. The findings of this report are valid as of the report date. However, changes in the conditions of a property can occur with the passage of time, whether due to natural processes or the works of man on this or adjacent properties. In addition. changes in applicable or appropriate standards may occur, whether they result from legislation or the broadening of knowledge. Accordingly, the findings of this report may be invalidated wholly or partially by changes outside our control. Therefore, this report is subject to review and revision as changed conditions are identified. We sincerely appreciate this opportunity to be of service on this project. Should you have am questions regarding this report, or require additional information, please contact our office. Respectfully submitted. .H.E. Soils Company, Inc. J n P. Frey t r ject Manager JPF/JTR.jek No. ROE 23164 John T. Reinhart, RCE 23464 Civil Engineer, Expires 12-31-11 ACCOMPANYING MAPS AND APPENDICES Site Location Map - Figure 1 Appendix A - Laboratory Test Results Density Test Location Map - Plates 1 and 2 Appendix B - Results of Compaction Tests T.H.F. Sods Company. Inc W O. No W331001 23 0 0 APPENDIX A Laboratory Test Results T.H E Soils Company, Inc. W. O. No 1444 100 1 23 0 0 TABLE Maximum Density/Optimum Moisture Description Lbs/Ft3 Moisture 1 Medium Brown Silty Sand (SM) 130.9 7.4 2 Grayish Brown Sandy Silt (ML) 129.5 8.5 3 Grayish Brown Clayey Silt (ML) 122.8 12.1 4 Olive Brown Sandy Silt (ML) 118.6 6.1 5 Gray Crushed Base 136.0 6.5 r.H.E Sails Company. Inc. N' 0 No 1444100123 0 APPENDIX B Results of Compaction Tests I'M E. Soils Cmnpanp, Inc. W 0 No. 14441001 23 0 TABLE RESULTS OF COMPACTION TESTS— RIBBON CUTTER EXTENTION Job No.: 14441001.23 Name: SANTIAGO ESTATES LLC. Date: JUNE 2010 Test No. Test Date Elevation Depth (Feet) Moisture Content (%) Unit Dry Densitv (PCF) Relative Compaction (%) Soil Type Test Location See Plate 1 1 4/04/07 1093 7.8 113.0 86N -NG 1 Santiago Rd 2 " 1092 14.4 116.8 89N -NG 1 " 3 6/25/07 1094 6.0 127.1 97N I Ormsby Rd 4 1094 7.0 125.4 96N I " 5 4/05/07 1096 8.3 128.7 98N 1 6 1096 7.2 126.3 97N 1 " 7 1097 6.8 125.9 96N I 8 4/06/07 BG 3.7 129.4 95N 2 9 BG 4.3 130.8 96N 2 " SEE PLAN FOR TEST LOCATIONS SC - Sand Cone ASTM D1556-64; DC -Drive Cylinder ASTM D2937-71; N-Nuelear ASTM 3017; NG -Natural Ground +85% = Passing Test :-TEST FAILED, SEE RETEST Job No.: 14441001.23 TABLE 11 RESULTS OF COMPACTION TESTS— DRY UTILITIES Name: SANTIAGO ESTATES LLC. Date: JUNE 2010 Test No. Test Date Elevation Depth (Feet) Moisture Content (%) Unit Dry Density (PCF) Relative Compaction (%) Soil Type Test Location See Plates 1 & 2 1 6/22/07 -1 10.1 112.1 90N 3 Santiago Rd 2 " -1 12.0 110.0 90N 3 " 3 6/25/07 1099 5.5 133.1 98N 5 Ormsby Rd 4 SG 6.0 132.6 98N 5 " SEE PLAN FOR TEST LOCATIONS SC - Sand Cone ASTM D1556-64; DC -Drive Cylinder ASTM D2937-71; N -Nuclear ASTM 3017; NG -Natural Ground + 85%= Passing Test "TEST FAILED, SEE RETEST T.H.E. Soils Company, Inc W. 0 No. 14441001 23 0 0 TABLE III RESULTS OF COMPACTION TESTS— WATER LINE Job No.: 14441001.23 Name: SANTIAGO ESTATES LLC. Date: JUNE 2010 Test No. Test Date Elevation Depth (Feet) Moisture Content (%) Unit Dry Density (PCF) Relative Compaction (%) Soil Type Test Location See Plate 1 1 7/03/07 SG 13.7 118.3 96N 3 Santiago Rd 2 " SG 11.6 119.8 98N 3 " 3 SG 8.4 119.2 91N I " 4 SG 7.8 118.2 90N I " SEE PLAN FOR TEST LOCATIONS SC - Sand Cone ASTM D1556-64; DC -Drive Cylinder ASTM D2937-71; N -Nuclear ASTM 3017; NG -Natural Ground +85%= Passing Test **TEST FAILED, SEE RETEST Job No.: 14441001.23 TABLE IV RESULTS OF COMPACTION TESTS — CURB & GUTTER Name: SANTIAGO ESTATES - LLC Date: JUNE2010 Test No. Test Date Elevation Depth (Feet) Moisture Content (%) Unit Dry Density (PCF) Relative Compaction (%) Soil Type Test Location See Plates 1 & 2 1 8/17/07 SG 9.1 117.9 90N I Ormsby Rd 2 SG 11.0 120.2 92N I " 3 SG 8.4 119.2 91N I " 4 SG 7.8 118.2 90N I " 5 SG 8.8 119.3 91N I Santiago Rd 6 SG 10.3 119.0 91N I 7 SG 8.0 121.3 93N I 8 SG 10.0 120.0 92N 1 9 SG 9.8 118.7 91N 1 " 10 SG 12.0 119.7 91N I " SEE PLAN FOR TEST LOCATIONS SC - Sand Cone ASTM D1556-64; DC -Drive Cylinder ASTM D2937-71; N -Nuclear ASTM 3017; NG -Natural Ground + 85% = Passing Test **TEST FAILED, SEE RETEST T H G. Soils Company, Inc W 0. No. 14441001.23 Job No.: 14441001.23 0 0 TABLE V RESULTS OF COMPACTION TESTS — DRIVE APPROACH/HANDICAP RAMP Name: SANTIAGO ESTATES - LLC Date: JUNE 2010 Test No. Test Date Elevation Depth (Feet) Moisture Content (%) Unit Dry Density (PCF) Relative Compaction (% Soil Type Test Location See Plates I & 2 1 10/11/07 SG 9.8 130.1 99N 1 Ormsby Rd 2 SG 7.3 123.9 95N 1 " 3 SG 7.0 127.2 97N 1 " 4 SG 8.7 123.8 95N 1 5 SG 7.6 125.6 96N 1 Santiago Rd 6 10/16/07 SG 7.7 123.8 95N 1 7 SG 7.5 127.4 97N 1 " 8 SG 7.5 125.5 96N I Handicap Ramp SEE PLAN FOR TEST LOCATIONS SC - Sand Cone ASTM D1556-64; DC -Drive Cylinder ASTM D2937-71; N -Nuclear ASTM 3017; NG -Natural Ground + 85% =Passing Test **TEST FAILED, SEE RETEST T H E Soils Company, Inc W. 0 No 14441001.23 0 0 TABLE VI RESULTS OF COMPACTION TESTS -STREET SUBGRADE Job No.: 14441001.23 Name: SANTIAGO ESTATES - LLC Date: JUNE2010 Test No. Test Date Elevation, Depth (Feet) Moisture Content (%) Unit Dry Density (PCF) Relative Compaction (%) Soil Type Test Location See Plates I & 2 1 10/22/07 SG 7.9 127.6 97N 1 Ormsby Rd 2 SG 7.6 127.5 97N I " 3 SG 8.5 125.9 96N I " 4 SG 7.7 124.8 95N 1 Santiago Rd 5 Sc 7.9 125.6 96N I " 6 Sc 9.1 124.0 95N I 7 SG 9.0 125.1 96N 1 8 SG 8.4 124.9 95N I " 9 SG 7.6 125.5 96N I " 10 SG 7.7 124.5 95N 1 " II SG 8.2 126.8 97N 1 " 12 SG 12.0 118.5 96N 3 " SEE PLAN FOR TEST LOCATIONS SC - Sand Cone ASTM D1556-64; DC -Drive Cylinder ASTM D2937-71; N -Nuclear ASTM 3017; NG -Natural Ground +85%= Passing Test **TEST FAILED, SEE RETEST Job No.: 14441001.23 TABLE VII RESULTS OF COMPACTION TESTS- STREET BASE GRADE Name: SANTIAGO ESTATES - LLC Date: JUNE 2010 Test No. Test Date Elevation Depth (Feet) Moisture Content ("/1) Unit Dry Density (PCF) Relative Compaction (%) Soil Type Test Location See Plates 1 & 2 1 10/26/07 BG 6.4 131.7 97N 5 Santiago Road 2 BG 6.8 130.6 96N 5 3 BG 6.2 131.5 97N 5 4 BG 6.6 135.0 99N 5 Ormsby Rd 5 BG 6.9 134.7 99N 5 6 BG 7.0 131.0 96N 5 SEE PLAN FOR TEST LOCATIONS SC - Sand Cone ASTM D1556-64; DC -Drive Cylinder ASTM D2937-71; N -Nuclear ASTM 3017; NG -Natural Ground+ 85%= Passing Test **TEST FAILED, SEE RETEST T I I E Soils Company, Inc W 0 No 14441001 23 0 0 VANDENBERG CIVIL CONSULTING 31582 RAILROAD CANYON ROAD CANYON LAKE, CALIFORNIA 92587 714 392-1219 June 1, 2010 ERIK HALTER c/o SANTIAGO ESTATE, L.L.C. 5824 E. SANDSTONE CT. ORANGE, CA 92869 949 542-8700 o 542-8702f Subject: Certification of Rough Lines and Grades Portion Lot 6, Parcel Mp Ns 6607 30270 Santiago Road Certification of Street Improvement Construction 30270 Santiago Road and adjacent portion of Ormsby Road City of Temecula, California APN 945-080-009 Attention: Building Official Mr. Halter, Pursuant to your request, this letter has been prepared to document that the site has been graded in substantial conformance to the approved rough grading plan prepared by Vandenberg Civil Consulting and the street was built in substantial conformance with the approved street improvement plans prepared by Vandenberg Civil Consulting, In the event of any additional grading to be performed in the future, the property owner should only do so with plans approved by the City of Temecula. The opportunity to be of service is appreciated. Should questions or comments arise pertaining to this document, please contact us, in writing, for clarification. Respectfully Submitted, - "~ ((rw OM"DEUMcxe3MMMRobert Federighi, RCE 30000 �w9=1Civil Engineer , 10 50